- Omron Industrial Automation Vietnam

Proximity Sensor with All-stainless Housing
E2FM
CSM_E2FM_DS_E_4_7
Highly Durable Proximity Sensor for
Tough Environments
• Completely stainless-steel housing
• Aluminum chip immunity
• Embedding installation to metal (steel) fittings
• Chemical resistance certified by Ecolab Europe
• Lineup includes pre-wire models and DC 3-wire NPN output
models with fluororesin coating.
Be sure to read Safety Precautions on
page 9.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Note: Models with a fluororesin coating also use vinyl chloride for the cable material
and require separate protection.
Features
One-piece completely stainless-steel housing with a face thickness of 0.8 mm
The face thickness is approximately 4 times that of
previous models (E2ES) to enable sensing in even more
severe conditions than ever.
Brush Test
0.8 mm
Continuous Impact Test
Chemical and Detergent Proof
The one-piece completely stainlesssteel housing of the sensing section
withstands the following chemicals
better.
After 3 Minutes
E2ES
E2FM
E2EQ
(Spatter-resistant)
The stainless-steel head
means almost no wear
when cleaned with a
metal brush.
The E2ES with a
top wall thickness
of 0.2 mm was
penetrated after
10,000 impacts.
E2FM
The E2FM was
not penetrated
after 250,000
impacts (depth:
0.26 mm).
• Sodium chloride
• Gasoline
• Dilute sodium hydroxide
• Dilute hydrochloric acid
• Mineral oil
• Barium hydroxide
Any many others
Note: Cannot be used for explosion-proof
applications.
More than 20 times the
durability of the E2ES!
1
E2FM
Built-in Chip Immunity
Chip immunity performance has been provided to greatly reduce false
signals caused by spatter accumulation and other causes, almost
eliminating the needs for cleaning, e.g., with metal brushes.
Flush Mounting
E2ES
Not influenced by
surrounding
installation
environment.
Workpiece
Workpiece
Extension
distance
E2FM
Note: When mounted in steel.
Main Performance Comparison to Previous OMRON Products
Face thickness
E2FM
0.4 mm
0.8 mm
0.8 mm
0.8 mm
M8
M12
M18
M30
Sensing distance
E2ES
----0.2 mm
0.2 mm
E2FM
1.5 mm
2.0 mm
5.0 mm
10.0 mm
M8
M12
M18
M30
Response frequency
E2ES
----4.0 mm
8.0 mm
M8
M12
M18
M30
E2FM
200 Hz
100 Hz
100 Hz
50 Hz
E2ES
----12 Hz
8 Hz
Ambient operating temperature
E2FM
−25 to 70°C
E2ES
0 to 50°C
The chemical resistance has been certified by Ecolab Europe
Ecolab GmbH & Co. OHG
P.O. Box 13 04 06
D-40551 Düsseldorf
This certificate is based on:
documented test procedures (test no.: F&E/P3-E Nr. 40-1)
according to material resistance
defined product descriptions
standardized cleaning procedure
certifies that for
OMRON Manufacturing of Germany GmbH
Carl-Benz-Strasse 4
71154 Nufringen
Test procedure
Ecolab-test F&E Nr. 40-1
Dipping test:
• Complete immersion in solutions/liquid
Test period:
• 14 days
material resistance tests
were performed with cleaning substances P3-topax 56, P3-topax 66, P3-topax 91 and
demineralized water as a zero reference factor.
The material resistance of the tested series
Temperature:
• room temperature (constant)
Analysis:
Visual judgement like swelling, brittleness,
discoloring
compared to zero-reference factor
(demineralized water)
Photometric documentation
Product specifications:
P3-topax 56:
Acid foam cleaning substance for food and
beverage industry
P3-topax 66:
Alkaline foam cleaning detergent with active
chlorine for machine cleaning in food and
beverage industry
P3-topax 91:
Neutral disinfection agent based on
quaternary ammonium compounds (QAV) for
the food industry
Inductive Proximity Sensor E2FM
to the P3 products used in the test can be considered to be positive according to the
cleaning procedure mentioned overleaf.
