E2B PROXIMITY SENSORS

E2B PROXIMITY SENSORS
A new generation in global applications
» Time and cost savings
» Per fect fit for stand ard e nv i ro nme nts
» Global deliveries and support
2
A new generation in global applications
We asked our customers: “What do you – as a
proximity sensor user - really want in a sensor?”
Some people wanted reliability in extreme
conditions. But most simply wanted reliable
performance in standard industrial environments.
These people also wanted attractive pricing, without
compromising quality. So we put to work our 50-year
heritage in proximity sensors: a heritage that has
seen 200 million Omron proximity sensors shipped
to satisfied customers across the globe. We put this
heritage to work as well as our understanding of
customer needs. The result is the new E2B sensor
range: designed to give you quality, reliability and
value-for-money.
• Perfect fit for standard environments
-372 models
-Single and double sensing distances
-M8, M12, M18 and M30
• Time and cost saving
• Global deliveries and support
Thanks to the simple construction and Omron’s
innovative “hot melt” production process, the
E2B sensors embody two seemingly contradictory
characteristics: value-for-money and high reliability.
3
Perfect fit for standard environments
The new E2B proximity sensors promise the perfect fit to your particular needs. With the wide range of models in
the E2B family, you can choose the one that exactly meets your needs. For example, we have four different sizes:
M8, M12, M18 and M30, each one with single or double sensing distances, shielded and unshielded. There’s
also a choice of short and long bodies, two connecting methods and four output types. With this range to choose
from, you’re certain to find the perfect fit.
Short/long bodies
ALL
372
Output configuration:
PNP/NPN
Operation mode:
NO/NC
Models
Long bodies for easy
adjustment after mounting
Shielded/unshielded
Pre-wired/Connectors
Shielded models for better
noise immunity
Connectors for easy maintenance
Wide range of size
Lineup of models from M8 to M30
Sensing distance
Models available with standard distance(×1) and double distance (×2)
0
M8
×1
M12
×1
×2
×2
5
4
10
15
20
“Double distance” saves space and
reduces costs
mm
With the double distance, you can get almost the same
sensing distance with a sensor that is one size smaller.
M18
8
mm
×1
M30
×1
M12
Standard
distance (×1)
Double
distance (×2)
×1
M18
25
16
×2
×2
mm
30
×2
Sensing distances of unshielded models
mm
30
4
Time and cost savings
For standard conditions you can easily select E2B sensors
because they have an easy-to-read code without complex
codification. They also have a bright circular LED indicator, so you
can quickly determine their operating status. These two features
reduce the effort in machine maintenance, so you will save time
and money.
All
ar
ou
nd
le
sib
i
V
360-degree indication
Easy visibility for 360° even in dark locations so you can mount
the sensor in any direction.
The ideal solution for standard industrial
environments
Pay only for what you need
Most industrial applications are conducted in a standard
environment, in a normal temperature range, without extremes
such as high oil- or water-pressure, or strong electromagnetic
fields, or constant high mechanical stresses. This makes E2B the
ideal solution for the vast majority of applications. It’s perfectly
reliable for normal conditions. What’s more, you get just what
you need without paying for unnecessary extreme robustness.
For example, in the machine-tool industry, E2B sensors are ideal
for detecting tool positions or line encoders. For packaging
machines they can be used for detecting the positions of welded
or pressed elements.
IP67
We have performed not only a specified test for rating the degree
of protection (IP67) for catalogs, but also tests with oil mist
which appears onsite. Simulation tests has been performed with
attachment of high concentration of oil mist.
Oil-mist environment resistant!
E2B
E2A
Feature
Superior price
Superior robustness
Oil/water resistance
Good
Good
IP
IP67
IP69K
Temperature
-25 to 70°C
-40 to 70°C
Other
Lineup of 2-wire models, and AC types
are available. NO+NC. Customization
5
Global deliveries and support
Our global network of 150 bases located in 40 countries ensure that we can support you with
products and services without delay. This global product and service availability is especially
important to those customers who manufacture machines in America for use in Asia, for
example.
Ideal for a wide range of applications
Suitable sensors can be selected among the wide variety of sensors in order to satisfy your
requirements. These sensors handle a wide range of applications, for example in machine tools
and packaging.
Machine tools
Cam detection
Position detection of
cylinder
Tension control
Packaging machines
Positioning on index
tables
E2B
Ordering Information
Sensing
distance
Size
Connecting
method
(See note 1.)
Body
length
Short
Pre-wired
Long
Shielded
1.5 mm
M8 Connector (3-pin)
Short
Long
Single
Short
Pre-wired
Long
Unshielded
2 mm
M8 Connector (3-pin)
M8
(Stainless steel)
(See note 2.)
Short
Long
Short
Pre-wired
Long
Shielded
2 mm
M8 Connector (3-pin)
Short
Long
Double
Short
Pre-wired
Long
Unshielded
4 mm
M8 Connector (3-pin)
Short
Long
Output
configuration
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
Operation mode NO
Operation mode NC
E2B-S08KS01-WP-B1 2M
E2B-S08KS01-WP-C1 2M
E2B-S08LS01-WP-B1 2M
E2B-S08LS01-WP-C1 2M
E2B-S08KS01-MC-B1
E2B-S08KS01-MC-C1
E2B-S08LS01-MC-B1
E2B-S08LS01-MC-C1
E2B-S08KN02-WP-B1 2M
E2B-S08KN02-WP-C1 2M
E2B-S08LN02-WP-B1 2M
E2B-S08LN02-WP-C1 2M
E2B-S08KN02-MC-B1
E2B-S08KN02-MC-C1
E2B-S08LN02-MC-B1
E2B-S08LN02-MC-C1
E2B-S08KS02-WP-B1 2M
E2B-S08KS02-WP-C1 2M
E2B-S08LS02-WP-B1 2M
E2B-S08LS02-WP-C1 2M
E2B-S08KS02-MC-B1
E2B-S08KS02-MC-C1
E2B-S08LS02-MC-B1
E2B-S08LS02-MC-C1
E2B-S08KN04-WP-B1 2M
E2B-S08KN04-WP-C1 2M
E2B-S08LN04-WP-B1 2M
E2B-S08LN04-WP-C1 2M
E2B-S08KN04-MC-B1
E2B-S08KN04-MC-C1
E2B-S08LN04-MC-B1
E2B-S08LN04-MC-C1
E2B-S08KS01-WP-B2 2M
E2B-S08KS01-WP-C2 2M
E2B-S08LS01-WP-B2 2M
E2B-S08LS01-WP-C2 2M
E2B-S08KS01-MC-B2
E2B-S08KS01-MC-C2
E2B-S08LS01-MC-B2
E2B-S08LS01-MC-C2
E2B-S08KN02-WP-B2 2M
E2B-S08KN02-WP-C2 2M
E2B-S08LN02-WP-B2 2M
E2B-S08LN02-WP-C2 2M
E2B-S08KN02-MC-B2
E2B-S08KN02-MC-C2
E2B-S08LN02-MC-B2
E2B-S08LN02-MC-C2
E2B-S08KS02-WP-B2 2M
E2B-S08KS02-WP-C2 2M
E2B-S08LS02-WP-B2 2M
E2B-S08LS02-WP-C2 2M
E2B-S08KS02-MC-B2
E2B-S08KS02-MC-C2
E2B-S08LS02-MC-B2
E2B-S08LS02-MC-C2
E2B-S08KN04-WP-B2 2M
E2B-S08KN04-WP-C2 2M
E2B-S08LN04-WP-B2 2M
E2B-S08LN04-WP-C2 2M
E2B-S08KN04-MC-B2
E2B-S08KN04-MC-C2
E2B-S08LN04-MC-B2
E2B-S08LN04-MC-C2
Note: 1. Pre-wired Models are available in the cable lengths of 2 m and 5 m.
