High Voltage 2-Electrode Gas Discharge Tube (GDT)

High Voltage 2-Electrode Gas Discharge Tube (GDT)
UN2E8 / UN2H8 Series
Description
UN2E8-XXXLL
UN2H8-XXXLL
UN2E8-XXXL
UN2H8-XXXL
The high voltage (1.0 - 6.0KV) gas discharge tubes are designed
for surge protection and high isolation applications, and for
applications for which bias voltages or signal levels of several
hundred volts are normally present.
Schematic Symbol
Agency Approvals
Features
u
Non-Radioactive
u
RoHS compliant
u
Low insertion loss
u
Excellent response to fast rising transients
u
Ultra low capacitance
u
5KA surge capability tested with 8/20μs
pulse as defined by IEC 61000-4-5
Product Characteristics
Materials
Applications
u
u
u
u
u
Product
Marking
CRT terminals
CATV equipment
Antennas
Power supplies
Medical electronics
Nickel-plated with Tinplated wires
UNION XXXXL
XXXX -Nominal voltage
L
-5KA
Glow to Arc
Transition
Current
< 0.5 Amps
Glow Voltage
~180 Volts
Storage and
Operational
Temperature
-40 to +90°C
UN2E8-XXXLL
~1.5g
UN2E8-XXXL
~1.35g
UN2H8-XXXLL
~1.6g
UN2H8-XXXL
~1.45g
Weight
UN Semiconductor Co., Ltd.
Revision October 18, 2013
www.unsemi.com.tw
1/4
@ UN Semiconductor Co., Ltd. 2013
Specifications are subject to change without notice.
Please refer to www.unsemi.com.tw for current information.
High Voltage 2-Electrode Gas Discharge Tube (GDT)
UN2E8 / UN2H8 Series
Dimensions
(Unit: mm)
Figure 3
Figure 1
Figure 2
Figure 4
Electrical Characteristics
Service Life
Part Number
UN2E8-1000LL
UN2E8-1000L
UN2E8-1600LL
UN2E8-1600L
UN2E8-2000LL
UN2E8-2000L
UN2E8-2500LL
UN2E8-2500L
UN2E8-2700LL
UN2E8-2700L
UN2E8-3000LL
UN2E8-3000L
UN2E8-3500LL
UN2E8-3500L
UN2H8-4000LL
UN2H8-4000L
UN2H8-4500LL
UN2H8-4500L
UN2H8-5000LL
UN2H8-5000L
UN2H8-5500LL
UN2H8-5500L
UN2H8-6000LL
UN2H8-6000L
Figure Marking
1
3
1
3
1
3
1
3
1
3
1
3
1
3
2
4
2
4
2
4
2
4
2
4
DC
Spark-over
Voltage
Maximum Impulse
Spark-over Voltage
Minimum
Insulation
Resistance
Maximum
Arc
Capacitance Voltage
Nominal
Impulse
Discharge
Current
Max
Impulse
Discharge
Current
@1MHz
@1A
@8/20μs
±5 times
@8/20μs
1 time
1 GΩ
(at 100V)
1.5pF
~25V
5KA
10KA
2400V
1 GΩ
(at 100V)
1.5pF
~25V
5KA
10KA
3000V
3500V
1 GΩ
(at 100V)
1.5pF
~25V
5KA
10KA
2500V±20%
3800V
4000V
1 GΩ
(at 100V)
1.5pF
~25V
5KA
10KA
2700L
2700V±20%
3800V
4000V
1 GΩ
(at 100V)
1.5pF
~25V
5KA
10KA
3000L
3000V±20%
4300V
4500V
1 GΩ
(at 100V)
1.5pF
~25V
5KA
10KA
3500L
3500V±20%
4800V
5000V
1 GΩ
(at 100V)
1.5pF
~25V
5KA
10KA
4000L
4000V±20%
5400V
5600V
1 GΩ
(at 100V)
1.0pF
~25V
5KA
10KA
4500L
4500V±20%
5800V
6000V
1 GΩ
(at 100V)
1.0pF
~25V
5KA
10KA
5000L
5000V±20%
6000V
6500V
1 GΩ
(at 100V)
1.0pF
~25V
5KA
10KA
5500L
5500V±20%
6500V
7000V
1 GΩ
(at 100V)
1.0pF
~25V
5KA
10KA
6000L
6000V±20%
7500V
8000V
1 GΩ
(at 100V)
1.0pF
~25V
5KA
10KA
@100V/S
@100V/μs
@1KV/μs
1000L
1000V±20%
1500V
1600V
1600L
1600V±20%
2200V
2000L
2000V±20%
2500L
Notes:
1). Terms in accordance with ITU-T K.12 and GB/T 9043-2008
2). At delivery AQL 0.65 level Ⅱ, DIN ISO 2859
UN Semiconductor Co., Ltd.
