Rectangular Standard Proximity Sensor TL-N/TL-Q CSM_TL-N/TL-Q_DS_E_11_1 A Wealth of Models for All Types of Applications • Easy installation, high-speed pulse generator, high-speed rotation control, and more. • Direct mounted to metal (-N Models). • A wealth of models ideal for limit control, counting control, and other applications (-N Models). For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Ordering Information Sensors [Refer to Dimensions on page 10.] DC 2-Wire Models Model Appearance Sensing distance Operation mode NO 17 × 17 Unshielded 25 × 25 5 mm 7 mm 30 × 30 12 mm 40 × 40 20 mm NC TL-Q5MD1 2M *1 *2 TL-Q5MD2 2M *1 TL-N7MD1 2M *1 TL-N7MD2 2M *1 TL-N12MD1 2M *1 TL-N12MD2 2M *1 TL-N20MD1 2M *1 TL-N20MD2 2M *1 *1. Models with a different frequency are available to prevent mutual interference. The model numbers are TL-N@MD@5 and TL-Q5MD@5 (e.g., TL-N7MD15). *2. Models are also available with robotics (bend resistant) cables . Add “-R” to the model number. (e.g., TL-Q5MD1-R 2M) DC 3-Wire and AC 2-Wire Models Model Appearance 8×9 Sensing distance 2 mm 5 mm 25 × 25 5 mm Unshielded 40 × 40 Operation mode NO NC TL-Q2MC1 2M — DC 3-wire, NPN 17 × 17 30 × 30 Output configuration TL-Q5MC1 2M *1 *2 TL-Q5MC2 2M DC 3-wire, NPN TL-N5ME1 2M *1 *2 TL-N5ME2 2M *1 AC 2-wire TL-N5MY1 2M *1 TL-N5MY2 2M *1 DC 3-wire, NPN TL-N10ME1 2M *1 *2 TL-N10ME2 2M *1 AC 2-wire TL-N10MY1 2M *1 TL-N10MY2 2M *1 DC 3-wire, NPN TL-N20ME1 2M *1 *2 TL-N20ME2 2M *1 AC 2-wire TL-N20MY1 2M *1 TL-N20MY2 2M *1 10 mm 20 mm *1. Models with a different frequency are available to prevent mutual interference. The model numbers are TL-@@M@@5 (e.g., TL-N5ME15). *2. Models are also available with robotics (bend resistant) cables . Add “-R” to the model number. (e.g., TL-Q5MC1-R 2M) 1 TL-N/TL-Q Accessories (Order Separately) Mounting Brackets A Mounting Bracket is provided with the Sensor depending on the model number. Check the column for the applicable Sensor. [Refer to Dimensions on page 11.] Type Model Mounting Brackets Mounting Brackets for Conduits Applicable Sensors Provided with these Sensors Order separately Y92E-C5 TL-N5ME@, TL-N7MD@ TL-N5MY@ Y92E-C10 TL-N10ME@, TL-N12MD@ TL-N10MY@ Y92E-C20 TL-N20ME@, TL-N20MD@ TL-N20MY@ Y92E-N5C15 --- TL-N5ME@, TL-N5MY@ Y92E-N10C15 --- TL-N10ME@, TL-N10MY@ Ratings and Specifications DC 2-Wire Models Item Model TL-Q5MD@ TL-N7MD@ TL-N12MD@ TL-N20MD@ Sensing distance 5 mm ±10% 7 mm ±10% 12 mm ±10% 20 mm ±10% Set distance 0 to 4 mm 0 to 5.6 mm 0 to 9.6 mm 0 to 16 mm Differential travel 10% max. of sensing distance Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 5.) Standard sensing object Iron, 18 × 18 × 1 mm Response frequency * 500 Hz Power supply voltage (operating voltage range) 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. Leakage current 0.8 mA max. Control output Iron, 30 × 30 × 1 mm Iron, 40 × 40 × 1 mm Iron, 50 × 50 × 1 mm 300 Hz Load current 3 to 100 mA Residual voltage 3.3 V max. (Load current: 100 mA, Cable length: 2 m) Indicators D1 Models: Operation indicator (red), Setting indicator (green) D2 Models: Operation indicator (red) Operation mode (with sensing object approaching) D1 Models: NO D2 Models: NC Refer to the timing charts under I/O Circuit Diagrams on page 7 for details. Protection circuits Load short-circuit protection, Surge suppressor Ambient temperature range Operating/Storage: −25 to 70°C (with no icing or condensation) Ambient humidity range Operating/Storage: 35% to 95% (with no condensation) Temperature