E5_C TEMPERATURE CONTROLLER A Full Lineup of Next-generation Temperature Controllers »» Contribute to Machine Downsizing » »H i g h - c o n t ra s t d i s p l a y » » E asy set-up and operation with a Special Software 2 T he new standard in t emperature control… Omron has been an active innovator in temperature control since introducing its first temperature controller in 1967. Now temperature control has taken a giant leap forward with Omron’s next generation of controllers – the E5_C, which set new global standards in the crucial areas of precision, user friendliness and control performance. The E5_C series will save you time and effort in set-up and operation, while enabling faster and more accurate monitoring/control of your process. The high- Key features •High-contrast, white LCD display visible from large distances and from any angle •Easy to set up, and operate intuitively via CX-Thermo without power supply •50 ms sampling period for fast and precise regulation •Functions for diagnosis for secure operations (see note 1) • Useful timer and logic operation functions eliminating the need of a PLC visibility display of the new series is also extremely easy to read and virtually eliminates any possibility for human error. NEW GENERATION Note 1: Alarm for loop break or PV change rate, heater burnout or sensor burnout detection 3 … is higher in every respect Clearer LCD display Easy set-up and operation Unique performance The large, high-contrast, white LCD Coupled with the autotuning algorithms, Although intrinsic high sampling speed display contributes to the exceptional which greatly reduce set-up and and high precision are built into the E5_C clarity and therefore readability of the commissioning time, Omron’s CX-Thermo series, Omron’s 2-PID control is a key E5_C series. The display can be read support software has been specially factor behind the advantage it offers over unambiguously from greater distances developed for use with the E5_C series. standard controllers. Using a powerful and from much wider viewing angles than This enables faster parameter set-up, algorithm, it makes all the difference to normal. easier device adjustment and simpler control stability and thus the quality of maintenance. your products. 4 Easy-to-read and Simple Temperature Control High-contrast display Easy-to-read White Characters with Large Display Size * 1 Big white characters on a black background achieve superior visibility. Character Height*1 (White PV) E5GC : 10.5 mm E5CC : 15.2 mm E5EC : 18 mm E5AC : 25 mm You can quickly and reliably check the PV from wide viewing angles, with natural light or in the subdued lighting conditions. Life Size E5CC The display remains easy to read even from wide viewing angles. Save space ! The compact and space-saving design of the new E5_C controller generation requires less panel depth (60 mm)*,2 allowing quick snap-mounting and easy installation even under very cramped conditions. *2 Excluding E5GC/E5DC/E5CC-U Shift Key to Reduce the Setting Work Required to Enter Values For example, to set 100°C, it was previously necessary to increment one degree at a time with a key, but with the shift key ( <<PF ), you can instantly change the digit. This simplifies numeric entry at worksite. Thanks to the IP66 protection*3 of the front cover, the E5_C can withstand humid environments and also be cleaned with non-aggressive fluids. *3 Excluding E5DC/E5CC-U Just press the shift key to move the digit. E5_C series Easy to connect, set-up and operate USB Bus Power Eliminates the Need for a Power Supply Even if you don’t connect a power supply to the Controller, power is supplied from the computer. CX-Thermo Special Setup Software for Easy Setup Just use computer key USB-Serial Conversion Cable*4 E58-CIFQ2 operations to easily achieve *4 The E58-CIFQ2-E required