TL-N/TL-Q - OMRON Industrial Automation

Rectangular Standard Proximity Sensor
TL-N/TL-Q
CSM_TL-N/TL-Q_DS_E_11_1
A Wealth of Models for All Types of
Applications
• Easy installation, high-speed pulse generator, high-speed
rotation control, and more.
• Direct mounted to metal (-N Models).
• A wealth of models ideal for limit control, counting control, and
other applications (-N Models).
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Ordering Information
Sensors [Refer to Dimensions on page 10.]
DC 2-Wire Models
Model
Appearance
Sensing distance
Operation mode
NO
17 × 17
Unshielded
25 × 25
5 mm
7 mm
30 × 30
12 mm
40 × 40
20 mm
NC
TL-Q5MD1 2M *1 *2
TL-Q5MD2 2M *1
TL-N7MD1 2M *1
TL-N7MD2 2M *1
TL-N12MD1 2M *1
TL-N12MD2 2M *1
TL-N20MD1 2M *1
TL-N20MD2 2M *1
*1. Models with a different frequency are available to prevent mutual interference. The model numbers are TL-N@MD@5 and TL-Q5MD@5 (e.g., TL-N7MD15).
*2. Models are also available with robotics (bend resistant) cables . Add “-R” to the model number. (e.g., TL-Q5MD1-R 2M)
DC 3-Wire and AC 2-Wire Models
Model
Appearance
8×9
Sensing distance
2 mm
5 mm
25 × 25
5 mm
Unshielded
40 × 40
Operation mode
NO
NC
TL-Q2MC1 2M
—
DC 3-wire, NPN
17 × 17
30 × 30
Output configuration
TL-Q5MC1 2M *1 *2
TL-Q5MC2 2M
DC 3-wire, NPN
TL-N5ME1 2M *1 *2
TL-N5ME2 2M *1
AC 2-wire
TL-N5MY1 2M *1
TL-N5MY2 2M *1
DC 3-wire, NPN
TL-N10ME1 2M *1 *2
TL-N10ME2 2M *1
AC 2-wire
TL-N10MY1 2M *1
TL-N10MY2 2M *1
DC 3-wire, NPN
TL-N20ME1 2M *1 *2
TL-N20ME2 2M *1
AC 2-wire
TL-N20MY1 2M *1
TL-N20MY2 2M *1
10 mm
20 mm
*1. Models with a different frequency are available to prevent mutual interference. The model numbers are TL-@@M@@5 (e.g., TL-N5ME15).
*2. Models are also available with robotics (bend resistant) cables . Add “-R” to the model number. (e.g., TL-Q5MC1-R 2M)
1
TL-N/TL-Q
Accessories (Order Separately)
Mounting Brackets A Mounting Bracket is provided with the Sensor depending on the model number. Check the column for the applicable Sensor.
[Refer to Dimensions on page 11.]
Type
Model
Mounting Brackets
Mounting Brackets for Conduits
Applicable Sensors
Provided with these Sensors
Order separately
Y92E-C5
TL-N5ME@, TL-N7MD@
TL-N5MY@
Y92E-C10
TL-N10ME@, TL-N12MD@
TL-N10MY@
Y92E-C20
TL-N20ME@, TL-N20MD@
TL-N20MY@
Y92E-N5C15
---
TL-N5ME@, TL-N5MY@
Y92E-N10C15
---
TL-N10ME@, TL-N10MY@
Ratings and Specifications
DC 2-Wire Models
Item
Model
TL-Q5MD@
TL-N7MD@
TL-N12MD@
TL-N20MD@
Sensing distance
5 mm ±10%
7 mm ±10%
12 mm ±10%
20 mm ±10%
Set distance
0 to 4 mm
0 to 5.6 mm
0 to 9.6 mm
0 to 16 mm
Differential travel
10% max. of sensing distance
Detectable object
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 5.)
Standard sensing
object
Iron, 18 × 18 × 1 mm
Response
frequency *
500 Hz
Power supply voltage
(operating voltage
range)
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
Leakage current
0.8 mA max.
