DCBA 4 3 2 1 DCBA 4 3 2 1 Micro Data Center Layout

4
3
2
1
Micro Data Center Layout, Cable Management, Grounding/Bonding, Power and ID
Panduit Multimode Dielectric
Conduited Fiber (Uplink)
PANDUIT
WGSDWL
PANDUIT
WGSDWL
Panduit TM Wyr-grid TM
Light
Thermal
Blanking panels optimize
airflow and improve
appearance. Perforated
and solid blanking panels
shown.
PANDUIT
WGSDWL
Cable Management
1RU Fiber enclosure with
termination management,
bend radius control and
protection
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
13
13
14
14
15
15
16
16
17
17
18
18
19
19
20
20
21
21
22
22
23
23
24
24
25
25
26
26
27
27
28
28
29
29
30
30
31
31
32
32
33
33
34
34
35
35
36
36
37
37
38
38
39
39
40
40
41
41
42
42
43
43
44
44
45
45
46
46
47
47
48
48
11
22
33
44
55
66
77
88
99
10
10
11
11
12
12
13
13
14
14
15
15
16
16
17
17
18
18
19
19
20
20
21
21
22
22
23
23
24
24
25
25
26
26
27
27
28
28
29
29
30
30
31
31
32
32
33
33
34
34
35
35
36
36
37
37
38
38
39
39
40
40
41
41
42
42
43
43
44
44
45
45
46
46
47
47
48
48
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
13
13
14
14
15
15
16
16
17
17
18
18
19
19
20
20
21
21
22
22
23
23
24
24
25
25
26
26
27
27
28
28
29
29
30
30
31
31
32
32
33
33
34
34
35
35
36
36
37
37
38
38
39
39
40
40
41
41
42
42
43
43
44
44
45
45
46
46
47
47
48
48
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
CONSOLE
MODE
MODE
CONSOLE
FN
2X
2X
SYST
SYST
FN
1X
1X
Network Switch
1
1
2
2
1
1
2
2
3
3
4
4
5
5
CONSOLE
CONSOLE
MODE
MODE
SYST
SYST
FN
FN
XPS
XPS
S-PWR
S-PWR
6
6
STAT
STAT
MAST
MAST
7
7
XPS
XPS
S-PWR
S-PWR
8
8
SPEED
SPEED
STACK
STACK
9
9
STAT
STAT
MAST
MAST
DUPLX
DUPLX
11X 13X
11X 13X
10
10
SPEED
SPEED
STACK
STACK
11
11
12
12
4
4
5
5
SYST
SYST
FN
FN
6
6
7
7
XPS
XPS
S-PWR
S-PWR
8
8
9
9
STAT
STAT
MAST
MAST
10
10
SPEED
SPEED
STACK
STACK
11
11
12
12
15
15
16
16
17
17
18
18
19
19
20
20
21
21
22
22
23
23
24
24
14
14
15
15
16
16
17
17
18
18
19
19
20
20
21
21
22
22
23
23
24
24
2X
2X
2
2
3
3
4
4
5
5
CONSOLE
SYST
FN
6
6
7
7
8
8
9
9
10
10
XPS
STAT
SPEED
S-PWR
MAST
STACK
Panduit Multimode
Fiber Patch Cord
11
11
12
12
2X
2
1
3
4
2
5
6
3
7
8
9
4
26
26
27
27
28
28
29
29
30
30
31
31
32
32
33
33
34
34
35
35
36
36
25
25
26
26
27
27
28
28
29
29
30
30
31
31
32
32
33
33
34
34
35
35
36
36
36X 38X
36X 38X
37
37
38
38
39
39
40
40
41
41
42
42
43
43
44
45
46
47
48
44Catalyst
45 3750-X
46 Series
47
48
Catalyst 3750-X Series
G1
G1
37
37
38
38
39
39
40
40
41
41
42
42
43
43
44
45
46
47
48
44Catalyst
45 3750-X
46 Series
47
48
Catalyst 3750-X Series
G1
G1
35X 37X
35X 37X
C3KX-NM-10G
C3KX-NM-10G
NETWORK
BLANK
MODULE
NETWORK
MODULE
BLANK
MODULE
MODULE
G2/TE1
G2/TE1
G4/TE2
G4/TE2
G3
G3
C3KX-NM-10G
C3KX-NM-10G
NETWORK
BLANK
NETWORK
BLANK
MODULE
MODULE
MODULE
MODULE
G2/TE1
G2/TE1
G4/TE2
G4/TE2
36X 38X
36X 38X
23X 25X
23X 25X
35X 37X
35X 37X
G3
G3
24X 26X
24X 26X
13
13
14
14
15
15
16
16
17
17
18
18
19
19
20
20
21
21
22
22
23
23
24
24
C3KX-NM-10G
C3KX-NM-10G
NETWORK
BLANK
NETWORK
BLANK
MODULE
MODULE
MODULE
MODULE
G2/TE1
G2/TE1
G4/TE2
G4/TE2
36X 38X
36X 38X
25
25
26
26
27
27
28
28
29
29
30
30
31
31
32
32
33
33
34
34
35
35
36
36
37
37
38
38
39
39
40
40
41
41
42
42
43
43
44
45
46
