BAND PASS FILTER CONNECTORIZED MODEL: TFIS-10.7 Fc = 70 MHz OPTIMIZED BANDWIDTH FEATURES: ► Low Loss ► Small Size ► High Rejection 0 Output Return Loss Input Return Loss Return Loss (dB) -5 -10 -15 -20 -25 -30 64 66 68 70 72 74 76 Frequency (MHz) SPECIFICATIONS Center Frequency 70 MHz Passband Loss 1.5 dB Passband 64.0 - 75.69 MHz 20 dB Bandwidth 49.0 - 91.69 MHz 40 dB Bandwidth 20.3 - 210 MHz Power Rating 1 Watt (Max.) Impedance 50 Ohms (Nom.) Operating Temperature Range -55 to +85 °C Package # 368 PORT CONFIGURATION Copyright © Synergy Microwave Corporation 201 McLean Boulevard • Paterson, New Jersey 07504 • Tel: (973) 881-8800 • Fax: (973) 881-8361 E-Mail: [email protected] • World Wide Web: http://www.synergymwave.com Input Output SMA M SMA F [ 1 of 3 ] BAND PASS FILTER CONNECTORIZED MODEL: TFIS-10.7 Fc = 70 MHz 0 -0.2 -0.4 -0.6 -0.8 -1 -1.2 -1.4 64 66 68 70 72 74 76 Frequency (MHz) Stopband Rejection (dB) 0 -5 -10 -15 -20 -25 -30 -35 -40 -45 -50 20 40 60 80 100 120 140 160 180 200 220 PERFORMANCE PLOTS Passband Insertion Loss (dB) OPTIMIZED BANDWIDTH Frequency (MHz) Copyright © Synergy Microwave Corporation 201 McLean Boulevard • Paterson, New Jersey 07504 • Tel: (973) 881-8800 • Fax: (973) 881-8361 E-Mail: [email protected] • World Wide Web: http://www.synergymwave.com [ 2 of 3 ] BAND PASS FILTER CONNECTORIZED MODEL: TFIS-10.7 Fc = 70 MHz 177 176 175 174 173 172 171 170 169 168 64 66 68 70 72 74 76 74 76 Passband Group Delay (nSec) Frequency (MHz) 40 35 30 25 20 15 10 5 0 64 66 68 70 72 PERFORMANCE PLOTS Passband Insertion Phase (deg.) OPTIMIZED BANDWIDTH Frequency (MHz) Copyright © Synergy Microwave Corporation 201 McLean Boulevard • Paterson, New Jersey 07504 • Tel: (973) 881-8800 • Fax: (973) 881-8361 E-Mail: [email protected] • World Wide Web: http://www.synergymwave.com [ 3 of 3 ]