Control
output
Iron, 30 × 30 × 1 mm
Iron, 40 × 40 × 1 mm
Iron, 50 × 50 × 1 mm
300 Hz
Load
current
3 to 100 mA
Residual
voltage
3.3 V max. (Load current: 100 mA, Cable length: 2 m)
Indicators
D1 Models: Operation indicator (red), Setting indicator (green)
D2 Models: Operation indicator (red)
Operation mode
(with sensing object
approaching)
D1 Models: NO
D2 Models: NC Refer to the timing charts under I/O Circuit Diagrams on page 7 for details.
Protection circuits
Load short-circuit protection, Surge suppressor
Ambient
temperature range
Operating/Storage: −25 to 70°C (with no icing or condensation)
Ambient
humidity range
Operating/Storage: 35% to 95% (with no condensation)
Temperature influence ±10% max. of sensing distance at 23°C in the temperature range of −25 to 70°C
Voltage influence
±2.5% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance
50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength
1,000 VAC for 1 min between current-carrying parts and case
Vibration
resistance
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
Destruction: 500 m/s2 3 times
each in X, Y, and Z directions
Degree of protection
IEC 60529 IP67, in-house standards: oil-resistant
Connection method
Pre-wired Models (Standard cable length: 2 m)
Weight (packed state)
Approx. 85 g
Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions
Approx. 165 g
Approx. 235 g
Approx. 330 g
Mounting Bracket,
Mounting phillips screws (M4 ✕ 25),
Instruction manual
Mounting Bracket,
Mounting phillips screws (M4 ✕ 30),
Instruction manual
Mounting Bracket,
Mounting phillips screws (M5 ✕ 40),
Instruction manual
Case
Materials Sensing
surface
Heat-resistant ABS
Accessories
Instruction manual
* The response frequency is an average value.
Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
2
TL-N/TL-Q
DC 3-Wire Models
Item
Model
TL-Q2MC1
TL-Q5MC@
Sensing
distance
2 mm ±15%
5 mm ±10%
Set distance
0 to 1.5 mm
0 to 4 mm
Differential travel
10% max. of sensing distance
Detectable object
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 6.)
Standard
sensing object
Iron, 8 × 8 × 1 mm
Response time
Iron, 15 × 15 × 1 mm
---
Response
frequency *
2 ms max.
500 Hz
Power supply voltage (operating volt- 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
age range)
Current
consumption
Control
output
15 mA max. at 24 VDC (no-load)
10 mA max. at 24 VDC
Load
current
NPN open collector
100 mA max. at 30 VDC max.
NPN open collector
50 mA max. at 30 VDC max.
Residual
voltage
1 V max. (under load current of 100 mA with cable length of 1 V max. (under load current of 50 mA with cable length of
2 m)
2 m)
Indicators
Detection indicator (red)
C1 Models: NO
Operation mode
NO
C2 Models: NC
(with sensing object
approaching)
Refer to the timing charts under DC 3-Wire Models on page 8 for details.
Protection
circuits
Reverse polarity protection, Surge suppressor
Ambient
temperature range
Operating/Storage: −10 to 60°C (with no icing or condensa- Operating/Storage: −25 to 70°C (with no icing or condensation)
tion)
Ambient
humidity range
Operating/Storage: 35% to 95% (with no condensation)
Temperature
influence
±10% max. of sensing distance at 23°C in the temperature
range of −10 to 60°C
Voltage
influence
±2.5% max. of sensing distance at rated voltage in rated voltage ±10% range
Insulation
resistance
50 MΩ min. (at 500 VDC) between current-carrying parts
and case
5 MΩ min. (at 500 VDC) between current-carrying parts and
case
Dielectric strength
1,000 VAC for 1 min between current-carrying parts and
case
500 VAC, 50/60 Hz for 1 min between current-carrying parts
and case
Vibration
resistance
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
Destruction: 1,000 m/s2 10 times each in X, Y, and Z direc- Destruction: 200 m/s2 10 times each in X, Y, and Z directions
tions
Degree of
protection
IEC 60529 IP67,
in-house standards: oil-resistant
Connection
method
Pre-wired Models (Standard cable length: 2 m)
Weight
(packed state)
Approx. 60 g
Materials
±20% max. of sensing distance at 23°C in the temperature
range of −25 to 70°C
IEC IP67
Approx. 90 g
Case
Sensing
surface
Accessories
Heat-resistant ABS
Instruction manual
---
* The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and
a set distance of half the sensing distance.
