Lighted Pushbutton Switch (Square) A3S CSM_A3S_DS_E_6_2 Pushbutton Switch Series with Square 40-mm Body • Combines miniature design with distinct but soft sense of operation. • Easy panel mounting from the front and simple lamp replacement without tools. Refer to Safety Precautions for All Pushbutton Switches/ Indicators and Safety Precautions on page 18. List of Models Lighted Pushbutton Switches Appearance Model Rectangular A3SJ Square A3SA ■ Specifications: Refer to page 12. ■ Dimensions: Refer to page 14. ■ Accessories: Refer to pages 10 to 11. 1 A3S Model Number Structure Model Number Legend ..... The model numbers used to order sets are illustrated below. One set comprises the Operation Unit, Lamp, and Socket Unit. For information on combinations, refer to Ordering Information on pages 3 to 4. 1 - 24E R (1) (2) ............ Single screen Left Right A 3 S J - 9 0 A 3 - 24E RW ............ Vertical 2-split screen Left R (Red) (1) Shape of Operation Unit Symbol J A Shape Rectangular Square (2) Switch Specifications Standard Load Symbol Operation Momentary A SPDT B Alternate C Momentary DPDT D Alternate (3) Screen Pattern Illumination-only models Symbol Right W (White) (4) Lighting Method LED-lighted Models Screen pattern Rated voltage 5 VDC 12 VDC 24 VDC Symbol Single screen 05E 12E 24E 1 (5) Operation Unit Color For LED Symbol R Y G W Color Red Yellow Green White * Vertical 2-split screen Incandescent Lamp-lighted Models Microload Symbol Operation E Momentary SPDT F Alternate G Momentary DPDT H Alternate • Standard Load 250 VAC, 2 A 125 VDC, 0.4 A 3 • Models with colored illumination can be ordered individually. Refer to page 5 for details. Colored Illumination Unlit Lit White Color Rated voltage 6 VAC/VDC 14 VAC/VDC 28 VAC/VDC Symbol (rectangular models only) 06 14 28 Incandescent Lamp-lighted Models Symbol R Y G A W Color Red Yellow Green Blue White * * The color cap is transparent. • Microload 125 VAC, 0.1 A 30 VDC, 0.1 A Minimum applicable load 5 VDC, 1 mA Momentary operation ...Self-resetting Alternate operation ...Self-holding The built-in LED is colored. Number of Built-in LEDs and Incandescent Lamps Model A3SJ A3SA Type Screen pattern Single screen Vertical 2-split screen Single screen LED 2 Incandescent lamp 1 2 2 1 1 Structure of Split-screen Operation Unit Color cap Legend plate * Dispersion plate Light-separation plate (2-split screen only) Single screen (Rectangular models and square models) Vertical 2-split screen (Rectangular models only) LED/incandescent lamp holder A3SJ * Not included for the Square Models (A3SA) with incandescent lamp. 2 A3S Ordering Information Ordering as a Set .................The model numbers used to order sets of Units are given in the following tables. One set comprises the Operation Unit, Lamp, and Socket Unit. Standard Loads Single screen Rectangular Models A3SJ 1 Vertical 2-split screen 1 2 Single screen Contact type Operation Output Lighting LED SPDT Incandescent lamp LED DPDT Incandescent lamp 5 VDC 12 VDC 24 VDC 6 VAC/VDC 14 VAC/VDC 28 VAC/VDC 5 VDC 12 VDC 24 VDC 6 VAC/VDC 14 VAC/VDC 28 VAC/VDC Standard load (250 VAC, 2 A; 125 VDC 0.4 A) Momentary operation Alternate operation (Self-resetting) (Self-holding) A3SJ-90A1-05E@ A3SJ-90B1-05E@ A3SJ-90A1-12E@ A3SJ-90B1-12E@ A3SJ-90A1-24E@ A3SJ-90B1-24E@ A3SJ-90A1-06@ A3SJ-90B1-06@ A3SJ-90A1-14@ A3SJ-90B1-14@ A3SJ-90A1-28@ A3SJ-90B1-28@ A3SJ-90C1-05E@ A3SJ-90D1-05E@ A3SJ-90C1-12E@ A3SJ-90D1-12E@ A3SJ-90C1-24E@ A3SJ-90D1-24E@ A3SJ-90C1-06@ A3SJ-90D1-06@ A3SJ-90C1-14@ A3SJ-90D1-14@ A3SJ-90C1-28@ A3SJ-90D1-28@ Operation Unit color symbol Enter the desired color symbol for the Pushbutton in @. R (Red) Y (Yellow) G (Green) A (Blue) * W (White) * Incandescent lamp only. Vertical 2-split screen Contact type Operation Output SPDT DPDT Lighting Standard load (250 VAC, 2 A; 125 VDC 0.4 A) Momentary operation Alternate operation (Self-resetting) (Self-holding) LED 24 VDC A3SJ-90A3-24E@@ A3SJ-90B3-24E@@ Incandescent lamp 28 VDC A3SJ-90A3-28@@ A3SJ-90B3-28@@ LED 24 VDC A3SJ-90C3-24E@@ A3SJ-90D3-24E@@ Incandescent lamp 28 VDC A3SJ-90C3-28@@ A3SJ-90D3-28@@ Operation Unit color symbol Enter the desired color symbol for the Pushbutton in @@. R (Red) Y (Yellow) G (Green) W (White) A (Blue) * * Incandescent lamp only. Microloads Single screen Vertical 2-split screen Contact type Operation Output Lighting 5 VDC LED 12 VDC 24 VDC SPDT 6 VAC/VDC Incandescent 14 VAC/VDC lamp 28 VAC/VDC 5 VDC LED 12 VDC 24 VDC DPDT 6 VAC/VDC Incandescent 14 VAC/VDC lamp 28 VAC/VDC Microload (125 VAC, 0.1 A; 30 VDC 0.1 A) Momentary operation (Self-resetting) A3SJ-90E1-05E@ A3SJ-90E1-12E@ A3SJ-90E1-24E@ A3SJ-90E1-06@ A3SJ-90E1-14@ A3SJ-90E1-28@ A3SJ-90G1-05E@ A3SJ-90G1-12E@ A3SJ-90G1-24E@ A3SJ-90G1-06@ A3SJ-90G1-14@ A3SJ-90G1-28 @ Operation Unit color symbol Enter the desired color symbol for the Pushbutton in @. R (Red) Y (Yellow) G (Green) A (Blue) * W (White) Contact type Microload (125 VAC, 0.1 A; 30 VDC 0.1 A) Operation Momentary operation (Self-resetting) Lighting Output LED SPDT DPDT 24 VDC A3SJ-90E3-24E@@ Incandescent 28 VDC lamp A3SJ-90E3-28@@ LED A3SJ-90G3-24E@@ 24 VDC Incandescent 28 VDC lamp A3SJ-90G3-28@@ Operation Unit color symbol Enter the desired color symbol for the Pushbutton in @@. R (Red) Y (Yellow) G (Green) W (White) A (Blue) * * Incandescent lamp only. Individual models: Refer to pages 6 to 9. ■ Specifications: Refer to page 12. ■ Dimensions: Refer to page 14. (The Pushbutton, Lamp, and Switch can be ordered separately.) ■ Accessories: Refer to pages 10 to 11. 3 A3S Ordering Information Ordering as a Set ................. The model numbers used to order sets of Units are given in the following tables. One set comprises the Operation Unit, Lamp, and Socket Unit. Standard Loads Square Models A3SA Single screen Single screen Contact type Operation Output Lighting LED SPDT Incandescent lamp LED DPDT Incandescent lamp 5 VDC 12 VDC 24 VDC 6 VAC/VDC 14 VAC/VDC 28 VAC/VDC 5 VDC 12 VDC 24 VDC 6 VAC/VDC 14 VAC/VDC 28 VAC/VDC Standard load (250 VAC, 2 A; 125 VDC 0.4 A) Momentary operation (Self-resetting) Alternate operation (Self-holding) A3SA-90A1-05E@ A3SA-90A1-12E@ A3SA-90A1-24E@ A3SA-90A1-06@ A3SA-90A1-14@ A3SA-90A1-28@ A3SA-90C1-05E@ A3SA-90C1-12E@ A3SA-90C1-24E@ A3SA-90C1-06@ A3SA-90C1-14@ A3SA-90C1-28@ A3SA-90B1-05E@ A3SA-90B1-12E@ A3SA-90B1-24E@ A3SA-90B1-06@ A3SA-90B1-14@ A3SA-90B1-28@ A3SA-90D1-05E@ A3SA-90D1-12E@ A3SA-90D1-24E@ A3SA-90D1-06@ A3SA-90D1-14@ A3SA-90D1-28@ Operation Unit color symbol Enter the desired color symbol for the Pushbutton in @. R (Red) Y (Yellow) G (Green) A (Blue) * W (White) * Incandescent lamp only. Microloads Single screen Contact type Operation Output Lighting LED SPDT Incandescent lamp LED DPDT Incandescent lamp 5 VDC 12 VDC 24 VDC 6 VAC/VDC 14 VAC/VDC 28 VAC/VDC 5 VDC 12 VDC 24 VDC 6 VAC/VDC 14 VAC/VDC 28 VAC/VDC Microload (125 VAC, 0.1 A; 30 VDC 0.1 A) Operation Unit color symbol Momentary operation (Self-resetting) A3SA-90E1-05E@ A3SA-90E1-12E@ A3SA-90E1-24E@ Enter the desired color A3SA-90E1-06@ symbol for the Pushbutton A3SA-90E1-14@ in @. A3SA-90E1-28@ R (Red) Y (Yellow) A3SA-90G1-05E@ G (Green) A3SA-90G1-12E@ A (Blue) * A3SA-90G1-24E@ W (White) A3SA-90G1-06@ A3SA-90G1-14@ A3SA-90G1-28@ * Incandescent lamp only. Individual models: Refer to pages 6 to 9. ■ Specifications: Refer to page 12. ■ Dimensions: Refer to page 14. (The Pushbutton, Lamp, and Switch can be ordered separately.) ■ Accessories: Refer to pages 10 to 11. 4 A3S Ordering Information Illumination-only and Colored-illumination LED Models Illumination only describes LED models for which the screen color is the same whether the LED is lit or not. The screen simply becomes brighter when the LED lights. Example: Red LED Color cap (red) Not lit Red Legend plate (transparent) Display Lit Dispersion plate (milk-white) Red LED lamp holder LED (red) Colored illumination describes LED models for which the screen color is white when the LED is not lit and changes to the color of the LED lamp when the LED is lit. Example: Red LED Color cap (transparent) Not lit White Legend plate (transparent) Pushbutton Lit Dispersion plate (milk-white) Red LED lamp holder LED (red) Ordering .......................................With colored-illumination models, order the Display (Operation Unit), Lamp, and Socket Unit as shown in the following table. Display (Operation Unit) Single screen LED Rectangular models A3SJ-5801 Square models A3SA-5801 Rectangular models only A3SJ-5921 2-split screen Select the LED lamps to suit your desired coloration from the selection on page 9. Socket Unit Select from the Switches on page 9. 