influence ±10% max. of sensing distance at 23°C in the temperature range of −25 to 70°C Voltage influence ±2.5% max. of sensing distance at rated voltage in the rated voltage ±15% range Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case Dielectric strength 1,000 VAC for 1 min between current-carrying parts and case Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions Shock resistance Destruction: 500 m/s2 3 times each in X, Y, and Z directions Degree of protection IEC 60529 IP67, in-house standards: oil-resistant Connection method Pre-wired Models (Standard cable length: 2 m) Weight (packed state) Approx. 85 g Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions Approx. 165 g Approx. 235 g Approx. 330 g Mounting Bracket, Mounting phillips screws (M4 ✕ 25), Instruction manual Mounting Bracket, Mounting phillips screws (M4 ✕ 30), Instruction manual Mounting Bracket, Mounting phillips screws (M5 ✕ 40), Instruction manual Case Materials Sensing surface Heat-resistant ABS Accessories Instruction manual * The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance. 2 TL-N/TL-Q DC 3-Wire Models Item Model TL-Q2MC1 TL-Q5MC@ Sensing distance 2 mm ±15% 5 mm ±10% Set distance 0 to 1.5 mm 0 to 4 mm Differential travel 10% max. of sensing distance Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 6.) Standard sensing object Iron, 8 × 8 × 1 mm Response time Iron, 15 × 15 × 1 mm --- Response frequency * 2 ms max. 500 Hz Power supply voltage (operating volt- 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. age range) Current consumption Control output 15 mA max. at 24 VDC (no-load) 10 mA max. at 24 VDC Load current NPN open collector 100 mA max. at 30 VDC max. NPN open collector 50 mA max. at 30 VDC max. Residual voltage 1 V max. (under load current of 100 mA with cable length of 1 V max. (under load current of 50 mA with cable length of 2 m) 2 m) Indicators Detection indicator (red) C1 Models: NO Operation mode NO C2 Models: NC (with sensing object approaching) Refer to the timing charts under DC 3-Wire Models on page 8 for details. Protection circuits Reverse polarity protection, Surge suppressor Ambient temperature range Operating/Storage: −10 to 60°C (with no icing or condensa- Operating/Storage: −25 to 70°C (with no icing or condensation) tion) Ambient humidity range Operating/Storage: 35% to 95% (with no condensation) Temperature influence ±10% max. of sensing distance at 23°C in the temperature range of −10 to 60°C Voltage influence ±2.5% max. of sensing distance at rated voltage in rated voltage ±10% range Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case 5 MΩ min. (at 500 VDC) between current-carrying parts and case Dielectric strength 1,000 VAC for 1 min between current-carrying parts and case 500 VAC, 50/60 Hz for 1 min between current-carrying parts and case Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions Shock resistance Destruction: 1,000 m/s2 10 times each in X, Y, and Z direc- Destruction: 200 m/s2 10 times each in X, Y, and Z directions tions Degree of protection IEC 60529 IP67, in-house standards: oil-resistant Connection method Pre-wired Models (Standard cable length: 2 m) Weight (packed state) Approx. 60 g Materials ±20% max. of sensing distance at 23°C in the temperature range of −25 to 70°C IEC IP67 Approx. 