e5_c temperature controller - OMRON Industrial Automation

E5_C TEMPERATURE CONTROLLER
A Full Lineup of Next-generation Temperature Controllers
»» Contribute to Machine Downsizing
» »­H i g h - c o n t ra s t d i s p l a y
» » ­E asy set-up and operation with a Special Software
2
­T he new standard in
­t emperature control…
­Omron has been an active innovator in temperature
control since introducing its first temperature
controller in 1967. Now temperature control has
taken a giant leap forward with Omron’s next
generation of controllers – the E5_C, which set new
global standards in the crucial areas of precision,
user friendliness and control performance. The E5_C
series will save you time and effort in set-up and
operation, while enabling faster and more accurate
monitoring/control of your process. The high-
Key features
•High-contrast, white LCD display visible
from large distances and from any
angle
•Easy to set up, and operate intuitively
via CX-Thermo without power supply
•50 ms sampling period for fast and
precise regulation
•Functions for diagnosis for secure
operations (see note 1)
• Useful timer and logic operation
functions eliminating the need of a PLC
visibility display of the new series is also extremely
easy to read and virtually eliminates any possibility
for human error.
NEW GENERATION
­Note 1: Alarm for loop break or PV change rate, heater
burnout or sensor burnout detection
3
­… is higher in every respect
­Clearer LCD display
­Easy set-up and operation
­Unique performance
­The large, high-contrast, white LCD
­Coupled with the autotuning algorithms,
­Although intrinsic high sampling speed
display contributes to the exceptional
which greatly reduce set-up and
and high precision are built into the E5_C
clarity and therefore readability of the
commissioning time, Omron’s CX-Thermo
series, Omron’s 2-PID control is a key
E5_C series. The display can be read
support software has been specially
factor behind the advantage it offers over
unambiguously from greater distances
developed for use with the E5_C series.
standard controllers. Using a powerful
and from much wider viewing angles than
This enables faster parameter set-up,
algorithm, it makes all the difference to
normal.
easier device adjustment and simpler
control stability and thus the quality of
maintenance.
your products.
4
Easy-to-read and Simple Temperature Control
High-contrast display
Easy-to-read White Characters with Large Display Size * 1
Big white characters on a black background achieve superior visibility.
Character Height*1
(White PV)
E5GC : 10.5 mm
E5CC : 15.2 mm
E5EC : 18 mm
E5AC : 25 mm
You can quickly and reliably check the PV from wide viewing angles,
with natural light or in the subdued lighting conditions.
Life Size
E5CC
The display remains easy to read even from wide viewing
angles.
­Save space !
The compact and space-saving design of the new E5_C
controller generation requires less panel depth (60 mm)*,2
allowing quick snap-mounting and easy installation even
under very cramped conditions.
*2 Excluding E5GC/E5DC/E5CC-U
Shift Key to Reduce the Setting Work
Required to Enter Values
For example, to set 100°C, it was previously necessary to
increment one degree at a time with a key, but with the
shift key ( <<PF ), you can instantly change the digit. This
simplifies numeric entry at worksite.
Thanks to the IP66
protection*3 of the front
cover, the E5_C can
withstand humid
environments and also
be cleaned with
non-aggressive fluids.
*3 Excluding E5DC/E5CC-U
Just press the shift key to
move the digit.
E5_C series
Easy to connect, set-up and operate
USB Bus Power Eliminates the Need for a Power Supply
Even if you don’t connect a power supply to the Controller,
power is supplied from the computer.
CX-Thermo
Special Setup Software
for Easy Setup
Just use computer key
USB-Serial
Conversion Cable*4
E58-CIFQ­2
operations to easily achieve
*4 The E58-CIFQ2-E
required setup work.
complex setups.
You can greatly reduce the
Communications Conversion
Cable is also required to
supply power to the E5EC/
E5AC/E5DC from the front
panel.
Installation
(CD sold separately.)
Easy connections to a PLC with programless communications.
step1
Wire RS-485 communications.
step3
Set the communications settings
in the PLC to agree with those
in the Temperature Controllers.
step2
Set the communications addresses
and the communications types
in the Temperature Controllers.
Communications start.
More Convenient
Operations
The parameters can be copied from
the master Temperature Controller
to slave Temperature Controllers.
Advantages
The amount of work to set up the system is greatly reduced.
PLC programming and memory are not required
for communications.
Communications even with multiple Temperature Controllers
are automatically executed by the Temperature Controllers.
Interface converters are not required, which reduces costs.
Number of connected Digital Temperature Controllers: 32 max.
(Up to 16 for the FX Series)
No Interface
converter is required.
Master Temperature Controller can share RUN/STOP
commands and set points with slave Temperature
Controllers. Slope and offsets can be set for the set point.