2. Material specifications for stainless steel housing case: 1.4305 (W.-No.), SUS 303 (AISI), 2346 (SS).
Sensing
distance
Size
Connecting
method
(See note 1.)
Body
length
Short
Pre-wired
Long
Shielded
2 mm
M12
Connector
Short
Long
Single
Short
Pre-wired
Long
Unshielded
5 mm
M12
Connector
Short
Long
M12 (Brass)
Short
Pre-wired
Shielded
(See note 2.)
Long
4 mm
M12
Connector
Short
Long
Double
Short
Pre-wired
Long
Unshielded
8 mm
M12
Connector
Note: 1. Pre-wired Models are available in the cable lengths of 2 m and 5 m.
2. There are restrictions that apply to Shielded sensors.
Please refer to “Effects of Surrounding Metal” on page 20.
6
Short
Long
Output
configuration
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
Operation mode NO
Operation mode NC
E2B-M12KS02-WP-B1 2M
E2B-M12KS02-WP-C1 2M
E2B-M12LS02-WP-B1 2M
E2B-M12LS02-WP-C1 2M
E2B-M12KS02-M1-B1
E2B-M12KS02-M1-C1
E2B-M12LS02-M1-B1
E2B-M12LS02-M1-C1
E2B-M12KN05-WP-B1 2M
E2B-M12KN05-WP-C1 2M
E2B-M12LN05-WP-B1 2M
E2B-M12LN05-WP-C1 2M
E2B-M12KN05-M1-B1
E2B-M12KN05-M1-C1
E2B-M12LN05-M1-B1
E2B-M12LN05-M1-C1
E2B-M12KS04-WP-B1 2M
E2B-M12KS04-WP-C1 2M
E2B-M12LS04-WP-B1 2M
E2B-M12LS04-WP-C1 2M
E2B-M12KS04-M1-B1
E2B-M12KS04-M1-C1
E2B-M12LS04-M1-B1
E2B-M12LS04-M1-C1
E2B-M12KN08-WP-B1 2M
E2B-M12KN08-WP-C1 2M
E2B-M12LN08-WP-B1 2M
E2B-M12LN08-WP-C1 2M
E2B-M12KN08-M1-B1
E2B-M12KN08-M1-C1
E2B-M12LN08-M1-B1
E2B-M12LN08-M1-C1
E2B-M12KS02-WP-B2 2M
E2B-M12KS02-WP-C2 2M
E2B-M12LS02-WP-B2 2M
E2B-M12LS02-WP-C2 2M
E2B-M12KS02-M1-B2
E2B-M12KS02-M1-C2
E2B-M12LS02-M1-B2
E2B-M12LS02-M1-C2
E2B-M12KN05-WP-B2 2M
E2B-M12KN05-WP-C2 2M
E2B-M12LN05-WP-B2 2M
E2B-M12LN05-WP-C2 2M
E2B-M12KN05-M1-B2
E2B-M12KN05-M1-C2
E2B-M12LN05-M1-B2
E2B-M12LN05-M1-C2
E2B-M12KS04-WP-B2 2M
E2B-M12KS04-WP-C2 2M
E2B-M12LS04-WP-B2 2M
E2B-M12LS04-WP-C2 2M
E2B-M12KS04-M1-B2
E2B-M12KS04-M1-C2
E2B-M12LS04-M1-B2
E2B-M12LS04-M1-C2
E2B-M12KN08-WP-B2 2M
E2B-M12KN08-WP-C2 2M
E2B-M12LN08-WP-B2 2M
E2B-M12LN08-WP-C2 2M
E2B-M12KN08-M1-B2
E2B-M12KN08-M1-C2
E2B-M12LN08-M1-B2
E2B-M12LN08-M1-C2
E2B
Sensing
distance
Size
Connecting
method
(See note 1.)
Body
length
Short
Pre-wired
Long
Shielded
5 mm
M12
Connector
Short
Long
Single
Short
Pre-wired
Long
Unshielded
10 mm
M12
Connector
Short
Long
M18 (Brass)
Short
Pre-wired
Shielded
(See note 2.)
Long
8 mm
M12
Connector
Short
Long
Double
Short
Pre-wired
Long
Unshielded
16 mm
M12
Connector
Short
Long
Output
configuration
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
Operation mode NO
Operation mode NC
E2B-M18KS05-WP-B1 2M
E2B-M18KS05-WP-C1 2M
E2B-M18LS05-WP-B1 2M
E2B-M18LS05-WP-C1 2M
E2B-M18KS05-M1-B1
E2B-M18KS05-M1-C1
E2B-M18LS05-M1-B1
E2B-M18LS05-M1-C1
E2B-M18KN10-WP-B1 2M
E2B-M18KN10-WP-C1 2M
E2B-M18LN10-WP-B1 2M
E2B-M18LN10-WP-C1 2M
E2B-M18KN10-M1-B1
E2B-M18KN10-M1-C1
E2B-M18LN10-M1-B1
E2B-M18LN10-M1-C1
E2B-M18KS08-WP-B1 2M
E2B-M18KS08-WP-C1 2M
E2B-M18LS08-WP-B1 2M
E2B-M18LS08-WP-C1 2M
E2B-M18KS08-M1-B1
E2B-M18KS08-M1-C1
E2B-M18LS08-M1-B1
E2B-M18LS08-M1-C1
E2B-M18KN16-WP-B1 2M
E2B-M18KN16-WP-C1 2M
E2B-M18LN16-WP-B1 2M
E2B-M18LN16-WP-C1 2M
E2B-M18KN16-M1-B1
E2B-M18KN16-M1-C1
E2B-M18LN16-M1-B1
E2B-M18LN16-M1-C1
E2B-M18KS05-WP-B2 2M
E2B-M18KS05-WP-C2 2M
E2B-M18LS05-WP-B2 2M
E2B-M18LS05-WP-C2 2M
E2B-M18KS05-M1-B2
E2B-M18KS05-M1-C2
E2B-M18LS05-M1-B2
E2B-M18LS05-M1-C2
E2B-M18KN10-WP-B2 2M
E2B-M18KN10-WP-C2 2M
E2B-M18LN10-WP-B2 2M
E2B-M18LN10-WP-C2 2M
E2B-M18KN10-M1-B2
E2B-M18KN10-M1-C2
E2B-M18LN10-M1-B2
E2B-M18LN10-M1-C2
E2B-M18KS08-WP-B2 2M
E2B-M18KS08-WP-C2 2M
E2B-M18LS08-WP-B2 2M
E2B-M18LS08-WP-C2 2M
E2B-M18KS08-M1-B2
E2B-M18KS08-M1-C2
E2B-M18LS08-M1-B2
E2B-M18LS08-M1-C2
E2B-M18KN16-WP-B2 2M
E2B-M18KN16-WP-C2 2M
E2B-M18LN16-WP-B2 2M
E2B-M18LN16-WP-C2 2M
E2B-M18KN16-M1-B2
E2B-M18KN16-M1-C2
E2B-M18LN16-M1-B2
E2B-M18LN16-M1-C2
Operation mode NO
Operation mode NC
E2B-M30KS10-WP-B1 2M
E2B-M30KS10-WP-C1 2M
E2B-M30LS10-WP-B1 2M
E2B-M30LS10-WP-C1 2M
E2B-M30KS10-M1-B1
E2B-M30KS10-M1-C1
E2B-M30LS10-M1-B1
E2B-M30LS10-M1-C1
E2B-M30KN20-WP-B1 2M
E2B-M30KN20-WP-C1 2M
E2B-M30LN20-WP-B1 2M
E2B-M30LN20-WP-C1 2M
E2B-M30KN20-M1-B1
E2B-M30KN20-M1-C1
E2B-M30LN20-M1-B1
E2B-M30LN20-M1-C1
E2B-M30KS15-WP-B1 2M
E2B-M30KS15-WP-C1 2M
E2B-M30LS15-WP-B1 2M
E2B-M30LS15-WP-C1 2M
E2B-M30KS15-M1-B1
E2B-M30KS15-M1-C1
E2B-M30LS15-M1-B1
E2B-M30LS15-M1-C1
E2B-M30LN30-WP-B1 2M
E2B-M30LN30-WP-C1 2M
E2B-M30LN30-M1-B1
E2B-M30LN30-M1-C1
E2B-M30KS10-WP-B2 2M
E2B-M30KS10-WP-C2 2M
E2B-M30LS10-WP-B2 2M
E2B-M30LS10-WP-C2 2M
E2B-M30KS10-M1-B2
E2B-M30KS10-M1-C2
E2B-M30LS10-M1-B2
E2B-M30LS10-M1-C2
E2B-M30KN20-WP-B2 2M
E2B-M30KN20-WP-C2 2M
E2B-M30LN20-WP-B2 2M