3
TL-N/TL-Q
Item
Model
TL-N5ME@, TL-N5MY@
TL-N10ME@, TL-N10MY@
TL-N20ME@, TL-N20MY@
Sensing distance
5 mm ±10%
10 mm ±10%
20 mm ±10%
Set distance
0 to 4 mm
0 to 8 mm
0 to 16 mm
Differential travel
15% max. of sensing distance
Detectable object
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on pages 6 and 7.)
Standard
sensing object
Iron, 30 × 30 × 1 mm
Response
frequency *1
E Models: 500 Hz
Y Models: 10 Hz
Power supply
voltage *2
(operating voltage
range)
E Models: 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
Y Models: 100 to 220 VAC (90 to 250 VAC), 50/60 Hz
Current
consumption
E Models: 8 mA max. at 12 VDC, 15 mA max. at 24 VDC
Leakage current
Y Models: Refer to Engineering Data on page 5.
Control
output
Iron, 40 × 40 × 1 mm
E Models: 40 Hz
Y Models: 10 Hz
Load
current
E Models: 100 mA max. at 12 VDC, 200 mA max. at 24 VDC
Y Models: 10 to 200 mA
Residual
voltage
E Models: 1 V max. (load current: 200 mA)
Y Models: Refer to Engineering Data on page 5.
Indicators
Operation mode
(with sensing object approaching)
Iron, 50 × 50 × 1 mm
E Models: Detection indicator (red)
Y Models: Operation indicator (red)
E1/Y1 Models: NO
E2/Y2 Models: NC
Refer to the timing charts under I/O Circuit Diagrams on page 8 for details.
Protection circuits
E Models: Reverse polarity protection, Surge suppressor
Y Models: Surge suppressor
Ambient
temperature range
Operating/Storage: −25 to 70°C (with no icing or condensation)
Ambient
humidity range
Operating/Storage: 35% to 95% (with no condensation)
Temperature
influence
±10% max. of sensing distance at 23°C in the temperature range of −25 to 70°C
Voltage influence
E Models: ±2.5% max. of sensing distance at rated voltage in rated voltage ±10% range
Y Models: ±1% max. of sensing distance at rated voltage in rated voltage ±10% range
Insulation
resistance
50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength
E Models: 1,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Y Models: 2,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Vibration
resistance
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
Destruction: 500 m/s2 10 times each in X, Y, and Z directions
Degree of
protection
IEC 60529 IP67, in-house standards: oil-resistant
Connection
method
Pre-wired Models (Standard cable length: 2 m)
Weight
(packed state)
Approx. 190 g
Materials
Approx. 240 g
Approx. 340 g
E Models: Mounting Bracket,
E Models: Mounting Bracket,
Case
Sensing
surface
Heat-resistant ABS
E Models: Mounting Bracket,
Accessories
Mounting phillips screws (M4 ✕ 25),
Instruction manual
Y Models: Instruction manual
Mounting phillips screws (M4 ✕ 30),
Instruction manual
Y Models: Instruction manual
Mounting phillips screws (M5 ✕ 40),
Instruction manual
Y Models: Instruction manual
*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and
a set distance of half the sensing distance.
*2. E Models (DC switching models): A full-wave rectification power supply of 24 VDC ±10% (average value) can be used.