Cleaning plan for food and beverage industry*
Rinsing with water 40 – 50°C
Rinsing with low pressure. Rinsing from top to bottom in the
direction of the drains. Cleaning of the drains.
Düsseldorf, 14th February 2006
Foaming from bottom to top
alkaline:
P3-topax 66 2 – 5 %
acid:
P3-topax 56 2 %
temperature: cold up to 40°C
contact time: 15 min. recommended
Ecolab GmbH & Co. OHG
i.V.
i. V.
Thomas Tyborski
Reimund Laaff
daily
on demand
Rinsing with water 40 – 50°C
Rinsing from top to bottom with low pressure
Spray disinfection P3-topax 91 1-2 %, 30 -60 minutes
*short description
2
E2FM
Ordering Information
Sensors [Refer to Dimensions on page 10.]
DC 2-Wire, Pre-wired Models
Size
Shielded
Sensing distance
M8
1.5 mm
M12
2 mm
M18
5 mm
M30
Output
Operation mode
DC 2-Wire
(polarity)
NO
Model
E2FM-X1R5D1 2M *
E2FM-X2D1 2M *
E2FM-X5D1 2M *
E2FM-X10D1 2M *
10 mm
Note: Models with NC operation are also available. Ask your OMRON representative for details.
* Fluororesin-coated models are also available. The model numbers are E2FM-QX@D1. The cable material, however, is vinyl chloride and requires separate protection.
DC 2-wire Pre-wired Smartclick Connector Models (M12)
Size
Shielded
Sensing distance
M8
1.5 mm
M12
2 mm
M18
Output
Polarity Pin allocations: 1-4
Operation mode
Polarity Pin allocations: 1-4
Polarity Pin allocations: 1-4
M30
E2FM-X2D1-M1TGJ 0.3M
No polarity Pin allocations: 3-4
5 mm
10 mm
Model
E2FM-X1R5D1-M1TGJ 0.3M
E2FM-X2D1-M1TGJ-T 0.3M
NO
E2FM-X5D1-M1TGJ 0.3M
No polarity Pin allocations: 3-4
E2FM-X5D1-M1TGJ-T 0.3M
Polarity Pin allocations: 1-4
E2FM-X10D1-M1TGJ 0.3M
No polarity Pin allocations: 3-4
E2FM-X10D1-M1TGJ-T 0.3M
DC 3-Wire, Pre-wired Models
Size
Shielded
Sensing distance
Model
M8
1.5 mm
Output configuration: NPN NO
E2FM-X1R5C1 2M
M12
2 mm
E2FM-X2C1 2M
M18
5 mm
M30
10 mm
Output configuration: PNP NO
E2FM-X1R5B1 2M
E2FM-X2B1 2M
E2FM-X5C1 2M
E2FM-X5B1 2M
E2FM-X10C1 2M
E2FM-X10B1 2M
Note: Models with NC operation are also available. Ask your OMRON representative for details.
DC 3-Wire, M12 Connector Models
Size
Shielded
Sensing distance
Model
M8
1.5 mm
Output configuration: NPN NO
E2FM-X1R5C1-M1
M12
2 mm
E2FM-X2C1-M1
M18
M30
5 mm
10 mm
Output configuration: PNP NO
E2FM-X1R5B1-M1 *
E2FM-X2B1-M1 *
E2FM-X5C1-M1
E2FM-X5B1-M1 *
E2FM-X10C1-M1
E2FM-X10B1-M1 *
* Fluororesin-coated models are also available. The model numbers are E2FM-QX@B1-M1. The cable material, however, is vinyl chloride and requires separate
protection.
3
E2FM
Accessories (Order Separately)
Sensor I/O Connectors (M12, Sockets on One Cable End)
(Models for Connectors and with Pre-wired Connectors: A Connector is not provided with the Sensor. Be sure to order a Connector separately.)
[Refer to XS2, XS5.]