E2B-M30LN20-WP-C2 2M
E2B-M30KN20-M1-B2
E2B-M30KN20-M1-C2
E2B-M30LN20-M1-B2
E2B-M30LN20-M1-C2
E2B-M30KS15-WP-B2 2M
E2B-M30KS15-WP-C2 2M
E2B-M30LS15-WP-B2 2M
E2B-M30LS15-WP-C2 2M
E2B-M30KS15-M1-B2
E2B-M30KS15-M1-C2
E2B-M30LS15-M1-B2
E2B-M30LS15-M1-C2
E2B-M30LN30-WP-B2 2M
E2B-M30LN30-WP-C2 2M
E2B-M30LN30-M1-B2
E2B-M30LN30-M1-C2
Note: 1. Pre-wired Models are available in the cable lengths of 2 m and 5 m.
2. There are restrictions that apply to Shielded sensors.
Please refer to “Effects of Surrounding Metal” on page 20.
Sensing
distance
Size
Connecting
method
(See note 1.)
Body
length
Short
Pre-wired
Long
Shielded
10 mm
M12
Connector
Short
Long
Single
Short
Pre-wired
Long
Unshielded
20 mm
M12
Connector
M30 (Brass)
Short
Long
Short
Pre-wired
Shielded
(See note 2.)
Long
15 mm
M12
Connector
Double
Unshielded
30 mm
Short
Long
Pre-wired
Long
M12
Connector
Long
Output
configuration
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
Note: 1. Pre-wired Models are available in the cable lengths of 2 m and 5 m.
2. There are restrictions that apply to Shielded sensors.
Please refer to “Effects of Surrounding Metal” on page 20.
7
E2B
Accessories (Order Separately)
Sensor I/O Connectors
Size
Cable
Shape
Cores
Straight
PVC
Right-angle
3
M8 (3-pin)
Straight
PVC Robot
Right-angle
Straight
PVC
Right-angle
4
M12 (4-pin)
Straight
PVC Robot
Right-angle
8
Cable length (m)
2
5
2
5
2
5
2
5
2
5
2
5
2
5
2
5
Model
XS3F-M8PVC3S2M
XS3F-M8PVC3S5M
XS3F-M8PVC3A2M
XS3F-M8PVC3A5M
XS3F-M321-302-R
XS3F-M321-305-R
XS3F-M322-302-R
XS3F-M322-305-R
XS2F-M12PVC4S2M
XS2F-M12PVC4S5M
XS2F-M12PVC4A2M
XS2F-M12PVC4A5M
XS2F-D421-D80-F
XS2F-D421-G80-F
XS2F-D422-D80-F
XS2F-D422-G80-F
E2B
Model Number Legend
E2B-@@@@@-@-@@ @
1
2 3 4 5 6
7
8 9 10
Example: E2B-M12LS04-M1-B1
E2B-S08KN02-WP-C2 5M
M12, Brass, Long body, Shielded, Sn = 4 mm, M12 connector, PNP, NO
M8, stainless steel, Short body, Unshielded, Sn = 2 mm, Pre-wired PVC cable, NPN, NC,
Cable length = 5 m
1. Basic name
E2B
2. Housing shape and material
M:
Cylindrical, metric threaded, brass
S:
Cylindrical, metric threaded, stainless steel
3. Housing size
08:
8 mm
12:
12 mm
18:
18 mm
30:
30 mm
4. Barrel length
K:
Short body
L:
Long body
5. Shield
S:
N:
Shielded
Unshielded
6. Sensing distance
Numeral: Sensing distance:
01 = 1.5 mm, 02 = 2 mm, 04 = 4 mm, 05 = 5 mm,
08 = 8 mm, 10 = 10 mm, 15 = 15 mm, 16 = 16 mm,
20 = 20 mm, 30 = 30 mm
7. Kind of connection
WP:
Pre-wired, PVC, dia 4 mm
M1:
M12 connector
MC:
M8 connector (3 pin)
8. Power source and output
B:
PNP
C:
NPN
9. Operation mode
1:
NO (Normally open)
2:
NC (Normally closed)
10.Cable length
Blank:
Connector type
Numeral: Cable length (2M and 5M are available.)
9
E2B
Ratings and Specifications
Size
Sensing
distance
Type
Item
Model
Sensing distance
Setting distance
Differential travel
Detectable object
Standard sensing object
(mild steel ST37)
Response frequency (See note 1.)
Power supply voltage
Current consumption
Output type
M8
Single
Double
Shielded
Unshielded
Shielded
E2B-S08@S01
E2B-S08@N02
E2B-S08@S02
1.5 mm ± 10%
2 mm ± 10%
2 mm ± 10%
0 to 1.2 mm
0 to 1.6 mm
0 to 1.6 mm
10% max. of sensing distance
Ferrous metal (The sensing distance decreases with non-ferrous metal.)
Unshielded
E2B-S08@N04
4 mm ± 10%
0 to 3.2 mm
8 × 8 × 1 mm
8 × 8 × 1 mm
12 × 12 × 1 mm
1,500 Hz
1,000 Hz
8 × 8 × 1 mm
2,000 Hz
1,000 Hz
10 to 30 VDC. (including 10% ripple (p-p))
10 mA max.
-B models: PNP open collector
-C models: NPN open collector
Load current
200 mA max. (30 VDC max.)
(See note 2.)
Residual voltage 2 V max. (under load current of 200 mA with cable length of 2 m)
Indicator
Operation indicator (Yellow LED)
Operation mode
-B1/-C1 models: NO
(with sensing object approaching) -B2/-C2 models: NC
Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor,
Protection circuit
Short-circuit protection
Ambient air temperature
Operation and storage : -25 to 70ºC (with no icing or condensation)
Temperature influence
±10% max. of sensing distance at 23ºC within temperature range of -10 to 55ºC
(See note 2.)
±15% max. of sensing distance at 23ºC within temperature range of -25 to 70ºC
Ambient humidity
Operation and Storage: 35 to 95%
Voltage influence
±1% max. of sensing distance in 24 V ±15%
Insulation resistance
50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength
1,000 VAC at 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance
500 m/s2, 10 times each in X, Y and Z directions
Standard and listings
(1) IP67 (IEC60529) (2) EMC (EN60947-5-2)
Pre-wired models (standard is 4 mm dia. PVC cable with length = 2 m, 5 m).