5
6
Further Downsize Compact Machines
On-panel Temperature Controller
E5GC
Easy-to-read Display in the Compact Body (48 x 24 mm)
with a Stylish Panel-mounting Design
Easy-to-read: White Characters and Dual Displays
with the Largest Character Height in the Industry.* 1
The 48 x 24 mm size compact body inherits the high-visibility, big white characters
from the E5_C series.
With the dual, side-by-side displays (PV and green SV), there is no need to switch
the display.
*1 According to OMRON investigation, March 2014.
Life Size
10.5 mm
Controllers with Screwless Clamp
Terminal Blocks for Easy Wiring
Group mounting Horizontally or
Vertically further downsizes machines
In addition to the models with screw terminal blocks,
The E5GC allows group mounting not only horizontally,
models with screwless clamp terminal blocks are also
but also vertically. This helps reduce machine size
available. Easy wiring by inserting wires simplifies the
even further when more than one Temperature
wiring work.
Controller is used.*2
*2 The ambient operating temperature must not exceed given below.
Horizontal group mounting: 55°C
Vertical group mounting of two Temperature Controllers: 45°C℃
Vertical group mounting of three or more Temperature Controllers: 40°C
*3 Use Temperature Controllers with Screwless Clamp Terminal Blocks for
vertical group mounting.
You can select from
three type of wires.
Braided wire
Solid wire
Ferrule
Vertical group mounting is
possible!
*3
Require Less Space in Control Panels
In-panel Temperature Controller
E5DC
A 22.5-mm Width Body and DIN-Track Mounting capability
Allow Installation in Limited Space of Control Panels
Good Visibility and Operability equivalent to On-panel Models.
The unified design of the E5_C Series has been inherited along with
the functions, performance, and operability. We’ve achieved the equal
operability as the on-panel models.
On-panel mounting is also possible.*4
*4 Mounting Adapter required; sold separately.
Removable Terminal Block for
Easy Mounting and Replacement.
Life Size
Reduce Confirmation Work with Front-panel
Display and Front-panel Key Settings
HMI
Temperature
sensor
Removing from the Terminal Block
The image is for illustration purpose only.
*
Hooks must be pressed to remove from the terminal block.
E5DC
with displays and settings:
You can confirm the
process temperature at
the Temperature
Controller.
Any settings made from the
host can be easily confirmed
on the Temperature
Controller.
Easy confirmation if the
process temperature is
updated at the host.
7
8
­Unique performance with simplicity…
…and more control functionality
Extended inputs & outputs
1
•Remote SP input*
With key features like simplicity in operation, Omron’s patented PID control, 50ms
sampling period and the ability to handle multi-functional input and output types,
the E5_C sets a new standard in fast and precise temperature regulation. It has all
the familiar functionality available from existing Omron temperature controllers to
1
•Transfer output*
(voltage 1-5 V output) added
2
•Event input*
cover virtually any general-purpose demand. And naturally, the versatile E5_C series is
•Auxiliary output
available with input/output combinations to perfectly match all of your requirements.
*1 Excluding E5GC/E5DC/E5CC-U
*2 Excluding E5CC-U
New feature
•Program-less communication
3
•Position-proportional control*
*3 Only for E5EC/E5AC
9
­CHINA
­AMERICA
­EUROPE
­JAPAN
­ASIA-PACIFIC
­Global availability, support and network
Providing you with the support you need to
operate globally
Facts and figures
Whether you want to take your existing products into new industrial sectors, or whether
•Presence in every continent
you want to expand your business into entirely new geographical markets, Omron can
help. We aim to offer the same level of support globally, without forgetting local needs.
We have production facilities on every continent.
Our smart communications network and seamless global support means we can
provide you with parts and technical support wherever you sell your machines. And all
of our components comply with major international standards, to ensure problem-free
integration. It’s all there for you.
