Popular Configuration Drawing - Industrial Switch Deployment

4
3
2
1
A typical industrial network deployment encompasses Panduit 5 “IN” solutions.
A Stratix switch can be deployed in a Micro Data Center, Zone Enclosure,
Industrial Distribution Frame, Control Panel or On Machine
D
IN-ROOMTM
IN-ROUTETM
IN-PANELTM
IN-FIELDTM
Panduit J-Pro
Panduit Wyr-Grid
Panduit Dielectric
Conduited Fiber
(DCF)
To Enterprise
PANDUIT
WGSDWL
PANDUIT
WGSDWL
VPN
FLASH
ACTIVE
STATUS
POWER
VPN
FLASH
RESET
CISCO ASA 5510 SERIES
1
1
2
5
1400W AC
PCIe
slots
10GE
10GE
1GE
1GE
2
1
4
1400W AC

M
2
1
1
2
3
24
24
23
22
21
23
22
21
20
18
18
16
17
19
20
3 4
+ SEN
5 6 7
+ OUT GND
PWR
1
NET
CHG
0
UPS
CON
8
9
10
5 6 7
+ OUT GND
PWR
1
MOD
NET
CHG
0
UPS
Maintenance-free No battery 24VDC
CON
8
9
10
Panduit Polymer
Coated Fiber (PCF)
Panduit
Cat 5e
Industrial
Copper Cable
Panduit PCF LC
duplex field term
Panduit PanelMax
DIN Rail Duct
13
14
24
2
14
1
23
24
13
23
SPEED
STACK
2
STAT
MAST
12
12
XPS
S-PWR
1
SYST
FN
11
CONSOLE
DUPLX
BLANK
MODULE
Catalyst 3750-X Series
MODE
CONSOLE
SYST
FN
XPS
STAT
SPEED
S-PWR
MAST
STACK
Catalyst 3750-X Series
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
11
12
DUPLX
BLANK
MODULE
Catalyst 3750-X Series
MODE
9
10
Catalyst 3750-X Series
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
11
42
43
12
44
45
46
47
Catalyst 2960-S Series
48
CONSOLE
SYST
RPS
MSTR
STAT
DPLX
SPED
STCK
PoE
1X
11X
13X
23X
25X
35X
37X
47X
2X
12X
14X
24X
26X
36X
38X
48X
MODE
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
M
G
M
T
B
A
S
E
T
49
50
51
52
1X
11X
13X
23X
25X
35X
37X
47X
2X
12X
14X
24X
26X
36X
38X
48X
MODE
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
M
G
M
T
B
A
S
E
T
49
50
51
52
Catalyst 2960-S Series
48
CONSOLE
SYST
RPS
MSTR
STAT
DPLX
SPED
STCK
PoE
1X
11X
13X
23X
25X
35X
37X
47X
2X
12X
14X
24X
26X
36X
38X
48X
MODE
UPS
1 0 0 0
M
G
M
T
B
A
S
E
T
49
Smart-UPS
Panduit Cat 6 Industrial Copper Downlinks to
machines, control panels and end devices
Catalyst 2960-S Series
48
CONSOLE
SYST
RPS
MSTR
STAT
DPLX
SPED
STCK
PoE
Panduit Integrated
Network Zone Systems
(Layer 2)
50
51
52
Fiber
Links
Use this drawing when:
 Beginning a new network design
 Upgrading network
 Need to improve reliability and
performance
I
Test
O
www.apcc.com
Overview Drawing of Industrial
Switch Deployment
Y-PCD0001-01MAY2015--ENG.PDF
3
3 4
+ SEN
C
B
11
Zoned Network Architecture
 Building block approach for network distribution
 Based on Rockwell Automation/Cisco** Converged
PlantWide Ethernet (CPwE)
 Reduces cable home runs back to TR or Data Center
reducing cable sprawl
 Improved scalability and future ready
Panduit M12
Decode
Connector &
Adapter
Panduit PanelMax
Noise shield
1 2
+ INP
Panduit Cat 5e 600V
Rated Cable
Panduit No
Battery UPS
A Panduit Pre-configured
Industrial Distribution
Frame for 19" Rack
switches ready for 2 access
and 2 distribution switches.