Connecting method
Connector models (M8-3pin)
Pre-wired model Short body: Approx. 65 g, Long body: Approx. 65 g
Weight
(packaged)
Connector model Short body: Approx. 20 g, Long body: Approx. 20 g
Case
Stainless steel (1.4305 (W.-No.), SUS 303 (AISI), 2346 (SS).)
Sensing surface PBT
Material
Cable
Standard cable is 4 mm dia. PVC.
Clamping nut
Brass-nickel plated
Control output
Note: 1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object
between sensing objects, and a setting distance of half the sensing distance.
2. When using any model of M8 size at an ambient temperature between -25ºC and 60ºC, use a load current of 200mA max., at an ambient temperature between
60ºC and 70ºC, use a load current of 100 mA max.
10
E2B
Size
Sensing
distance
Type
Item
Model
Sensing distance
Setting distance
Differential travel
Detectable object
Standard sensing object
(mild steel ST37)
Response frequency (See note 1.)
Power supply voltage
Current consumption
M12
Single
Double
Shielded
Unshielded
Shielded
E2B-M12@S02
E2B-M12@N05
E2B-M12@S04
2 mm ± 10%
5 mm ± 10%
4 mm ± 10%
0 to 1.6 mm
0 to 4 mm
0 to 3.2 mm
10% max. of sensing distance
Ferrous metal (The sensing distance decreases with non-ferrous metal.)
Unshielded
E2B-M12@N08
8 mm ± 10%
0 to 6.4 mm
12 × 12 × 1 mm
24 × 24 × 1 mm
15 × 15 × 1 mm
12 × 12 × 1 mm
1,500 Hz
800 Hz
1,000 Hz
800 Hz
10 to 30 VDC. (including 10% ripple (p-p))
10 mA max.
-B models: PNP open collector
Output type
-C models: NPN open collector
Load current
200 mA max. (30 VDC max.)
Control output
Residual voltage 2 V max. (under load current of 200 mA with cable length of 2 m)
Indicator
Operation indicator (Yellow LED)
Operation mode
-B1/-C1 models: NO
(with sensing object approaching) -B2/-C2 models: NC
Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor,
Protection circuit
Short-circuit protection
Ambient air temperature
Operation and storage : -25 to 70ºC (with no icing or condensation)
±10% max. of sensing distance at 23ºC within temperature range of -10 to 55ºC
Temperature influence
±15% max. of sensing distance at 23ºC within temperature range of -25 to 70ºC
Ambient humidity
Operation and Storage: 35 to 95%
Voltage influence
±1% max. of sensing distance in 24 V ±15%
Insulation resistance
50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength
1,000 VAC at 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance
1,000 m/s2, 10 times each in X, Y and Z directions
Standard and listings
(1) IP67 (IEC60529) (2) EMC (EN60947-5-2)
Pre-wired models (standard is 4 mm dia. PVC cable with length = 2 m, 5 m).
Connecting method
Connector models (M12-4pin)
Pre-wired
model
Short body: Approx. 75 g, Long body: Approx. 80 g
Weight
(packaged)
Connector model Short body: Approx. 35 g, Long body: Approx. 40 g
Case
Brass-nickel plated
Sensing surface PBT
Material
Cable
Standard cable is 4 mm dia. PVC.
Clamping nut
Brass-nickel plated
Note: 1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object
between sensing objects, and a setting distance of half the sensing distance.
11
E2B
Size
Sensing
distance
Type
Item
Model
Sensing distance
Setting distance
Differential travel
Detectable object
Standard sensing object
(mild steel ST37)
Response frequency (See note 1.)
Power supply voltage
Current consumption
M18
Single
Double
Shielded
Unshielded
Shielded
E2B-M18@S05
E2B-M18@N10
E2B-M18@S08
5 mm ± 10%
10 mm ± 10%
8 mm ± 10%
0 to 4 mm
0 to 8 mm
0 to 6.4 mm
10% max. of sensing distance
Ferrous metal (The sensing distance decreases with non-ferrous metal.)
Unshielded
E2B-M18@N16
16 mm ± 10%
0 to 12.8 mm
18 × 18 × 1 mm
48 × 48 × 1 mm
30 × 30 × 1 mm
24 × 24 × 1 mm
600 Hz
400 Hz
500 Hz
400 Hz
10 to 30 VDC. (including 10% ripple (p-p))
10 mA max.
-B models: PNP open collector
Output type
-C models: NPN open collector
Load current
200 mA max. (30 VDC max.)
Control output
Residual voltage 2 V max. (under load current of 200 mA with cable length of 2 m)
Indicator
Operation indicator (Yellow LED)
Operation mode
-B1/-C1 models: NO
(with sensing object approaching) -B2/-C2 models: NC
Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor,
Protection circuit
Short-circuit protection
Ambient air temperature
Operation and storage : -25 to 70ºC (with no icing or condensation)
±10% max. of sensing distance at 23ºC within temperature range of -10 to 55ºC
Temperature influence
±15% max. of sensing distance at 23ºC within temperature range of -25 to 70ºC
Ambient humidity
Operation and Storage: 35 to 95%
Voltage influence
±1% max. of sensing distance in 24 V ±15%
Insulation resistance
50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength
1,000 VAC at 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance
1,000 m/s2, 10 times each in X, Y and Z directions
Standard and listings
(1) IP67 (IEC60529) (2) EMC (EN60947-5-2)
Pre-wired models (standard is 4 mm dia. PVC cable with length = 2 m, 5 m).
Connecting method
Connector models (M12-4pin)
Pre-wired
model
Short
body: Approx. 95 g, Long body: Approx. 110 g
Weight
(packaged)
Connector model Short body: Approx. 60 g, Long body: Approx. 80 g
Case
Brass-nickel plated
Sensing surface PBT
Material
Cable
Standard cable is 4 mm dia. PVC.
Clamping nut
Brass-nickel plated
Note: 1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object
between sensing objects, and a setting distance of half the sensing distance.
12
E2B
Size
Sensing
distance
Type
Item
Model
Sensing distance
Setting distance
Differential travel
Detectable object
Standard sensing object
(mild steel ST37)
Response frequency (See note 1.)
Power supply voltage
Current consumption
M30
Single
Double
Shielded
Unshielded
Shielded
E2B-M30@S10
E2B-M30@N20
E2B-M30@S15
10 mm ± 10%
20 mm ± 10%
15 mm ± 10%
0 to 8 mm
0 to 16 mm
0 to 11.25 mm
10% max. of sensing distance
Ferrous metal (The sensing distance decreases with non-ferrous metal.)
Unshielded
E2B-M30@N30
30 mm ± 10%
0 to 22.5 mm
30 × 30 × 1 mm
90 × 90 × 1 mm
60 × 60 × 1 mm
45 × 45 × 1 mm
400 Hz
100 Hz
250 Hz
100 Hz
10 to 30 VDC. (including 10% ripple (p-p))
10 mA max.
-B models: PNP open collector
Output type
-C models: NPN open collector
Load current
200 mA max. (30 VDC max.)