5 A3S Ordering Information Ordering Individually ......... Operation Units, Lamps, and Socket Units can be ordered separately. Combinations that are not available as sets can be created using individual Units. Also, store the parts as spares for maintenance and repairs. Ordering ....................................... Specify a model number from the following page. LED-lighted Models Incandescent Lamp-lighted Models Operation Unit Operation Unit Lamp (LED) Lamp (Incandescent Lamp) · DC-only SLL-@@E@ Socket Unit Ordering set combinations: Refer to pages 3 to 4. · Standard lamp SLL-@@ Socket Unit ■ Specifications: Refer to page 12. ■ Dimensions: Refer to page 14. ■ Accessories: Refer to pages 10 to 11. 6 A3S Ordering Information Ordering Individually .........Operation Units, Lamps, and Socket Units can be ordered separately. Combinations that are not available as sets can be created using individual Units. Also, store the parts as spares for maintenance and repairs. Operation Unit LED-lighted Models (LED is not built in.) Appearance Rectangular Models (2 LEDs) Screen pattern Single screen Standard split screen 2-split screen * Reverse split screen One-color 2-split screen Display color White Red Green Yellow White/red White/green White/yellow Red/green Red/yellow Green/yellow Red/white Green/white Yellow/white Green/red Yellow/red Yellow/green White/white Red/red Green/green Yellow/yellow (transparent legend plate built in) A3SJ-5801 A3SJ-5802 A3SJ-5803 A3SJ-5805 A3SJ-5901 A3SJ-5902 A3SJ-5904 A3SJ-5905 A3SJ-5907 A3SJ-5909 A3SJ-5911 A3SJ-5912 A3SJ-5914 A3SJ-5915 A3SJ-5917 A3SJ-5919 A3SJ-5921 A3SJ-5922 A3SJ-5923 A3SJ-5925 Square Models (1 LED) (transparent legend plate built in) A3SA-5801 A3SA-5802 A3SA-5803 A3SA-5805 − − − Note: The color cap is transparent when the display color is white. * Two-split screen configurations are given with the OMRON surface of the case downward. Ordering set combinations: Refer to pages 3 to 4. ■ Specifications: Refer to page 12. ■ Dimensions: Refer to page 14. ■ Accessories: Refer to pages 10 to 11. 7 A3S Ordering Information Ordering Individually ......... Operation Units, Lamps, and Socket Units can be ordered separately. Combinations that are not available as sets can be created using individual Units. Also, store the parts as spares for maintenance and repairs. Operation Unit Incandescent Lamp-lighted Models (Incandescent lamp is not built in.) Appearance Rectangular Screen pattern One lamp Single screen Standard split screen 2-split screen * Reverse split screen One-color 2-split screen Two lamps Square Display color White Red Green Blue Yellow (transparent legend plate built in) A3SJ-5301 A3SJ-5302 A3SJ-5303 A3SJ-5304 A3SJ-5305 (Legend plate not included) A3SA-5301 A3SA-5302 A3SA-5303 A3SA-5304 A3SA-5305 White Red Green Blue Yellow A3SJ-5321 A3SJ-5322 A3SJ-5323 A3SJ-5324 A3SJ-5325 − White/red White/green White/blue White/yellow Red/green Red/blue Red/yellow Green/blue Green/yellow Blue/yellow Red/white Green/white Blue/white Yellow/white Green/red Blue/red Yellow/red Blue/green Yellow/green Yellow/blue White/white Red/red Green/green Blue/blue Yellow/yellow A3SJ-5201 A3SJ-5202 A3SJ-5203 A3SJ-5204 A3SJ-5205 A3SJ-5206 A3SJ-5207 A3SJ-5208 A3SJ-5209 A3SJ-5210 A3SJ-5211 A3SJ-5212 A3SJ-5213 A3SJ-5214 A3SJ-5215 A3SJ-5216 A3SJ-5217 A3SJ-5218 A3SJ-5219 A3SJ-5220 A3SJ-5221 A3SJ-5222 A3SJ-5223 A3SJ-5224 A3SJ-5225 − − − Note: The color cap is transparent when the display color is white. * Two-split screen configurations are given with the OMRON surface of the case downward. Ordering set combinations: Refer to pages 3 to 4. ■ Specifications: Refer to page 12. ■ Dimensions: Refer to page 14. ■ Accessories: Refer to pages 10 to 11. 