•Over 35,000 employees
•Almost 200 locations
•Knowledge-sharing through our
global infrastructure
•Local R&D facilities synchronised to
local needs
•Local factories to ensure quick
response
•Global pricing terms
•Global support
10
E5GC Model list (Models 0,1 or 2 auxiliary outputs)
Output
Terminal type
­Option No.* 1
Screw terminals
(with cover)
015
016
023
024
Out 1: Relay
Screwless Clamp
Terminal
015
016
023
024
Screw terminals
(with cover)
015
016
023
024
Out 1: Voltage
(pulse)
Screwless Clamp
Terminal
015
016
023
024
Screw terminals
(with cover)
015
016
024
Out 1: Liner
cuurent
Screwless Clamp
Terminal
015
016
024
*1
*2
Option No.:
­Order code
­Order code
AC100-240V
A
­ C/DC24V
E5GC-RX0A6M-000*2
E5GC-RX1A6M-000
E5GC-RX2A6M-000
E5GC-RX1A6M-015
E5GC-RX2A6M-015
E5GC-RX2A6M-016
E5GC-RX2A6M-023
E5GC-RX1A6M-024
E5GC-RX0ACM-000*2
E5GC-RX1ACM-000
E5GC-RX2ACM-000
E5GC-RX1ACM-015
E5GC-RX2ACM-015
E5GC-RX2ACM-016
E5GC-RX2ACM-023
E5GC-RX1ACM-024
E5GC-QX0A6M-000*2
E5GC-QX1A6M-000
E5GC-QX2A6M-000
E5GC-QX1A6M-015
E5GC-QX2A6M-015
E5GC-QX2A6M-016
E5GC-QX2A6M-023
E5GC-QX1A6M-024
E5GC-QX0ACM-000*2
E5GC-QX1ACM-000
E5GC-QX2ACM-000
E5GC-QX1ACM-015
E5GC-QX2ACM-015
E5GC-QX2ACM-016
E5GC-QX2ACM-023
E5GC-QX1ACM-024
E5GC-CX0A6M-000*2
E5GC-CX1A6M-000
E5GC-CX2A6M-000
E5GC-CX1A6M-015
E5GC-CX2A6M-015
E5GC-CX2A6M-016
E5GC-CX1A6M-024
E5GC-CX0ACM-000*2
E5GC-CX1ACM-000
E5GC-CX2ACM-000
E5GC-CX1ACM-015
E5GC-CX2ACM-015
E5GC-CX2ACM-016
E5GC-CX1ACM-024
015
016
023
024
Communication
Event Input 1
Heater Burnout SSR
defect detection
Event Input 2
Auxiliary outputs are not possible for these models.
E5GC-RX0D6M-000*2
E5GC-RX1D6M-000
E5GC-RX2D6M-000
E5GC-RX1D6M-015
E5GC-RX2D6M-015
E5GC-RX2D6M-016
E5GC-RX2D6M-023
E5GC-RX1D6M-024
E5GC-RX0DCM-000*2
E5GC-RX1DCM-000
E5GC-RX2DCM-000
E5GC-RX1DCM-015
E5GC-RX2DCM-015
E5GC-RX2DCM-016
E5GC-RX2DCM-023
E5GC-RX1DCM-024
E5GC-QX0D6M-000*2
E5GC-QX1D6M-000
E5GC-QX2D6M-000
E5GC-QX1D6M-015
E5GC-QX2D6M-015
E5GC-QX2D6M-016
E5GC-QX2D6M-023
E5GC-QX1D6M-024
E5GC-QX0DCM-000*2
E5GC-QX1DCM-000
E5GC-QX2DCM-000
E5GC-QX1DCM-015
E5GC-QX2DCM-015
E5GC-QX2DCM-016
E5GC-QX2DCM-023
E5GC-QX1DCM-024
E5GC-CX0D6M-000*2
E5GC-CX1D6M-000
E5GC-CX2D6M-000
E5GC-CX1D6M-015
E5GC-CX2D6M-015
E5GC-CX2D6M-016
E5GC-CX1D6M-024
E5GC-CX0DCM-000*2
E5GC-CX1DCM-000
E5GC-CX2DCM-000
E5GC-CX1DCM-015
E5GC-CX2DCM-015
E5GC-CX2DCM-016
E5GC-CX1DCM-024
11
E5CC model list (all models 3 auxiliary outputs)
­Output
­Option No.*
­Order code
­Order code
AC100-240V
A
­ C/DC24V
E5CC-RX3A5M-000
E5CC-RX3A5M-001
E5CC-RX3A5M-003
E5CC-RX3A5M-005
E5CC-RX3A5M-006
E5CC-RX3A5M-007
E5CC-QX3A5M-000
E5CC-QX3A5M-001
E5CC-QX3A5M-003
E5CC-QX3A5M-005
E5CC-QX3A5M-006
E5CC-QX3A5M-007
E5CC-QQ3A5M-000
E5CC-QQ3A5M-001
E5CC-QQ3A5M-003
E5CC-QQ3A5M-005
E5CC-QQ3A5M-006
E5CC-QQ3A5M-007
E5CC-CX3A5M-000
E5CC-CX3A5M-004
E5CC-CX3A5M-005
E5CC-CX3A5M-006
E5CC-CX3A5M-007
E5CC-CQ3A5M-000
E5CC-CQ3A5M-001
E5CC-CQ3A5M-003
E5CC-CQ3A5M-005
E5CC-CQ3A5M-006
E5CC-CQ3A5M-007
001
003
005
006
007
Out 1: Relay
Out 2: non
001
003
005
006
007
Out 1: Voltage (pulse)
Out 2: non
001
003
005
006
007
Out 1: Voltage (pulse)
Out 2: Voltage
(pulse)
004
005
006
007
Out 1: Linear current
Out 2: non
001
003
005
006
007
Out 1: Linear
current
Out 2: Voltage
(pulse)
E5CC-RX3D5M-000
E5CC-RX3D5M-001
E5CC-RX3D5M-003
E5CC-RX3D5M-005
E5CC-RX3D5M-006
E5CC-RX3D5M-007
E5CC-QX3D5M-000
E5CC-QX3D5M-001
E5CC-QX3D5M-003
E5CC-QX3D5M-005
E5CC-QX3D5M-006
E5CC-QX3D5M-007
E5CC-QQ3D5M-000
E5CC-QQ3D5M-001
E5CC-QQ3D5M-003
E5CC-QQ3D5M-005
E5CC-QQ3D5M-006
E5CC-QQ3D5M-007
E5CC-CX3D5M-000
E5CC-CX3D5M-004
E5CC-CX3D5M-005
E5CC-CX3D5M-006
E5CC-CX3D5M-007
E5CC-CQ3D5M-000
E5CC-CQ3D5M-001
E5CC-CQ3D5M-003
E5CC-CQ3D5M-005
E5CC-CQ3D5M-006
E5CC-CQ3D5M-007
­As well as these models, other models are available on request. Please contact the local sales office for special requests.
