socay.com

Surface Mount 2-Electrode Gas Discharge Tube (GDT)
UN1812 Series
Description
Gas discharge Tubes (GDT) are classical components for
protecting the installations of the telecommunications. It is
essential that IT and telecommunications systems -with their
high-grade but sensitive electronic circuits - be protected by
arresters.
The 1812 series GDT offers high surge ratings in a miniature
package. It’s designed for surface mounting on PCB with small size
4.5x3.2x2.7mm. Low insertion loss is perfectly suited to broadband
equipment applications. The capacitance does not vary with
voltage, and will not cause operational problems with ADSL2+,
Schematic Symbol
where capacitance variation across Tip and Ring is undesirable.
These devices are extremely robust and are able to divert a 500A
pulse in a miniature package 1812 without destruction.
Agency Approvals
Features
u
u
u
u
u
u
u
Non-Radioactive
RoHS compliant
Ultra low capacitance (<1.0 pF)
UL recognized
Excellent response to fast rising transients
2KA surge capability tested with 8/20μs
pulse as defined by IEC 61000-4-5
Square Outline
AGENCY
E341061
Product Characteristics
Applications
u
u
u
u
u
u
u
u
u
u
u
u
Communication equipment
CATV equipment
Test equipment
Data lines
Power supplies
Telecom SLIC protection
Broadband equipment
ADSL equipment, including ADSL2+
XDSL equipment
Satellite and CATV equipment
General telecom equipment
ESD protection
Materials
Dull Tin-plated
Product Marking
Without
Storage and
Operational
Temperature
-40 to +90°C
Weight
~180mg
Climatic category
(IEC 60068-1)
SOCAY Electronics Co., Ltd.
Revision March 6, 2014
AGENCY FILE NUMBER
40/ 90/ 21
www.socay.com
1/4
@SOCAY Electronics Co., Ltd. 2014
Specifications are subject to change without notice.
Please refer to www.socay.com for current information.
Surface Mount 2-Electrode Gas Discharge Tube (GDT)
UN1812 Series
Device Dimensions
(Unit: mm)
Recommended pad outline
Electrical Characteristics
Part Number
DC
Spark-over
Voltage
Maximum Impulse
Spark-over Voltage
Minimum
Insulation
Resistance
Maximum
Capacitance
Arc
Voltage
Nominal
Impulse
Discharge
Current
@1MHz
@1A
@8/20μs
±5 times
@100V/S
@100V/μs
@1KV/μs
UN1812-90CSMD
90V±20%
<600V
<700V
1 GΩ
(at 50V DC)
<1.0pF
~15V
2 KA
UN1812-150CSMD
150V±20%
<600V
<700V
1 GΩ
(at 50V DC)
<1.0pF
~15V
2 KA
UN1812-200CSMD
200V±20%
<600V
<750V
1 GΩ
(at 100V DC)
<1.0pF
~15V
2 KA
UN1812-230CSMD
230V±20%
<600V
<750V
1 GΩ
(at 100V DC)
<1.0pF
~15V
2 KA
UN1812-300CSMD
300V±20%
<800V
<900V
1 GΩ
(at 100V DC)
<1.0pF
~15V
2 KA
UN1812-350CSMD
350V±20%
<800V
<900V
1 GΩ
(at 100V DC)
<1.0pF
~15V
2 KA
UN1812-400CSMD
400V±20%
<900V
<1000V
1 GΩ
(at 100V DC)
<1.0pF
~15V
2 KA
UN1812-470CSMD
470V±20%
<900V
<1000V
1 GΩ
(at 100V DC)
<1.0pF
~15V
2 KA
UN1812-400CSMD+
>400V
<900V
<1000V
1 GΩ
(at 100V DC)
<1.0pF
~15V
2 KA
UN1812-600CSMD
600V±20%
<1100V
<1200V
1 GΩ
(at 100V DC)
<1.0pF
~15V
2 KA
Notes:
1. Terms in accordance with ITU-T K.12 and GB/T 9043-2008
2. At delivery AQL 0.65 level Ⅱ, DIN ISO 2859
SOCAY Electronics Co., Ltd.
Revision March 6, 2014
www.socay.com
2/4
@SOCAY Electronics Co., Ltd. 2014
Specifications are subject to change without notice.
Please refer to www.socay.com for current information.
Surface Mount 2-Electrode Gas Discharge Tube (GDT)
UN1812 Series
Electrical Rating
Item
Test Condition / Description
DC Spark-over Voltage
Impulse Spark-over
Voltage
Insulation Resistance
Capacitance
Requirement
The voltage is measured with a slowly rate of rise dv / dt=100V/s
The maximum impulse spark-over voltage is measured with a rise time of
dv / dt=100V//μs or 1KV/μs
The resistance of gas tube shall be measured each terminal each other terminal,
please see above spec.
The capacitance of gas tube shall be measured each terminal to each other
terminal.
Test frequency :1MHz
The maximum current applying a waveform of 8/20μs that can be applied across
the terminals of the gas tube. One hour after the test is completed, re-testing of the
DC spark-over voltage does not exceed ±30% of the nominal DC spark-over
voltage. Dwell time between pulses is 3 minutes.
I
To meet
the specified
value
1.0
0.9
Nominal Impulse
Discharge Current
0.5
0.1
0.0
8μsec
20μsec
30% Max
T
Recommended soldering profile
Reflow Condition
Pb - Free assembly
-Temperature Min (Ts(min))
TP
Ramp-up
Pre Heat
Critical Zone
TL to TP
Temperature
TL
TS(max)
Ramp-down
TS(min)
200°C
- Time (min to max) (ts)
60 -180 Seconds
3°C/second max
TS(max) to TL - Ramp-up Rate
5°C/second max
- Temperature (TL) (Liquidus)
217°C
- Time (min to max) (ts)
60 -150 Seconds
Peak Temperature (TP)
25
Time to peak temperature
(t 25℃ to peak)
Time
Time within 5°C
Temperature (tp)
SOCAY Electronics Co., Ltd.
Revision March 6, 2014
-Temperature Max (Ts(max))
Average ramp up rate ( Liquidus Temp TL)
to peak
Reflow
Preheat
150°C
260 +0/-5°C
of
actual
peak
10 - 30 Seconds
Ramp-down Rate
6°C/second max
Time 25°C to peak Temperature (TP)
8 minutes Max
Do not exceed
260°C
www.socay.com
3/4
@SOCAY Electronics Co., Ltd. 2014
Specifications are subject to change without notice.
Please refer to www.socay.com for current information.
Surface Mount 2-Electrode Gas Discharge Tube (GDT)
UN1812 Series
Part Numbering
UN1812 – XXX C SMD
SMD,
Surface Mount
8/20μs Level
C, 2KA
Nominal DC Spark-over Voltage
150 = 150V
200 = 200V
350 = 350V
400 = 400V
Series
Tape and Reel Dimensions
Unit: mm
Packaging
Part Number
Description
Quantity
UN1812-XXXCSMD
12mm Tape & 13″ Reel
2500
Cautions and warnings
u
Gas discharge tubes (GDT) must not be operated directly in power supply networks.
u
Gas discharge tubes (GDT) may become hot in case of longer periods of current stress (danger of burning).
u
Gas discharge tubes (GDT) may be used only within their specified values. In the event of overload, the head contacts may
fail or the component may be destroyed.
u
Damaged Gas discharge tubes (GDT) must not be re-used.
SOCAY Electronics Co., Ltd.
Revision March 6, 2014
www.socay.com
4/4
@SOCAY Electronics Co., Ltd. 2014
Specifications are subject to change without notice.
Please refer to www.socay.com for current information.