8 A3S Ordering Information Ordering Individually .........Operation Units, Lamps, and Socket Units can be ordered separately. Combinations that are not available as sets can be created using individual Units. Also, store the parts as spares for maintenance and repairs. Lamp LED Lamp Operating voltage Color Red Yellow Green White 5 VDC 12 VDC 24 VDC Model (DC only) SLL-05ER SLL-05EY SLL-05EG SLL-05EW Model (DC only) SLL-12ER SLL-12EY SLL-12EG SLL-12EW Model (DC only) SLL-24ER SLL-24EY SLL-24EG SLL-24EW Note: The A3SJ (M2SJ) requires two LEDs for each Switch. The A3SA (M2SA) requires one LED. Incandescent Lamp Lamp type Operating voltage 5 VAC/VDC 12 VAC/VDC 24 VAC/VDC Standard lamp Low-voltage lamp SLL-06 SLL-14 SLL-28 SLL-06H SLL-14H SLL-28H Note: The low-voltage lamp has an advantage in that it generates less heat. Switch (common to both LED models and incandescent lamp-lighted models) Contact type Standard load Microload Number of outputs Appearance Rectangular models Square models Selection precautions Operation Momentary operation A3SJ-8010 A3SA-7010 Alternate operation A3SJ-8020 A3SA-7020 Momentary operation A3SJ-8030 A3SA-7030 Alternate operation A3SJ-8040 A3SA-7040 1 Silver contacts 2 Gold alloy contacts Momentary operation A3SJ-8050 A3SA-7050 Alternate operation A3SJ-8060 A3SA-7060 Momentary operation A3SJ-8070 A3SA-7070 Alternate operation A3SJ-8080 A3SA-7080 1 2 • Use the Socket Unit in combination with the same shape Operation Unit (rectangular or square). Example: For the A3SJ-5801 Rectangular Operation Unit, select the A3SJ-8@@0 Socket Unit. • Momentary operation is self-resetting, and alternate operation is self-holding (i.e., push-on, push-off). 9 A3S Ordering Information Accessories, Replacements, and Tools Accessories for Rectangular Models Name Appearance Classification Model Short edge Barriers (1 pair) A3SA-4001 Short intermediate Barriers A3SA-4002 Long edge Barriers (1 pair) A3SJ-4003 Long intermediate Barriers A3SJ-4004 Barrier Application precautions The purpose of a Barrier is to prevent malfunctioning and to improve design image of the mounting panel. There is one intermediate Barrier and one pair of edge Barriers (2 Barriers). Mount Short Barriers horizontally. Mount Long Barriers vertically. Switch Guard − A3SJ-5050 Cannot be used with Barrier or Seal Cover. Seal Cover − A3SJ-5060 • Cannot be used with Barrier or Switch Guard. • Cap material: Vinyl chloride A3SJ-3002 Use when vertically mounting individual (with Barrier) or multiple Switches (in standard mounting style and with Barrier). A Short Mounting Plate is attached to the Switch; replace it with the long one. Model Application precautions Short Edge Barriers (1 pair) A3SA-4001 Short Intermediate Barrier A3SA-4002 The purpose of the Barrier is to prevent malfunctioning and to improve design image of the mounting panel. Long Mounting Plate 1 pair Accessories for Square Models Name Appearance Classification Barrier Switch Guard − A3SA-5050 Cannot be used with Barrier or Seal Cover. Seal Cover − A3SA-5060 • Cannot be used with Barrier or Switch Guard. • Cap material: Vinyl chloride ■ Accessory mounting: Refer to page 19. 10 A3S Ordering Information Accessories, Replacements, and Tools Replacements for Rectangular Models Name Appearance Classification Model Application precautions Wire-wrap terminals A3SJ-4104 PCB terminals A3SJ-4105 Solder terminals A3SJ-4106 Dispersion plate Milk-white A3SJ-5107 − Color cap Transparent White Red Green Blue Yellow Transparent White Red Green Blue Yellow A3SJ-5600 A3SJ-5601 A3SJ-5602 A3SJ-5603 A3SJ-5604 A3SJ-5605 A3SJ-5630 A3SJ-5631 A3SJ-5632 A3SJ-5633 A3SJ-5634 A3SJ-5635 • Contact your OMRON representative for color changes or inscribing. • If LEDs are to be used, use a color cap that matches the LED color. • The blue color cap is only for incandescent lamps. Socket Single screen Single screen 2-split screen Transparent A3SJ-4204 Milk-white A3SJ-4203 Legend plate • Sockets cannot be used for multiple mounting. A transparent legend plate is mounted on the Operation Unit. Replacements for Square Models Name Appearance Classification Model Application precautions Wire-wrap terminals A3SA-4101 PCB terminals A3SA-4102 Solder terminals A3SA-4103 Dispersion plate Milk-white A3SA-5107 − Color cap Transparent White Red Green Blue Yellow A3SA-5600 A3SA-5601 A3SA-5602 A3SA-5603 A3SA-5604 A3SA-5605 • Contact your OMRON representative for color changes or inscribing. • If LED colors are to be used, use a color cap that matches the LED color. Transparent A3SA-4204 Milk-white A3SA-4203 Socket Legend plate • Sockets cannot be used for multiple mounting. A transparent color cap is mounted to a standard Display. Legend plates cannot be used, however, with Displays for incandescent lamps. Tools Name Appearance Extractor Classification Model − A3PJ-5080 Application precautions Convenient for extracting the Operation Unit. ■ Accessory mounting: Refer to page 19. 