Appearance
Cable length
Straight
L-shape
Smartclick
Connector Relay
Models (M12)
Sensor I/O Connector model number
2m
XS2F-D421-DC0-F
5m
XS2F-D421-GC0-F
2m
XS2F-D422-DC0-F
5m
XS2F-D422-GC0-F
2m
XS5F-D421-D80-F
5m
XS5F-D421-G80-F
Applicable Proximity Sensor model number
E2FM-X@C1-M1
E2FM-X@B1-M1
E2FM-X@D1-M1TGJ
E2FM-X@D1-M1TGJ-T
Note: Refer to Introduction to Sensor I/O Connectors for details.
Ratings and Specifications
DC 2-Wire (E2FM-X@D@)
Size
M8
M12
M18
M30
Shielded
Model E2FM-X1R5D1-@ E2FM-X2D1-@ E2FM-X5D1-@ E2FM-X10D1-@
Item
M12
M18
M30
E2FM-X2D1M1T1GJ-T
E2FM-X5D1M1T1GJ-T
E2FM-X10D1M1T1GJ-T
Shielded
Sensing distance
1.5 mm±10%
2 mm±10%
5 mm±10%
10 mm±10%
2 mm±10%
5 mm±10%
10 mm±10%
Set distance
0 to 1.05 mm
0 to 1.4 mm
0 to 3.5 mm
0 to 7 mm
0 to 1.4 mm
0 to 3.5 mm
0 to 7 mm
Differential travel
15% max. of sensing distance
Sensing object
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 7.)
Standard sensing object
Iron,
8 × 8 × 1 mm
Response frequency *1 200 Hz
Iron,
Iron,
Iron,
Iron,
Iron,
Iron,
12 × 12 × 1 mm 30 × 30 × 1 mm 54 × 54 × 1 mm 12 × 12 × 1 mm 30 × 30 × 1 mm 54 × 54 × 1 mm
100 Hz
100 Hz
50 Hz
Power supply voltage
(operating voltage range)
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
Leakage current
0.8 mA max.
Output configuration
With polarity
Switching
capacity
3 to 100 mA
Residual
voltage
3 V max.
(Load current: 100 mA max., Cable length: 2 m)
Control
output
100 Hz
100 Hz
50 Hz
No polarity
5 V max.
(Load current: 100 mA max., Cable length: 2 m)
Indicators
Operation indicator (red LED), Setting/Operation indicator (green LED)
Operation mode
(with sensing object
approaching)
NO *2
Protection circuits
Surge suppressor, Load short-circuit protection
Ambient temperature range
Operating/Storage: −25 to 70°C (with no icing or condensation)
Ambient humidity range Operating/Storage: 35% to 95% (with no condensation)
Temperature influence ±20% max. of sensing distance at 23°C in the temperature range of −25 to 70°C.
Voltage influence
±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance
50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength
1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
Vibration resistance
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
Destruction:
500 m/s2
10 times each
in X, Y, and Z
directions
Degree of protection
IEC 60529 IP67
Connection method
Unmarked: Pre-wired Models (Standard cable length: 2 m)
Models ending with -M1GJ-@: Pre-wired Connector Models (Standard cable length: 300 mm)
Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions
4
E2FM
Size
M8
M12
M18
Shielded
Materials
Pre-wired
Models (2 m)
Approx. 105 g
Approx. 190 g
Approx. 215 g
Approx. 295 g
Pre-wired
Connector
Models
Approx. 65 g
Approx. 85 g
Approx. 110 g
Approx. 190 g
Case
Stainless steel (SUS303)
Sensing
surface
Stainless steel (SUS303)
(thickness)
(0.4 mm)
Clamping
nuts
Stainless steel (SUS303)
Cable
PVC (flame retardant)
Toothed
washer
Zinc-plated iron
Accessories
M12
M18
M30
E2FM-X2D1M1T1GJ-T
E2FM-X5D1M1T1GJ-T
E2FM-X10D1M1T1GJ-T
---
---
---
Approx. 110 g
Approx. 190 g
Shielded
Model E2FM-X1R5D1-@ E2FM-X2D1-@ E2FM-X5D1-@ E2FM-X10D1-@
Item
Weight
(packed
state)
M30
(0.8 mm)
Approx. 85 g
(0.8 mm)
Instruction manual
*1. The response frequency of the DC switching section is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the
standard sensing object, and a set distance of half the sensing distance.
