SKY65146: 3.5 V Broadband MCM Power

DATA SHEET
SKY65146: 3.5 V Broadband MCM Power Amplifier
806–849 MHz
Functional Block Diagram
Applications
●
●
●
●
●
iDEN® (806–825 MHz)
TETRA (806–825 MHz)
TDMA (824–849 MHz)
AMPS (824–849 MHz)
Wireless Local Loop (WLL)
CMOS
Controller
50 Ω
Features
●
●
●
●
●
●
●
●
●
●
Low voltage positive bias supply (3.5 V)
High gain 39 dB, high power: PSAT 35.6 dBm
High efficiency: PAE 51%
Good linearity
Dual mode operation
Large dynamic range
28-pin LCC package (10 x 13.97 x 1.45 mm)
Power down control
Available on tape and reel
Available lead (Pb)-free and RoHS-compliant
50 Ω
Block Diagram
VD4
(28)
VREG
(1)
RF IN
(5)
VD2
(22)
VD3
(8)
CMOS
CONTROLLER
CIRCUIT
INPUT
MATCH
PA 1
GaAs HBT IC
INTER
STAGE
MATCH 1
PA 2
INTER
STAGE
MATCH 2
OUTPUT
MATCH
RF OUT
(15)
OUTPUT
STAGE
MODULE
Description
The SKY65146 is a fully matched 28-pin surface mount multi-chip
module (MCM) amplifier designed for Private Mobile Radio,
Wireless Local Loop, and TDMA/AMPS mobile units operating in the
806-849 MHz cellular bandwidth. Microwave Monolithic Integrated
Circuits (MMICs), comprised of Gallium Arsenide (GaAs) and
Si CMOS, contain all active circuitry in the module, which includes
on-board bias circuitry as well as input and interstage matching
circuits. The input and output match is realized off-chip within the
module package to optimize efficiency and high power performance (P3 dB_SAT ≅ 35.6 dBm) into a 50 Ω load.
Primary bias to the SKY65146 can be supplied directly from a
single cell lithium-ion or other suitable battery with a nominal
output of 3.5 V.
No external supply side switch is needed as typical “off” leakage
is a few microamperes with full primary voltage supplied from
the battery.
The ICs are manufactured on an advanced InGaP HBT process and
on a silicon CMOS process, providing for all positive voltage DC
supply operation while maintaining high efficiency and good linearity.
The module can operate over the temperature range of -40 ˚C to
85 ˚C. A populated evaluation board is available upon request.
NEW
Skyworks offers lead (Pb)-free, RoHS (Restriction of
Hazardous Substances)-compliant packaging.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
200810 Rev. A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • January 25, 2008
1
DATA SHEET • SKY65146
Electrical Specifications
VCC (VD) = 3.5 V, VREG = 2.75 V, Frequency = 815 MHz, TC = 25 °C, unless otherwise specified.
Parameter
Gain
Power gain
Input return loss
Saturated output power
Power added efficiency
Current @ PSAT
Symbol
lS21l
Small signal
Gp
PO = 29 dBm
35.5
38.7
lS11l
Small signal
12
17
dB
35.1
35.6
dBm
47
51
%
2
A
P3 dB SAT
Condition
PAE
PO = P3 dB SAT
PO = P3 dB SAT
Quiescent current
ICC
No RF signal
Harmonic Levels
2FO
3FO
4FO
PO < P3 dB SAT
PO < P3 dB SAT
PO < P3 dB SAT
Noise power in Rx band
FC + 30 MHz, BW = 18 kHz
RxBN
Typ.
270
329
NF
CW
Stability (spurious output)
S
Output VSWR = 10:1
Ruggedness - no damage
Ru
PO < 29 dBm
Unit
dB
40
370
-37
-60
-80
PO < 29 dBm
Noise figure
Max.
38.7
Gain Comp < 3 dB
ICC SAT
Min.
dB
mA
dBc
dBc
dBc
-85
dBm/Hz
8
dB
-36
dBm
6.8
15:1
VSWR
Recommended Operating Conditions
Parameter
Supply voltage
Regulation voltage
Operating frequency
Continuous RMS output power
Operating temperature
Symbol
VCC
Conditions
Min.