setup work. complex setups. You can greatly reduce the Communications Conversion Cable is also required to supply power to the E5EC/ E5AC/E5DC from the front panel. Installation (CD sold separately.) Easy connections to a PLC with programless communications. step1 Wire RS-485 communications. step3 Set the communications settings in the PLC to agree with those in the Temperature Controllers. step2 Set the communications addresses and the communications types in the Temperature Controllers. Communications start. More Convenient Operations The parameters can be copied from the master Temperature Controller to slave Temperature Controllers. Advantages The amount of work to set up the system is greatly reduced. PLC programming and memory are not required for communications. Communications even with multiple Temperature Controllers are automatically executed by the Temperature Controllers. Interface converters are not required, which reduces costs. Number of connected Digital Temperature Controllers: 32 max. (Up to 16 for the FX Series) No Interface converter is required. Master Temperature Controller can share RUN/STOP commands and set points with slave Temperature Controllers. Slope and offsets can be set for the set point. 5 6 Further Downsize Compact Machines On-panel Temperature Controller E5GC Easy-to-read Display in the Compact Body (48 x 24 mm) with a Stylish Panel-mounting Design Easy-to-read: White Characters and Dual Displays with the Largest Character Height in the Industry.* 1 The 48 x 24 mm size compact body inherits the high-visibility, big white characters from the E5_C series. With the dual, side-by-side displays (PV and green SV), there is no need to switch the display. *1 According to OMRON investigation, March 2014. Life Size 10.5 mm Controllers with Screwless Clamp Terminal Blocks for Easy Wiring Group mounting Horizontally or Vertically further downsizes machines In addition to the models with screw terminal blocks, The E5GC allows group mounting not only horizontally, models with screwless clamp terminal blocks are also but also vertically. This helps reduce machine size available. Easy wiring by inserting wires simplifies the even further when more than one Temperature wiring work. Controller is used.*2 *2 The ambient operating temperature must not exceed given below. Horizontal group mounting: 55°C Vertical group mounting of two Temperature Controllers: 45°C℃ Vertical group mounting of three or more Temperature Controllers: 40°C *3 Use Temperature Controllers with Screwless Clamp Terminal Blocks for vertical group mounting. You can select from three type of wires. Braided wire Solid wire Ferrule Vertical group mounting is possible! *3 Require Less Space in Control Panels In-panel Temperature Controller E5DC A 22.5-mm Width Body and DIN-Track Mounting capability Allow Installation in Limited Space of Control Panels Good Visibility and Operability equivalent to On-panel Models. The unified design of the E5_C Series has been inherited along with the functions, performance, and operability. We’ve achieved the equal operability as the on-panel models. On-panel mounting is also possible.*4 *4 Mounting Adapter required; sold separately. Removable Terminal Block for Easy Mounting and Replacement. Life Size Reduce Confirmation Work with Front-panel Display and Front-panel Key Settings HMI Temperature sensor Removing from the Terminal Block The image is for illustration purpose only. * Hooks must be pressed to remove from the terminal block. E5DC with displays and settings: You can confirm the process temperature at the Temperature Controller. Any settings made from the host can be easily confirmed on the Temperature Controller. Easy confirmation if the process temperature is updated at the host. 7 8 Unique performance with simplicity… …and more control functionality