47
48
44Catalyst
45 3750-X
46 Series
47
48
Catalyst 3750-X Series
G1
G1
G3
G3
DUPLX
1X
1
35X 37X
35X 37X
25
25
24X 26X
24X 26X
12X 14X
12X 14X
1
1
24X 26X
24X 26X
23X 25X
23X 25X
DUPLX
DUPLX
11X 13X
11X 13X
MODE
10
11
5
11X
13X
12X
14X
12
23X 25X
24X 26X
13
14
6
15
16
17
7
18
19
20
8
21
22
23
9
NETWORK
BLANK
MODULE
MODULE
G2/TE1
G4/TE2
Cable Management
Standard patching using a 24 Port
Patch Panel with D-Ring (open) or
(hidden)
Horizontal
NetManagerTM
(hidden)
Horizontal
Manager
36X 38X
24
10
C3KX-NM-10G
35X 37X
25
11
26
27
12
28
29
30
31
32
13
33
34
14
35
36
15
37
38
16
39
40
17
41
42
43
44
45
46
47
Catalyst 3750-X Series
18
19
48
G1
20
21
22
G3
23
24
24
#
#
#
#
Inside
Cabinet
14
14
13
13
12X 14X
12X 14X
3
3
CONSOLE
CONSOLE
1X
1X
Layout
Switches turned around to have
ports on same side
23X 25X
23X 25X
13
13
11X 13X
11X 13X
2X
2X
1
12X 14X
12X 14X
DUPLX
DUPLX
1X
1X
MODE
MODE
#
#
#
Identification
Label cords with FROM and TO
location. Panduit TurnTell
labels makes it easy to view
3
3
2
2
1
2
3
4
5
1
0
1
1
1 X4
2
A
0 X4
1 GbEiSCSI TOE
3
4
5
0 X4
1
3
PCI
PCI
2
1 X4
6Gb SAS
5
2
2
6Gb SAS
0
4
0 X4
4
1
3
PCI
PCI
2
4
1
3
ATTENTION
Power supply filler is
required for system cooling
Remove only when
installing 2nd power supply
AC
DC
ATTENTION
Power supply filler is
required for system cooling
Remove only when
installing 2nd power supply
AC
PCI
2
1
PCI
2
PCI
DC
4
3
PCI
ATTENTION
Power supply filler is
required for system cooling
Remove only when
installing 2nd power supply
AC
DC
4
1
3
PCI
PCI
2
4
1
3
ATTENTION
Power supply filler is
required for system cooling
Remove only when
installing 2nd power supply
AC
DC
PCI
2
Servers
3
0
5
0 X4
1 GbEiSCSI TOE
Strain Relief
Strain Relief Bar and
Clip securely hold
horizontal cable
preventing disconnect
1
0
3
3
4
0
B
2
A
1 GbEiSCSI TOE
3
1
1 X4
2
2
1 X4
6Gb SAS
2
1 GbEiSCSI TOE
6Gb SAS
0
1
0
B
PCI
ATTENTION
Power supply filler is
required for system cooling
Remove only when
installing 2nd power supply
AC
DC
4
1
3
PCI
PCI
2
4
ATTENTION
Power supply filler is
required for system cooling
Remove only when
installing 2nd power supply
AC
DC
1
3
PCI
PCI
2
4
ATTENTION
Power supply filler is
required for system cooling
Remove only when
installing 2nd power supply
AC
DC
UPS
UPS
ATTENTION
Power supply filler is
required for system cooling
Remove only when
installing 2nd power supply
AC
DC
B
Heavy
Uninterruptible
Power Supply
Front View
A
Rear View
Power
Verticle Power Outlet Unit (POU)
powers devices. Some units have
power and environmental monitoring
and connected to UPS. A second POU
can be added for redundant power.
Grounding/Bonding
Grounding cable attach to grounding
bar. Jumpers attach to ground bar
and equipment
Use this drawing when:
 Deploying a new compute, network, and/or
storage cabinet or Rack
 Upgrading or adding devices
 Expanding the network
 Addressing Move, Add and Changes
maintenance issues
B
A
Micro Data Center
Reference Design
Y-PCD0007-05AUG2014--ENG.pdf
4
C
3
2
3
3
#
Storage Array
D
PANDUIT
WGSDWL
Cable Management
High Density patching using a 48 Port
Angled Patch Panel. Horizontal
managers not needed.