*2. NC (normally closed) models are also available. Contact your OMRON representative.
5
E2FM
DC 3-Wire (E2FM-X@C@, E2FM-X@B@)
Size
M8
M12
E2FM-X1R5@
E2FM-X2@
Shielded
Item
M18
M30
E2FM-X5@
E2FM-X10@
Shielded
Model
Sensing distance
1.5 mm±10%
2 mm±10%
5 mm±10%
10 mm±10%
Set distance
0 to 1.05 mm
0 to 1.4 mm
0 to 3.5 mm
0 to 7 mm
Differential travel
15% max. of sensing distance
Sensing object
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 7.)
Standard sensing object Iron, 8 × 8 × 1 mm
Iron, 12 × 12 × 1 mm
Iron, 30 × 30 × 1 mm
Iron, 54 × 54 × 1 mm
Response frequency *1
200 Hz
100 Hz
100 Hz
50 Hz
Power supply voltage
(operating voltage
range)
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
Current consumption
10 mA max.
Output configuration
PNP open collector output
Control
output
Switching ca200 mA max.
pacity
Residual
voltage
2 V max. (Load current: 200 mA, Cable length: 2 m)
Indicators
Operation indicator (yellow LED)
Operation mode
(with sensing object
approaching)
C1 Models: NPN open collector, NO (normally open) *2
B1 Models: PNP open collector, NO (normally open) *2
Protection circuits
Reversed power supply polarity protection, Surge suppressor, Load short-circuit protection, and Reversed output polarity protection (except the E2FM-X1R5B1-M1)
Ambient temperature
range
Operating/Storage: −25 to 70°C (with no icing or condensation)
Ambient humidity range Operating/Storage: 35% to 95% (with no condensation)
Temperature
influence
±20% max. of sensing distance at 23°C in the temperature range of −25 to 70°C.
Voltage influence
±1% max. of sensing distance in the rated voltage ±15% range (using the sensing distance at the rated voltage as
standard)
Insulation resistance
50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength
1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
Vibration resistance
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
Destruction: 500 m/s2
10 times each in X, Y, and Z Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions
directions
Degree of protection
IEC 60529 IP67
Connection method
Unmarked: Pre-wired Models (Standard cable length: 2 m)
Models ending with -M1: Connector Models
Weight
(packed
state)
Materials
Pre-wired
Models (2 m)
---
Approx. 170 g
Approx. 190 g
Approx. 275 g
Pre-wired
Connector
Models
Approx. 45 g
Approx. 55 g
Approx. 75 g
Approx. 160 g
Case
Stainless steel (SUS303)
Sensing surface
Stainless steel (SUS303)
(thickness)
(0.4 mm)
Clamping
nuts
Stainless steel (SUS303)
Toothed
washer
Zinc-plated iron
Accessories
(0.8 mm)
Instruction manual
*1. The response frequency of the DC switching section is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the
standard sensing object, and a set distance of half the sensing distance.
*2. NC (normally closed) models are also available. Contact your OMRON representative.