Typ.
Max.
Unit
3
3.5
4.4
V
VREG
2.65
2.75
2.85
V
FO
806
815.5
825
MHz
29
31
dBm
+25
+85
°C
PoRMS
TC
-40
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
2
January 25, 2008 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • 200810 Rev. A
DATA SHEET • SKY65146
Typical Performance Data
VCC (VD) = 3.5 V, VREG = 2.75 V, Frequency = 815 MHz, TC = 25 °C, unless otherwise specified.
-40 °C
25 °C
85 °C
3.0 V
42
-3.5 V
4.0 V
4.5 V
42
40
Gain (dB)
Gain (dB)
40
38
38
36
34
36
805
810
815
820
825
-15
10
35
60
85
Frequency (MHz)
Temperature (°C )
Gain vs. Frequency Across Temperature
Gain vs. Temperature Across Voltage
-40 °C
25 °C
85 °C
806 MHz
43
815.5 MHz
825 MHz
41
41
39
Gain (dB)
Gain (dB)
-40
39
37
37
35
35
33
33
25
27
29
31
33
35
37
22
25
28
31
34
37
POUT (dBm)
POUT (dBm)
Gain vs. POUT Across Temperature
Gain vs. POUT Across Frequency
3.0 V
-3.5 V
4.0 V
-40 °C
4.5 V
25 °C
85 °C
-15
42
-16
lS11l (dB)
Gain (dB)
39
36
33
-17
-18
-19
30
23
26
29
32
35
-20
805
810
815
820
825
POUT (dBm)
Frequency (MHz)
Gain vs. POUT Across VCC
lS11l vs. Frequency Across Temperature
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
200810 Rev. A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • January 25, 2008
3
DATA SHEET • SKY65146
Typical Performance Data
VCC (VD) = 3.5 V, VREG = 2.75 V, Frequency = 815 MHz, TC = 25 °C, unless otherwise specified.
-40 °C
25 °C
85 °C
806 MHz
2.4
815.5 MHz
825 MHz
2.3
1.9
ICC (A)
ICC (A)
1.7
1.4
1.1
0.9
0.4
0.5
21
24
27
30
33
36
22
25
28
31
34
POUT (dBm)
POUT (dBm)
ICC vs. POUT Across Temperature
ICC vs. POUT Across Frequency
3.0 V
3.5 V
4.5 V
4.0 V
3.0 V
2.5
3.5 V
37
4.5 V
4.0 V
0.43
2.0
IQ (A)
ICC (A)
0.38
1.5
0.33
1.0
0.5
23
26
29
32
35
0.28
38
-40
-15
10
35
60
POUT (dBm)
Temperature (°C)
ICC vs. POUT Across VCC
IQ vs. Temperature Across Voltage
-40 °C
25 °C
3.0 V
85 °C
8
7
7
3.5 V
4.5 V
4.0 V
NF (dB)
NF (dB)
8
6
5
6
805
810
815
820
825
5
-40
-15
10
35
60
Frequency (MHz)
Temperature (°C)
NF vs. Frequency Across Temperature
NF vs. Temperature Across Voltage
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
4
85
January 25, 2008 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • 200810 Rev. A
85
DATA SHEET • SKY65146
Typical Performance Data
VCC (VD) = 3.5 V, VREG = 2.75 V, Frequency = 815 MHz, TC = 25 °C, unless otherwise specified.