*
Option No.:
001
003
004
005
006
Event Input 2,
Heater Burnout SSR
defect detection
Communication
3-phase heater
alarm
Event Input 2,
Communication
Event Input 4
Event Input 2,
Transfer output
007
Event Input 2,
Remote SP
12
E5EC/E5AC Model list (all models 4 auxiliary outputs)
­Output
­Option No.*
Out 1: Relay
Out 2: non
009
010
011
Out 1: Voltage (pulse)
Out 2: non
009
010
011
Out 1: Relay
Out 2: Relay
009
010
011
Out 1: Voltage (pulse)
Out 2: Voltage
(pulse)
­Order code
­Order code
A
­ C100-240V
A
­ C/DC24V
E5_C-RX4A5M-000
E5_C-RX4A5M-009
E5_C-RX4A5M-010
E5_C-RX4A5M-011
E5_C-QX4A5M-000
E5_C-QX4A5M-009
E5_C-QX4A5M-010
E5_C-QX4A5M-011
E5_C-RR4A5M-000
E5_C-RR4A5M-009
E5_C-RR4A5M-010
E5_C-RR4A5M-011
E5_C-QQ4A5M-000
E5_C-QQ4A5M-009
E5_C-QQ4A5M-010
E5_C-QQ4A5M-011
E5_C-QR4A5M-000
E5_C-QR4A5M-009
E5_C-QR4A5M-010
E5_C-QR4A5M-011
E5_C-CX4A5M-000
E5_C-CX4A5M-004
E5_C-CX4A5M-005
E5_C-CX4A5M-013
E5_C-CX4A5M-014
E5_C-CC4A5M-000
E5_C-CC4A5M-004
E5_C-CC4A5M-005
E5_C-CC4A5M-013
E5_C-CC4A5M-014
E5_C-CQ4A5M-000
E5_C-CQ4A5M-009
E5_C-CQ4A5M-010
E5_C-CQ4A5M-011
E5_C-PR4A5M-000
E5_C-PR4A5M-004
E5_C-PR4A5M-014
009
010
011
009
010
011
Out 1: Voltage (pulse)
Out 2: Relay
004
005
013
014
Out 1: Linear current
Out 2: non
004
005
013
014
Out 1: Linear current
Out 2: Linear current
Out 1: Linear
current
Out 2: Voltage
(pulse)
009
010
011
Out 1: Relay*
Out 2: Relay*
004
014
E5_C-RX4D5M-000
E5_C-RX4D5M-009
E5_C-RX4D5M-010
E5_C-RX4D5M-011
E5_C-QX4D5M-000
E5_C-QX4D5M-009
E5_C-QX4D5M-010
E5_C-QX4D5M-011
E5_C-RR4D5M-000
E5_C-RR4D5M-009
E5_C-RR4D5M-010
E5_C-RR4D5M-011
E5_C-QQ4D5M-000
E5_C-QQ4D5M-009
E5_C-QQ4D5M-010
E5_C-QQ4D5M-011
E5_C-QR4D5M-000
E5_C-QR4D5M-009
E5_C-QR4D5M-010
E5_C-QR4D5M-011
E5_C-CX4D5M-000
E5_C-CX4D5M-004
E5_C-CX4D5M-005
E5_C-CX4D5M-013
E5_C-CX4D5M-014
E5_C-CC4D5M-000
E5_C-CC4D5M-004
E5_C-CC4D5M-005
E5_C-CC4D5M-013
E5_C-CC4D5M-014
E5_C-CQ4D5M-000
E5_C-CQ4D5M-009
E5_C-CQ4D5M-010
E5_C-CQ4D5M-011
E5_C-PR4D5M-000
E5_C-PR4D5M-004
E5_C-PR4D5M-014
* Position proportional control model
*
Option No.:
004
005
009
010
011
Event Input 2,
Communication
Event Input 4
Event Input 2,
Communication
3-phase heater
alarm
Event Input 4,
Heater Burnout SSR
defect detection
Event Input 6,
Remote SP,