6
E2FM
Engineering Data (Reference Value)
Influence of Sensing Object Size and Material
E2FM-X@
E2FM-X1R5@
E2FM-X10@
10
8
E2FM-X2@
2.5
Distance X (mm)
12
Distance X (mm)
Distance X (mm)
Sensing Area
2.0
Iron
3.0
2.5
Iron
2.0
1.5
E2FM-X5@
6
1.5
1.0
4
Stainless
steel
(SUS304)
Brass
E2FM-X2D@
E2FM-X1R5@
0.5
2
Stainless
steel
(SUS304) Aluminum
1.0
Brass
0.5
Aluminum
Copper
0
−25 −20 −15 −10
−5
0
5
10 15 20 25
Distance Y (mm)
Copper
0.0
0.0
0
5
10
15
20
25
Side length of sensing object: d (mm)
0
5
10
15
20
25
30
35
Side length of sensing object: d (mm)
Leakage Current
E2FM-X@D1-M1TGJ (-T)
12
7
6
Iron
10
Iron
5
8
Stainless
steel
(SUS304)
4
6
3
Stainless
steel
(SUS304)
2
Leakage current (mA)
E2FM-X10@
Distance X (mm)
Distance X (mm)
E2FM-X5@
1.0
E2FM-X1R5D1-@
0.8
E2FM-X10D1-M1TGJ(-T)
0.6
E2FM-X5D1-M1GJ(-T)
0.4
4
E2FM-X2D1-M1TGJ(-T)
Brass
Brass
0.2
2
1
Aluminum
Aluminum
Copper
0
0
20
Copper
0
0
40
60
80
Side length of sensing object: d (mm)
10
20
30
40
50
60
70
80 90
Side length of sensing object: d (mm)
0.0
0
5
10
15
20
25
30
Power supply voltage (V)
Residual Output Voltage
E2FM-X@D1-M1TGJ (-T)
Residual output voltage (V)
Residual output voltage (V)
E2FM-X@C@/B@
2
1.5
E2FM-X2@
E2FM-X5@
1
E2FM-X10@
5
4
E2FM-X@D1-M1TGJ-T
3
E2FM-X@D1-@
2
0.5
1
E2FM-X1R5@
0
0
1
10
50
100 200
1,000
Load current (mA)
1
3
5
10
30
50
100
Load current (mA)
7
E2FM
I/O Circuit Diagrams
DC 2-Wire Models
Operation
mode
Model
Timing chart
Output circuit
Brown
1
E2FMX@D1-@
Non-sensing area
Stable sensing
area
Blue
4
Proximity sensor
Sensing object
(%)
NO
12 to 24 VDC
Proximity
sensor
main
circuit
Set position
Unstable
sensing
area
Connector Pin
Arrangement
Load
Note: Pins 2 and 3
are not used.
0V
Note: The load can be connected to either the +V or 0 V side.
100
Rated
sensing
distance
70 (TYP)
0
4
OFF
Proximity
sensor
main
circuit
Operation
indicator
(red)
ON
E2FMX@D1M1TGJ-T
OFF
ON
3
Note: Pins 1 and 2 are
not used.
0V
Control
output
OFF
Connector Pin
Arrangement
Load
12 to 24VDC
Setting
indicator
(green)
ON
Note1. The load can be connected to either the +V or 0 V side.
2. The E2FM-X@@1-M1TGJ-T has no polarity. There is no need to be concerned
about the polarity of pins 3 and 4.
DC 3-Wire Models
Operation
mode
Output
configuration
Model
E2FMX1R5C@
NPN
E2FMopen- X2C@
collector E2FMmodel X5C@
E2FMX10C@
Timing chart
Output circuit
Brown
+V
Load
Sensing area
Non-sensing area
Proximity sensor
Connector Pin
Arrangement
*
Black
Sensing object
Blue
Note: For Connector Models, the
connection between pins 1, 4 and 3
uses an NO contact, and the
connection between pins 1, 2 and 3
* There is no reversed output polarity protection diode.
uses an NC contact.
0V
(%)
100
0
NO
E2FMX1R5B@
PNP
E2FMopen- X2B@
collector E2FMmodel X5B@
E2FMX10B@
Proximity
sensor
main
circuit
Rated
sensing
distance
Brown
DC12 to 24VDC
Operation
indicator
OFF (yellow)
ON
ON
OFF
Proximity
sensor
main
circuit
*
Connector Pin
Arrangement
Black
Control
output
Load
Note: For Connector Models, the
connection between pins 1, 4 and 3
uses an NO contact, and the
connection between pins 1, 2 and 3
* There is no reversed output polarity protection diode.
uses an NC contact.
Blue
0V
8
E2FM
Safety Precautions
(Unit: mm)
WARNING
Item
This product is not designed or rated for ensuring
safety of persons. Do not use it for such purposes.
Model
E2FM-X1R5@
Never use this product with an AC power supply.
Otherwise, explosion may result.
E2FM-X2@
Precautions for Safe Use
E2FM-X5@
The following precautions must be observed to ensure safe operation.
1. Do not use the Sensor in an environment where inflammable or
explosive gas is present.