Revision October 18, 2013
www.unsemi.com.tw
2/4
@ UN Semiconductor Co., Ltd. 2013
Specifications are subject to change without notice.
Please refer to www.unsemi.com.tw for current information.
High Voltage 2-Electrode Gas Discharge Tube (GDT)
UN2E8 / UN2H8 Series
Electrical Rating
Item
Test Condition / Description
DC Spark-over Voltage
Impulse Spark-over
Voltage
The voltage is measured with a slowly rate of rise dv / dt=100V/s
The maximum impulse spark-over voltage is measured with a rise time of
dv / dt=100V//μs or 1KV/μs
Insulation Resistance
Capacitance
Requirement
The resistance of gas tube shall be measured each terminal each other terminal,
please see above spec.
The capacitance of gas tube shall be measured each terminal to each other
terminal.
Test frequency :1MHz
The maximum current applying a waveform of 8/20μs that can be applied across
the terminals of the gas tube. One hour after the test is completed, re-testing of the
DC spark-over voltage does not exceed ±30% of the nominal DC spark-over
voltage. Dwell time between pulses is 3 minutes.
To meet
the specified
value
Nominal Impulse
Discharge Current
Recommended soldering profile
Reflow soldering
Wave soldering
Soldering profile applied a single process
Soldering Parameters - Hand Soldering
Solder Iron Temperature: 350°C +/-5°C
Heating Time: 5 seconds max.
UN Semiconductor Co., Ltd.
Revision October 18, 2013
www.unsemi.com.tw
3/4
@ UN Semiconductor Co., Ltd. 2013
Specifications are subject to change without notice.
Please refer to www.unsemi.com.tw for current information.
High Voltage 2-Electrode Gas Discharge Tube (GDT)
UN2E8 / UN2H8 Series
Part Numbering
UN2E8 – XXX L L
L,
No,
with axial wire
without wire
8/20μs Level
L, 5KA
Nominal DC Spark-over Voltage
1000 = 1000V
3000=3000V
1600 = 1600V
3500=3500V
2000 = 2000V
4500=4500V
2500 = 2500V
5500=5500V
Series
Packaging Information
Unit: mm
Part Number
Description
Quantity
UN2E8-XXXLL
100PCS per Tray, 10 Trays / Inner Carton
1000
UN2H8-XXXLL
50PCS per Tray, 10 Trays / Inner Carton
500
UN2E8-XXXL
100PCS per Tray, 10 Trays / Inner Carton
1000
UN2H8-XXXL
100PCS per Tray, 10 Trays / Inner Carton
1000
Tray used in UN2E8-XXXLL
Tray used in UN2H8-XXXLL
Tray used in UN2E8 / 2H8-XXXL
Cautions and warnings
u
Gas discharge tubes (GDT) may become hot in case of longer periods of current stress (danger of burning).
u
Gas discharge tubes (GDT) may be used only within their specified values. In the event of overload, the head contacts may
fail or the component may be destroyed.
u
Damaged Gas discharge tubes (GDT) must not be re-used.
UN Semiconductor Co., Ltd.
Revision October 18, 2013
www.unsemi.com.tw
4/4
@ UN Semiconductor Co., Ltd. 2013
Specifications are subject to change without notice.
Please refer to www.unsemi.com.tw for current information.