Control output
Residual voltage 2 V max. (under load current of 200 mA with cable length of 2 m)
Indicator
Operation indicator (Yellow LED)
Operation mode
-B1/-C1 models: NO
(with sensing object approaching) -B2/-C2 models: NC
Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor,
Protection circuit
Short-circuit protection
Ambient air temperature
Operation and storage : -25 to 70ºC (with no icing or condensation)
±10% max. of sensing distance at 23ºC within temperature range of -10 to 55ºC
Temperature influence
±15% max. of sensing distance at 23ºC within temperature range of -25 to 70ºC
Ambient humidity
Operation and Storage: 35 to 95%
Voltage influence
±1% max. of sensing distance in 24 V ±15%
Insulation resistance
50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength
1,000 VAC at 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance
1,000 m/s2, 10 times each in X, Y and Z directions
Standard and listings
(1) IP67 (IEC60529) (2) EMC (EN60947-5-2)
Pre-wired models (standard is 4 mm dia. PVC cable with length = 2 m, 5 m).
Connecting method
Connector models (M12-4pin)
Pre-wired
model
Short body: Approx. 160 g, Long body: Approx. 210 g
Weight
(packaged)
Connector model Short body: Approx. 140 g, Long body: Approx. 160 g
Case
Brass-nickel plated
Sensing surface PBT
Material
Cable
Standard cable is 4 mm dia. PVC.
Clamping nut
Brass-nickel plated
Note: 1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object
between sensing objects, and a setting distance of half the sensing distance.
13
E2B
Engineering Data (Reference Value)
Influence of Sensing Object Size and Materials
Shielded Models
Unshielded Models
E2B-S08
E2B-S08@S01
E2B-S08@N04
4
3.5
Y
3
X
E2B-S08@S02
2.5
2
E2B-S08@S01
1.5
E2B-S08@N02
2.5
@d
Sensing distance X (mm)
4.5
Sensing distance X (mm)
M8
Sensing distance X (mm)
Operating Range
t = 1 mm
X
2
Iron
1.5
Stainless steel (SUS304)
1
2.5
@d
X
t = 1 mm
Iron
2
Stainless steel (SUS304)
1.5
Brass
1
Aluminium
1
E2B-S08@N02
Brass
0.5
Copper
0.5
Aluminium
0.5
Copper
0
-8
-6
-4
-2
0
2
4
6
0
8
5
10
15
20
25
0
Side length of sensing object d (mm)
Distance Y (mm)
@d
X
2.5
10
15
20
25
30
E2B-S08@N04
3
Sensing distance X (mm)
Sensing distance X (mm)
E2B-S08@S02
5
Side length of sensing object d (mm)
t = 1 mm
Iron
2
1.5
Stainless steel (SUS304)
1
6
@d
X
t = 1 mm
5
Iron
4
3
Stainless steel (SUS304)
2
Brass
Brass
Aluminium
Aluminium
0.5
1
Copper
Copper
0
5
10
15
20
25
0
Side length of sensing object d (mm)
20
30
Influence of Sensing Object Size and Materials
Shielded Models
Unshielded Models
E2B-M12
E2B-M12@S02
E2B-M12@N08
8
7
Y
6
E2B-M12@N05
X
5
4
E2B-M12@S04
3
2
2.5
@d
X
t = 1 mm
Iron
2
1.5
Stainless steel (SUS304)
1
Brass
50
60
70
6
Iron
5
@d
X
t = 1 mm
4
3
Stainless steel (SUS304)
Brass
2
Aluminium
Aluminium
E2B-M12@S02
0.5
Copper
1
Copper
1
0
-16
40
E2B-M12@N05
Sensing distance X (mm)
9
Sensing distance X (mm)
M12
Sensing distance X (mm)
Operating Range
10
Side length of sensing object d (mm)
-12
-8
-4
0
4
8
12
16
0
5
10
15
20
25
0
Side length of sensing object d (mm)
Distance Y (mm)
5
@d
X
20
30
40
50
60
70
80 90
E2B-M12@N08
Sensing distance X (mm)
Sensing distance X (mm)
E2B-M12@S04
10
Side length of sensing object d (mm)
t = 1 mm
Iron
4
Stainless steel (SUS304)
3
Brass
2
Aluminium
9
Iron
8
@d
X
7
t = 1 mm
6
5
Stainless steel (SUS304)
4
Brass
3
Aluminium
Copper
Copper
2
1
1
0
5
10
15
20
25
30
35
Side length of sensing object d (mm)
14
0
10
20
30
40
50
60
70
80 90
Side length of sensing object d (mm)
E2B
Influence of Sensing Object Size and Materials
Shielded Models
Unshielded Models
E2B-M18
E2B-M18@S05
E2B-M18@N16
16
14
Y
X
12
E2B-M18@N10
10
8
E2B-M18@S08
6
6
@d
E2B-M18@N10
Sensing distance X (mm)
18
Sensing distance X (mm)
M18
Sensing distance X (mm)
Operating Range
t = 1 mm
X
Iron
5
4
Stainless steel (SUS304)
3
Brass
2
Aluminium
12
@d
X
t = 1 mm
Iron
10
8
Stainless steel (SUS304)
6
Brass
4
Aluminium
E2B-M18@S05
Copper
4
Copper
1
2
2
0
-30
-20
-10
0
10
20
30
0
10
20
30
40
50
60
70
0
80 90
Side length of sensing object d (mm)
Distance Y (mm)
8
Iron
7
Stainless steel (SUS304)
6
5
Brass
4
Aluminium
3
2
Copper
@d
X
t = 1 mm
18
@d
16
40
X
Stainless steel (SUS304)
10
8
Brass
Aluminium
6
Copper
2
10
20
30
40
50
60
70
80 90
0
10
20
30
40
15
t = 1 mm
Iron
10
8
Stainless steel (SUS304)
6
Brass
4
Y
0
-60
-40
-20
0
20
40
60
0
X
10
20
30
40
50
60
70
Iron
15
Stainless steel (SUS304)
10
Brass
@d
X
Copper
0
10
20
30
40
50
60
70
80
90 100
Side length of sensing object d (mm)
E2B-M30LN30
E2B-M30@S15
20
80 90
t = 1 mm
20
Side length of sensing object d (mm)
Distance Y (mm)
@d
5
2
E2B-M30@S10
70
Aluminium
Copper
X
5
25
Aluminium
t = 1 mm
16
Iron
12
Stainless steel (SUS304)
8
Brass
Aluminium
Sensing distance X (mm)
10
E2B-M30@S15
X
60
E2B-M30@N20
Sensing distance X (mm)
20
Sensing distance X (mm)
E2B-M30@N20
Sensing distance X (mm)
Sensing distance X (mm)
25
@d
50
Side length of sensing object d (mm)
E2B-M30@S10
30
80 90
12
E2B-M30
E2B-M30@N30
70
Iron
Influence of Sensing Object Size and Materials
Shielded Models
Unshielded Models
12
60
t = 1 mm
M30
35
50
14
Side length of sensing object d (mm)
Operating Range
30
4
1
0
20
E2B-M18@N16
9
Sensing distance X (mm)
Sensing distance X (mm)
E2B-M18@S08
10
Side length of sensing object d (mm)
35
@d
X
30
t = 1 mm
Iron
25
Stainless steel (SUS304)
20
Brass
15
Aluminium
10
Copper
Copper
4
5
0
10
20
30
40
50
60
70
80
90 100
Side length of sensing object d (mm)
0
10
20
30
40
50
60
70
80
90 100
