1400W - SynQor

Technical
Specification
ACuQor Single Output
Medical Grade AC/DC Power Supply With PFC
85-264Vrms
12/15/24/28/48V
Input Voltage
Semi-Regulated Output
1400W
1800W
92%
Output Continuous Output Transient
Full Load Efficiency
4.
75
"
7"
Product Features
• High efficiency (92% for 48 VOUT Model at 1400W)
• Universal input voltage range
• Semi-regulated output for bus stability
• Integral fan cooling with speed control
• Active PFC; EN61000-3-2 compliant
• Low leakage; EN60601-1 compliant
• Low noise; EN55011 / EN55022 Class B compliant
Product # AQ1400MUxx
Phone 1-888-567-9596
• Over–current, over–voltage, and over–temp protection
• DC Power Good / AC Power Good signals
• Remote enable input
• Fan status output
• Small size: 4.75" x 7" x 1.625" (encased)
• RoHS 6/6 compliant
• 5 V (500 mW) standby output
www.SynQor.com
Doc.# 005-0005088 Rev. C
05/04/12
Page 1
AC Input:
DC Output:
Power:
Grade:
85-264Vrms
12/15/24/28/48V
1400W
Medical
ACuQor 1400W Series Electrical Characteristics
All specifications typical with TA = 25 °C, unless otherwise specified.
MAIN OUTPUT SPECIFICATIONS
GENERAL SPECIFICATIONS
Output power (continuous) 85-132/170-264 Vrms
(5 s transient)
85-132/170-264 Vrms
132-170 Vrms
Nominal DC output
12 Vout
voltage (at 800W)
15 Vout
(Semi-regulated)
24 Vout
28 Vout
48 Vout
Efficiency (see figs. 1 - 10) 12 Vout, 115 Vrms, 1400W
1400W
1800W
See Figure 12
12.4 V
15.6 V
25 V
29 V
50 V
87% typ.
24 Vout, 115 Vrms, 1400W
89% typ.
48
12
24
48
Hold-up time (to -20%)
12
24
Maximum load capacitance 12
15
24
28
48
Output ripple voltage
Vout, 115 Vrms,
Vout, 230 Vrms,
Vout, 230 Vrms,
Vout, 230 Vrms,
/ 15 Vout
/ 28 / 48 Vout
Vout
Vout
Vout
Vout
Vout
1400W
1400W
1400W
1400W
Switching frequency (20 MHz BW)
Twice line frequency (at 800W)
Turn-on delay
Transient response
Iout steps from 50-75%
At 0.2 A/µs
Cyclic restart
Cyclic operation
Over line, load and temperature
Always on (See Note 1)
Automatic recovery
Input Low Voltage
Input High Voltage
Overvoltage protection
Short circuit protection
Total regulation
Auxiliary Output
Thermal protection
REMOTE_ENABLE
INPUT SPECIFICATIONS
AC input voltage
Input frequency
Input current
90% typ.
89.5% typ.
90.5% typ.
91.5% typ.
10 ms @ 1400W
12 ms @ 1400W
48,000 µF
40,500 µF
24,000 µF
19,200 µF
6,000 µF
Audible noise
Weight
MTBF
115 Vrms @ 1400W
230 Vrms @ 1400W
264 Vrms (cold start)
Both AC lines
85-264 Vrms
47-63 Hz
14 Arms
7 Arms
>0.98
50 A max.
20 A
Input
Output
Fan speed varies with temp.
( AQ0800xxxxGC )
( AQ1100xxxxGC )
( AQ1400xxxxGC )
MIL-217
Demonstrated
500 kHz
250 kHz
45 dBA @ 1 m max.
998 g (35.2 oz)
1179 g (41.6 oz)
1179 g (41.6 oz)
533 kHours
TBD kHours
ISOLATION SPECIFICATIONS
Isolation voltage
Insulation resistance
Input to output
Input to ground
Output to ground (B)
Output to ground (BF & CF)
Output to ground (CFD)
4000 Vrms
1500 Vrms
500 Vrms
1500 Vrms
5000 Vpulse
Output to ground
10 MΩ min.
Leakage currents
See Note 2
ENVIRONMENTAL CHARACTERISTICS
Thermal performance
Relative humidity
0.5% p-p Altitude
5.0% p-p
Random vibration
2 s max. Shock
3% typ / 6% max. dev.