Heater Burnout SSR
defect detection,
Transfer output
013
014
Event Input 6,
Remote SP,
Transfer output
Event Input 4,
Communication
Remote SP,
Transfer output
13
E5CC-U model list (models 0, 1 or 2 auxiliary outputs)
­Output
­Order code
­Order code
AC100-240V
A
­ C/DC24V
E5CC-RW0AUM-000*2
Out 1: Relay
E5CC-RW1AUM-000
E5CC-RW2AUM-000
E5CC-QX0AUM-000*2
E5CC-QX1AUM-000
E5CC-QX2AUM-000
E5CC-CX0AUM-000*2
E5CC-CX1AUM-000
E5CC-CX2AUM-000
Out 1: Voltage (pulse)
Out 1: cuurent
E5CC-RW0DUM-000*2
E5CC-RW1DUM-000
E5CC-RW2DUM-000
E5CC-QX0DUM-000*2
E5CC-QX1DUM-000
E5CC-QX2DUM-000
E5CC-CX0DUM-000*2
E5CC-CX1DUM-000
E5CC-CX2DUM-000
E5DC model list (models 0 or 2 auxiliary outputs)
­Output
­Option No.* 1
­Order code
­Order code
AC100-240V
A
­ C/DC24V
E5DC-RX2ASM-000
E5DC-RX2AUM-000
E5DC-RX2ASM-002
E5DC-RX2AUM-002
E5DC-RX0ASM-015*2
E5DC-RX0AUM-015*2
E5DC-RX2ASM-017
E5DC-RX2AUM-017
E5DC-QX2ASM-000
E5DC-QX2AUM-000
E5DC-QX2ASM-002
E5DC-QX2AUM-002
E5DC-QX0ASM-015*2
E5DC-QX0AUM-015*2
E5DC-QX2ASM-017
E5DC-QX2AUM-017
E5DC-CX2ASM-000
E5DC-CX2AUM-000
E5DC-CX0ASM-015*2
E5DC-CX0AUM-015*2
E5DC-CX2ASM-015
E5DC-CX2AUM-015
E5DC-CX2ASM-016
E5DC-CX2AUM-016
002
Out 1: Relay
015
017
002
Out 1: Voltage (pulse)
015
017
015
Out 1: Liner cuurent
015
016
*1
*2
Option No.:
E5DC-RX2DSM-000
E5DC-RX2DUM-000
E5DC-RX2DSM-002
E5DC-RX2DUM-002
E5DC-RX0DSM-015*2
E5DC-RX0DUM-015*2
E5DC-RX2DSM-017
E5DC-RX2DUM-017
E5DC-QX2DSM-000
E5DC-QX2DUM-000
E5DC-QX2DSM-002
E5DC-QX2DUM-002
E5DC-QX0DSM-015*2
E5DC-QX0DUM-015*2
E5DC-QX2DSM-017
E5DC-QX2DUM-017
E5DC-CX2DSM-000
E5DC-CX2DUM-000
E5DC-CX0DSM-015*2
E5DC-CX0DUM-015*2
E5DC-CX2DSM-015
E5DC-CX2DUM-015
E5DC-CX2DSM-016
E5DC-CX2DUM-016
002
015
016
017
Communication,
Heater Burnout SSR
defect detection
Communication
Event Input 1
Event Input 1 ,
Heater Burnout SSR
defect detection
Auxiliary outputs are not possible for these models.
E5_C
General purpose temperature controllers
High performance & simplicity
The next generation E5_C temperature controller is setting a new global standard in
terms of precision and user-friendly design. Best control performance, easy set-up
and outstanding visibility of the white IP66 LCD display have been integrated into a
space-saving housing with only 60 mm* of depth.