11 A3S Specifications Approved Standard Ratings Characteristics UL (File No. E41515), CSA (File No. LR45258) Standard Load: 3 A at 125 VAC 2 A at 250 VAC 0.1 A at 125 VAC 0.1 A at 30 VDC Microload: Note: Certification has been obtained for the Switch Unit. For detailed information on individual products that have received certification, consult your supplier. Ratings For Standard Loads Non-inductive load (A) Resistive Lamp load load NC NO NC NO 3 1 0.7 2 0.7 0.5 3 1 3 1 2 1 0.4 0.05 0.2 0.03 Rated voltage 125 VAC 250 VAC 8 VDC 14 VDC 30 VDC 125 VDC 250 VDC Inductive load (A) Inductive Motor load load NC NO NC NO 2 1.5 1 1.5 1 0.7 2 1.5 1.5 1.5 1.5 1 0.4 0.05 0.2 0.03 Note: 1. The above values are for steady-state currents. 2. Inductive load: Power factor = 0.4; time constant = 7 ms. 3. The lamp load has an inrush current of 10 times the steady-state current. 4. The motor load has an inrush current of 6 times the steady-state current. The rated values are for testing conducted under the following conditions. (1) Ambient temperature: 20±2°C (2) Ambient humidity: 65% ±5%RH (3) Operating frequency: 20 times/min For Microloads Rating 0.1 A at 30 VDC (resistive load); 0.1 A at 125 VAC (resistive load) Minimum applicable load 1 mA at 5 VDC LED Lamp Type Applied voltage Rated voltage Rated current DC only 5 VDC±5% 12 VDC±5% 24 VDC±5% 5 VDC 12 VDC 24 VDC 30 mA 15 mA 12.5 mA Built-in limiting resistance 39 Ω 270 Ω 1300 Ω Incandescent Lamp Applied voltage Rated voltage 5 VAC/VDC 12 VAC/VDC 24 VAC/VDC 6 VAC/VDC 14 VAC/VDC 28 VAC/VDC Operating Mechanical frequency Electrical Insulation resistance Standard load Contact resistance Microload Between terminals of same polarity Between terminals of different polarity Between currentDielectric carrying metal part strength and ground Between each terminal and non-current-carrying metal part Between lamp terminals Vibration Malfunction resistance Destruction Shock resistance Malfunction Momentary operation models: 120 operations/min max. *1 20 operations/min max. 100 MΩ min. (at 500 VDC) 50 mΩ max. (initial value) 50 mΩ max. (initial value) 1,000 VAC, 50/60 Hz for 1 minute 2,000 VAC, 50/60 Hz for 1 minute 2,000 VAC, 50/60 Hz for 1 minute 2,000 VAC, 50/60 Hz for 1 minute 1,000 VAC, 50/60 Hz for 1 minute *2 10 to 55 Hz, 1.5-mm double amplitude *3 500 m/s2 max. 200 m/s2 max. *3 Momentary operation models: 1,000,000 operations min. Alternate operation models: Life Mechanical 100,000 operations min. expect(One operation consists of set and ancy reset operations.) Electrical 100,000 operations min. (rated load) Weight Approx. 10 g NC Standard load: 10 A max. Inrush current NO Standard load: 10 A max. Ambient operating −10 to 50°C temperature (with no icing or condensation) Ambient operating humidity 35% to 85% RH −25 to 65°C Ambient storage temperature (with no icing or condensation) Degree of protection IP00 Electric shock protection class Class II PTI (proof tracking index) 175 Pollution degree 3 (IEC 60947-5-1) *1. With alternate operation models, 60 operations/min max. One operation cycle consists of set and reset operations. *2. With no incandescent lamp or LED lamp mounted. *3. Malfunction : 1 ms max. Operating Characteristics Standard lamp Rated current 200 mA 80 mA 40 mA Low-power lamp Rated current 100 mA 40 mA 25 mA Operation Operating characteristics Operating force Releasing force Total travel Pretravel Lock travel alternate Momentary Alternate operation models operation models OF max. RF min. TT PT max. 3.92 N 0.49 N Approx. 3 mm 2.2 mm 4.90 N 0.294 N Approx. 