100 ms recovery
Conducted emissions
110-120%
115% rated Iout Line frequency harmonics
±6.0%
5 V @ 100 mA Voltage fluctuations
+125 ºC (PCB Temp) ESD air
0.45 V (max) ESD contact
4.15 V (min) Radiated immunity
Universal range
Power factor
Input surge current
Internal input fuses
Fundamental ripple freq.
Operating ambient (see Figure 11)
Non-operating ambient
Non-condensing
Operating
Non-operating
5-500 Hz
Half-sine, 10 ms, 3 axes
0 ºC to +70 ºC
-40 ºC to +85 ºC
5-95% RH
10,000 ft max.
30,000 ft max.
0.03 g2/Hz
20 g peak
EMC CHARACTERISTICS
EN55011 and EN55022, FCC
part15
EN61000-3-2
Level B
Class A
EN61000-3-3
Clause 5b
EN61000-4-2
Level 3
EN61000-4-2
Level 3
EN61000-4-3
Level 3
Fast transients
EN61000-4-4
Level 3
Line surge immunity
EN61000-4-5
Level 3
Conducted immunity
EN61000-4-6
Level 3
Power freq. mag. field
EN61000-4-8
Voltage dip immunity
EN61000-4-11
3 A/m
Perf Criteria B, A, B
<5% UT 10 ms,
70% UT 500 ms,
40% UT 100 ms
NOTES:
1. Derate 2 mA per °C above 50 °C ambient temperature.
2. Leakage currents see page 4.
SAFETY AGENCY CERTIFICATIONS
UL60601-1:2003
CAN/CSA-22.2 No. 601.1-M90
EN 60601-1/A2:1995
IEC 60601-1/A2:1995
CAN/CSA-C22.2 No. 60601-1-08
ANSI/AAMI ES60601-1:2005
EN 60601-1:2006
IEC 60601-1:2005
CE Marked
Meets NFPA 99 2005 300 μA earth leakage
Product # AQ1400MUxx
Phone 1-888-567-9596
www.SynQor.com
Doc.# 005-0005088 Rev. C
05/04/12
Page 2
AC Input:
DC Output:
Power:
Grade:
85-264Vrms
12/15/24/28/48V
1400W
Medical
EFFICIENCY, DERATING, AND VOUT DROOP CURVES
100
95
Efficiency (%)
90
85
80
75
115 Vrms
230 Vrms
70
65
0
300
600
900
1200
Output Power (W)
1500
1800
Figure 1: 12 VOUT efficiency curves.
Figure 2: 12 VOUT droop characteristic.
100
95
Efficiency (%)
90
85
80
75
115 Vrms
230 Vrms
70
65
0
300
600
900
1200
Output Power (W)
1500
1800
Figure 4: 15 VOUT droop characteristic.
Figure 3: 15 VOUT efficiency curves.
100
95
Efficiency (%)
90
85
80
75
115 Vrms
230 Vrms
70
65
0
300
600
900
1200
Output Power (W)
Figure 5: 24 VOUT efficiency curves.
Product # AQ1400MUxx
Phone 1-888-567-9596
1500
1800
Figure 6: 24 VOUT droop characteristic.
www.SynQor.com
Doc.# 005-0005088 Rev. C
05/04/12
Page 3
AC Input:
DC Output:
Power:
Grade:
85-264Vrms
12/15/24/28/48V
1400W
Medical
100
95
Efficiency (%)
90
85
80
75
115 Vrms
230 Vrms
70
65
0
300
600
900
1200
1500
Output Power (W)
1800
Figure 7: 28 VOUT efficiency curves.
Figure 8: 28 VOUT droop characteristics.
100
95
Efficiency (%)
90
85
80
75
115 Vrms
230 Vrms
70
65
0
300
600
900
1200
1500
Output Power (W)
1800
Figure 9: 48 VOUT efficiency curves.
Figure 10: 48 VOUT droop characteristics.