Extended inputs & outputs 1 •Remote SP input* With key features like simplicity in operation, Omron’s patented PID control, 50ms sampling period and the ability to handle multi-functional input and output types, the E5_C sets a new standard in fast and precise temperature regulation. It has all the familiar functionality available from existing Omron temperature controllers to 1 •Transfer output* (voltage 1-5 V output) added 2 •Event input* cover virtually any general-purpose demand. And naturally, the versatile E5_C series is •Auxiliary output available with input/output combinations to perfectly match all of your requirements. *1 Excluding E5GC/E5DC/E5CC-U *2 Excluding E5CC-U New feature •Program-less communication 3 •Position-proportional control* *3 Only for E5EC/E5AC 9 CHINA AMERICA EUROPE JAPAN ASIA-PACIFIC Global availability, support and network Providing you with the support you need to operate globally Facts and figures Whether you want to take your existing products into new industrial sectors, or whether •Presence in every continent you want to expand your business into entirely new geographical markets, Omron can help. We aim to offer the same level of support globally, without forgetting local needs. We have production facilities on every continent. Our smart communications network and seamless global support means we can provide you with parts and technical support wherever you sell your machines. And all of our components comply with major international standards, to ensure problem-free integration. It’s all there for you. •Over 35,000 employees •Almost 200 locations •Knowledge-sharing through our global infrastructure •Local R&D facilities synchronised to local needs •Local factories to ensure quick response •Global pricing terms •Global support 10 E5GC Model list (Models 0,1 or 2 auxiliary outputs) Output Terminal type Option No.* 1 Screw terminals (with cover) 015 016 023 024 Out 1: Relay Screwless Clamp Terminal 015 016 023 024 Screw terminals (with cover) 015 016 023 024 Out 1: Voltage (pulse) Screwless Clamp Terminal 015 016 023 024 Screw terminals (with cover) 015 016 024 Out 1: Liner cuurent Screwless Clamp Terminal 015 016 024 *1 *2 Option No.: Order code Order code AC100-240V A C/DC24V E5GC-RX0A6M-000*2 E5GC-RX1A6M-000 E5GC-RX2A6M-000 E5GC-RX1A6M-015 E5GC-RX2A6M-015 E5GC-RX2A6M-016 E5GC-RX2A6M-023 E5GC-RX1A6M-024 E5GC-RX0ACM-000*2 E5GC-RX1ACM-000 E5GC-RX2ACM-000 E5GC-RX1ACM-015 E5GC-RX2ACM-015 E5GC-RX2ACM-016 E5GC-RX2ACM-023 E5GC-RX1ACM-024 E5GC-QX0A6M-000*2 E5GC-QX1A6M-000 E5GC-QX2A6M-000 E5GC-QX1A6M-015 E5GC-QX2A6M-015 E5GC-QX2A6M-016 E5GC-QX2A6M-023 E5GC-QX1A6M-024 E5GC-QX0ACM-000*2 E5GC-QX1ACM-000 E5GC-QX2ACM-000 E5GC-QX1ACM-015 E5GC-QX2ACM-015 E5GC-QX2ACM-016 E5GC-QX2ACM-023 E5GC-QX1ACM-024 E5GC-CX0A6M-000*2 E5GC-CX1A6M-000 E5GC-CX2A6M-000 E5GC-CX1A6M-015 E5GC-CX2A6M-015 E5GC-CX2A6M-016 E5GC-CX1A6M-024 E5GC-CX0ACM-000*2 E5GC-CX1ACM-000 E5GC-CX2ACM-000 E5GC-CX1ACM-015 E5GC-CX2ACM-015 E5GC-CX2ACM-016 E5GC-CX1ACM-024 015 016 023 024 Communication Event Input 1 Heater Burnout SSR defect detection Event Input 2 Auxiliary outputs are not possible for these models. E5GC-RX0D6M-000*2 E5GC-RX1D6M-000 E5GC-RX2D6M-000 E5GC-RX1D6M-015 E5GC-RX2D6M-015 E5GC-RX2D6M-016 E5GC-RX2D6M-023 E5GC-RX1D6M-024 E5GC-RX0DCM-000*2 E5GC-RX1DCM-000 E5GC-RX2DCM-000 E5GC-RX1DCM-015 E5GC-RX2DCM-015 E5GC-RX2DCM-016 E5GC-RX2DCM-023 E5GC-RX1DCM-024 E5GC-QX0D6M-000*2 E5GC-QX1D6M-000 E5GC-QX2D6M-000 E5GC-QX1D6M-015 E5GC-QX2D6M-015 E5GC-QX2D6M-016 E5GC-QX2D6M-023 E5GC-QX1D6M-024 E5GC-QX0DCM-000*2 E5GC-QX1DCM-000 E5GC-QX2DCM-000 E5GC-QX1DCM-015 E5GC-QX2DCM-015 E5GC-QX2DCM-016 E5GC-QX2DCM-023 E5GC-QX1DCM-024 E5GC-CX0D6M-000*2 E5GC-CX1D6M-000 E5GC-CX2D6M-000 E5GC-CX1D6M-015 E5GC-CX2D6M-015 E5GC-CX2D6M-016 E5GC-CX1D6M-024 E5GC-CX0DCM-000*2 E5GC-CX1DCM-000 E5GC-CX2DCM-000 E5GC-CX1DCM-015 E5GC-CX2DCM-015 E5GC-CX2DCM-016 E5GC-CX1DCM-024 11 E5CC model list (all models 3 auxiliary outputs) Output Option No.