90 g Case Sensing surface Accessories Heat-resistant ABS Instruction manual --- * The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance. 3 TL-N/TL-Q Item Model TL-N5ME@, TL-N5MY@ TL-N10ME@, TL-N10MY@ TL-N20ME@, TL-N20MY@ Sensing distance 5 mm ±10% 10 mm ±10% 20 mm ±10% Set distance 0 to 4 mm 0 to 8 mm 0 to 16 mm Differential travel 15% max. of sensing distance Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on pages 6 and 7.) Standard sensing object Iron, 30 × 30 × 1 mm Response frequency *1 E Models: 500 Hz Y Models: 10 Hz Power supply voltage *2 (operating voltage range) E Models: 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. Y Models: 100 to 220 VAC (90 to 250 VAC), 50/60 Hz Current consumption E Models: 8 mA max. at 12 VDC, 15 mA max. at 24 VDC Leakage current Y Models: Refer to Engineering Data on page 5. Control output Iron, 40 × 40 × 1 mm E Models: 40 Hz Y Models: 10 Hz Load current E Models: 100 mA max. at 12 VDC, 200 mA max. at 24 VDC Y Models: 10 to 200 mA Residual voltage E Models: 1 V max. (load current: 200 mA) Y Models: Refer to Engineering Data on page 5. Indicators Operation mode (with sensing object approaching) Iron, 50 × 50 × 1 mm E Models: Detection indicator (red) Y Models: Operation indicator (red) E1/Y1 Models: NO E2/Y2 Models: NC Refer to the timing charts under I/O Circuit Diagrams on page 8 for details. Protection circuits E Models: Reverse polarity protection, Surge suppressor Y Models: Surge suppressor Ambient temperature range Operating/Storage: −25 to 70°C (with no icing or condensation) Ambient humidity range Operating/Storage: 35% to 95% (with no condensation) Temperature influence ±10% max. of sensing distance at 23°C in the temperature range of −25 to 70°C Voltage influence E Models: ±2.5% max. of sensing distance at rated voltage in rated voltage ±10% range Y Models: ±1% max. of sensing distance at rated voltage in rated voltage ±10% range Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case Dielectric strength E Models: 1,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case Y Models: 2,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions Shock resistance Destruction: 500 m/s2 10 times each in X, Y, and Z directions Degree of protection IEC 60529 IP67, in-house standards: oil-resistant Connection method Pre-wired Models (Standard cable length: 2 m) Weight (packed state) Approx. 190 g Materials Approx. 240 g Approx. 340 g E Models: Mounting Bracket, E Models: Mounting Bracket, Case Sensing surface Heat-resistant ABS E Models: Mounting Bracket, Accessories Mounting phillips screws (M4 ✕ 25), Instruction manual Y Models: Instruction manual Mounting phillips screws (M4 ✕ 30), Instruction manual Y Models: Instruction manual Mounting phillips screws (M5 ✕ 40), Instruction manual Y Models: Instruction manual *1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance. *2. E Models (DC switching models): A full-wave rectification power supply of 24 VDC ±10% (average value) can be used. 4 TL-N/TL-Q Engineering Data (Reference Value) Y X 4 TL-Q5M@@ TL-N@ME@ TL-N@MY@ Distance X (mm) Distance X (mm) TL-Q2MC1 Distance X (mm) Sensing Area 5 20 TL-N20 4 3 15 Y X 3 10 2 2 TL-N10 Y TL-N5 X 1 0 −8 5 1 −6 −4 −2 0 2 4 Sensing Head 0 6 Distance Y (mm) −8 −6 −4 −2 0 2 4 6 0 −25 −20 −15 −10 8 −5 0 5 10 TL-N5 Sensing Head TL-N10 Sensing Head TL-N20 Sensing Head Sensing Head Distance Y (mm) 15 20 Distance Y (mm) Leakage Current 20 TL-N@MY Leakage current (mA) Distance X (mm) TL-N@MD@ TL-N20MD@ 15 2.0 1.5 TL-N12MD@ 1.0 10 Y TL-N7MD@ mA X 5 Protective resistance AC power 50/60 Hz V 0.5 Proximity Sensor (output OFF) 0 -25 -20 -15 -10 -5 0 5 10 TL-N7MD@ Sensing Head TL-N12MD@ Sensing Head TL-N20MD@ Sensing Head 15 0 20 Distance Y (mm) 80 100 120 140 160 180 200 220 240 260 Power supply voltage (V) 5 4 TL-N@MY at 100 VAC TL-N@MY at 200 VAC Load voltage VL (V) Residual output voltage (V) TL-N@MD Load voltage VL (V) Residual Output Voltage Residual output voltage 100 ON 80 3 ON 160 V V 120 60 2 A 40 1 100 VAC 3 5 10 30 50 100 300 500 1,000 Load current (mA) 0 A 80 200 VAC 40 20 Residual load voltage 0 Residual output voltage 200 3 5 10 20 OFF 30 50 100 200 Load current (mA) Residual load voltage 0 3 5 10 20 50 OFF 100 200 Load current (mA) 5 TL-N/TL-Q Sensing Object Size vs. Sensing Distance Distance X (mm) TL-Q5MC@ 7 t = 1 mm 6 5 d× d 4 X 3 2 1 0 10 20 30 40 Side length of sensing object: d (mm) Influence of Sensing Object Size and Material d× d X 3 6 TL-N5@ d× d X 5 Iron 4 2 Distance X (mm) TL-Q5M@@ 4 Distance X (mm) Distance X (mm) TL-Q2MC1 Stainless steel (SUS304) 2 Brass Stainless steel (SUS304) 2 Aluminum Copper Aluminum 1 1 Aluminum Brass 0 5 10 d× d X t = 1 mm 8 Iron Distance X (mm) TL-N12MD@ 10 14 d× d 12 10 20 30 40 50 60 70 80 Side length of sensing object: d (mm) TL-N20MD@ t = 1 mm X 0 15 20 25 30 35 40 45 Side length of sensing object: d (mm) Iron 10 Distance X (mm) 20 30 40 50 60 Side length of sensing object: d (mm) TL-N7MD@ Distance X (mm) Iron 3 Brass 10 5 4 Stainless steel (SUS304) 0 t = 1 mm X 3 Iron 1 d× d 6 24 d× d X 20 t = 1 mm Iron 16 6 8 Stainless steel (SUS304) Stainless steel (SUS304) 6 4 8 Copper 4 2 10 20 30 40 50 60 Side length of sensing object: d (mm) 0 Copper Aluminum Copper Aluminum 4 Aluminum 0 Brass Brass Brass 2 Stainless steel (SUS304) 12 10 20 30 40 50 60 Side length of sensing object: d (mm) 0 10 20 30 40 50 60 Side length of sensing object: d (mm) 6 TL-N/TL-Q TL-N20@ d× d X 10 t = 1 mm Distance X (mm) Distance X (mm) TL-N10@ Iron 22 d× d t = 1 mm Iron X 20 18 16 8 14 6 12 Stainless steel (SUS304) 4 Stainless steel (SUS304) 10 8 Brass Brass 6 Aluminum 2 Aluminum 4 2 0 10 20 0 30 40 50 60 70 80 Side length of sensing object: d (mm) 10 20 30 40 50 60 70 80 Side length of sensing object: d (mm) I/O Circuit Diagrams DC 2-Wire Models Operation mode Model Timing chart Output circuit Unstable Set position Stable sensing Non-sensing sensing area area area Proximity Sensor Sensing object NO TL-Q5MD1 TL-N7MD1 TL-N12MD1 TL-N20MD1 (%) 100 80 (TYP) 0 Rated sensing distance ON OFF ON OFF Setting indicator (green) ON Control output OFF Sensing area Non-sensing area Sensing object NC (%) 100 Load +V Proximity Sensor main circuit Blue Proximity Sensor TL-Q5MD2 TL-N7MD2 TL-N12MD2 TL-N20MD2 Brown Operation indicator (red) 0V Note: The load can be connected to either the +V or 0 V side. 0 Rated sensing distance ON Operation indicator OFF (red) ON Control output OFF 7 TL-N/TL-Q DC 3-Wire Models Operation mode Model Timing chart Output circuit Present Sensing object Not present NO TL-Q2MC1 TL-Q5MC1 ON Output transistor (load) OFF Brown ON Detection indicator (red) OFF Load Proximity Sensor main circuit Black* Output Present Sensing object Blue Not present NC TL-Q5MC2 ON Output transistor (load) OFF Detection indicator (red) OFF TL-N5ME1 TL-N10ME1 TL-N20ME1 0V * Load current: 100 mA max., TL-Q2MC1 Load current: 50 mA max., TL-Q5MC1 ON Present Sensing object NO +V 100 Ω Not present Load (between brown and black leads) Operate Brown Reset Output voltage (between black and blue leads) Load Low ON Detection indicator (red) +V 100 Ω High Proximity Sensor main circuit OFF 4.7 kΩ *1 Black 2.2 Ω Output *2 Tr Present Sensing object NC TL-N5ME2 TL-N10ME2 TL-N20ME2 Not present Blue 0V Operate Load (between brown and black leads) Reset Output voltage (between black and blue leads) Detection indicator (red) *1. Load current: 200 mA max. *2. When a transistor is connected. High Low ON OFF AC 2-Wire Models Operation mode Model Timing chart Sensing object NO TL-N5MY1 TL-N10MY1 TL-N20MY1 Output circuit Present Not present Load Operate Reset Operation indicator (red) Brown Load ON OFF Proximity Sensor main circuit Sensing object NC TL-N5MY2 TL-N10MY2 TL-N20MY2 Present Blue Not present Load Operate Reset Operation indicator (red) ON OFF 8 TL-N/TL-Q Safety Precautions Refer to Warranty and Limitations of Liability. WARNING This product is not designed or rated for ensuring safety of persons either directly or indirectly. Do not use it for such purposes. • Do not short-circuit the load, otherwise the Sensor may be damaged. • Do not supply power to the Sensor with no load, otherwise the Sensor may be damaged. Applicable Models: AC 2-Wire Models Precautions for Correct Use Do not use this product under ambient conditions that exceed the ratings. ● Design Influence of Surrounding Metal Mutual Interference When mounting the Sensor within a metal panel, ensure that the clearances given in the following table are maintained. Failure to maintain these distances may cause deterioration in the performance of the Sensor. Rectangular Models TL-N*2 When installing Sensors face-to-face or side-by-side, ensure that the minimum distances given in the following table are maintained. Parallel Face-to-face A TL-Q B *1 B *1 A A B Mutual Interference (Unit: mm) Influence of Surrounding Metal (Unit: mm) Model TL-Q5M@@ TL-N7MD@ TL-N12MD@ TL-N20MD@ TL-N5ME@, TL-N5MY@ TL-N10ME@, TL-N10MY@ TL-N20ME@, TL-N20MY@ Distance A 20 40 50 70 20 40 80 B *1 20 35 40 60 23 30 45 Model TL-Q5MC@ TL-Q5MD@ TL-N7MD@ TL-N12MD@ TL-N20MD@ TL-N5ME@ TL-N5MY@ TL-N10ME@, TL-N10MY@ TL-N20ME@, TL-N20MY@ B* 120 (60) 120 (80) 120 (60) 200 (100) 200 (100) 80 (40) 90 (40) 120 (60) 120 (60) A B B TL-Q2MC1 Mounting plate* 3 mm A* 60 (17) 60 (30) 100 (50) 120 (60) 200 (100) 80 (40) 80 (40) 120 (60) 200 (100) * Values in parentheses apply to Sensors operating at different frequencies. *1. The B dimension applies to the top, right-side, and left-side surfaces. *2. The values for A or B for the TL-N apply when there is metal on only one side of the sensor. If there is metal on two or more sides of the sensor, the value must be multiplied by two or more. A Distance TL-Q2MC1 * The mounting plate must be a nonferrous metal. Distance Distance A* 30 (8) B* 90 (45) * Values in parentheses apply to Sensors operating at different frequencies. Influence of Surrounding Metal (Unit: mm) Model TL-Q2MC1 Mutual Interference (Unit: mm) Model TL-Q2MC1 B A 12 B 3 ● Mounting When tightening the mounting screws, do not exceed the torque in the following table. Model TL-Q2MC1 TL-Q5M@@ TL-N@M@@ Torque 0.59 N·m 0.9 to 1.5 N·m 9 TL-N/TL-Q (Unit: mm) Dimensions Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified. Sensors TL-Q2MC1 1 * 6 Detection indicator (red) Sensing surface 3.2-dia. mounting hole 18.5±0.2 8 2.5 8 9 25 28 * 2.9-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.15 mm2, Insulator diameter: 0.9 mm), Standard length: 2 m TL-Q5M@@ 32 max. 28 17 Mounting Hole Dimensions 3.5 *1 17 10.5±0.1 Two, 3.3-dia. holes Two, 3.3 dia. Indicators *2 16 3 10.5±0.1 *1. C Models: 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.2 