AC Leakage Current
from Input to Earth
AC Line Connection
Normal Open Neutral
Condition
Fault
ACuQor Typical at
110% nominal input
voltage 60 Hz
240 V L-N, 1 phase
220 µA
440 µA
208 V L-L, 120 V L-N, 1 of 3 phases
120 µA
240 µA
240 V L-N-L, 120 V L-N, split phase
120 µA
240 µA
AC Leakage Current
from Output to Earth
ACuQor Typical at
264 Vac 60 Hz input
Model
Normal
Condition
Open Earth
Fault
AC Backdrive
Fault
AQ . . B . . .
4 µA
65 µA
—
AQ . . BF . .
4 µA
40 µA
78 µA
AQ . . CF . .
4 µA
20 µA
39 µA
Contact Type
Normal
Condition
Open Earth
Fault
AC Backdrive
Fault
B
100 µA
500 µA
—
BF
100 µA
500 µA
5000 µA
CF
10 µA
50 µA
50 µA
For convenience, the following tables show limits allowed by various standards:
AC Leakage Current
from Input to Earth
Maximum Allowed
per Standard
Standard
Normal Open Neutral
Condition
Fault
IEC60601-1
500 µA
1000 µA
NFPA 99 2005
300 µA
—
IEC60950
3500 µA
—
AC Leakage Current
from Output to Earth
Maximum Allowed per
IEC60601-1
Table 1: Leakage Currents
Product # AQ1400MUxx
Phone 1-888-567-9596
www.SynQor.com
Doc.# 005-0005088 Rev. C
05/04/12
Page 4
1600
1500
1400
1300
1200
1100
1000
900
800
700
600
500
400
300
200
100
0
Power (W)
Power (W)
AC Input:
DC Output:
Power:
Grade:
0
10
20
30
40
50
60
70
2000
1900
1800
1700
1600
1500
1400
1300
1200
1100
1000
900
800
700
600
500
400
300
200
100
0
Transient
Continuous
85
80
110
105
140
132
170
190
264
Input AC Voltage (VRMS)
Ambient / Case Temperature (ºC)
Figure 11: Continuous power derating curve in natural convection.
85-264Vrms
12/15/24/28/48V
1400W
Medical
Figure 12: Rated output power vs Input AC Voltage.
OUTPUT DATA CONNECTOR PINOUT
Pin 1
Reserved
Reserved for future use.
Pin 2
Reserved
Reserved for future use.
Pin 3
VOUT(–)
Pin 4
REMOTE_ENABLE
Pin 5
FAN_GOOD
Pin 6
AC_POWER_GOOD
Pin 7
DC_POWER_GOOD
Negative Output Voltage
Logic input. See Figure B.
Pull high to enable main output.
Open collector with internal 5 V pullup. See Figure A.
Pulsed low on fan failure, 100 ms, 50% duty.
Open collector with internal 5 V pullup. See Figure A.
Pulled low on AC power dropout.
Open collector with internal 5 V pullup. See Figure A.
Pulled low during startup ramp and within 5ºC of
temperature shutdown threshold.
Pin 8
5V_STANDBY
Pin 1
VOUT(+)
Positive Output Voltage
Pin 2
VOUT(–)
Negative Output Voltage
Pin 3
VOUT(+)
Positive Output Voltage
Pin 4
VOUT(–)
Negative Output Voltage
Pin 5
VOUT(+)
Positive Output Voltage
Pin 6
VOUT(–)
Negative Output Voltage
Pin 7
VOUT(+)
Positive Output Voltage
Pin 8
VOUT(–)
Negative Output Voltage
Figure A: Power good and fan good interface circuitry.
5 V @ 100 mA available whenever AC power is applied.
OUTPUT POWER CONNECTOR PINOUT
INPUT CONNECTOR PINOUT
Pin 1
Ground
Pin 2
AC Neutral
Pin 3
AC Line
Product # AQ1400MUxx
Phone 1-888-567-9596
Figure B: Remote enable interface circuitry.
MATING CONNECTORS
Connector
Type
Contact
OUTPUT (Power)
Positronic PLA08M7
Positronic MS112N
OUTPUT (Data)
Molex 43025-0800
Molex 43030-0008
INPUT
Hirose DF22B-3S-7.92C
Hirose DF22A-1012SC
www.SynQor.com
Doc.# 005-0005088 Rev. C
05/04/12
Page 5
AC Input:
DC Output:
Power:
Grade:
85-264Vrms
12/15/24/28/48V
1400W
Medical
MECHANICAL DRAWINGS
.19 PLASTIC RIVET OD.