* Order code Order code AC100-240V A C/DC24V E5CC-RX3A5M-000 E5CC-RX3A5M-001 E5CC-RX3A5M-003 E5CC-RX3A5M-005 E5CC-RX3A5M-006 E5CC-RX3A5M-007 E5CC-QX3A5M-000 E5CC-QX3A5M-001 E5CC-QX3A5M-003 E5CC-QX3A5M-005 E5CC-QX3A5M-006 E5CC-QX3A5M-007 E5CC-QQ3A5M-000 E5CC-QQ3A5M-001 E5CC-QQ3A5M-003 E5CC-QQ3A5M-005 E5CC-QQ3A5M-006 E5CC-QQ3A5M-007 E5CC-CX3A5M-000 E5CC-CX3A5M-004 E5CC-CX3A5M-005 E5CC-CX3A5M-006 E5CC-CX3A5M-007 E5CC-CQ3A5M-000 E5CC-CQ3A5M-001 E5CC-CQ3A5M-003 E5CC-CQ3A5M-005 E5CC-CQ3A5M-006 E5CC-CQ3A5M-007 001 003 005 006 007 Out 1: Relay Out 2: non 001 003 005 006 007 Out 1: Voltage (pulse) Out 2: non 001 003 005 006 007 Out 1: Voltage (pulse) Out 2: Voltage (pulse) 004 005 006 007 Out 1: Linear current Out 2: non 001 003 005 006 007 Out 1: Linear current Out 2: Voltage (pulse) E5CC-RX3D5M-000 E5CC-RX3D5M-001 E5CC-RX3D5M-003 E5CC-RX3D5M-005 E5CC-RX3D5M-006 E5CC-RX3D5M-007 E5CC-QX3D5M-000 E5CC-QX3D5M-001 E5CC-QX3D5M-003 E5CC-QX3D5M-005 E5CC-QX3D5M-006 E5CC-QX3D5M-007 E5CC-QQ3D5M-000 E5CC-QQ3D5M-001 E5CC-QQ3D5M-003 E5CC-QQ3D5M-005 E5CC-QQ3D5M-006 E5CC-QQ3D5M-007 E5CC-CX3D5M-000 E5CC-CX3D5M-004 E5CC-CX3D5M-005 E5CC-CX3D5M-006 E5CC-CX3D5M-007 E5CC-CQ3D5M-000 E5CC-CQ3D5M-001 E5CC-CQ3D5M-003 E5CC-CQ3D5M-005 E5CC-CQ3D5M-006 E5CC-CQ3D5M-007 As well as these models, other models are available on request. Please contact the local sales office for special requests. * Option No.: 001 003 004 005 006 Event Input 2, Heater Burnout SSR defect detection Communication 3-phase heater alarm Event Input 2, Communication Event Input 4 Event Input 2, Transfer output 007 Event Input 2, Remote SP 12 E5EC/E5AC Model list (all models 4 auxiliary outputs) Output Option No.* Out 1: Relay Out 2: non 009 010 011 Out 1: Voltage (pulse) Out 2: non 009 010 011 Out 1: Relay Out 2: Relay 009 010 011 Out 1: Voltage (pulse) Out 2: Voltage (pulse) Order code Order code A C100-240V A C/DC24V E5_C-RX4A5M-000 E5_C-RX4A5M-009 E5_C-RX4A5M-010 E5_C-RX4A5M-011 E5_C-QX4A5M-000 E5_C-QX4A5M-009 E5_C-QX4A5M-010 E5_C-QX4A5M-011 E5_C-RR4A5M-000 E5_C-RR4A5M-009 E5_C-RR4A5M-010 E5_C-RR4A5M-011 E5_C-QQ4A5M-000 E5_C-QQ4A5M-009 E5_C-QQ4A5M-010 E5_C-QQ4A5M-011 E5_C-QR4A5M-000 E5_C-QR4A5M-009 E5_C-QR4A5M-010 E5_C-QR4A5M-011 E5_C-CX4A5M-000 E5_C-CX4A5M-004 E5_C-CX4A5M-005 E5_C-CX4A5M-013 E5_C-CX4A5M-014 E5_C-CC4A5M-000 E5_C-CC4A5M-004 E5_C-CC4A5M-005 E5_C-CC4A5M-013 E5_C-CC4A5M-014 E5_C-CQ4A5M-000 E5_C-CQ4A5M-009 E5_C-CQ4A5M-010 E5_C-CQ4A5M-011 E5_C-PR4A5M-000 E5_C-PR4A5M-004 E5_C-PR4A5M-014 009 010 011 009 010 011 Out 1: Voltage (pulse) Out 2: Relay 004 005 013 014 Out 1: Linear current Out 2: non 004 005 013 014 Out 1: Linear current Out 2: Linear current Out 1: Linear current Out 2: Voltage (pulse) 009 010 011 Out 1: Relay* Out 2: Relay* 004 014 E5_C-RX4D5M-000 E5_C-RX4D5M-009 E5_C-RX4D5M-010 E5_C-RX4D5M-011 E5_C-QX4D5M-000 E5_C-QX4D5M-009 E5_C-QX4D5M-010 E5_C-QX4D5M-011 E5_C-RR4D5M-000 E5_C-RR4D5M-009 E5_C-RR4D5M-010 E5_C-RR4D5M-011 E5_C-QQ4D5M-000 E5_C-QQ4D5M-009 E5_C-QQ4D5M-010 E5_C-QQ4D5M-011 E5_C-QR4D5M-000 E5_C-QR4D5M-009 E5_C-QR4D5M-010 E5_C-QR4D5M-011 E5_C-CX4D5M-000 E5_C-CX4D5M-004 E5_C-CX4D5M-005 E5_C-CX4D5M-013 E5_C-CX4D5M-014 E5_C-CC4D5M-000 E5_C-CC4D5M-004 E5_C-CC4D5M-005 E5_C-CC4D5M-013 E5_C-CC4D5M-014 E5_C-CQ4D5M-000 E5_C-CQ4D5M-009 E5_C-CQ4D5M-010 E5_C-CQ4D5M-011 E5_C-PR4D5M-000 E5_C-PR4D5M-004 E5_C-PR4D5M-014 * Position proportional control model * Option No.: 004 005 009 010 011 Event Input 2, Communication Event Input 4 Event Input 2, Communication 3-phase heater alarm Event Input 4, Heater Burnout SSR defect detection Event Input 6, Remote SP, Heater Burnout SSR defect detection, Transfer output 013 014 Event Input 6, Remote SP, Transfer output Event Input 4, Communication Remote SP, Transfer output 13 E5CC-U model list (models 0, 1 or 2 auxiliary outputs) Output Order code Order code AC100-240V A C/DC24V E5CC-RW0AUM-000*2 Out 1: Relay E5CC-RW1AUM-000 E5CC-RW2AUM-000 E5CC-QX0AUM-000*2 E5CC-QX1AUM-000 E5CC-QX2AUM-000 E5CC-CX0AUM-000*2 E5CC-CX1AUM-000 E5CC-CX2AUM-000 Out 1: Voltage (pulse) Out 1: cuurent E5CC-RW0DUM-000*2 E5CC-RW1DUM-000 E5CC-RW2DUM-000 E5CC-QX0DUM-000*2 E5CC-QX1DUM-000 E5CC-QX2DUM-000 E5CC-CX0DUM-000*2 E5CC-CX1DUM-000 E5CC-CX2DUM-000 E5DC model list (models 0 or 2 auxiliary outputs) Output Option No.