band PASS filter surface mount MODEL: FNS-10.7 Fc = 10.7 MHz optimized bandwidth FEATURES: ► Low Loss ► Small Size ► High Rejection Passband Insertion Loss (dB) 0 -0.5 -1 10.2 10.4 10.6 10.8 11 11.2 F requency (MHz) SPECIFICATIONS ( Rev. B 08/05/09 ) Center Frequency 10.7 MHz Passband Frequency 10.2 - 11.2 MHz Insertion Loss 1.7 dB (Max.) 35 dB Bandwidth 5.1 - 22.5 MHz Power Rating 1 Watt (Max.) Impedance 50 Ohms (Nom.) VSWR (Passband) 1.5:1 Operating Temperature Range -20 to +70 °C Package # 124S PORT CONFIGURATION Copyright © Synergy Microwave Corporation 201 McLean Boulevard • Paterson, New Jersey 07504 • Tel: (973) 881-8800 • Fax: (973) 881-8361 E-Mail: [email protected] • World Wide Web: http://www.synergymwave.com Input Output Gnd. 1 16 All Other [ 1 of 3 ] band PASS filter surface mount MODEL: FNS-10.7 Fc = 10.7 MHz optimized bandwidth Passband Insertion Phase (deg.) 25 0 -25 -50 10.2 10.4 10.6 10.8 11 11.2 11 11.2 Frequency (MHz) -13.5 Return Loss (dB) -14 -14.5 -15 -15.5 -16 10.2 10.4 10.6 10.8 Frequency (MHz) PERFORMANCE PLOTS 50 Input Return Loss (dB) Output Return Loss (dB) Copyright © Synergy Microwave Corporation 201 McLean Boulevard • Paterson, New Jersey 07504 • Tel: (973) 881-8800 • Fax: (973) 881-8361 E-Mail: [email protected] • World Wide Web: http://www.synergymwave.com [ 2 of 3 ] band PASS filter surface mount MODEL: FNS-10.7 Fc = 10.7 MHz optimized bandwidth -10 Stopband Rejection (dB) -20 -30 -40 -50 -60 -70 -80 0.3 10.3 20.3 30.3 40.3 50.3 11 11.2 Frequency (MHz) 260 240 Group Delay (nSec) 220 200 180 160 140 120 PERFORMANCE PLOTS 0 100 10.2 10.4 10.6 10.8 Frequency (MHz) Copyright © Synergy Microwave Corporation 201 McLean Boulevard • Paterson, New Jersey 07504 • Tel: (973) 881-8800 • Fax: (973) 881-8361 E-Mail: [email protected] • World Wide Web: http://www.synergymwave.com [ 3 of 3 ]