[ 4,8 ]
6-32 SELF CLINCHING INSERT
MOUNTING SCREW SHALL NOT
PROTRUDE 3/8" INTO THE CHASSIS
x4
7.00
[177,8]
6.60
[167,6 ]
6.63
[168,3]
4.30
[109,2 ]
.75
[19,1 ]
2.28
4.75
4.84
[57,8 ]
.16
[4,1 ]
.20
[5,1 ]
.25
[6,4 ]
4.25
[108 ]
[120,7]
[123 ]
FRONT VIEW
BACK VIEW
1.03 .04
[26,1 1 ]
.62 .03
[15,8 0,7 ]
.51 .03
[13 0,7 ]
1.63
[41,3 ]
1.31 .03 [33,3 0,7 ]
OUTPUT POWER PIN 1
.89 .03 [ 22,5 0,7 ]
INPUT PIN 1
3.47 .03 [88,2 0,7 ]
OUTPUT DATA PIN 1
NOTES
1. Recommended screw tightening torque of 6in.. lbs.
2. Undimensioned components are shown for visual reference only
3. All dimensions in inches [mm]
Tolerances: x.xx in ± 0.02
x.xxx in ± 0.010
Product # AQ1400MUxx
Phone 1-888-567-9596
www.SynQor.com
Doc.# 005-0005088 Rev. C
05/04/12
Page 6
AC Input:
DC Output:
Power:
Grade:
85-264Vrms
12/15/24/28/48V
1400W
Medical
INSTALLATION INSTRUCTIONS
GENERAL: ACuQor power supplies are intended for use as
components in medical and industrial equipment. ACuQor
units must be properly installed within end use equipment
before they can be safely applied as described in this document.
The suitability of the ACuQor/equipment combination
must be verified through end product investigation.
MOUNTING: Refer to the Mechanical Drawings section.
ACuQor units are provided with threaded stainlesssteel stand-offs or inserts for mounting. This mounting
hardware is internally connected to the input connector
protective-earth terminal for functional-earth EMC control.
Any orientation (vertical, horizontal, etc.) may be used.
Adequate air space should be provided over the fan
intake (top) and exhaust (sides) to allow for exchange of
cooling air. ACuQor is designed for a pollution degree 2
environment. A minimum of 5 mm electrical clearance should
be allowed from the connector ends of encased models.
INPUT: Refer to the Connector Details section for input
connector wiring.
ACuQor products require a single
phase AC power source of 100-240V 50/60Hz nominal.
Refer to nameplate label for input current ratings. A
protective-earth connection is also required. Minimum
wire size of 14 AWG (2.5mm2) is recommended. Both
sides of the AC line are internally fused (see table for
specific models). These fuses are not user replaceable.
OUTPUT: Refer to the Connector Details section for
output connector wiring and signal I/O functionality.
Refer to nameplate label for output current ratings.
Main DC output (Vout+, Vout-) pins should use 12 AWG
(4.0mm2) wire size. Individual main output pins should
not be loaded to more than 30 A. For currents greater
than 30 A, multiple main output pins/wires must be used
in parallel. All signal I/O pins are referenced to Vout-.
MODEL
AQ0800
AQ1100
AQ1400
Input Fuses
(in Both AC Lines)
Cooper Bussmann 20A 250V GBB-20
Cooper Bussmann 20A 250V GBB-20
Cooper Bussmann 20A 250V GBB-20
EMC: ACuQor products have been tested to the EMC
specifications listed in the section of this datasheet titled
Electrical Characteristics, on page two. However, end
use equipment must be tested to verify EMC compliance.
PATIENT CONTACT: ACuQor models include versions
designed for B, BF and CF patient contact application
per IEC60601-1. The BF and CF ACuQor models provide
reinforced insulation at the DC output voltage level and basic
insulation at the 240 Vac level from output to protectiveearth. Note that equipment and wiring may add to system
leakage currents so that the end product must be tested for
compliance. Refer to the Electrical Characteristics section
for typical ACuQor input and output leakage currents. In
addition, ACuQor defibrillation rated models comply with
the minimum output to protective-earth creepage/clearance
requirement and defibrillator pulse test of IEC60601-1.