815.5 MHz
825 MHz
-40 °C
58
47
48
38
38
PAE (%)
PAE (%)
806 MHz
56
29
22
25
28
28
31
34
8
37
21
25
29
33
37
POUT (dBm)
POUT (dBm)
PAE vs. POUT Across Frequency
PAE vs. POUT Across Temperature
3.0 V
3.5 V
-10 dBm
-8.5 dBm
4.5 V
4.0 V
56
44
44
42
2nd Harmonics (dB)
PAE (%)
85 °C
18
20
11
25 °C
32
20
-9.5 dBm
-8 dBm
-9 dBm
40
38
36
8
23
26
29
32
35
34
38
-15
10
35
60
85
Temperature (°C)
PAE vs. POUT Across VCC
2nd Harmonics vs. Temperature Across PIN
-10 dBm
-8.5 dBm
-9.5 dBm
-8 dBm
-9 dBm
-10 dBm
-8.5 dBm
52
-9.5 dBm
-8 dBm
-9 dBm
44
2nd Harmonics (dB)
49
2nd Harmonics (dB)
-40
POUT (dBm)
46
43
40
42
40
38
36
37
34
3.00
3.25
3.50
3.75
4.00
4.25
4.50
34
805
810
815
820
825
Voltage (V)
Frequency (MHz)
2nd Harmonics vs. Voltage Across PIN
2nd Harmonics vs. Frequency Across PIN
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
200810 Rev. A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • January 25, 2008
5
DATA SHEET • SKY65146
Typical Performance Data
VCC (VD) = 3.5 V, VREG = 2.75 V, Frequency = 815 MHz, TC = 25 °C, unless otherwise specified.
-10 dBm
-8.5 dBm
-9.5 dBm
-8 dBm
-9 dBm
-10 dBm
-8.5 dBm
-9 dBm
61
61
60
3rd Harmonics (dB)
3rd Harmonics (dB)
-9.5 dBm
-8 dBm
59
58
60
59
58
57
56
-40
-15
10
35
60
57
805
85
820
825
Frequency (MHz)
3rd Harmonics vs. Temperature Across PIN
3rd Harmonics vs. Frequency Across PIN
-9.5 dBm
-8 dBm
-10 dBm
-8.5 dBm
-9 dBm
62
-9.5 dBm
-8 dBm
-9 dBm
84
82
61
4th Harmonics (dB)
3rd Harmonics (dB)
815
Temperature ( C )
-10 dBm
-8.5 dBm
60
59
80
78
76
58
3.00
3.25
3.50
3.75
4.00
4.25
74
-40
4.50
-15
10
35
60
Temperature (°C)
3rd Harmonics vs. Voltage Across PIN
4th Harmonics vs. Temperature Across PIN
-9.5 dBm
-8 dBm
-9 dBm
-10 dBm
-8.5 dBm
-9.5 dBm
-8 dBm
-9 dBm
82
83
4th Harmonics (dB)
81
79
77
75
805
810
815
820
825
80
78
76
3.00
3.25
3.50
3.75
4.00
4.25
4.50
Frequency (MHz)
Voltage (V)
4th Harmonics vs. Frequency Across PIN
4th Harmonics vs. Voltage Across PIN
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
6
85
Voltage (V)
-10 dBm
-8.5 dBm
4th Harmonics (dB)
810
January 25, 2008 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • 200810 Rev. A
DATA SHEET • SKY65146
Application Circuit Notes
Package and Handling Information
Center Ground. It is extremely important that the device paddle
be sufficiently grounded for both thermal and stability reasons.
Multiple small vias are acceptable and will work well under the
device if solder migration is an issue.
Since the device package is sensitive to moisture absorption, it is
baked and vacuum packed before shipping. Instructions on the
shipping container label regarding exposure to moisture after the
container seal is broken must be followed. Otherwise, problems
related to moisture absorption may occur when the part is subjected to high temperature during solder assembly.
VD2 (Pin 1). Supply voltage for output (final) stage collector bias
(typically 3.5 V). Bypassing of VD3 is accomplished with C2 and
C3 and should be placed in the approximate location shown on
the Evaluation Board, but placement is not critical.
Please refer to Skyworks’ solder reflow application note, available
at www.skyworksinc.com, for instructions on mounting the
SKY65146 to a printed circuit board.
Ground (Pins 2, 3, 6, 11, 13, 16, 19, 20, 23–28).
Attach all ground pins to the RF ground plane with the largest
diameter and lowest inductance via that the layout will allow.
Multiple small vias are also acceptable and will work well under
the device if solder migration is an issue.
Production quantities of this product are shipped in a standard
tape and reel format. For packaging details, refer to the Skyworks
Application Note, Tape and Reel, document number 101568.