Side length of sensing object d (mm)
15
E2B
I/O Circuit Diagrams
PNP Output
Operation mode
Model
Timing chart
Non-sensing zone
Output circuit
Sensing zone
Proximity
Sensor
Sensing
object
(%)
100
Brown 1
0
Rated
sensing
distance
NO
ON
OFF
ON
OFF
Yellow indicator
Black 4
main
circuits
10 to 30
VDC
Load
Control output
Blue 3
E2B-S08@-@-B@
Non-sensing zone
Sensing zone
Proximity
Sensor
M8 connector
(3 pin)
Pin Arrangement
Sensing
object
(%)
100
0
4
Rated
sensing
distance
NC
3
1
ON
OFF
Yellow indicator
ON
OFF
Non-sensing zone
Sensing zone
Control output
Proximity
Sensor
Sensing
object
(%)
100
Brown 1
0
Rated
sensing
distance
NO
ON
OFF
ON
OFF
Yellow indicator
Black 4 or 2
main
circuits
Load
Control output
Blue 3
E2B-M12@-@-B@
E2B-M18@-@-B@
E2B-M30@-@-B@
4 : NO
2 : NC
Non-sensing zone
Sensing zone
Proximity
Sensor
Sensing
object
(%)
100
0
1
Rated
sensing
distance
NC
2
4
3
ON
OFF
Yellow indicator
ON
OFF
16
M12 Connector
(4 pin)
Pin Arrangement
Control output
10 to 30
VDC
E2B
NPN Output
Operation mode
Model
Timing chart
Non-sensing zone
Output circuit
Sensing zone
Proximity
Sensor
Sensing
object
(%)
100
Brown 1
0
Rated
sensing
distance
NO
Load
ON
OFF
ON
OFF
Yellow indicator
main
circuits
10 to 30
VDC
Black 4
Control output
Blue 3
E2B-S08@-@-C@
Non-sensing zone
Sensing zone
Proximity
Sensor
M8 connector
(3 pin)
Pin Arrangement
Sensing
object
(%)
100
0
4
Rated
sensing
distance
NC
3
1
ON
OFF
Yellow indicator
ON
OFF
Non-sensing zone
Sensing zone
Control output
Proximity
Sensor
Sensing
object
(%)
100
Brown 1
0
Rated
sensing
distance
NO
Load
ON
OFF
ON
OFF
Yellow indicator
main
circuits
Black 4 or 2
Control output
Blue 3
E2B-M12@-@-C@
E2B-M18@-@-C@
E2B-M30@-@-C@
4 : NO
2 : NC
Non-sensing zone
Sensing zone
Proximity
Sensor
Sensing
object
(%)
100
M12 Connector
(4 pin)
Pin Arrangement
0
1
Rated
sensing
distance
NC
10 to 30
VDC
2
4
3
ON
OFF
Yellow indicator
ON
OFF
Control output
17
E2B
Dimensions
Note: All units are in millimeters unless otherwise indicated.
M8 Size
Pre-wired Models (Shielded)
Short Body
Pre-wired Models (Unshielded)
E2B-S08KS01-WP-@@/E2B-S08KS02-WP-@@
E2B-S08KN02-WP-@@/E2B-S08KN04-WP-@@
42
42
27
4
13
Operating indicator
(yellow LED,4×90°)
6
13
27
4
Operating indicator
(yellow LED,4×90°)
6.6 dia.
4-dia. vinyl-insulated round cable with 3 conductors
(conductor cross section : 0.141 mm² ;
insulator diameter : 0.85 mm) ; standard length : 2 m
M8×P1
Two,clamping nuts
4-dia. vinyl-insulated round cable with 3 conductors
(conductor cross section : 0.141 mm² ;
insulator diameter : 0.85 mm) ; standard length : 2 m
M8×P1
Two,clamping nuts
Long Body
E2B-S08LS01-WP-@@/E2B-S08LS02-WP-@@
E2B-S08LN02-WP-@@/E2B-S08LN04-WP-@@
64
64
49
49
4
13
Operating indicator
(yellow LED,4×90°)
6
13
Operating indicator
(yellow LED,4×90°)
4
6.6 dia.
Two,clamping nuts
Connector Models (Shielded)
Short Body
4-dia. vinyl-insulated round cable with 3 conductors
(conductor cross section : 0.141 mm² ;
insulator diameter : 0.85 mm) ; standard length : 2 m
M8×P1
4-dia. vinyl-insulated round cable with 3 conductors
(conductor cross section : 0.141 mm² ;
insulator diameter : 0.85 mm) ; standard length : 2 m
M8×P1
Two,clamping nuts
Connector Models (Unshielded)
E2B-S08KS01-MC-@@/E2B-S08KS02-MC-@@
E2B-S08KN02-MC-@@/E2B-S08KN04-MC-@@
44
44
27
4
13
Operating indicator
(yellow LED,4×90°)
6
13
27
4
Operating indicator
(yellow LED,4×90°)
6.6 dia.
M8×P1
M8×P1
Two,clamping nuts
M8×P1
M8×P1
Two,clamping nuts
Long Body
E2B-S08LS01-MC-@@/E2B-S08LS02-MC-@@
E2B-S08LN02-MC-@@/E2B-S08LN04-MC-@@
66
66
49
49
4
13
Operating indicator
(yellow LED,4×90°)
6
13
4
Operating indicator
(yellow LED,4×90°)
6.6 dia.
M8×P1
M8×P1
M8×P1
Two,clamping nuts
M8×P1
Two,clamping nuts
Mounting Hole Cutout Dimensions
External diameter
Dimension F (mm) Dimension G (mm)
of Proximity Sensor
M8
8.5 dia.+0.5
13
0
F
18
G
E2B
M12 Size
Pre-wired Models (Shielded)
Short Body
Pre-wired Models (Unshielded)
E2B-M12KS02-WP-@@/E2B-M12KS04-WP-@@
47
30
E2B-M12KN05-WP-@@/E2B-M12KN08-WP-@@
47
7.9
4
17
7.9
30
17
Operating indicator
(yellow)
4
7
Operating indicator
(yellow)
10.5 dia.
M12×P1
M12×P1
4-dia. vinyl-insulated round cable with 3 conductors
(conductor cross section : 0.141 mm² ;
insulator diameter : 0.85 mm) ; standard length : 2 m
Two,clamping nuts
4-dia. vinyl-insulated round cable with 3 conductors
(conductor cross section : 0.141 mm² ;
insulator diameter : 0.85 mm) ; standard length : 2 m
Two,clamping nuts
Long Body
E2B-M12LS02-WP-@@/E2B-M12LS04-WP-@@
70
70
7.9
53
17
E2B-M12LN05-WP-@@/E2B-M12LN08-WP-@@
Operating indicator
(yellow)
4
7.9
53
17
4
7
Operating indicator
(yellow)
10.5 dia.
M12×P1
4-dia. vinyl-insulated round cable with 3 conductors
(conductor cross section : 0.141 mm² ;
insulator diameter : 0.85 mm) ; standard length : 2 m
Two,clamping nuts
Connector Models (Shielded)
Short Body
M12×P1
4-dia. vinyl-insulated round cable with 3 conductors
(conductor cross section : 0.141 mm² ;
insulator diameter : 0.85 mm) ; standard length : 2 m
Two,clamping nuts
Connector Models (Unshielded)
E2B-M12KS02-M1-@@/E2B-M12KS04-M1-@@
E2B-M12KN05-M1-@@/E2B-M12KN08-M1-@@
51
51
31
17
4
31
Operating indicator
(yellow LED 4×90°)
17
4
7
Operating indicator
(yellow LED 4×90°)
10.5 dia.
M12×P1
M12×P1
Two,clamping nuts
M12×P1
M12×P1
Two,clamping nuts
Long Body
E2B-M12LS02-M1-@@/E2B-M12LS04-M1-@@
E2B-M12LN05-M1-@@/E2B-M12LN08-M1-@@
74
74
54
17
4
54
Operating indicator
(yellow LED 4×90°)
17
7
4
Operating indicator
(yellow LED 4×90°)
10.5 dia.