HIPOT TESTING: ACuQor products are rated for Hipot
testing levels of 1500 Vac input to protective-earth, 1500
Vac output to protective-earth, and 4000 Vac input to
output. When performing the 4000 Vac input to output
test, the test voltage must be balanced evenly 2000 Vac
input and output to protective-earth. Two oppositely
phased test voltage sources or a single test voltage
source with external balancing impedances (capacitors)
may be used to prevent overstressing input or output
to protective-earth insulation per IEC60601-1 2005 sub
clause 8.8.1 and IEC60601-1 1990 sub clause 20.4.
CONDUCTIVE COOLING:
This product requires
supplemental conductive cooling through its case to
maintain the rated output power. The case should be
mounted to a system chassis or heat sink with a thermally
conductive interface material and kept at 50°C maximum
to maintain full power rating of the product. For detailed
applications assistance, consult Applications Engineering
through the sales channel.
Fuses
Total
2
2
2
Table 2: AC line fuses for specific ACuQor Medical Models
Product # AQ1400MUxx
Phone 1-888-567-9596
www.SynQor.com
Doc.# 005-0005088 Rev. C
05/04/12
Page 7
AC Input:
DC Output:
Power:
Grade:
85-264Vrms
12/15/24/28/48V
1400W
Medical
PART NUMBERING SYSTEM
The part numbering system for SynQor’s ACuQor AC/DC power supplies follows the format shown in the table below.
Not all combinations make valid part numbers, please contact SynQor for availability.
Family
AQ:
ACuQor series
of AC-DC
semi-regulated
output power
supplies
Output Power
0800: 800W
1100: 1100W 1400: 1400W
Grade
Range
M: (Medical)
I: (Industrial)
U: Universal
(85-264 VRMS)
Output
Voltage
12: 12V
15: 15V
24: 24V
28: 28V
48: 48V
Package
Type
G: 1 unit
(5"x7")
Thermal
Design
C: Encased
Options
Medical Grade
B:
B isolation rating
BF: BF isolation rating
CF: CF isolation rating
CFD: CF isolation rating
defibrillator proof
IND: Industrial Grade
Example: AQ1400MU24GCCFD
ACCESSORIES
SynQor offers a series of assemblies that can be ordered according to the table below. Mechanical drawings for these
accessories are available for download in pdf format from the SynQor website.
Part Number
AQ-CBL-INPUT1CG
AQ-CBL-OUT1CDG
Description
Input mating cable with pre-stripped wire ends (36” long)
Output mating cables (Signal and Power) with pre-stripped wire ends (18” long)
APPLICATION NOTES
A variety of application notes and technical white papers can
be downloaded in pdf format from the SynQor website.
Online Application Notes
Online Library of Technical White Papers
SynQor website.
Contact SynQor for further information:
Phone:
978-849-0600
Toll Free: 888-567-9596
Fax:
978-849-0602
E-mail:
[email protected]
Web:
http://www.synqor.com/
Address: 155 Swanson Road
Boxborough, MA 01719
USA
Product # AQ1400MUxx
Phone 1-888-567-9596
PATENTS
SynQor holds the following U.S. patents, one or more of which apply to
each product listed in this document. Additional patent applications may
be pending or filed in the future.
5,999,417
6,222,742
6,545,890
6,577,109
6,594,159
6,731,520
6,894,468
6,896,526
6,927,987
7,050,309
7,072,190
7,085,146
7,119,524
7,269,034
7,272,021
7,272,023
7,558,083
7,564,702
7,765,687
7,787,261
8,023,290
8,149,597
Warranty
SynQor offers a three (3) year limited warranty. Complete warranty
information is listed on our website or is available upon request from
SynQor.
Information furnished by SynQor is believed to be accurate and reliable.
However, no responsibility is assumed by SynQor for its use, nor for any
infringements of patents or other rights of third parties which may result
from its use. No license is granted by implication or otherwise under any
patent or patent rights of SynQor.
www.SynQor.com
Doc.# 005-0005088 Rev. C
05/04/12
Page 8