No Connect (Pins 4, 5, 9, 10, 14, 17, 18, 21). The pins are open
and may or may not be connected to ground.
Electrostatic Discharge (ESD) Sensitivity
The SKY65146 is a static-sensitive electronic device. Do not
operate or store near strong electrostatic fields. Take proper ESD
precautions.
VD4 (Pin 7). Supply voltage for base bias circuitry to all stages
(typically 3.5 V). Bypassing of VD3 is accomplished with C1 which
should be placed in the approximate location shown on the
Evaluation Board, but placement is not critical.
Theory of Operation
VREG (Pin 8). VREG is the regulated bias enable control voltage to
the silicon CMOS controller, 0.0 V = Off, 2.75 V = On. Nominal
“On” operating range is between 2.65 VDC and 2.85 VDC. VREG set
to 0 VDC will force the amplifier into standby mode.
The SKY65146 is a fully matched 3-stage GaAs HBT power
amplifier module consisting of on-chip interstage matching circuits and bias circuitry. The input and output match is realized
off-chip, but within the module package. The amplifier employs
series feedback on the first and second stages to provide for high
gain and stability and power of up to 4 W.
RF_IN (Pin 12). Amplifier RF Input Pin. ZO = 50 Ω. The module
includes an onboard internal DC blocking capacitor. All impedance matching is provided internal to the module.
The module includes a silicon CMOS controller circuit to provide
a regulated bias enable control, VREG (0–2.75 V) for amplifier
On/Off operation. In off operation, supply current is a few
microamperes with VREG = 0 V. The module operates with all
positive DC voltages while maintaining high efficiency and good
linearity. The nominal operating voltage is 3.5 V for maximum
power, but can be operated at slightly lower voltages for other
mobile applications.
VD3 (Pin 15). Supply voltage for driver collector bias (typically
3.5V). Bypassing of VD3 is accomplished with C4 and C5 which
should be placed in the approximate location shown on the
Evaluation Board, but placement is not critical.
RF_OUT (Pin 22). Amplifier RF Output Pin. ZO = 50 Ω. The
module includes an onboard internal DC blocking capacitor. All
impedance matching is provided internally to the module.
Application Circuit
VD2
C3
1000 pF
C2
10 F
VD4
C1
10 F
7
6
NC
5
NC
4
3
2
1
8
VREG
28
NC 9
27
NC 10
26
SKY65146
11
RF_IN
50 Ω
25
12
24
13
23
22
NC 14
15
VD3
C4
10 F
16
17
NC
18
NC
19
20
21
NC
50 Ω
RF_OUT
C5
1000 pF
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
200810 Rev. A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • January 25, 2008
7
DATA SHEET • SKY65146
Pin Assignments
NC
NC
GND
GND
VD2
VD2
Description
Supply voltage for output (final) stage collector
bias (typically 3.5 V)
GND
1
Pin Name
VD4
Pin
Pin Out
7
6
5
4
3
2
1
VREG 8
28 GND
27 GND
2
GND
Low inductance ground connection
NC 9
3
GND
Low inductance ground connection
NC 10
26 GND
25 GND
4
N/C
No connect
GND 11
5
N/C
No connect
RFIN 12
24 GND
6
GND
Low inductance ground connection
GND 13
23 GND
NC 14
22 RFOUT
N/C
No connect
10
N/C
No connect
11
GND
Low inductance ground connection
12
RFIN
806–928 MHz RF input signal 50 Ω
RF input power
11 dBm
Supply voltage (VCC & VREF)
6.9 V(1)
Supply voltage (VCC & VREF)
VCC V (2)
13
GND
Low inductance ground connection
14
N/C
No connect
15
VD3
Supply voltage for driver collector bias
(typically 3.5 V)
16
GND
Low inductance ground connection
17
N/C
No connect
18
N/C
No connect
19
GND
Low inductance ground connection
20
GND
Low inductance ground connection
21
N/C
No connect
22
RFOUT
23
GND
Low inductance ground connection
24
GND
Low inductance ground connection
25
GND
Low inductance ground connection
26
GND
Low inductance ground connection
27
GND
Low inductance ground connection
28
GND
Low inductance ground connection
806–928 MHz RF output signal 50 Ω
10
20
21
NC
9
18
GND
Regulated bias enable control voltage,
0.0 = Off, 2.75 V = On
17
NC
VREG
16
GND
8
15
NC
Supply voltage for base bias circuitry to all stages
(typically 3.5 V)
GND
VD4
VD3
7
Absolute Maximum Ratings
Characteristic
Value
Operating temperature
-40 °C to +85 °C
Storage temperature
-55 °C to +125 °C
1.When amplifier is biased off (VREG = 0 V).