M12×P1
Two,clamping nuts
M12×P1
M12×P1
M12×P1
Two,clamping nuts
Mounting Hole Cutout Dimensions
External diameter
Dimension F (mm) Dimension G (mm)
of Proximity Sensor
M12
12.5 dia.+0.5
17
0
F
G
19
E2B
M18 Size
Pre-wired Models (Shielded)
Short Body
Pre-wired Models (Unshielded)
E2B-M18KS05-WP-@@/E2B-M18KS08-WP-@@
E2B-M18KN10-WP-@@/E2B-M18KN16-WP-@@
56
56
36
24
36
5.6
Operating indicator
(yellow)
4
24
5.6
4
10
Operating indicator
(yellow)
16.4 dia.
M18×P1
4-dia. vinyl-insulated round cable with 3 conductors
(conductor cross section : 0.141 mm² ;
insulator diameter : 0.85 mm) ; standard length : 2 m
Two,clamping nuts
M18×P1
4-dia. vinyl-insulated round cable with 3 conductors
(conductor cross section : 0.141 mm² ;
insulator diameter : 0.85 mm) ; standard length : 2 m
Two,clamping nuts
Long Body
E2B-M18LS05-WP-@@/E2B-M18LS08-WP-@@
E2B-M18LN10-WP-@@/E2B-M18LN16-WP-@@
78
78
58
24
58
4
5.6
Operating indicator
(yellow)
4
24
10
5.6
Operating indicator
(yellow)
16.4 dia.
M18×P1
4-dia. vinyl-insulated round cable with 3 conductors
(conductor cross section : 0.141 mm² ;
insulator diameter : 0.85 mm) ; standard length : 2 m
Two,clamping nuts
Connector Models (Shielded)
Short Body
M18×P1
4-dia. vinyl-insulated round cable with 3 conductors
(conductor cross section : 0.141 mm² ;
insulator diameter : 0.85 mm) ; standard length : 2 m
Two,clamping nuts
Connector Models (Unshielded)
E2B-M18KS05-M1-@@/E2B-M18KS08-M1-@@
E2B-M18KN10-M1-@@/E2B-M18KN16-M1-@@
59
59
39
39
24
Operating indicator
(yellow LED 4×90°)
4
10
24
Operating indicator
(yellow LED 4×90°)
4
10
16.4 dia.
M18×P1
M12×P1
M18×P1
Two,clamping nuts
M12×P1
Two,clamping nuts
Long Body
E2B-M18LS05-M1-@@/E2B-M18LS08-M1-@@
E2B-M18LN10-M1-@@/E2B-M18LN16-M1-@@
81
81
61
4
24
Operating indicator
(yellow LED 4×90°)
24
10
61
4
Operating indicator
(yellow LED 4×90°)
16.4 dia.
M12×P1
M18×P1
M18×P1
Two,clamping nuts
M12×P1
Two,clamping nuts
Mounting Hole Cutout Dimensions
External diameter
Dimension F (mm) Dimension G (mm)
of Proximity Sensor
M18
18.5 dia.+0.5
24
0
F
20
G
E2B
M30 Size
Pre-wired Models (Shielded)
Short Body
Pre-wired Models (Unshielded)
E2B-M30KS10-WP-@@/E2B-M30KS15-WP-@@
60
60
6.1
41
5
36
E2B-M30KN20-WP-@@
6.1
41
36
5
15
Operating indicator
(yellow)
Operating indicator
(yellow)
27.8 dia.
4-dia. vinyl-insulated round cable with 3 conductors
(conductor cross section : 0.141 mm² ;
insulator diameter : 0.85 mm) ; standard length : 2 m
M30×P1.5
Two,clamping nuts
4-dia. vinyl-insulated round cable
with 3 conductors (conductor cross section :
0.141 mm² ; insulator diameter : 0.85 mm) ;
standard length : 2 m
M30×P1.5
Two,clamping nuts
Long Body
E2B-M30LS10-WP-@@/E2B-M30LS15-WP-@@
82
82
6.1
63
36
E2B-M30LN20-WP-@@/E2B-M30LN30-WP-@@
Operating indicator
(yellow)
5
6.1
63
5
36
Operating indicator
(yellow)
15
27.8 dia.
M30×P1.5
Two,clamping nuts
4-dia. vinyl-insulated round cable with 3 conductors
(conductor cross section : 0.141 mm² ;
insulator diameter : 0.85 mm) ; standard length : 2 m
Connector Models (Shielded)
Short Body
4-dia. vinyl-insulated round cable
with 3 conductors (conductor cross section :
0.141 mm² ; insulator diameter : 0.85 mm) ;
standard length : 2 m
M30×P1.5
Two,clamping nuts
Connector Models (Unshielded)
E2B-M30KS10-M1-@@/E2B-M30KS15-M1-@@
E2B-M30KN20-M1-@@
64
64
Operating indicator
(yellow LED 4×90°)
44
5
36
Operating indicator
(yellow LED 4×90°)
44
36
5
15
27.8 dia.
M12×P1
M12×P1
M30×P1.5
M30×P1.5
Two,clamping nuts
Two,clamping nuts
Long Body
E2B-M30LS10-M1-@@/E2B-M30LS15-M1-@@
E2B-M30LN20-M1-@@/E2B-M30LN30-M1-@@
86
86
Operating indicator
(yellow LED 4×90°)
66
36
5
66
5
36
Operating indicator
(yellow LED 4×90°)
15
27.8 dia.
M12×P1
M12×P1
M30×P1.5
M30×P1.5
Two,clamping nuts
Two,clamping nuts
Mounting Hole Cutout Dimensions
External diameter
Dimension F (mm) Dimension G (mm)
of Proximity Sensor
M30
30.5 dia.+0.5
36
0
F
G
21
E2B
Accessories (Order Separately)
Sensor I/O Connectors
M8 Connector (3 pin)
PVC Type
(Unit: mm)
Straight
XS3F-M8PVC3S2M (L = 2 m)
XS3F-M8PVC3S5M (L = 5 m)
L(Cable length)
M8×P1
31.9
21.5
4
3
1
5 dia.
9 dia.
5
30
Model
Right-angle
XS3F-M8PVC3A2M (L = 2 m)
XS3F-M8PVC3A5M (L = 5 m)
50
Lot No.
L(Cable length)
5 dia.
23.1
5
21
30
Model
50
Lot No.
9 dia.
1
4
3
M8×P1
PVC Robot Type
Straight
XS3F-M321-302-R (L = 2 m)
XS3F-M321-305-R (L = 5 m)
M8×P1
4 dia.
4
3
1
9 dia.
21.5
30
31.4
Right-angle
XS3F-M322-302-R (L = 2 m)
XS3F-M322-305-R (L = 5 m)
30
20.5
4 dia.
9 dia.
1
4
3
M8×P1
Pin arrangement
4
3
22
1
1-Brown
3-Blue
4-Black
50
L (Cable length)
23.1
5
50
L (Cable length)
5
E2B
Sensor I/O Connectors
M12 Connector (4 pin)
PVC Type
Straight
XS2F-M12PVC4S2M (L = 2 m)
XS2F-M12PVC4S5M (L = 5 m)
L(Cable length)
40.7
1
2
4
3
5 dia.
Model
14.9 dia.
5
30
Lot No.
M12 × P1
Right-angle
XS2F-M12PVC4A2M (L = 2 m)
XS2F-M12PVC4A5M (L = 5 m)
50
L(Cable length)
25.3
5 dia.