3 mm 2.2 mm LTA min. − 0.5 mm Contact Form Name Double-throw contacts Contact Form NC COM NO 12 A3S Nomenclature Model Structure Operation Unit Structure Color cap Legend plate * Dispersion plate LED/incandescent lamp holder * Not included for the Square Models (A3SA) with incandescent lamp. Operation Unit Rectangular Models A3SJ Square Models A3SA Screen pattern Single screen Vertical 2-split screen Operation Unit colors · LED-lighted models White , Red , Green , Yellow · Incandescent lamp-lighted model White , Red , Green , Blue , Yellow Lamp Socket Unit · Standard load 250 VAC, 2 A 125 VAC, 3 A 30 VDC, 2 A · Microload 125 VAC, 0.1 A 30 VDC, 0.1 A Lighting method · LED · Incandescent lamp Note: The A3SJ is shown here as an example. 13 A3S Dimensions (Unit: mm) The Dimension shows 2-switch outputs. Rectangular Models (A3SJ) OMRON logo Square Models (A3SA) 0.5 OMRON logo 19.4 14.1 8.2 0.5 13.2 19.1 22±0.2 4.5 13.2 15.8±0.2 13.2 17.8±0.2 15.8±0.2 2.8 24±0.2 1.8±0.1 4.2 15.8±0.2 1.8 1.2 17.8±0.2 10.4 2.8 Tab terminal #110 4.2 17.8±0.2 32.5 40 1.8±0.1 Tab terminal #110 32.5 40 Note: Unless specified, a tolerance of ±0.4 mm applies for all dimensions. Use a mounting panel thickness of 1 to 4 mm. Terminal Arrangement Bottom View (All are shown with the OMRON logo facing down.) Rectangular Models (A3SJ) SPDT NC1 11.8 LA+ SPDT 11.8 8.8 LA- LA+ NO1 NO2 LA- LB+ C1 LBLB+ NC1 8.8 11.8 C2 8.2 14.1 19.1 1.5 14.1 19.1 DPDT 0.5 0.5 NC1 NC2 LB- NO1 C1 Square Models (A3SA) DPDT L+ NO1 C1 1.5 8.8 L- 10.4 NC1 NC2 NO1 NO2 11.8 C1 2 L+ 8.8 L- C2 4.5 10.4 2 Note: The arrangements given above are not indicated on the Socket Unit. Contact Type Incandescent Lamp-lighted Models (The terminal arrangements are the same as for the LED-lighted models.) Type Model Rectangular Models (A3SJ) BOTTOM VIEW NC1 SPDT LA+ NO1 LA- Square Models (A3SA) BOTTOM VIEW LB+ C1 Terminal arrangement BOTTOM VIEW NC1 TOP VIEW NC1 LB- NO1 C1 DPDT TOP VIEW Lighting block TOP VIEW NC2 Terminal arrangement BOTTOM VIEW Lighting block TOP VIEW NC1 NC2 L+ NO1 LC1 NO2 C2 LA+ NO1 LBLANO2 LB+ C1 C2 Terminal arrangement L+ L- Lighting block Terminal arrangement Lighting block LED Lamp-lighted Models Type Model Rectangular Models (A3SJ) BOTTOM VIEW TOP VIEW Square Models (A3SA) BOTTOM VIEW TOP VIEW NC1 NC1 SPDT LA+ L+ LB- NO1 NO1 LAC1 C1 LB+ Terminal arrangement Lighting block BOTTOM VIEW NC1 DPDT TOP VIEW Terminal arrangement Lighting block BOTTOM VIEW TOP VIEW NC1 NC2 NC2 L+ NO1 LC1 NO2 C2 LA+ LBNO1 LB+ LANO2 C1 C2 Terminal arrangement L- Lighting block Terminal arrangement Lighting block 14 A3S Dimensions (Unit: mm) Panel Cutout (If using a Switch Guard or Seal Cover, refer to the panel cutout diagrams on page 17.) Rectangular Models (A3SJ) Classification Individual mounting, horizontal Multiple mounting, horizontal Flange mount models Individual mounting, vertical Mounting design Panel cutout 16.2 ±0.2 17.8 ±0.2 24 ±0.2 17.8 ±0.2 22.4 ±0.2 1 2 24n-1.6 ±0.2 24n ±0.5 Mount to Long Mounting Plate (A3SJ-3002) before use. 24 ±0.2 24 ±0.2 1 22.4 ±0.2 16.2 ±0.2 2 Mount to Long Mounting Plate (A3SJ-3002) before use. n 22.4 ±0.2 17.8n-1.6 ±0.2 16.2 ±0.2 19.8 26.9 ±0.2 29.7 Multiple mounting, horizontal Barrier mount models Individual mounting, vertical 19.8 1 2 n 25.3n+1.6 ±0.2 25.3n+4.4 Mount to Long Mounting Plate (A3SJ-3002) before use. 26 26 Panel cutout spacing between rows of Units: 16.2 ±0.2 1.4 4 min. 6 min. 22.4 ±0.2 20.7 ±0.2 23.5 Multiple mounting, vertical 3 min. 6 min. 17.8n ±0.5 Individual mounting, horizontal Panel cutout spacing between rows of Units: 16.2 ±0.2 n 17.8 ±0.2 Multiple mounting, vertical Remarks 1 2 n Mount to Long Mounting Plate (A3SJ-3002) before use. Dotted line indicates the position of each mounting Barrier. 22.4 ±0.2 19.1n+1.6 ±0.2 19.1n+4.4 * If the panel is to be finished (e.g., coated), make sure that the panel meets the specified dimensions after the coating. Square Models (A3SA) Classification Individual mounting Mounting design Panel cutout 16.2 ±0.2 17.8 ±0.2 3 min. Flange mount models 16.2 ±0.2 17.8 ±0.2 Multiple mounting 17.8 ±0.2 2 2 3 6 min. 16.2 ±0.2 n 17.8n ±0.5 Individual mounting Remarks Panel cutout spacing between rows of Units: 17.8n-1.6 ±0.2 Panel cutout spacing between rows of Units: 16.2 ±0.2 19.8 1.4 Barrier mount models 4 min. 20.7 ±0.2 23.5 6 min. Multiple mounting 19.8 1 2 3 19.1n+ 4.4 n 16.2 ±0.2 19.1n+1.6 ±0.2 Dotted line indicates the position of each mounting Barrier. * If the panel is to be finished (e.g., coated), make sure that the panel meets the specified dimensions after the coating. 