* 1 Order code Order code AC100-240V A C/DC24V E5DC-RX2ASM-000 E5DC-RX2AUM-000 E5DC-RX2ASM-002 E5DC-RX2AUM-002 E5DC-RX0ASM-015*2 E5DC-RX0AUM-015*2 E5DC-RX2ASM-017 E5DC-RX2AUM-017 E5DC-QX2ASM-000 E5DC-QX2AUM-000 E5DC-QX2ASM-002 E5DC-QX2AUM-002 E5DC-QX0ASM-015*2 E5DC-QX0AUM-015*2 E5DC-QX2ASM-017 E5DC-QX2AUM-017 E5DC-CX2ASM-000 E5DC-CX2AUM-000 E5DC-CX0ASM-015*2 E5DC-CX0AUM-015*2 E5DC-CX2ASM-015 E5DC-CX2AUM-015 E5DC-CX2ASM-016 E5DC-CX2AUM-016 002 Out 1: Relay 015 017 002 Out 1: Voltage (pulse) 015 017 015 Out 1: Liner cuurent 015 016 *1 *2 Option No.: E5DC-RX2DSM-000 E5DC-RX2DUM-000 E5DC-RX2DSM-002 E5DC-RX2DUM-002 E5DC-RX0DSM-015*2 E5DC-RX0DUM-015*2 E5DC-RX2DSM-017 E5DC-RX2DUM-017 E5DC-QX2DSM-000 E5DC-QX2DUM-000 E5DC-QX2DSM-002 E5DC-QX2DUM-002 E5DC-QX0DSM-015*2 E5DC-QX0DUM-015*2 E5DC-QX2DSM-017 E5DC-QX2DUM-017 E5DC-CX2DSM-000 E5DC-CX2DUM-000 E5DC-CX0DSM-015*2 E5DC-CX0DUM-015*2 E5DC-CX2DSM-015 E5DC-CX2DUM-015 E5DC-CX2DSM-016 E5DC-CX2DUM-016 002 015 016 017 Communication, Heater Burnout SSR defect detection Communication Event Input 1 Event Input 1 , Heater Burnout SSR defect detection Auxiliary outputs are not possible for these models. E5_C General purpose temperature controllers High performance & simplicity The next generation E5_C temperature controller is setting a new global standard in terms of precision and user-friendly design. Best control performance, easy set-up and outstanding visibility of the white IP66 LCD display have been integrated into a space-saving housing with only 60 mm* of depth. * Excluding E5GC • Fast and precise regulation: 50ms sampling loop period time • Easy to set up, and operate intuitively via CX-Thermo without power supply • Best contrast display using white LCD technology which is visible from a far distance and from any angle • Useful alarm and diagnosis functions for secure operation Specifications E5GC Power supply voltage Operating voltage range Power consumption Sensor input E5CC E5EC A in model number: 100 to 240 VAC, 50/60 Hz D in model number: 24 VAC, 50/60 Hz; 24 VDC 85% to 110% of rated supply voltage 5.9VA max. at 100 to 240 VAC, and Models with option selection of 000: Models with option selection of 000: 3.2VA max. at 24 VAC or 6.6 VA max. at 100 to 240 VAC, and 5.2 VA max. at 100 to 240 VAC, and 1.8W max. at 24 VDC 4.1 VA max. at 24 VAC or 2.3 W max. 3.1 VA max. at 24 VAC or1.6 W max. at 24 VDC All other models: 6.5 VA max. at 24 VDC All other models: 8.3 VA max. at 100 to 240 VAC, and 5.5 VA max. at 100 to 240 VAC, and 4.1 VA max. at 24 VAC or 3.2 W max. at 24 VDC at 24 VAC or 2.3 W max. at 24 VDC – Temperature input Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II Platinum resistance thermometer : Pt100 or JPt100 Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C E5AC Models with option selection of 000: 7.0 VA max. at 100 to 240 VAC, and 4.2 VA max. at 24 VAC or 2.4 W max. at 24 VDC All other models: 9.0 VA max. at 100 to 240 VAC, and 5.6 VA max. at 24 VAC or 3.4 W max. at 24 VDC – Analog input Current input: 4 to 20 mA or 0 to 20 mA Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V Input impedance Control method Indication accuracy (at the ambient temperature of 23°C) Auto-Tuning Self-Tuning Control output Relay output Voltage output (for driving SSR) Current input: 150 Ω max., Voltage input: 1 MΩ min. (Use a 1: 1 connection when connecting the ES2-HB/THB.) ON/OFF control or 2-PID control (with auto-tuning) Thermocouple: Thermocouple: (±0.3% of indication value or ±1°C, whichever is greater) ±1 digit max.