Panduit DIN bracket can
accommodate DIN
Switches. See PCD0010
for more details.
* Stratix 8003, Stratix 8000, and Stratix 5700 are trademarks
of Rockwell Automation, Inc.
** Cisco is a registered trademark of Cisco Technology Inc.
17
19
1 2
+ INP
MOD
Maintenance-free No battery 24VDC
Ground Cable Connected
to Grounding Bar
IN-FRASTRUCTURE
4
16
ACT
ACT
3
5
PCIe
slots
15
SPD
SPD
1400W AC
15
ACT
ACT
1400W AC
14
SPD
SPD
4
14
ACT
3
4
13
SPD
1
2
3
13
ACT
PSU
1
2
12
SPD
1
TM
A
ACTIVE
POWER
SPD
0
STATUS
AUX
SPD LNK
1
100-240V ~ 2.5A – 50-60Hz
SPD LNK
2
100-240V ~ 2.5A – 50-60Hz
USB2 USB1
SPD LNK
3
A Panduit preconfigured
Micro Data Center
solution that houses
Compute, Network and
Storage devices
dedicated to
manufacturing. Home
for PlantPAx and
FactoryTalk suites. A
Panduit DIN bracket can
accommodate layer 3
Stratix 5400 OR 8300*.
See PCD007 for more
details
RESET
CONSOLE
MGMT
LNK
1
12
P0
CISCO ASA 5510 SERIES
FLASH
11
0
SPD
AUX
SPD
0
11
1
LNK
USB2 USB1
SPD LNK
1
10
P0
SPD
2
CONSOLE
SPD LNK
2
10
0
LNK
3
MGMT
SPD LNK
3
Panduit control panel
solutions facilitate
installation of a
Stratix 8000* or
5700* switch by
managing cables,
mitigating noise, and
optimizing space. See
PCD0004 for more
details
9
SPD
FLASH
LNK
A Panduit Integrated
Network Zone System
is a NEMA4/4X and
IP66 rated preassembled enclosure
with a Stratix 8000*
or 5700*switch along
with power and UPS.
It is a building block
for Zone architecture
that is fully validated
and tested.
9
SPD
LNK
4
24
24
8
2
LNK
5
23
23
8
SPD
22
22
7
SPD
LNK
21
21
7
HD1
CONSOLE
ACT
ACTIVE
4
LNK
7
SPD
20
20
6
SPD
LNK
19
19
6
ACT
100
100
LNK
18
18
5
LNK
MGMT
LNK
6
SPD
17
17
5
ACTIVE
BOOT
SPD
ALARM
ACT
POWER
SPD
VPN
HD1
ACT
HD0
CONSOLE
SPD
SPD
ALARM
1
4
100
100
ACT
ACT
BOOT
16
16
3
SPD
POWER
15
15
5
SPD
VPN
14
14
6
SPD
HD0
13
13
7
4
12
12
3
11
11
3
10
10
(in conduit)
2
9
9
A Panduit Integrated
Network Zone
system mounted on a
Machine optimized
for a Stratix 5700*.