15 A3S Dimensions (Unit: mm) Accessory Mounting Dimensions Legend Plate Rectangular Models A3SJ-4203/-4204 Extractor A3PJ-5080 Square Models A3SA-4203/-4204 0 18.4 -0.1 20 2.5 2.5 15 10 5 0 11.6 -0.1 0.3 50 0 0 11.6 -0.1 11.5 -0.1 0.8 25 ±2 0.8 Note: Made from stainless steel. Socket-mounting Dimensions Rectangular Models Wire-wrap Terminals A3SJ-4104 Solder Terminals A3SJ-4106 21.2 PCB Terminals A3SJ-4105 21.2 21.2 23.6 23.6 0.3 23.6 15 15 15 15.7 ±0.6 8.2 0.5 3.6 3 17.6 3 17.6 17.6 1.2 47.5 47.5 47.5 Terminal Hole Dimensions 0.9R PCB Cutout (Bottom View) 0.6R 3 3.2 2.9 1.5 0.8 11.8 8.8 1.5 2.9 Ten, 1.5-dia. holes 1.65 8.2 14.1 19.1 2.85 16 A3S Dimensions (Unit: mm) Square Models Wire-wrap Terminals A3SA-4101 Solder Terminals A3SA-4103 PCB Terminals A3SA-4102 21.2 21.2 21.2 0.3 17.6 17.6 17.6 15 15 15 8.2 15.7 ±0.6 0.5 3.6 3 3 17.6 17.6 17.6 1.2 47.5 47.5 47.5 PCB Cutout (bottom view) Terminal Hole Dimensions 0.9R 0.6R 5.0 3 3.2 2.9 10.4 4.5 2.2 0.8 11.8 8.8 Eight, 1.5-dia. holes The OMRON logo is downward on the Socket Unit. Switch and Guard Mounting Dimensions Rectangular Models A3SJ-5050 Panel Cutouts Individual Mounting 22.4±0.3 Panel Cutouts Square Models A3SA-5050 Individual Mounting 16.2±0.2 OMRON logo OMRON logo Transparent plate Transparent plate 16.2±0.2 16.2±0.2 20 20 26 Switch Guard (A3SJ-5050) Switch Guard (A3SA-5050) Multiple Mounting, horizontal Multiple Mounting, horizontal 20n-3.8±0.2 26n-3.6±0.2 +0 +0 16.2±0.2 20 -0.2 +0 26 -0.2 31.7 16.2±0.2 20 -0.2 +0 8.5 min. 20 -0.2 31.7 39.2 9±0.1 20 8.5 min. 39.2 9 ±0.1 Seal Cover Mounting Dimensions Panel Cutouts Rectangular Models ASJ-5060 Individual Mounting 22.4±0.3 Square Models A3SA-5060 Panel Cutouts Individual Mounting OMRON logo OMRON logo Transparent plate 16.2±0.2 Transparent plate 16.2±0.2 16.2±0.2 Seal Cover (A3SJ-5060) Black Multiple Mounting, horizontal 22.4±0.3 Seal Cover (A3SA-5060) 8.5 min. Black Multiple Mounting, horizontal 16.2±0.2 8.5 min. 16.2±0.2 24.3 31.8 30.5 8.3 24.3 8.5 min. 39.3 16.2±0.2 31.8 24.3 8.3 39.3 8.5 min. Note: 1. Recommended panel thickness: 1.0 to 3.3 mm 2. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. 17 A3S Safety Precautions Refer to Safety Precautions for All Pushbutton Switches/Indicators. Precautions for Correct Use Mounting LED Lamp • Always make sure that the power is turned OFF before mounting, removing, or wiring the Switch, or performing maintenance. Electric shock or fire may occur. • A current-limiting resistor for the LED lamp is built in, so no external resistor is required. Rated voltage 5 VDC 12 VDC 24 VDC Wiring • For wiring, use a wire size that is appropriate for the applied voltage and the supplied current. Be sure to perform soldering according to the following conditions. Using the Switch with incomplete soldering may result in errors and heat, which may cause fire. (1) Manual soldering: Use a soldering iron with a tip temperature of 350°C maximum and complete soldering within 3 seconds. (2) Dip soldering: Solder at 350°C for 3 s or less. Wait for one minute after soldering before exerting any external force on the solder. • Use non-corrosive liquid rosin as the flux. • If screw-tightened terminals are used, hold the Socket Unit Set or Socket Unit and install the lead wiring applying a torque of less than 0.98 N·m to the Socket Unit. Applying a torque of more than 0.98 N·m may result in damage. The tightening torque is 0.59 to 0.78 N·m. • Make sure that the insulating sheath of the wires does not come in contact with the Unit. If wiring is performed with the insulating sheath of the wires coming in contact with the Unit, use wire with a minimum heat resistance of 100°C. • After wiring the Switch, make sure that there is a suitable isolation distance. Operating Environment Built-in limiting resistance 39 Ω 270 Ω 1300 Ω Incandescent Lamp • It is advantageous in terms of service life and heat generation to apply 80% of the rated voltage (operating voltage) to the incandescent lamp. Operation • Always mount the Operation Unit before operating the Switch. (Using