2. Voltage on VREG pin may not exceed the applied VCC voltage.
Performance is guaranteed only under the conditions listed in the specifications table and is
not guaranteed under the full range(s) described by the Absolute Maximum specifications.
Exceeding any of the absolute maximum/minimum specifications may result in permanent
damage to the device and will void the warranty. Each absolute maximum rating listed is an
individual parameter. Biasing and driving the amplifier with more than one absolute maximum
rating listed may result in permanent damage to the device. Exposure to maximum rating
conditions for extended periods may reduce device reliability.
CAUTION: Although this device is designed to be as robust as
possible, ESD (Electrostatic Discharge) can damage
this device. This device must be protected at all times
from ESD. Static charges may easily produce potentials of several kilovolts on the human body or
equipment, which can discharge without detection.
Industry-standard ESD precautions must be employed
at all times.
Center attachment pad must have a low inductance and low thermal resistance connection to
the customer's printed circuit board ground plane.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
8
January 25, 2008 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • 200810 Rev. A
DATA SHEET • SKY65146
Evaluation Board
GND
Evaluation Board Description
VCTL
VREG
VD4
VD3
VD2
VD1
The Skyworks SKY65146 Evaluation Board is used to test the
performance of the SKY65146 power amplifier module. The following design considerations are general in nature and must be
followed regardless of final use or configuration.
GND
1. Paths to ground should be made as short as possible.
+ C1
2. The ground pad of the SKY65146 power amplifier module has
special electrical and thermal grounding requirements. This
pad is the main thermal conduit for heat dissipation. Since the
circuit board acts as the heat sink, it must shunt as much heat
as possible from the amplifiers. As such, design the connection
to the ground pad to dissipate the maximum wattage produced
to the circuit. Multiple vias to the grounding layer are required.
C2
+
C3
INPUT
SKY65146
NOTE: Junction temperature (TJ) of the device increases with a
poor connection to the slug and ground. This reduces the
lifetime of the device.
C5 C6
+
+
C4
C7
IDEN TEST FIXTURE
Application Board Test Procedure
Capacitors C6 and C7 are shown on EVB, but are not used.
Step 1. Connect RF test equipment to Amplifier input/output SMA
connectors.
Recommended Solder Reflow Profiles
Step 2. Connect DC ground.
Refer to the “Recommended Solder Reflow Profile”
Application Note.
Step 3. Connect all VCC (VD) lines to 3.5 V supply and VREG to
2.75 V. Verify the ICQ current is approximately 329 mA.
Step 4. Apply RF signal data -30 dBm level and observe that the
output level is approximately 8 dBm or the gain of the
device is approximately 38 dB.
Tape and Reel Information
Refer to the “Discrete Devices and IC Switch/Attenuators
Tape and Reel Package Orientation” Application Note.
NOTE: It is important that the VD2, VD3, and VD4 voltage source
be adjusted such that 3.5 V is measured at the board. The
high collector currents will drop the collector voltage significantly if long leads are used. Adjust the bias voltage to
compensate.