mm2, Insulator diameter: 1.2 mm), Standard length: 2 m D Models: 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.3 mm), Standard length: 2 m *2. C Models: Detection indicator (red) D Models: Operation indicator (red), Setting indicator (green) TL-N7MD@, TL-N5ME@ 35 Two, 4.3 dia. 18±0.45 25 8 dia. 9 dia. 6 23.8 Rubber bushing Mounting Hole Dimensions 25 Two, 4.5-dia. or M4 holes 18.5 0.5 18±0.2 Indicator *2 38.5 *1 18.5 1.5 *1. D Models: 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m E Models: 6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m *2. D1 Models: Operation indicator (red), Setting indicator (green) D2 Models: Operation indicator (red) E Models: Detection indicator (red) TL-N5MY@ TL-N12MD@, TL-N10ME@, TL-N10MY@ 46.3 48.5 Two, 4.3 dia. 30 25 22±0.45 8 dia. 9 dia. 18±0.45 7.7 6.2 34.1 Mounting Hole Dimensions 18±0.2 21.5 Two, 4.5-dia. or M4 holes 18.5 0.5 50 Indicator *2 Rubber bushing 30 Rubber bushing 25 35.8 8 dia. 9 dia. Operation indicator (red) Mounting Hole Dimensions Two, 4.5-dia. or M4 holes Two, 4.3 dia. 18.5 1.5 * 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m 0.5 * 22±0.2 52.5 18.5 1.5 *1 *1. D/Y Models: 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m E Models: 6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m *2. D1 Models: Operation indicator (red) and Setting indicator (green) D2 Models: Operation indicator (red) E Models: Detection indicator (red) Y Models: Operation indicator (red) 10 TL-N/TL-Q TL-N20MD@, TL-N20ME@, TL-N20MY@ 47 Mounting Hole Dimensions Two, 5.5 dia. Two, 5.5-dia. or M5 holes 10 dia. 12 dia. 30±0.45 40 30±0.2 8 Indicator *2 31.8 Rubber bushing *1 40 30 53 1 25 *1. D/Y Models: 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m E Models: 6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m *2. D1 Models: Operation indicator (red) and Setting indicator (green) D2 Models: Operation indicator (red) E Models: Detection indicator (red) Y Models: Operation indicator (red) Accessories (Order Separately) Mounting Bracket Y92E-C20 Y92E-C10 Y92E-C5 32 20 34 Two, M4 20 3.5 Two, M5 35 Two, M4 19.5 4 6 5.5 18 4.5 4.5 *1 12 30±0.2 *1 22±0.2 25 18±0.2 ±0.2 *1 16±0.2 22±0.2 40 30 9 6.5 2.3 7 9.5 2.3 Applicable Models: TL-N5ME@ *2 Applicable Models: TL-N5MY@ Applicable Models: TL-N7MD@ *2 Material: Mounting Bracket: Zinc-plated iron Mounting phillips Screws: Nickel-plated iron 14.5 Applicable Models: TL-N10ME@ *2 Applicable Models: TL-N10MY@ Applicable Models: TL-N12MD@ *2 Material: Mounting Bracket: Zinc-plated iron Mounting phillips Screws: Nickel-plated iron 3.2 24 Applicable Models: TL-N20ME@ *2 Applicable Models: TL-N20MY @ Applicable Models: TL-N20MD@ *2 Material: Mounting Bracket: Zinc-plated iron Mounting phillips Screws: Nickel-plated iron *1. These are the mounting dimensions of the base of the Mounting Bracket. *2. Provided with the product. Mounting Brackets for Wiring Conduit Use (Sold Separately) Y92E-N10C15 Y92E-N5C15 18 2.3 25 18±0.3 11±0.2 Two, 4.3 dia. 21 3.5 5 23.8 2.3 C15 conduit screw, JIS-B-0204 Applicable Models: TL-N5ME@ Applicable Models: TL-N5MY@ Applicable Models: TL-N7MD@ Material: Zinc-plated iron 2.3 30 22±0.3 13±0.2 Two, 4.3 dia. 3.5 5.5 24.3 2.3 C15 conduit screw, JIS-B-0204 Applicable Models: TL-N10ME@ Applicable Models: TL-N10MY@ Applicable Models: TL-N12MD@ Material: Zinc-plated iron 11 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 2014.9 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2014 All Right Reserved.