PSF-030-25 - Teledyne Cougar

Voltage Controlled Attenuator
.1 to 4 GHz
Technical Data
PSF-030-25
Features
Description
Pin Configuration
• Frequency Range: 0.1 to
4 GHz, usable to 5 GHz
The PSF-030 is a thin film
analog voltage controlled
attenuator providing 30 to
50 dB of range depending on
frequency and flatness requirements. It uses PIN diodes in a
modified Pi configuration to
maintain low VSWR performance over the control range.
The PSF-030-25 comes in our
smallest hermetic surface
mount package and offers
higher performance than the
PSF-030-45.
SM-25F
• 30 dB attenuation range,
50 dB at 500 MHz
• Temperature Stable
• Well matched throughout
attenuation range
• Surface Mount Package
Applications
• AGC/ALC loops
+15
RFIN
RFOUT
VC
• AM modulator
• Non-reflective SPST switch
Schematic
Maximum Ratings
Parameter
DC Voltage
Continuous RF Input Power
Operating Case Temperature
Storage Temperature
“R” Series Burn-In Temperature
Weight: (typical) 0.5 grams
Maximum
+17 Volts
+23 dBm
–55 to +125°C
–62 to +150°C
+125°C
030 Series
2
Electrical Specifications
(Measured in 50 Ω system @ ±15 VDC nominal unless otherwise noted)
Symbol
BW
—
—
—
—
—
—
—
—
Characteristic
Frequency Range
Attenuation, Min. (Vc = O V)
100–1000 MHz
1000–2000 MHz
2000–4000 MHz
Insertion Loss, Max (Vc = +15V)
VSWR
(Worst Case In Attenuation Range)
Flatness Over Frequency (to 25 dB)
100–2000 MHz
2000–4000 MHz
Switching Speed (10% to 90%)
(ON to OFF or OFF to ON)
Bias Current
Control Voltage
Control Current
Typical
Guaranteed Specifications
Unit
TC = 25°C TC = 0 to 50°C TC = –55 to +85°C
100–5000
100–4000
100–4000
MHz
45
40
30
2.5
40
35
25
3.0
30.0
25.0
20.0
3.5
dB
dB
dB
dB
1.7:1
2.0:1
2.0:1
—
±0.5
±1.0
±1.0
±1.5
±1.0
±1.5
dB
dB
.5
8.0
0 to +15
0 to 10
1
—
—
—
1
—
—
—
µs
mA
VDC
mA
030 Series
3
Typical Performance Over Temperature (@ ±15 VDC unless otherwise noted)
Attenuation vs. Frequency @ Vc
Insertion Phase vs. Frequency @ Vc
0
-40
Vc=15
-20
-20
3.87
0
2.76
2.35
-30
Vc=15
7.23
2.16
2.04
-40
1.97
Insertion Phase - dB
Attenuation - dB
-10
7.23
3.87
2.76
20
2.35
40
2.16
60
2.04
1.97
80
1.92
-50
1.92
100
0
-60
0
120
0
1
2
3
4
5
0
Frequency - GHz
1
2
3
4
5
Frequency - GHz
Output Return Loss vs. Frequency
Input Return Loss vs. Frequency
0
0
Vc=15
Vc=15
7.23
-5
7.23
-5
3.87
2.76
2.35
-15
2.16
2.04
-20
Return Loss - dB
Return Loss - dB
3.87
-10
-10
2.76
2.35
-15
2.16
2.04
-20
1.97
1.97
1.92
-25
1.92
-25
0
0
-30
-30
0.01
0.1
1
0.01
10
0.1
1
10
Frequency - GHz
Frequency - GHz
Attenuation vs. Control Voltage (Freq. = 1 GHz)
Switching Speed
0
Tc = +25
Tc = -55C
-10
Attenuation - dB
Tc = +85
-20
-30
-40
-50
0
2
4
6
8
10
12
14
Control Voltage - volts
Top Trace: control pulse, 0–10v
Bottom Trace: detected RF (pos detection)
Case Drawings
0.015±0.001
4 PL
0.050±0.015
8 PL
0.040
4 PL
0.010
TYP
4
R0.010
4 PL
0.040
1
CL
3
0.230
0.055
TYP
+
+
0.040
TYP
0.025
TYP
2
0.030
3 PL
0.010
0.230
PKG #
0.250 SQ
0.120 MAX
0.008±0.001
SM-25
SM-25F
SM-25DA
SM-25DD
1
RF IN
RF IN
RF IN
RF IN
PIN DESIGNATION
2
3
GND
RF OUT
V-CONT
RF OUT
–V
VID OUT
CTL
TTL OUT
4
+V
+V
+V
+V
NOTES:
1. MAXIMUM TEMPERATURE EXPOSURE IS
260°C FOR 10 SECONDS.
2. DIMENSIONS IN INCHES.
3. TOLERANCES: xxx ± .01
xxx ± .005
Contact Teledyne Microwave Solutions:
650-691-9800
650-962-6845 fax
Check for updates:
www.teledynemicrowave.com