2. Do not attempt to disassemble, repair, or modify any Sensors.
3. Power Supply Voltage
Do not use a voltage that exceeds the rated operating voltage
range. Applying a voltage that is higher than the operating voltage
range may result in explosion or fire.
4. Incorrect Wiring
Be sure that the power supply polarity and other wiring is correct.
Incorrect wiring may cause explosion or fire.
5. Connection without a Load
If the power supply is connected directly without a load, the internal
elements may explode or burn. Be sure to insert a load when
connecting the power supply.
E2FM-X10@
Embedding
material
l
d
D
m
n
Iron
0
8
0
4.5
30
Aluminum
10
50
10
4.5
50
Iron
0
12
0
8
40
Aluminum
16
70
16
8
70
Iron
0
18
0
20
60
Aluminum
16
80
16
20
80
Iron
0
30
0
40
100
Aluminum
24
120
24
40
120
Note: The influence from other non-magnetic surrounding metals is nearly the
same as that from aluminum.
Mutual Interference
When installing two or more Sensors face-to-face or side-by-side,
ensure that the minimum distances given in the following table are
maintained.
(Unit: mm)
Model
A
B
E2FM-X1R5@
Item
35
30
E2FM-X2@
40
35
Precautions for Correct Use
E2FM-X5@
65
60
Do not use the Sensor under ambient conditions that exceed the
ratings.
1. Do not use the Sensor in the following locations.
(1) Outdoor locations directly subject to sunlight, rain, snow, or
water droplets
(2) Locations subject to atmospheres with chemical vapors, in
particular solvents and acids
(3) Locations subject to corrosive gas
2. The Sensor may malfunction if used near ultrasonic cleaning
equipment, high-frequency equipment, transceivers, cellular
phones, inverters, or other devices that generate a high-frequency
electric field. Refer to the Technical Guide Photoelectric Sensors
for typical measures.
3. Laying the Sensor wiring in the same conduit or duct as highvoltage wires or power lines may result in incorrect operation and
damage due to induction. Wire the Sensor using a separate
conduit or independent conduit.
4. Cleaning
Never use thinner or other solvents. Otherwise, the Sensor surface
may be dissolved.
E2FM-X10@
110
100
A
B
Chips from Cutting Aluminum
Normally, chips from cutting aluminum or cast iron will not cause a
detection signal to be output even if it adheres to or accumulates on
the detection surface. In the following cases, however, a detection
signal may be output. Remove the cutting chips in these cases.
2
1. If d ≥ 3 D at the center of the detection
surface where d is the cutting chip size
and D is the detection surface size
Model
Dimension
(mm)
E2FM-X1R5@
E2FM-X2@
E2FM-X5@
E2FM-X10@
Cutting chip
D
Detection surface
D
6
10
16
28
2. If the cutting chips are pressed down
● Design
Influence of Surrounding Metal
d
Pressed down
Cutting chips
When the Proximity Sensor is embedded in metal, make sure that the
clearances given in the following table are maintained. The values
depend on the type of nuts used for mounting. Be sure to use the
supplied nuts (SUS303).
● Mounting
d dia.
n
m
D
l
l
Do not tighten the nut with excessive force. A washer must be used
with the nut. Do not use tightening force that exceeds the values in the
following table.
Model
E2FM-X1R5@
E2FM-X2@
E2FM-X5@
E2FM-X10@
Torque
9 N·m
30 N·m
70 N·m
180 N·m
9
E2FM
(Unit: mm)
Dimensions
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
Sensors
Pre-wired Models
E2FM-X1R5@
E2FM-X2@
53
49
39
30
25
15 dia.
4
5
Two clamping
nuts
M8 × 1
13
4-dia. vinyl-insulated round cable (flame
retardant), Standard length; 2 m *
Operation indicators
33
6-dia. vinyl-insulated round cable (flame
retardant), Standard length; 2 m *
Two clamping
Operation indicators
nuts
M12 × 1
17
Toothed washer
7
4
21 dia.