* Excluding E5GC
• Fast and precise regulation: 50ms sampling loop period time
• Easy to set up, and operate intuitively via CX-Thermo without power supply
• Best contrast display using white LCD technology which is visible from a far
distance and from any angle
• Useful alarm and diagnosis functions for secure operation
Specifications
E5GC
Power supply voltage
Operating voltage range
Power consumption
Sensor input
E5CC
E5EC
A in model number: 100 to 240 VAC, 50/60 Hz D in model number: 24 VAC, 50/60 Hz; 24 VDC
85% to 110% of rated supply voltage
5.9VA max. at 100 to 240 VAC, and
Models with option selection of 000:
Models with option selection of 000:
3.2VA max. at 24 VAC or
6.6 VA max. at 100 to 240 VAC, and
5.2 VA max. at 100 to 240 VAC, and
1.8W max. at 24 VDC
4.1 VA max. at 24 VAC or 2.3 W max.
3.1 VA max. at 24 VAC or1.6 W max.
at 24 VDC All other models: 6.5 VA max. at 24 VDC All other models: 8.3 VA max.
at 100 to 240 VAC, and 5.5 VA max.
at 100 to 240 VAC, and 4.1 VA max.
at 24 VAC or 3.2 W max. at 24 VDC
at 24 VAC or 2.3 W max. at 24 VDC
– Temperature input
Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II
Platinum resistance thermometer : Pt100 or JPt100
Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C
E5AC
Models with option selection of 000:
7.0 VA max. at 100 to 240 VAC, and
4.2 VA max. at 24 VAC or 2.4 W max.
at 24 VDC All other models: 9.0 VA max.
at 100 to 240 VAC, and 5.6 VA max.
at 24 VAC or 3.4 W max. at 24 VDC
– Analog input
Current input: 4 to 20 mA or 0 to 20 mA Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V
Input impedance
Control method
Indication accuracy
(at the ambient temperature of 23°C)
Auto-Tuning
Self-Tuning
Control output Relay output
Voltage output
(for driving SSR)
Current input: 150 Ω max., Voltage input: 1 MΩ min. (Use a 1: 1 connection when connecting the ES2-HB/THB.)
ON/OFF control or 2-PID control (with auto-tuning)
Thermocouple:
Thermocouple:
(±0.3% of indication value or ±1°C, whichever is greater) ±1 digit max.*1
(±0.3% of indication value or ±1°C, whichever is greater) ±1 digit max.*1
Platinum resistance thermometer:
Platinum resistance thermometer:
(±0.2% of indication value or ±0.8°C, whichever is greater) ±1 digit max.
(±0.2% of indication value or ±0.8°C, whichever is greater) ±1 digit max.
Analog input: ±0.2% FS ±1 digit max.
Analog input: ±0.2% FS ±1 digit max.
CT input: ±5% FS ±1 digit max.
CT input: ±5% FS ±1 digit max.
Potentiometer input: ±5% FS ±1 digit max.
Yes, 40%/100% MV output limit selection. When using Heat/Cool: Independent Heat & cool PID can be set by Auto-tuning.
Yes
SPST-NO, 250 VAC, 2 A (resistive load), SPST-NO, 250 VAC, 3 A (resistive load),
electrical life; 100,000 operations,
electrical life; 100,000 operations,
minimum applicable
minimum applicable
load: 5 V, 10 mA (reference value)
load: 5 V, 10 mA (reference value)
Output voltage: 12 VDC ±20% (PNP), max.
load current: 21 mA, with short-circuit protection circuit
SPST-NO, 250 VAC, 5 A (resistive load),
electrical life; 100,000 operations,
minimum applicable load: 5 V, 10 mA (reference value)
Output voltage: 12 VDC ±20% (PNP), max.
load current: 40 mA, with short-circuit protection circuit
(The maximum load current is 21 mA for models with two control outputs.)
Linear current output 4 to 20 mA DC/0 to 20 mA DC, load: 500 Ω max., resolution: approx. 10,000
Auxiliary output Number of outputs 1 or 2 (depends on model)
Output specifications SPST-NO relay outputs, 250 VAC, :
2 A (resistive load),
Electrical life: 100,000 operations,
Minimum applicable load: 10 mA at
5 V (reference value)
Event input
3
SPST-NO relay outputs, 250 VAC,
Models with 1 or 2 outputs:
3 A (resistive load), or Models with
3 outputs: 2 A (resistive load),
Electrical life: 100,000 operations,
Minimum applicable load: 10 mA at
5 V (reference value)
4
SPST-NO. relay outputs, 250 VAC,
Models with 4 outputs: 2 A (resistive load),
Electrical life: 100,000 operations,
Minimum applicable load: 10 mA at 5 V (reference value)
2 or 4 (depends on model)
2, 4 or 6 (depends on model)
Number of inputs 1 or 2 (depends on model)
External contact input Contact input: ON: 1 kΩ max., OFF: 100 kΩ min.
specifications
Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
Setting method
Indication method
Multi SP
Other functions
Ambient operating temperature
Current flow: Approx. 7 mA per contact
Digital setting using front panel keys
11-segment digital display and individual indicators
Up to eight set points (SP0 to SP7) can be Up to eight set points (SP0 to SP7) can be saved and selected using the event inputs,
saved and selected using the event inputs, key operations, or serial communications.
