BL600 Datasheet - SL Power Electronics

BL600
B L 6 0 0 L I T H I U M - I O N FA S T
CHARGERS
B L 6 0 0 L I T H I U M - I O N FA S T
CHARGERS
BVL
Number
of Cells
Volts
DC
Fast Charge
Maximum
Ault Part No.
Thermistor
Required
•
100-250 VAC
BL600-*-02-170-00-03K
No
2
8.4
1.7
•
In Case IEC 320
BL600-*-03-314-00-03K
No
3
12.6
1.4
•
LED Indicators
BL600-*-04-100-00-03K
No
4
16.8
1.0
•
Charges Li-Ion Batteries
BL600-*-02-170-00-21K
Yes
2
8.4
1.7
•
Optimizes Battery Life
BL600-*-03-314-00-21K
Yes
3
12.6
1.4
•
Meets Safety Agency Requirements
BL600-*-04-100-00-21K
Yes
4
16.8
1.0
•
Complies with EMI-RFI Regulations
•
Impact Resistant Polycarbonate Enclosure
•
Private Label Marking Available
•
3 Year Warranty
•
Modified and Custom Designs Also
Available
**Current Amps
**Available Current Rating
2 Cell
0.10 to 1.70A
3 Cell
0.10 to 1.40A
4 Cell
0.10 to 1.00A
Ault
AultPart
PartNo.
No.Key
Key
BL600 *
Product
Family
Name
02
Denotes
Number
Safety Timer
of Cells
(with or without
thermistors)
170
A U LT I N C O R P O R AT E D
7105 Northland Terrace | Minneapolis, Minnesota 55428 | USATEL (1) 763-592-1900
FAX (1) 763-592-1911 | E-MAIL [email protected] | WEB www.aultinc.com
© Copyright 2002 Ault Inc.
00
Fast Charge
Denotes standard
Current/Amps or custom
requirements
03
K
Connector Manufacturing
Location
BL600
B L 6 0 0 L I T H I U M - I O N FA S T
CHARGERS
Input
Environmental
Voltage
100-250 VAC -10%, +6%
Operating Temperature
0º to 40º C with no derating
Line Frequency
47 - 63 Hz
Storage Temperature
-30º to +85º C
Current
0.80A - 0.35A (lower with higher voltage)
Relative Humidity
5% to 95% non-condensing
Protection
Internal primary current fuse
Inrush limiting
Short circuit protection
Altitude
0-10,000 feet
Cooling
Convectional - non vented case
Mechanical
Electrical
Case and Dimensions
LP6 - Desktop
4.22L x 2.60W x 1.53H (in)
107L x 66W x 38H (mm)
Complies with EMC Directives
Case Material
Black 94V0 polycarbonate
CE
CE Compliant
Weight
8 ounces, 224 grams (excluding cord)
MTBF
100,000 calculated hours
Cords and Connectors
MTBF
100,000 calculated hours
Protection
Output current limiting
Short circuit protection
6 ft., 2 conductor, 20 AWG, Ault #3
connector and 6 ft., 3 conductor, 20
AWG Ault #21 connector. Other connectors are also available.
Topology
Switching - DC battery charger
Dielectric Withstand
3000 VAC, 4243 VDC primary- secondary
EMI
Charger Timers Available for 2, 3, and 4 Cell (*from pg. 1)
Safety Approvals
Agency Listings
CULus1950; TUV EN60950, CE
Input Configuration
1 = 3 hr/no thermistor
5 = 3hr hr/ thermistor
2 = 6 hr/no thermistor
6 = 6hr hr/ thermistor
3 = 9 hr/no thermistor
7 = 9hr hr/ thermistor
Please specify the Charger Timer Code in your order
Connectors
IEC320
w/ground
C14
(F)
Configuration: In Case IEC320 with ground
LED Indicators
Charge
80%
No
Charge Completion Abnormal Battery
Led1 (Yellow) ON
ON
OFF
Blink
OFF
Led2 (Green)
ON
ON
Blink
OFF
OFF
Other Connectors are available by special order
A U LT I N C O R P O R AT E D
7105 Northland Terrace | Minneapolis, Minnesota 55428 | USATEL (1) 763-592-1900
FAX (1) 763-592-1911 | E-MAIL [email protected] | WEB www.aultinc.com
© Copyright 2002 Ault Inc.