Toothed washer
* 4-dia. vinyl-insulated round cable with 2 conductors
(Conductor cross section: 0.2 mm2, Insulator diameter: 1.4 mm)
4-dia. vinyl-insulated round cable with 3 conductors
(Conductor cross section: 0.2 mm2, Insulator diameter: 1.2 mm)
* 6-dia. vinyl-insulated round cable with 2 conductors
(Conductor cross section: 0.5 mm2, Insulator diameter: 1.75 mm)
6-dia. vinyl-insulated round cable with 3 conductors
(Conductor cross section: 0.5 mm2, Insulator diameter: 1.75 mm)
E2FM-X10@
E2FM-X5@
63.5
49
43
42 dia.
56
10
5
42
36
10
4
29 dia.
6-dia. vinyl-insulated round cable (flame
retardant), Standard length; 2 m *
6-dia. vinyl-insulated round cable (flame
retardant), Standard length; 2 m *
24
Two clamping
Operation indicators
nuts
M18 × 1
36
Operation indicators
M30 × 1.5
Two clamping
nuts
Toothed washer
Toothed washer
* 6-dia. vinyl-insulated round cable with 2 conductors
(Conductor cross section: 0.5 mm2, Insulator diameter: 1.75 mm)
6-dia. vinyl-insulated round cable with 3 conductors
(Conductor cross section: 0.5 mm2, Insulator diameter: 1.75 mm)
* 6-dia. vinyl-insulated round cable with 2 conductors
(Conductor cross section: 0.5 mm2, Insulator diameter: 1.75 mm)
6-dia. vinyl-insulated round cable with 3 conductors
(Conductor cross section: 0.5 mm2, Insulator diameter: 1.75 mm)
Pre-wired Connector Models
E2FM-X1R5D@-M1TGJ-@
E2FM-X2D@-M1TGJ-@
53
49
30
25
15 dia.
13
4
M12 × 1
21 dia.
5
Two clamping
nuts
Indicator *2
M8 × 1
39
33
*1
17
Toothed washer
4
M12 × 1
7
Two
clamping nuts
Indicator *2
M12 × 1
Toothed washer
*1. 4-dia. vinyl-insulated round cable (flame retardant), Standard length; 300 mm
*2. Operation indicator (red/green)
Setting indicator (green)
E2FM-X5D@-M1TGJ-@
*1
*1. 6-dia. vinyl-insulated round cable (flame retardant), Standard length; 300 mm
*2. Operation indicator (red/green)
Setting indicator (green)
E2FM-X10D@-M1TGJ-@
63.5
49
43
56
42
36
29 dia.
24
4
M18 × 1
42 dia.
10
5
10
M12 × 1
M12 × 1
Two clamping
nuts
Toothed washer
Indicator *2
*1
*1. 6-dia. vinyl-insulated round cable (flame retardant), Standard length; 300 mm
*2. Operation indicator (red/green)
Setting indicator (green)
36
M30 × 1.5
Two clamping
nuts
Toothed washer
*1
Indicator *2
*1. 6-dia. vinyl-insulated round cable (flame retardant), Standard length; 300 mm
*2. Operation indicator (red/green)
Setting indicator (green)
10
E2FM
M12 Connector Models
E2FM-X1R5@@-M1
E2FM-X2@@-M1
53
53.5
39
34.5
33
30
25
4
15 dia.
13
21 dia.
7
4
5
M8 × 1
Toothed washer
Two
clamping
M12 × 1
nuts
Four operation indicators (yellow)
17
Two clamping
nuts
M12 × 1
E2FM-X5@@-M1
M12 × 1
Four operation indicators (yellow)
Toothed washer
E2FM-X10@@-M1
63.5
49
43
56
42
36
29 dia.
4
42 dia.
10
5
10
M12 × 1
24
M18 × 1
Two clamping
nuts
Toothed washer
M12 × 1
Four operation indicators (yellow)
36
M30 × 1.5
Two clamping
nuts
Four operation indicators (yellow)
Toothed washer
Mounting Hole Dimensions
Dimension
F (mm)
M8
8.5 +0.5
dia.
0
M12
12.5 +0.5
dia.
0
M18
18.5 +0.5
dia.
0
M30
30.5 +0.5
dia.
0
F
11
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2014.10
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/