Typical and guaranteed specifications vary versus frequency; see detailed data sheets for specification variations. High Performance Attenuators Typical and Guaranteed Specifications—50 Ω System Insertion Loss dB Model Frequency Range MHz Typ. Max. 0/50C Attenuation dB Typ. Min. 0/50C SWR In/Out Typ. Switching Speed Max. 0/50C Typ. (μs) 10-90% Control Max. (μs) 100% Volts I(mA) Max. Bias Volts I(mA) Max. Attenuators • Available in TO-8 Attenuator, Surface Mount and SMA Packages (depending on model) UTF-015 5-500 500-1000 1.5 2.0 2.0 2.5 20 20 15 15 1.5 1.6 2.0 2.1 500 500 800 800 0 to 10 0 to 10 0 to 7 0 to 7 15 15 10 10 5-500 5-1000 5-1200 2.0 2.3 2.5 2.6 2.8 3.0 36 30 27 30 25 23 1.3 1.6 1.6 2.0 2.0 2.0 2.0 2.0 2.0 125 125 125 0 to 15 0 to 15 0 to 15 0 to 7 0 to 7 0 to 7 15 15 15 15 15 15 GC2001 5-500 5-1000 5-2000 2.0 2.0 2.8 2.5 2.5 3.3 36 30 23 31 25 20 1.5 1.5 1.6 2.0 2.0 2.2 2.0 2.0 2.0 125 125 125 0 to 15 0 to 15 0 to 15 0 to 7 0 to 7 0 to 7 15 15 15 15 15 15 GC2002 5-500 5-1000 5-2000 1.5 2.0 2.5 2.0 2.5 3.0 36 30 23 31 25 20 1.6 1.6 1.7 2.0 2.0 2.2 2.0 2.0 2.0 125 125 125 0 to 15 0 to 15 0 to 15 0 to 7 0 to 7 0 to 7 5 5 5 10 10 10 5-500 500-1000 1000-2000 2000-2500 2.0 2.0 2.8 3.5 2.5 2.5 3.3 4.0 33 28 23 17 27 23 20 15 1.5 1.5 1.8 1.8 2.0 2.0 2.0 2.0 75 75 75 75 200 200 200 200 1 to 15 1 to 15 1 to 15 1 to 15 0 to 7 0 to 7 0 to 7 0 to 7 15 15 15 15 20 20 20 20 10-500 500-1000 1000-2000 2000-2500 2.0 2.3 2.8 3.0 2.8 2.8 3.3 3.5 52 43 38 35 40 35 30 28 1.2 1.2 1.2 <1.3 1.8 1.8 2.0 2.2 <1.5 <1.5 <1.5 <1.5 9.0 9.0 9.0 9.0 0 to 15 0 to 15 0 to 15 0 to 15 0 to 10 0 to 10 0 to 10 0 to 10 15 15 15 15 12 12 12 12 10-500 500-1000 1000-2000 2000-2500 2.0 2.3 2.8 3.0 2.8 2.8 3.3 3.5 52 43 38 35 40 35 30 28 1.2 1.2 1.2 <1.3 1.8 1.8 2.0 2.2 200 ηsec 200 ηsec 200 ηsec 200 ηsec 1.0 1.0 1.0 1.0 0 to 15 0 to 15 0 to 15 0 to 15 0 to 10 0 to 10 0 to 10 0 to 10 15 15 15 15 12 12 12 12 UTF-040 30-250 250-500 500-1000 2.0 2.0 2.0 2.2 2.2 2.5 45 40 35 40 35 30 1.5 1.5 1.5 2.0 2.0 2.5 400 400 400 600 600 600 0 to -10 0 to -10 0 to -10 0 to 75 0 to 75 0 to 75 15 15 15 10 10 10 UTF-030 100-500 500-1000 1000-2000 2.0 2.5 3.0 2.5 3.0 3.5 45 40 30 40 35 25 1.7 1.7 1.7 2.0 2.0 2.0 0.5 0.5 0.5 2 2 2 0 to 15 0 to 15 0 to 15 0 to 10 0 to 10 0 to 10 15 15 15 10 10 10 500-1000 1000-2000 2000-2500 1000-2000 2.3 2.8 3.0 2.5 2.8 3.3 3.5 3.0 43 38 35 25.5 35 30 28 23.5 1.2 1.2 <1.3 1.6 1.8 2.0 2.2 2.0 <100 ηsec <100 ηsec <100 ηsec 5 1.0 1.0 1.0 25 0 to 15 0 to 15 0 to 15 -2 to -10 0 to 10 0 to 10 0 to 10 0 to 40 15 15 15 15 12 12 12 50 GC1275 (75Ω) UTF-025 GC2510 GC2530 GC2534 Current data sheets available on website. 