*1 (±0.3% of indication value or ±1°C, whichever is greater) ±1 digit max.*1 Platinum resistance thermometer: Platinum resistance thermometer: (±0.2% of indication value or ±0.8°C, whichever is greater) ±1 digit max. (±0.2% of indication value or ±0.8°C, whichever is greater) ±1 digit max. Analog input: ±0.2% FS ±1 digit max. Analog input: ±0.2% FS ±1 digit max. CT input: ±5% FS ±1 digit max. CT input: ±5% FS ±1 digit max. Potentiometer input: ±5% FS ±1 digit max. Yes, 40%/100% MV output limit selection. When using Heat/Cool: Independent Heat & cool PID can be set by Auto-tuning. Yes SPST-NO, 250 VAC, 2 A (resistive load), SPST-NO, 250 VAC, 3 A (resistive load), electrical life; 100,000 operations, electrical life; 100,000 operations, minimum applicable minimum applicable load: 5 V, 10 mA (reference value) load: 5 V, 10 mA (reference value) Output voltage: 12 VDC ±20% (PNP), max. load current: 21 mA, with short-circuit protection circuit SPST-NO, 250 VAC, 5 A (resistive load), electrical life; 100,000 operations, minimum applicable load: 5 V, 10 mA (reference value) Output voltage: 12 VDC ±20% (PNP), max. load current: 40 mA, with short-circuit protection circuit (The maximum load current is 21 mA for models with two control outputs.) Linear current output 4 to 20 mA DC/0 to 20 mA DC, load: 500 Ω max., resolution: approx. 10,000 Auxiliary output Number of outputs 1 or 2 (depends on model) Output specifications SPST-NO relay outputs, 250 VAC, : 2 A (resistive load), Electrical life: 100,000 operations, Minimum applicable load: 10 mA at 5 V (reference value) Event input 3 SPST-NO relay outputs, 250 VAC, Models with 1 or 2 outputs: 3 A (resistive load), or Models with 3 outputs: 2 A (resistive load), Electrical life: 100,000 operations, Minimum applicable load: 10 mA at 5 V (reference value) 4 SPST-NO. relay outputs, 250 VAC, Models with 4 outputs: 2 A (resistive load), Electrical life: 100,000 operations, Minimum applicable load: 10 mA at 5 V (reference value) 2 or 4 (depends on model) 2, 4 or 6 (depends on model) Number of inputs 1 or 2 (depends on model) External contact input Contact input: ON: 1 kΩ max., OFF: 100 kΩ min. specifications Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max. Setting method Indication method Multi SP Other functions Ambient operating temperature Current flow: Approx. 7 mA per contact Digital setting using front panel keys 11-segment digital display and individual indicators Up to eight set points (SP0 to SP7) can be Up to eight set points (SP0 to SP7) can be saved and selected using the event inputs, saved and selected using the event inputs, key operations, or serial communications. key operations, or serial communications.*2 Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burnout (HB) alarm (including SSR failure (HS) alarm), 40% AT, 100% AT, MV limiter, input digital filter, self tuning, robust tuning, PV input shift, run/stop, protection functions, extraction of square root, MV change rate limit, logic operations, temperature status display, simple programming, moving average of input value, display brightness setting, simple transfer output, and work bit message*3 Storage temperature –10 to 55°C (with no condensation or icing), for 3-year warranty: -10 to 50°C with standard mounting (with no condensation or icing) 25% to 85% –25 to 65°C (with no condensation or icing) Degree of protection Front panel: IP66, Rear case: IP20, Terminals: IP00 Ambient operating humidity Input sampling period 50 ms Size in mm (HxWxD) 24×48×90 48×48×64 (Models with Screw Terminal Blocks)/ 24×48×93(Models with Screwless Clamp Terminal Blocks) 