key operations, or serial communications.*2
Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burnout (HB) alarm (including SSR failure (HS) alarm), 40% AT, 100% AT,
MV limiter, input digital filter, self tuning, robust tuning, PV input shift, run/stop, protection functions, extraction of square root, MV change rate limit, logic operations,
temperature status display, simple programming, moving average of input value, display brightness setting, simple transfer output, and work bit message*3
Storage temperature
–10 to 55°C (with no condensation or icing), for 3-year warranty: -10 to 50°C with standard mounting (with no condensation or icing)
25% to 85%
–25 to 65°C (with no condensation or icing)
Degree of protection
Front panel: IP66, Rear case: IP20, Terminals: IP00
Ambient operating humidity
Input sampling period
50 ms
Size in mm (HxWxD)
24×48×90
48×48×64
(Models with Screw Terminal Blocks)/
24×48×93(Models with Screwless
Clamp Terminal Blocks)
48×96×64
96×96×64
Note: *1. The indication accuracy of K thermocouples in the -200 to 1,300°C range, T and N thermocouples at a temperature of -100°C max., and U and L thermocouples at any temperatures is
±2°C ±1 digit max. The indication accuracy of the B thermocouple at a temperature of 400°C max. is not specified. The indication accuracy of B thermocouples at a temperature of
400 to 800°C is ±3°C max. The indication accuracy of the R and S thermocouples at a temperature of 200°C max. is ±3°C ±1 digit max. The indication accuracy of W thermocouples is
(±0.3% of PV or ±3°C, whichever is greater) ±1 digit max. The indication accuracy of PL II thermocouples is (±0.3% of PV or ±2°C, whichever is greater) ±1 digit max.
*2. Only four set points are selectable for event inputs.
*3. Simple transfer output, and work bit message are only for E5GC.
14
E5_C
General purpose temperature controllers
High performance & DIN-Track Mounting
The next generation E5_C temperature controller is setting a new global standard in
terms of precision and user-friendly design. Best control performance, easy set-up
and outstanding visibility of the white LCD display have been integrated into a
space-saving housing.
•
•
•
•
Specifications
Fast and precise regulation: 50ms sampling loop period time
Easy to set up, and operate intuitively via CX-Thermo without power supply
Removable terminal block for easy mounting and replacement.*
Useful alarm and diagnosis functions for secure operation
* Only for E5DC
E5CC-U
E5DC
Power supply voltage
A in model number: 100 to 240 VAC, 50/60 Hz D in model number: 24 VAC, 50/60 Hz; 24 VDC
Operating voltage range
85% to 110% of rated supply voltage
Power consumption
Models with option selection of 000: 5.2 VA max. at 100 to 240 VAC,
and 3.1 VA max. at 24 VAC or 1.6 W max. at 24 VDC
All other models: 6.5 VA max. at 100 to 240 VAC, and 4.1 VA max.
at 24 VAC or 2.3 W max. at 24 VDC
Sensor input
– Temperature input
Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II
Platinum resistance thermometer: Pt100 or JPt100
Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C
4.9 VA max. at 100 to 240 VAC,
and 2.8 VA max. at 24 VDC or 1.5 W max. at 24 VDC
– Analog input
Current input: 4 to 20 mA or 0 to 20 mA
Voltage input: 1 to 5 V, 0 to 5 V, 0 to 10 V,or 0 to 50 mV
(The 0 to 50 mV range applies to the E5CC-U only for those manufactured in May 2014 or later.)
Input impedance
Current input: 150 Ω max., Voltage input: 1 MΩ min. (Use a 1: 1 connection when connecting the ES2-HB/THB.)
Control method
ON/OFF control or 2-PID control (with auto-tuning)
Thermocouple:
(±1% of indication value or ±2°C, whichever is greater) ±1 digit max.*1
Platinum resistance thermometer:
(±0.2% of indication value or ±0.8°C, whichever is greater) ±1 digit max.
Analog input: ±0.2% FS ±1 digit max.
Indication accuracy
(at the ambient temperature of 23°C)
(When mounted individually for E5DC)
Auto-Tuning
Thermocouple:
(±0.3% of indication value or ±1°C, whichever is greater) ±1 digit max.*1
Platinum resistance thermometer:
(±0.2% of indication value or ±0.8°C, whichever is greater) ±1 digit max.
Analog input: ±0.2% FS ±1 digit max.
CT input: ±5% FS ±1 digit max.
Yes, 40%/100% MV output limit selection. When using Heat/Cool: Independent Heat & cool PID can be set by Auto-tuning.