650-691-9800 • Fax: 650-962-6845 • Updates: www.teledynemicrowave.com • [email protected] Typical and guaranteed specifications vary versus frequency; see detailed data sheets for specification variations. High Performance Attenuators Typical and Guaranteed Specifications—50 Ω System Insertion Loss dB Model Frequency Range MHz Typ. Attenuation dB Max. 0/50C Typ. SWR In/Out Min. 0/50C Typ. Switching Speed Max. 0/50C Typ. (μs) 10-90% Control Max. (μs) 100% Volts Bias I(mA) Max. Volts I(mA) Max. Attenuators • Available in TO-8 Attenuator, Surface Mountnumber and SMA Packages (depending on model) Models listed by model 5-500 5-1000 5-2000 2.0 2.3 2.8 2.8 3.0 3.5 36 30 27 30 25 23 1.3 1.6 1.6 2.0 2.0 2.0 2.0 2.0 2.0 75 75 75 +2 to –10 0 to 15 +2 to –10 0 to 15 +2 to –10 0 to 15 15 15 15 40 40 40 50-1000 1000-2000 2.0 2.5 2.5 3.0 25.5 25.5 23.5 23.5 1.6 1.6 2.0 2.0 5 5 25 25 -2 to -10 0 to 40 -2 to -10 0 to 40 15 15 50 50 100-1000 PSF-030-25 1000-2000 2000-4000 2.5 2.5 2.5 3.0 3.0 3.0 45 40 30 40 35 25 1.7 1.7 1.7 2.0 2.0 2.0 0.5 0.5 0.5 2.0 2.0 2.0 0 to 15 0 to 15 0 to 15 15 15 15 10 10 10 GRS6012 2.0 4.5 20 18 1.8 2.0 ±5 3 GR2010^ UTF-0351 0.3-6000 Insertion Loss dB Model Frequency Range GHz Typ. Max. 0/50C Attenuation dB Typ. <100 ηsec 160 ηsec SWR In/Out Min. 0/50C Typ. 0 to 10 0 to 10 0 to 10 0 to -5 Switching Speed Max. 0/50C Typ. (μs) 10-90% Control Max. (μs) 100% Volts I(mA) Max. Attenuators • Available in CougarPak® Connectorized Packages GCP6021 2.0 - 6.0 3.0 - 5.0 1.5 1.3 2.5 1.5 17 16 15 15 1.5 1.5 1.8 1.7 3.8 3.8 4.5 4.5 5 5 26 26 GCP8022 4.0 - 7.0 3.0 - 8.0 2.4 3.0 2.9 3.5 40 40 38 37 1.5 1.5 1.7 1.7 2.5 2.5 4.7 4.7 5 5 52 52 5.0 - 8.0 8.0 - 14.0 14.0 - 15.0 2.2 2.0 2.8 2.7 2.5 3.0 22 21 22 20 19 20 2.0 1.6 1.3 2.2 1.8 1.5 2.0 2.0 2.0 4.5 4.5 4.5 5 5 5 25 25 25 GCP14021 Model Frequency Range MHz Typical Current Drain Control Voltage= Control Voltage= -10 V @ 0V @ Min. Attenuation Max. Attenuation VV+ Vcon VV+ Vcon Linearity Specifications^ 10-1000 MHz Attenuation Range: 0 to 20 dB 25°C Volts -55°/85°C Typ. Max. Typ. Max. Attenuator Linearizer • Available in Linearized TO-8 Attenuator and SMA Packages LG20011 5-2000 5.0 mA 24.0 mA 15.0 mA 5.0 mA 11.0 mA 2.5 mA <±1.0 dB <±1.5 dB <±1.5 dB <±2.0 dB Current data sheets available on website. 1 Linearizer and attenuator in one package. ^ Specifications apply to LG2001 used in conjunction with model GC2001. 650-691-9800 • Fax: 650-962-6845 • Updates: www.teledynemicrowave.com • [email protected]