Model
5
30
28.3
Lot No.
50
14.9 dia.
3
2
M12 × P1
4
1
PVC Robot Type
Straight
XS2F-D421-D80-F (L = 2 m)
XS2F-D421-G80-F (L = 5 m)
M12×P1
1
2
4
3
6 dia.
14.9 dia.
30
40.7
L (Cable length)
Right-angle
XS2F-D422-D80-F (L = 2 m)
XS2F-D422-G80-F (L = 5 m)
50
L (Cable length)
30
25.3
5
50
5
28.3
6 dia.
14.9 dia.
3
2
4
1
M12×P1
Pin arrangement
1
4
2
3
1-Brown
2-White
3-Blue
4-Black
23
E2B
Precautions
Wiring
WARNING
Be sure to wire the E2B and load correctly, otherwise it may be
damaged.
This product is not designed or rated for ensuring
safety of persons. Do not use it for such purpose.
Connection with No Load
Be sure to insert loads when wiring. Make sure to connect a proper
load to the E2B in operation, otherwise it may damage internal
elements.
Never use this product with an AC power supply.
Otherwise, explosion may result.
Do not expose the product to flammable or explosive
gases.
Do not disassemble, repair, or modify the product.
Safety Precautions
Load Short-circuit
Do not short-circuit the load, or the E2B may be damaged.
The E2B’s short-circuit protection function will be valid if the polarity
of the supply voltage imposed is correct and within the rated voltage
range.
Correct Use
Designing
Power Reset Time
The Proximity Sensor is ready to operate within 100 ms after power is
supplied. If power supplies are connected to the Proximity Sensor and
load respectively, be sure to supply power to the Proximity Sensor
before supplying power to the load.
Effects of Surrounding Metal
When mounting the proximity sensor within a metal panel, ensure that
the clearances given in the Table1 are maintained. Failure to maintain
these distance may cause deterioration in the performance of the
sensor.
Table 1
Single Sensing Distance Type
<Shielded>
<Unshielded>
l
l
n
m
d dia.
D
m
n
m
d dia.
D
m
l
l
(Unit: mm)
Item
l
d
D
m
n
Size
M8
M12
M18
0
8
0
4.5
12
0
12
0
8
18
M30
0
18
0
20
27
0
30
0
40
45
Double Sensing Distance Type
<Shielded>
(Unit: mm)
Item
l
d
D
m
n
Size
M8
M12
6
24
6
8
24
M18
15
40
15
20
36
M30
22
55
22
40
54
<Unshielded>
l
l
n
m
d dia.
D
m
n
m
d dia.
D
m
l
l
(Unit: mm)
Item
l
d
D
m
n
24
30
90
30
70
90
Size
M8
M12
0
8
0
4.5
12
M18
2.4
18
2.4
12
18
M30
3.6
27
3.6
24
27
6
45
6
45
45
(Unit: mm)
Item
l
d
D
m
n
Size
M8
M12
12
24
12
8
24
M18
15
40
15
20
40
M30
25
70
25
48
70
45
140
45
90
140
E2B
Power OFF
The Proximity Sensor may output a pulse signal when it is turned
OFF. Therefore,it is recommended that the load be turned OFF
before turning OFF the Proximity Sensor.
Power Supply Transformer
When using a DC power supply, make sure that the DC power supply
has an insulated transformer. Do not use a DC power supply with an
auto-transformer.
Mutual Interference
When installing two or more proximity sensors face to face or side by
side, ensure that the minimum distances given in the Table2 are
maintained.
Table 2
Unit: (mm)
Size
M8
M12
M18
M30
Type
Shielded
Unshielded
Shielded
Unshielded
Shielded
Unshielded
Shielded
Unshielded
Model
S08@S01 S08@S02 S08@N02 S08@N04 M12@S02 M12@S04 M12@N05 M12@N08 M18@S05 M18@S08 M18@N10 M18@N16 M30@S10 M30@S15 M30@N20 M30@N30
E2B-( )
A
20
20
80
80
30
30
120
120
50
60
200
200
100
110
300
350
B
15
15
60
60
20
20
100
100
35
35
110
120
70
90
200
300
Wiring
High-tension Lines
Maintenance and Inspection
Wiring through Metal Conduit:
If there is a power or high-tension line near the cable of the Proximity
Sensor, wire the cable through an independent metal conduit to
prevent against Proximity Sensor damage or malfunctioning.
Cable Extension
Standard cable length is less than 200 m.
The tractive force is 50 N.
Mounting
Do not tighten the sensor mounting nuts with excessive force.
Table 3
(Shielded)
(Unshielded)
Size
M8
M12
M18
M30
Torque
7 N·m
12 N·m
30 N·m
50 N·m
Periodically perform the following checks to ensure stable operation
of the Proximity Sensor over a long period of time.
1. Check for mounting position, dislocation, looseness, or distortion
of the Proximity Sensor and sensing objects.
2. Check for loose wiring and connections, improper contacts, and
line breakage.
3. Check for attachment or accumulation of metal powder or dust.
4. Check for abnormal temperature conditions and other environmental conditions.
5. Check for proper lighting of indicators (for models with a set indicator.)
Never disassemble or repair the Sensor.
Environment
Water Resistivity
The Proximity Sensors are tested intensively on water resistance, but
in order to ensure maximum performance and life expectancy avoid
immersion in water and provide protection from rain or snow.
Operating Environment
Ensure storage and operation of the Proximity Sensor within the given
specifications.
Inrush Current
A load that has a large inrush current (e.g., a lamp or motor) will
damage the Proximity Sensor, in which case connect the load to the
Proximity Sensor through a relay.
<SUITABILITY FOR USE>
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of the products in the
customer’s application or use of the products.
Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will be used.
<CHANGE IN SPECIFICATIONS>
Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with your OMRON
representative at any time to confirm actual specifications of purchased product.
25
MEMO
26
MEMO
27
READ AND UNDERSTAND THIS DOCUMENT
Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or comments.
WARRANTY
OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR
PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET
THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY
CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON’S ANALYSIS
CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE,
OR INAPPROPRIATE MODIFICATION OR REPAIR.
SUITABILITY FOR USE
THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF PERSONS, AND
SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES. Please refer to separate catalogs for OMRON's safety rated
products.
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer’s application or use of the
product.
At the customer’s request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by
itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is
it intended to imply that the uses listed may be suitable for the products:
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document.
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations
subject to separate industry or government regulations.
• Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS
BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL
EQUIPMENT OR SYSTEM.
PERFORMANCE DATA
Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s
test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability.
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of
the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request.
Please consult with your OMRON representative at any time to confirm actual specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading
errors, or omissions.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof.
COPYRIGHT AND COPY PERMISSION
This document shall not be copied for sales or promotions without permission.
This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this document in any manner,
for any other purpose. If copying or transmitting this document to another, please copy or transmit it in its entirety.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON Corporation
Industrial Automation Company
Authorized Distributor:
Tokyo, JAPAN
Contact: www.ia.omron.com
Regional Headquarters
OMRON EUROPE B.V.
Sensor Business Unit
Carl-Benz-Str. 4, D-71154 Nufringen, Germany
Tel: (49) 7032-811-0/Fax: (49) 7032-811-199
OMRON ELECTRONICS LLC
One Commerce Drive Schaumburg,
IL 60173-5302 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
© OMRON Corporation 2013 All Rights Reserved.
In the interest of product improvement,
specifications are subject to change without notice.
CSM_1_2_1113
Printed in Japan
Cat. No. D118-E1-01
0613(0613)