48×96×64 96×96×64 Note: *1. The indication accuracy of K thermocouples in the -200 to 1,300°C range, T and N thermocouples at a temperature of -100°C max., and U and L thermocouples at any temperatures is ±2°C ±1 digit max. The indication accuracy of the B thermocouple at a temperature of 400°C max. is not specified. The indication accuracy of B thermocouples at a temperature of 400 to 800°C is ±3°C max. The indication accuracy of the R and S thermocouples at a temperature of 200°C max. is ±3°C ±1 digit max. The indication accuracy of W thermocouples is (±0.3% of PV or ±3°C, whichever is greater) ±1 digit max. The indication accuracy of PL II thermocouples is (±0.3% of PV or ±2°C, whichever is greater) ±1 digit max. *2. Only four set points are selectable for event inputs. *3. Simple transfer output, and work bit message are only for E5GC. 14 E5_C General purpose temperature controllers High performance & DIN-Track Mounting The next generation E5_C temperature controller is setting a new global standard in terms of precision and user-friendly design. Best control performance, easy set-up and outstanding visibility of the white LCD display have been integrated into a space-saving housing. • • • • Specifications Fast and precise regulation: 50ms sampling loop period time Easy to set up, and operate intuitively via CX-Thermo without power supply Removable terminal block for easy mounting and replacement.* Useful alarm and diagnosis functions for secure operation * Only for E5DC E5CC-U E5DC Power supply voltage A in model number: 100 to 240 VAC, 50/60 Hz D in model number: 24 VAC, 50/60 Hz; 24 VDC Operating voltage range 85% to 110% of rated supply voltage Power consumption Models with option selection of 000: 5.2 VA max. at 100 to 240 VAC, and 3.1 VA max. at 24 VAC or 1.6 W max. at 24 VDC All other models: 6.5 VA max. at 100 to 240 VAC, and 4.1 VA max. at 24 VAC or 2.3 W max. at 24 VDC Sensor input – Temperature input Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II Platinum resistance thermometer: Pt100 or JPt100 Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C 4.9 VA max. at 100 to 240 VAC, and 2.8 VA max. at 24 VDC or 1.5 W max. at 24 VDC – Analog input Current input: 4 to 20 mA or 0 to 20 mA Voltage input: 1 to 5 V, 0 to 5 V, 0 to 10 V,or 0 to 50 mV (The 0 to 50 mV range applies to the E5CC-U only for those manufactured in May 2014 or later.) Input impedance Current input: 150 Ω max., Voltage input: 1 MΩ min. (Use a 1: 1 connection when connecting the ES2-HB/THB.) Control method ON/OFF control or 2-PID control (with auto-tuning) Thermocouple: (±1% of indication value or ±2°C, whichever is greater) ±1 digit max.*1 Platinum resistance thermometer: (±0.2% of indication value or ±0.8°C, whichever is greater) ±1 digit max. Analog input: ±0.2% FS ±1 digit max. Indication accuracy (at the ambient temperature of 23°C) (When mounted individually for E5DC) Auto-Tuning Thermocouple: (±0.3% of indication value or ±1°C, whichever is greater) ±1 digit max.*1 Platinum resistance thermometer: (±0.2% of indication value or ±0.8°C, whichever is greater) ±1 digit max. Analog input: ±0.2% FS ±1 digit max. CT input: ±5% FS ±1 digit max. Yes, 40%/100% MV output limit selection. When using Heat/Cool: Independent Heat & cool PID can be set by Auto-tuning. Yes Self-Tuning Control output Relay output SPDT, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5 V, 10 mA (reference value) SPST-NO, 250 VAC, 3 A (resistive load), electrical life; 100,000 operations minimum applicable load: 5 V, 10 mA (reference value) Voltage output (for driving SSR) Output voltage 12 VDC ±20% (PNP), max. load current: 21 mA, with short-circuit protection circuit Linear current output Auxiliary output Number of outputs Event input 4 to 20 mA DC/0 to 20 mA DC, load: 500 Ω max., resolution: approx. 