Yes
Self-Tuning
Control output Relay output
SPDT, 250 VAC, 3 A (resistive load), electrical life:
100,000 operations, minimum applicable load:
5 V, 10 mA (reference value)
SPST-NO, 250 VAC, 3 A (resistive load), electrical life;
100,000 operations minimum applicable load:
5 V, 10 mA (reference value)
Voltage output (for driving SSR) Output voltage 12 VDC ±20% (PNP), max. load current: 21 mA, with short-circuit protection circuit
Linear current output
Auxiliary output Number of outputs
Event input
4 to 20 mA DC/0 to 20 mA DC, load: 500 Ω max., resolution: approx. 10,000
1 or 2 (depends on model)
2 (depends on model)
Output specifications
SPST-NO relay outputs, 250 VAC,
Models with 1 or 2 outputs: 3 A (resistive load), or Models with 3
outputs: 2 A (resistive load), Electrical life: 100,000 operations,
Minimum applicable load: 10 mA at 5 V (reference value)
SPST-NO relay outputs, 250 VAC,
2 A (resistive load), Electrical life: 100,000 operations,
Minimum applicable load: 10mA at 5V (reference value)
Number of inputs
External contact input
specifications
-
1 (depends on model)
Contact input: ON: 1 kΩ max., OFF: 100 kΩ min.
Setting method
Indication method
Multi SP
Other functions
Ambient operating temperature
Ambient operating humidity
Storage temperature
Degree of protection
Input sampling period
Size in mm (HxWxD)
-
Non-contact input:
ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
Current flow: Approx. 7 mA per contact
Digital setting using front panel keys
11-segment digital display and individual indicators
Up to eight set points (SP0 to SP7) can be saved and selected using
Up to eight set points (SP0 to SP7) can be saved and selected using
the event inputs, key operations, or serial communications.
the event inputs, key operations, or serial communications.*2
Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burnout (HB) alarm (including SSR failure
(HS) alarm), 40% AT, 100% AT, MV limiter, input digital filter, self tuning, robust tuning, PV input shift, run/stop, protection functions, extraction
of square root, MV change rate limit, logic operations, temperature status display, simple programming, moving average of input value, and
display brightness setting
–10 to 55°C (with no condensation or icing), for 3-year warranty: -10 to 50°C with standard mounting (with no condensation or icing)
25% to 85%
–25 to 65°C (with no condensation or icing)
Front panel: IP50, Rear case: IP20, Terminals: IP00
Main unit: IP20, Terminal unit: IP00
50 ms
48×48×76.8
96×22.5×85
Note: *1. The indication accuracy of K thermocouples in the -200 to 1,300°C range, T and N thermocouples at a temperature of -100°C max., and U and L thermocouples at any temperatures is
±2°C ±1 digit max. The indication accuracy of the B thermocouple at a temperature of 400°C max. is not specified. The indication accuracy of B thermocouples at a temperature of
400 to 800°C is ±3°C max. The indication accuracy of the R and S thermocouples at a temperature of 200°C max. is ±3°C ±1 digit max. The indication accuracy of W thermocouples is
(±0.3% of PV or ±3°C, whichever is greater) ±1 digit max. The indication accuracy of PL II thermocouples is (±0.3% of PV or ±2°C, whichever is greater) ±1 digit max.
*2. Only two set points are selectable for event inputs.
15
E5_C
General purpose temperature controllers
USB communication cable E58-CIFQ2
E5GC
E5CC
E5EC
E5AC
E5CC-U
E5DC
E58-CIFQ2






E58-CIFQ2-E

–


–

E58-CIFQ2
E58-CIFQ2-E
Exchange this head for E5GC/E5EC/E5AC/E5DC
E5GC/E5CC/E5EC/E5AC/E5CC-U/E5DC optional tools
Option
Order code
USB based configuration cable
E58-CIFQ2, E58-CIFQ2-E (for E5GC/E5EC/E5AC/E5DC)
PC based configuration and tuning software
EST2-2C-MV4
Refer to the E5 C/E5 C-T Digital Temperature Controllers Datasheet (Cat. No. H177) for details.
OMRON Corporation
Tokyo, JAPAN
Industrial Automation Company
Authorized Distributor:
Contact: www.ia.omron.com
Regional Headquarters
OMRON EUROPE B.V.
Wegalaan 67-69-2132 JD Hoofddorp
The Netherlands
Tel: (31)2356-81-300/Fax: (31)2356-81-388
OMRON ELECTRONICS LLC
One Commerce Drive Schaumburg,
IL 60173-5302 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
© OMRON Corporation 2011-2014 All Rights Reserved.
In the interest of product improvement,
specifications are subject to change without notice.
CSM_8_1_0614
Cat. No. H176-E1-06
0614(1111)