4
TL-N/TL-Q
Engineering Data (Reference Value)
Y
X
4
TL-Q5M@@
TL-N@ME@
TL-N@MY@
Distance X (mm)
Distance X (mm)
TL-Q2MC1
Distance X (mm)
Sensing Area
5
20
TL-N20
4
3
15
Y
X
3
10
2
2
TL-N10
Y
TL-N5
X
1
0
−8
5
1
−6
−4
−2
0
2
4
Sensing Head
0
6
Distance Y (mm)
−8
−6
−4
−2
0
2
4
6
0
−25 −20 −15 −10
8
−5
0
5
10
TL-N5 Sensing Head
TL-N10 Sensing Head
TL-N20 Sensing Head
Sensing Head
Distance Y (mm)
15
20
Distance Y (mm)
Leakage Current
20
TL-N@MY
Leakage current (mA)
Distance X (mm)
TL-N@MD@
TL-N20MD@
15
2.0
1.5
TL-N12MD@
1.0
10
Y
TL-N7MD@
mA
X
5
Protective resistance
AC
power
50/60
Hz
V
0.5
Proximity Sensor
(output OFF)
0
-25
-20
-15 -10
-5
0
5
10
TL-N7MD@ Sensing Head
TL-N12MD@ Sensing Head
TL-N20MD@ Sensing Head
15
0
20
Distance Y (mm)
80 100 120 140 160 180 200 220 240 260
Power supply voltage (V)
5
4
TL-N@MY at 100 VAC
TL-N@MY at 200 VAC
Load voltage VL (V)
Residual output voltage (V)
TL-N@MD
Load voltage VL (V)
Residual Output Voltage
Residual output voltage
100
ON
80
3
ON
160
V
V
120
60
2
A
40
1
100 VAC
3
5
10
30 50 100
300 500 1,000
Load current (mA)
0
A
80
200 VAC
40
20
Residual
load voltage
0
Residual output voltage
200
3
5
10
20
OFF
30 50 100 200
Load current (mA)
Residual
load
voltage
0
3 5
10
20
50
OFF
100 200
Load current (mA)
5
TL-N/TL-Q
Sensing Object Size vs. Sensing Distance
Distance X (mm)
TL-Q5MC@
7
t = 1 mm
6
5
d×
d
4
X
3
2
1
0
10
20
30
40
Side length of sensing object: d (mm)
Influence of Sensing Object Size and Material
d×
d
X
3
6
TL-N5@
d×
d
X
5
Iron
4
2
Distance X (mm)
TL-Q5M@@
4
Distance X (mm)
Distance X (mm)
TL-Q2MC1
Stainless steel
(SUS304)
2
Brass
Stainless steel
(SUS304)
2
Aluminum
Copper
Aluminum
1
1
Aluminum
Brass
0
5
10
d×
d
X t = 1 mm
8
Iron
Distance X (mm)
TL-N12MD@
10
14
d×
d
12
10
20
30
40
50
60 70
80
Side length of sensing object: d (mm)
TL-N20MD@
t = 1 mm
X
0
15
20
25
30 35
40 45
Side length of sensing object: d (mm)
Iron
10
Distance X (mm)
20
30
40
50
60
Side length of sensing object: d (mm)
TL-N7MD@
Distance X (mm)
Iron
3
Brass
10
5
4
Stainless steel
(SUS304)
0
t = 1 mm
X
3
Iron
1
d×
d
6
24
d×
d
X
20
t = 1 mm
Iron
16
6
8
Stainless steel
(SUS304)
Stainless steel
(SUS304)
6
4
8
Copper
4
2
10
20
30
40
50
60
Side length of sensing object: d (mm)
0
Copper
Aluminum
Copper
Aluminum
4
Aluminum
0
Brass
Brass
Brass
2
Stainless steel
(SUS304)
12
10
20
30
40
50
60
Side length of sensing object: d (mm)
0
10
20
30
40
50
60
Side length of sensing object: d (mm)
6
TL-N/TL-Q
TL-N20@
d×
d
X
10
t = 1 mm
Distance X (mm)
Distance X (mm)
TL-N10@
Iron
22
d×
d
t = 1 mm
Iron
X
20
18
16
8
14
6
12
Stainless steel
(SUS304)
4
Stainless steel
(SUS304)
10
8
Brass
Brass
6
Aluminum
2
Aluminum
4
2
0
10
20
0
30
40
50
60 70
80
Side length of sensing object: d (mm)
10
20
30
40
50
60 70
80
Side length of sensing object: d (mm)
I/O Circuit Diagrams
DC 2-Wire Models
Operation
mode
Model
Timing chart
Output circuit
Unstable Set position
Stable sensing
Non-sensing sensing
area
area
area
Proximity Sensor
Sensing
object
NO
TL-Q5MD1
TL-N7MD1
TL-N12MD1
TL-N20MD1
(%)
100 80 (TYP)
0
Rated
sensing
distance
ON
OFF
ON
OFF
Setting indicator
(green)
ON
Control output
OFF
Sensing
area
Non-sensing
area
Sensing
object
NC
(%)
100
Load
+V
Proximity
Sensor
main
circuit
Blue
Proximity Sensor
TL-Q5MD2
TL-N7MD2
TL-N12MD2
TL-N20MD2
Brown
Operation indicator
(red)
0V
Note: The load can be connected to either
the +V or 0 V side.