1 RU Space
for Fiber Shelf
Panduit Small
Diameter Patch Cord
C
To Factory Integrated Network
Zone Systems or Switches
PANDUIT
WGSDWL
PANDUIT
WGSDWL
2
PANDUIT
WGSDWL
1
PANDUIT
WGSDWL
0
D
Panduit CAT 6 Industrial
Cable
3
To Enterprise
3
2
1
Bill of Material
Panduit Part Number
Description
42RU Pre-Configured Industrial Micro Data Center, 78.1"
CQSMDC79
(1984mm) height, network cabling, 4 casters, and shock
pallet.
Net-Access S-Type Cabinet frame. Single hinge perforated
S8222B
CPPA48FMWBLY
CPPL24M6BLY
front door. Split perforated rear doors. Dim 79.8"H x
31.5"W x 48.0"D
Angled 48-port flush mount patch panel supplied with rear
mounted faceplates
24-port patch panel supplied with four factory installed
CJ688TGBL
CFPLM6BL snap-in faceplates.
Cat 6, 8 position, 8 wire universal module.
CMPHF1
D-rings installed on panel
NMF1
Horizontal Cable Manager High Capacity Front Only 1RU
TLBP1R-V
Tool-less Blanking Panel for 1RU
UTP28SP5GR
F52ERLNLNSNM001
FAP6WBLDLC
FCE1U
CMRPSV20
Cat 6 Performance, 28 AWG UTP patch cord with TX6
Modular Plugs on each end Green 5 ft
or FOSM splice modules
Power Strip Vertical, 20A, 10 NEMA 5-20R Receptacles,
NEMA 5-20P
Grounding Busbar Kit, 19" length, 20 holes
RGCBNJ660P22
#6 AWG jumper; 60" length; 45° bent lug
SRBBRWC-KIT
IUC6C04ABL-CEG
FSPD508-050M
WG12BL10
Server, Switch, Storage, etc. Layout
For best stability, heavier equipment like server, UPS and storage should be
mounted towards the bottom of a cabinet or rack with lighter components
like switch, firewall and patch panel towards the top. Reliable and efficient
cabling is best with all equipment ports facing backwards. Equipment like
switches may need to be turned around with their port side facing
backwards. Cabinet rails may need to be moved forward to line up devices
on the front. Ensure cabinet or rack RU holes are compatible with
equipment rails and brackets.
Cable Management
Follow best practices to route and protect cabling to achieve the highest
reliability and ease Moves, Adds, and Changes. Reduce interference with
ports by placing rack mounted horizontal cable managers like D-Rings and
NetManagers above and below equipment or flat patch panels to route
cables away from port. Use angled patch panels for high density patching.
A fiber enclosure protects exposed fiber cable, termination management
(e.g. fusion splice), and bend radius control. Select patch cord lengths that
have minimal slack between connections. Use slack spools to take up slack.
Bundle cables using Hook & Loop cable ties for easy cable additions and
removal. Horizontal cable should have strain relief to prevent jack
connection damage like a strain relief bar.
OM2 2-fiber patch cord, riser rated, LC duplex to LC duplex Grounding & Bonding
Grounding and bonding is essential for reliable communication and equipment
with 1.6mm jacket 1M
protection. A solid copper grounding conductor is terminated to a lug and
LC OM2 FAP loaded with six LC duplex multimode fiber optic then landed on a grounding bar. Jumper cables are attached to equipment
adapters (Black) with phosphor bronze split sleeves.
ground terminal and then routed to the grounding bar terminated with a lug
that is attached to the grounding bar with a screw.
Holds up to four QuickNet Cassettes, FAP adapter panels,
RGRB19CN
R100X150V1T
About this Configuration
TurnTellThermal Transfer, Vinyl, 1.00" W x 1.50" H, 0.50"
Power
Reliable power is achieved with redundant power sources via UPS or dual,
independent power lines to a Power Outlet Unit (POU). The POU should
have a current rating and outlets sized to support current and future
equipment. POUs can also come with power and environmental monitoring to
provide critical alerts.
Identification
Clear and intuitive identification eases installation along with Move, Adds
and Changes. This includes labeling cables on both ends following TIA-606B standards. Color coding such as cables, color bands, and labels can be
Strain relief bar with integrated adjustable clips and pair of
used to identify VLANs, areas, media type.
quick release brackets.
POA, Clear/White, 3" Core
Industrial Copper Cable, Cat 6, 4-pair, 24/7 AWG stranded,
U/UTP, CM, Black, 1000FT/305m reel
8-fiber OM2 dielectric conduited, Low smoke zero halogen
(LSZH)-riser (OFNR) rated, (MM) indoor distr cable 50M
12" Wide Wyr-Grid Straight Section
For More Information
For more information, contact your local distributor, Panduit Sales rep
or Rockwell Automation sales rep.
www.panduit.com/ia
[email protected]