See PCD0002 and
PCD0006 for more
details
Panduit Polymer Coated Fiber (PCF)
2
8
8
C
B
PANDUIT
WGSDWL
1
7
7
I
6
6
O
5
5
I
4
4
O
3
3
MGMT
2
2
100-120V~, 5A MAX, 50Hz
200-240V~, 2.5A MAX, 60Hz
1
1
100-120V~, 5A MAX, 50Hz
200-240V~, 2.5A MAX, 60Hz
Panduit Opticam® OM3/
OM4 LC Connector
PANDUIT
WGSDWL
Panduit Interlocking
Armored Fiber
1
PANDUIT
WGSDWL
Panduit Opti-Core® OM3
Distribution Cable
D
2
1
A
Bill of Material
Part Number
Description
Micro Data Centers
CQSMDC79
CQSMDC48
IABDIN4
48 RU Pre-Configured Industrial Micro Data Center, 78.1''
(1984mm) height, network cabling, 4 casters, and shock pallet
24 RU Pre-Configured Industrial Micro Data Center, 48.4''
(1239mm) height, network cabling, 4 casters, and shock pallet
IA Bracket for 19'' wide rack or cabinet. Installs DIN rail
mountable equipment. 4 RU high
Integrated Network Zone System and Industrial Distribution Frame
Z23N-SBABD5
Z22N-SDAD5
Z11N-SDD
ZDF48-RA
24"x36" Integrated Zone Enclosure with 16 downlinks,
expandable up to 48, Stratix 8000, and UPS
24"x24" IZE with Stratix 5700, 8 downlinks, and UPS
12"x14" IZE with Stratix 5700 and 8 downlinks
Pre-Config wall/column mount Industrial Distribution Frame
enclosure ready for 2 access and 2 distribution siwtches
Control Panel
UPS003024024015
SD3EMI
DRD33LG6
FODRX12Y
FI2D204
FLCDHMIG
FSPD512
FOPRX12Y
FLCDMCXAQY
PUR6004BU-UY
IUC6CO4ABL-CEG
ISPS688FA
ISFCH5C02ARD-XG
ICAM12DRJS
ISPS5E44MFA
ISTPHCH1MBL
JP2SBC50-L20
Uniterruptible Power Supply (UPS), 35 Watts for 5 minutes,
24VDC in/out, DIN rail mount.
EMI noise shield kit for 3'' height Panduit wiring duct
3'' height PanelMax DIN Rail Wiring Duct
Cabling, Connectgor and Pathways
12-fiber MM OM3, 10 GbE, riser rated distribution cable
4-fiber MM OM2, Polymer Coated Fiber (PCF), LSZH, riser
indoor Break-out
PCF LC duplex crimp fiber optic connector, OM1/OM2
12-fiber OM2 dielectric (MM) armored distribution cable
12-fiber OM3 (MM) interlocking riser rated armored cable
LC OM3/OM4 multimode duplex connector for 900µm
Cat 6, solid copper, 4-pair, UTP, CMR Riser, PVC Jacket
Cat 6, industrial copper stranded, 4-pair, U/UTP
Cat 6A, industrial field term, RJ45 plug
Cat 5e, industrial copper stranded, 2-pair, SF/UTP, CM, 600V,
Industrial Panel Mount M12 D-Code Female to RJ45 Adapter
Industrial Field Attachable M12 D-Code Male Plug
600 volt rated, Cat 5e patch cord, 1 meter
J-Hook with screw-on beam clamp
For More Information
For more information, contact your local distributor, Panduit Sales rep
or Rockwell Automation sales rep.
www.panduit.com/ia
[email protected]
About this Configuration
Panduit has the complete end-to-end products and solutions to deploy
a robust, secure and future ready industrial network. The 5 IN’s
group Panduit products, addressing the different aspects of a
network deployment.
IN-ROOM (Micro Data Center)
The Micro Data Center (MDC) is the hub of a network deployment
containing servers, switches, and other active gear
- Preconfigured Micro Data Center Cabinet with cabling
- Different size network/server racks and cabinets
- Patching and cable Management
- Network physical security
- Identification and color code
- Grounding and Power
IN-ROUTE
Solutions and products to connect MDC, switches, controllers and
other active gear
- Integrated Network Zone System including switch
- Pre-configured Industrial Distribution Frame (IDF)
- Industrial Pathways like J-Hooks and Wyr-Grid
- Full line of industrial copper and fiber cable
IN-PANEL
A full set of products to accommodate any panel design for both
new and retrofits especially sensitive network cabling
- Cable Management/Protection
- Connectors and Terminals
- EMI Protection
- Space Optimization
- Networking
- Labeling
IN-FIELD
Products to manage cabling in a harsh environment
- Integrated Network Zone System
- Harsh cable protection/bundling
- Harsh connectors/Terminals
- Safety/Identification
IN-FRASTRUCTURE
Products to distribute power and grounding including safety and
identification
- Power terminals
- Ground distribution
- LOTO/Labeling