0
Rated
sensing
distance
ON Operation indicator
OFF (red)
ON
Control output
OFF
7
TL-N/TL-Q
DC 3-Wire Models
Operation
mode
Model
Timing chart
Output circuit
Present
Sensing object
Not present
NO
TL-Q2MC1
TL-Q5MC1
ON
Output transistor
(load)
OFF
Brown
ON
Detection indicator
(red)
OFF
Load
Proximity
Sensor
main
circuit
Black*
Output
Present
Sensing object
Blue
Not present
NC
TL-Q5MC2
ON
Output transistor
(load)
OFF
Detection indicator
(red)
OFF
TL-N5ME1
TL-N10ME1
TL-N20ME1
0V
* Load current: 100 mA max., TL-Q2MC1
Load current: 50 mA max., TL-Q5MC1
ON
Present
Sensing object
NO
+V
100 Ω
Not present
Load (between brown
and black leads)
Operate
Brown
Reset
Output voltage (between
black and blue leads)
Load
Low
ON
Detection indicator (red)
+V
100 Ω
High
Proximity
Sensor
main
circuit
OFF
4.7 kΩ
*1
Black
2.2 Ω
Output
*2
Tr
Present
Sensing object
NC
TL-N5ME2
TL-N10ME2
TL-N20ME2
Not present
Blue
0V
Operate
Load (between brown
and black leads)
Reset
Output voltage (between
black and blue leads)
Detection indicator (red)
*1. Load current: 200 mA max.
*2. When a transistor is connected.
High
Low
ON
OFF
AC 2-Wire Models
Operation
mode
Model
Timing chart
Sensing object
NO
TL-N5MY1
TL-N10MY1
TL-N20MY1
Output circuit
Present
Not present
Load
Operate
Reset
Operation indicator (red)
Brown
Load
ON
OFF
Proximity
Sensor
main
circuit
Sensing object
NC
TL-N5MY2
TL-N10MY2
TL-N20MY2
Present
Blue
Not present
Load
Operate
Reset
Operation indicator (red)
ON
OFF
8
TL-N/TL-Q
Safety Precautions
Refer to Warranty and Limitations of Liability.
WARNING
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
• Do not short-circuit the load, otherwise the Sensor may
be damaged.
• Do not supply power to the Sensor with no load,
otherwise the Sensor may be damaged.
Applicable Models: AC 2-Wire Models
Precautions for Correct Use
Do not use this product under ambient conditions that exceed the
ratings.
● Design
Influence of Surrounding Metal
Mutual Interference
When mounting the Sensor within a metal panel, ensure that the
clearances given in the following table are maintained. Failure to
maintain these distances may cause deterioration in the performance
of the Sensor.
Rectangular Models TL-N*2
When installing Sensors face-to-face or side-by-side, ensure that the
minimum distances given in the following table are maintained.