10,000 1 or 2 (depends on model) 2 (depends on model) Output specifications SPST-NO relay outputs, 250 VAC, Models with 1 or 2 outputs: 3 A (resistive load), or Models with 3 outputs: 2 A (resistive load), Electrical life: 100,000 operations, Minimum applicable load: 10 mA at 5 V (reference value) SPST-NO relay outputs, 250 VAC, 2 A (resistive load), Electrical life: 100,000 operations, Minimum applicable load: 10mA at 5V (reference value) Number of inputs External contact input specifications - 1 (depends on model) Contact input: ON: 1 kΩ max., OFF: 100 kΩ min. Setting method Indication method Multi SP Other functions Ambient operating temperature Ambient operating humidity Storage temperature Degree of protection Input sampling period Size in mm (HxWxD) - Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max. Current flow: Approx. 7 mA per contact Digital setting using front panel keys 11-segment digital display and individual indicators Up to eight set points (SP0 to SP7) can be saved and selected using Up to eight set points (SP0 to SP7) can be saved and selected using the event inputs, key operations, or serial communications. the event inputs, key operations, or serial communications.*2 Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burnout (HB) alarm (including SSR failure (HS) alarm), 40% AT, 100% AT, MV limiter, input digital filter, self tuning, robust tuning, PV input shift, run/stop, protection functions, extraction of square root, MV change rate limit, logic operations, temperature status display, simple programming, moving average of input value, and display brightness setting –10 to 55°C (with no condensation or icing), for 3-year warranty: -10 to 50°C with standard mounting (with no condensation or icing) 25% to 85% –25 to 65°C (with no condensation or icing) Front panel: IP50, Rear case: IP20, Terminals: IP00 Main unit: IP20, Terminal unit: IP00 50 ms 48×48×76.8 96×22.5×85 Note: *1. The indication accuracy of K thermocouples in the -200 to 1,300°C range, T and N thermocouples at a temperature of -100°C max., and U and L thermocouples at any temperatures is ±2°C ±1 digit max. The indication accuracy of the B thermocouple at a temperature of 400°C max. is not specified. The indication accuracy of B thermocouples at a temperature of 400 to 800°C is ±3°C max. The indication accuracy of the R and S thermocouples at a temperature of 200°C max. is ±3°C ±1 digit max. The indication accuracy of W thermocouples is (±0.3% of PV or ±3°C, whichever is greater) ±1 digit max. The indication accuracy of PL II thermocouples is (±0.3% of PV or ±2°C, whichever is greater) ±1 digit max. *2. Only two set points are selectable for event inputs. 15 E5_C General purpose temperature controllers USB communication cable E58-CIFQ2 E5GC E5CC E5EC E5AC E5CC-U E5DC E58-CIFQ2 E58-CIFQ2-E – – E58-CIFQ2 E58-CIFQ2-E Exchange this head for E5GC/E5EC/E5AC/E5DC E5GC/E5CC/E5EC/E5AC/E5CC-U/E5DC optional tools Option Order code USB based configuration cable E58-CIFQ2, E58-CIFQ2-E (for E5GC/E5EC/E5AC/E5DC) PC based configuration and tuning software EST2-2C-MV4 Refer to the E5 C/E5 C-T Digital Temperature Controllers Datasheet (Cat. No. H177) for details. OMRON Corporation Tokyo, JAPAN Industrial Automation Company Authorized Distributor: Contact: www.ia.omron.com Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69-2132 JD Hoofddorp The Netherlands Tel: (31)2356-81-300/Fax: (31)2356-81-388 OMRON ELECTRONICS LLC One Commerce Drive Schaumburg, IL 60173-5302 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 119967 Tel: (65) 6835-3011/Fax: (65) 6835-2711 OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120, China Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 © OMRON Corporation 2011-2014 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. CSM_8_1_0614 Cat. No. H176-E1-06 0614(1111)