Bill of Material for Evaluation Board
Part
ID
QTY
Size
Value
Units
Manufacturer
Product Number
1
C1
1
1206
10
µF
AVX
TAJA106M006R
2
C2
1
1206
10
µF
AVX
TAJA106M006R
3
C3
1
0402
1000
pF
Murata
GRM155R71H102KA01
4
C4
1
1206
10
µF
AVX
TAJA106M006R
5
C5
1
0402
1000
pF
Murata
GRM155R71H102KA01
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
200810 Rev. A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • January 25, 2008
9
DATA SHEET • SKY65146
Evaluation Board Stack-Up
Cross Section
Package Outline
Name Thickness (mm) Material
10.04
εr
L1
0.035
Cu
–
Lam1
0.400
Rogers 4003
3.38
L2
0.035
Cu
–
Lam2
0.600
FR4
4.00
L3
0.035
Cu
–
Lam3
0.400
FR4
4.00
L4
0.035
Cu
–
Pin 1 Indicator
Top
14.04
Branding Specifications
Manufacturing Part Number
Revision Number
SKY65146
EXXXXX.XX
YYWW MX
0
4X 1.27
Mark Pin 1
Identifier
4X 2.54
4X 3.81
1.45 ± 0.1
Pin 28
(0.2x 45°)
Pin 1 Indicator
See Detail A
Pin 1
28X SMT Pad
Lot Number
See Detail B
YY = Manufacture Year
WW = Week Packaged
Sealed
MX = Country Code
C
0
12X 1
12X 2
12X 3
12X 4
4X 1.27
4X 2.54
4X 3.81
2.5
1.5
0.5
14X 4.873
14X 6.873
54X Solder Mask
Openings See Detail B
1.163 ± 0.05
(0.147)
0.889 ± 0.05
(R 0.508)
1.016
± 0.05
0.875
0.875
0.02X 45°
0.875
R 0.05
Max.
(R 0.381)
0.762
± 0.05
Detail B
Detail A
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
10
R 0.05
Max.
0.875
January 25, 2008 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • 200810 Rev. A
Detail C
DATA SHEET • SKY65146
Recommended Footprint
Solder Mask
10.34 mm
10.44 mm
14X
0.762 mm
Pin 28
0.20 X 45°
Pin 28
18X 2.5 mm
28X
0.862 mm
28X 1.286 mm
Pin 1
14X 1.186 mm
Pin 1
12X
3 mm
14.34 mm
CL
1.27 mm Typ.
0.6 mm
12X
4 mm
14.44 mm
12X
1 mm
CL
1.27 mm Typ.
12X
2 mm
0.875 mm Typ.
0.25 mm Typ.
R0.431 mm Typ.
Package Outline
R0.381 mm Typ.
Thermal via array Ø0.3 mm on
0.7 mm pitch additional vias in
common ground pad will
improve thermal performance
0.25 mm Typ.
CL
0.875 mm Typ.
CL
18X 1.5 mm
18X 0.5 mm
0.6 mm
Thermal vias should be tented and filled with solder mask 30-35 µm copper plating recommended.
Stencil Pattern
10.34 mm
Pin 28
18X 2.5 mm
28X
28X
0.762 mm 1.186 mm
0.20 X 45°
Pin 1
12X 3 mm
12X 1 mm
CL
12X 2 mm
1.27 mm 14.34 mm
Typ.
12X 4 mm
0.875 mm
Typ.
Stencil aperture size
of 80 to 100%
of the module/pkg
0.875 mm
solder mask
Typ.
openings.
Package
Outline
CL
18X 1.5 mm
18X 0.5 mm
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
200810 Rev. A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • January 25, 2008
11
DATA SHEET • SKY65146
Ordering Information
Model Name
Manufacturing Part Number
Evaluation Kit Part Number
SKY65146: 3.5 V Broadband MCM Power Amplifier 806–849 MHz
SKY65146-21 (Pb-free package)
TW16-D390
Copyright © 2007, 2008, Skyworks Solutions, Inc. All Rights Reserved.
Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided
by Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the
information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to
update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.
No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or
information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and
Conditions of Sale.
THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A
PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY
DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS
SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION,
LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE.
Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury,
death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any
damages resulting from such improper use or sale.
Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of
products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for
applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters.
Skyworks, the Skyworks symbol, and “Breakthrough Simplicity” are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and
names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are
incorporated by reference.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
12
January 25, 2008 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • 200810 Rev. A