Parallel
Face-to-face
A
TL-Q
B *1
B *1
A
A
B
Mutual Interference (Unit: mm)
Influence of Surrounding Metal (Unit: mm)
Model
TL-Q5M@@
TL-N7MD@
TL-N12MD@
TL-N20MD@
TL-N5ME@, TL-N5MY@
TL-N10ME@, TL-N10MY@
TL-N20ME@, TL-N20MY@
Distance
A
20
40
50
70
20
40
80
B *1
20
35
40
60
23
30
45
Model
TL-Q5MC@
TL-Q5MD@
TL-N7MD@
TL-N12MD@
TL-N20MD@
TL-N5ME@
TL-N5MY@
TL-N10ME@, TL-N10MY@
TL-N20ME@, TL-N20MY@
B*
120 (60)
120 (80)
120 (60)
200 (100)
200 (100)
80 (40)
90 (40)
120 (60)
120 (60)
A
B
B
TL-Q2MC1
Mounting plate*
3 mm
A*
60 (17)
60 (30)
100 (50)
120 (60)
200 (100)
80 (40)
80 (40)
120 (60)
200 (100)
* Values in parentheses apply to Sensors operating at different frequencies.
*1. The B dimension applies to the top, right-side, and left-side surfaces.
*2. The values for A or B for the TL-N apply when there is metal on only one side
of the sensor. If there is metal on two or more sides of the sensor, the value
must be multiplied by two or more.
A
Distance
TL-Q2MC1
* The mounting plate
must be a nonferrous metal.
Distance
Distance
A*
30 (8)
B*
90 (45)
* Values in parentheses apply to Sensors operating at different frequencies.
Influence of Surrounding Metal (Unit: mm)
Model
TL-Q2MC1
Mutual Interference (Unit: mm)
Model
TL-Q2MC1
B
A
12
B
3
● Mounting
When tightening the mounting screws, do not exceed the torque in the
following table.
Model
TL-Q2MC1
TL-Q5M@@
TL-N@M@@
Torque
0.59 N·m
0.9 to 1.5 N·m
9
TL-N/TL-Q
(Unit: mm)
Dimensions
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
Sensors
TL-Q2MC1
1
*
6
Detection indicator (red)
Sensing surface
3.2-dia. mounting hole
18.5±0.2
8
2.5
8
9
25
28
* 2.9-dia. vinyl-insulated round cable with 3 conductors
(Conductor cross section: 0.15 mm2, Insulator diameter:
0.9 mm), Standard length: 2 m
TL-Q5M@@
32 max.
28
17
Mounting Hole
Dimensions
3.5
*1
17
10.5±0.1
Two, 3.3-dia. holes
Two, 3.3 dia.
Indicators *2
16
3
10.5±0.1
*1. C Models: 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.2 mm2,
Insulator diameter: 1.2 mm), Standard length: 2 m
D Models: 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2,
Insulator diameter: 1.3 mm), Standard length: 2 m
*2. C Models: Detection indicator (red)
D Models: Operation indicator (red), Setting indicator (green)
TL-N7MD@, TL-N5ME@
35
Two, 4.3 dia.
18±0.45
25
8 dia. 9 dia.
6
23.8
Rubber bushing
Mounting Hole Dimensions
25
Two, 4.5-dia. or M4 holes
18.5
0.5
18±0.2
Indicator *2
38.5
*1
18.5
1.5
*1. D Models: 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.9 mm), Standard length: 2 m
E Models: 6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.9 mm), Standard length: 2 m
*2. D1 Models: Operation indicator (red), Setting indicator (green)
D2 Models: Operation indicator (red)
E Models: Detection indicator (red)
TL-N5MY@
TL-N12MD@,
TL-N10ME@,
TL-N10MY@
46.3
48.5
Two, 4.3 dia.
30
25
22±0.45
8 dia. 9 dia.
18±0.45
7.7
6.2
34.1
Mounting Hole
Dimensions
18±0.2
21.5
Two, 4.5-dia. or M4 holes
18.5
0.5
50
Indicator *2
Rubber bushing
30
Rubber bushing
25
35.8
8 dia. 9 dia.