your fingers or tweezers to operate moving parts of the Switch may deform internal parts and cause malfunctions.) Character Film • If the character film is to be specially prepared, use heat-resistant film with a maximum thickness of 0.2 mm. 11.3 ±0.2 A3SJ A3SA 18.2 ±0.2 11.3 ±0.2 11.3 ±0.2 Others • If the panel is to be finished (e.g., coated), make sure that the panel meets the specified dimensions after the coating. • Do not use in locations that are subject to dust, oil, or metal fillings, because these may penetrate the interior the Switch and cause malfunction. Using Microloads Voltage (V) • Using a standard load switch when a microload circuit is opened or closed may cause wear on the contacts. Use the switch within the operating range. (Refer to the diagram below.) Even when using microload models within the operating range shown below, if inrush current occurs when the contacts are opened or closed, it may cause the contact surface to become rough, and so decrease life expectancy. Therefore, insert a contact protection circuit where necessary. The minimum applicable load is the N-level reference value. This value indicates the malfunction reference level for the reliability level of 60% (λ 60) (conforming to JIS C5003). The equation λ 60 = 0.5 x 10−6/time indicates that the estimated malfunction rate is less than 1/2,000,000 with a reliability level of 60%. 0.15 mA 26 mA 100 mA 30 24 Standard load area Microload area 12 Invalid area 5 0 0.1 100 mA 150 mA 1 mA 1 10 100 1,000 Current (mA) 18 A3S Application Replacing Incandescent and LED Lamps and Panel Mounting Removing the Display • Grasp the groove on the color cap surface, and pull it firmly toward you to remove the Display. • An Extractor (A3PJ-5080) is available to conveniently remove the Display. Barrier Mounting • Place the Edge Barrier on the side of the Socket Unit, and then insert it into the panel. • Insert the Intermediate Barrier between the Switches after inserting the Socket Units into the panel. Intermediate Barrier Edge Barrier Mounting and Replacing Incandescent and LED Lamps Inscribing Legend Plate Characters Inscribing A3SJ (M2SJ) • Inscription depth: 0.5 mm max. • The legend plate is made of polycarbonate, so apply an alcoholbased paint coating, such as melamine, phthalate, or acrylic resin paint when marking the legend. Inserting the Display into the Socket Unit Insert the Operation Unit in the proper direction. With the OMRON logo downward, insert the Operation Unit so that the lamp/LED terminals on the inside surface of the Unit case and the contactors of the Display. Terminals for incandescent or LED lamp (built into the case) Contactors Legend plate • When replacing the legend plate, be careful that the coil spring in the Display does not become removed. OMRON logo Rated Voltage and Color of LED The LED voltage rating is indicated on the base. Use the LED within ±5% of voltage range. Rated voltage Illuminating color (color band) Mounting to the Switch Panel Mount the Socket Unit to the panel by inserting it from the front of the panel. Mount the Socket Unit so that the OMRON logo is downward. 19 A3S Assembling the Legend Plate (Plunger) A3SA (M2SA) (LED Lamp) (1) Assemble the color plate to the plunger, and then assemble the legend plate on top. Legend plate Dispersion plate Plunger (Incandescent Lamp) (2) Inscribe the surface of the plunger, and then coat the surface. Lighted Square Pushbutton Switches Assemble models A3SA-5301 to A3SA-5305 so that the hook is toward you. Direction of inscription Hook toward you Note: Legend plates cannot be used with A3SA Displays for incandescent lamps. (3) Assemble the color cap to the inscribed plunger. Plunger Color cap (4) Push in the color in the direction of the arrow to assemble the plunger and the lamp holder. Lighted Square Pushbutton Switches A3SA Perform the assembly so that the wide groove and the hook on the plunger are in the same direction. Plunger Indicator M2SA Perform the assembly so that the wide groove and the hook on the plunger are in the same direction. 20 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2012.9 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2012 All Right Reserved.