Operation indicator (red)
Mounting Hole Dimensions
Two, 4.5-dia. or M4 holes
Two, 4.3 dia.
18.5
1.5
* 6-dia. vinyl-insulated round cable with 2 conductors
(Conductor cross section: 0.5 mm2, Insulator diameter:
1.9 mm), Standard length: 2 m
0.5
*
22±0.2
52.5
18.5
1.5
*1
*1. D/Y Models: 6-dia. vinyl-insulated round cable with 2 conductors
(Conductor cross section: 0.5 mm2, Insulator
diameter: 1.9 mm), Standard length: 2 m
E Models: 6-dia. vinyl-insulated round cable with 3
conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.9 mm), Standard length: 2 m
*2. D1 Models: Operation indicator (red) and Setting indicator (green)
D2 Models: Operation indicator (red)
E Models: Detection indicator (red)
Y Models: Operation indicator (red)
10
TL-N/TL-Q
TL-N20MD@, TL-N20ME@, TL-N20MY@
47
Mounting Hole Dimensions
Two, 5.5 dia.
Two, 5.5-dia. or M5 holes
10 dia. 12 dia. 30±0.45
40
30±0.2
8
Indicator *2
31.8
Rubber bushing
*1
40
30
53
1
25
*1. D/Y Models: 6-dia. vinyl-insulated round cable with 2 conductors
(Conductor cross section: 0.5 mm2, Insulator
diameter: 1.9 mm), Standard length: 2 m
E Models: 6-dia. vinyl-insulated round cable with 3
conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.9 mm), Standard length: 2 m
*2. D1 Models: Operation indicator (red) and Setting indicator (green)
D2 Models: Operation indicator (red)
E Models: Detection indicator (red)
Y Models: Operation indicator (red)
Accessories (Order Separately)
Mounting Bracket
Y92E-C20
Y92E-C10
Y92E-C5
32
20
34
Two, M4
20
3.5
Two, M5
35
Two, M4
19.5
4
6
5.5
18
4.5
4.5
*1 12
30±0.2
*1 22±0.2
25
18±0.2
±0.2
*1 16±0.2
22±0.2
40
30
9
6.5
2.3
7
9.5
2.3
Applicable Models: TL-N5ME@ *2
Applicable Models: TL-N5MY@
Applicable Models: TL-N7MD@ *2
Material: Mounting Bracket:
Zinc-plated iron
Mounting phillips Screws: Nickel-plated iron
14.5
Applicable Models: TL-N10ME@ *2
Applicable Models: TL-N10MY@
Applicable Models: TL-N12MD@ *2
Material: Mounting Bracket:
Zinc-plated iron
Mounting phillips Screws: Nickel-plated iron
3.2
24
Applicable Models: TL-N20ME@ *2
Applicable Models: TL-N20MY @
Applicable Models: TL-N20MD@ *2
Material: Mounting Bracket:
Zinc-plated iron
Mounting phillips Screws: Nickel-plated iron
*1. These are the mounting dimensions of the base of the Mounting Bracket.
*2. Provided with the product.
Mounting Brackets for Wiring Conduit Use (Sold Separately)
Y92E-N10C15
Y92E-N5C15
18
2.3
25
18±0.3
11±0.2
Two, 4.3 dia.
21
3.5
5
23.8
2.3
C15 conduit screw, JIS-B-0204
Applicable Models: TL-N5ME@
Applicable Models: TL-N5MY@
Applicable Models: TL-N7MD@
Material: Zinc-plated iron
2.3
30
22±0.3
13±0.2
Two, 4.3 dia.
3.5
5.5
24.3
2.3
C15 conduit screw, JIS-B-0204
Applicable Models: TL-N10ME@
Applicable Models: TL-N10MY@
Applicable Models: TL-N12MD@
Material: Zinc-plated iron
11
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2014.9
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2014 All Right Reserved.