WCS1600

WCS1600
Hall Effect Base Linear Current Sensor
Features:










Diameter 9.0mm conductor through hole
Output voltage proportional to AC and DC current
Wide sensing current range 0~100A at 5V volt
High sensitivity 20mV/A
Wide operating voltage range 3.0~12 V.
Low operating current 3mA
Isolation voltage 4000V
Ratiometric output from supply voltage
23K Hz Bandwidth
Two bronze sticks for easy soldering on PCB
Functional Description:
The Winson WCS1600 current sensor provides economical and precise
solution for both DC and AC current sensing in industrial, commercial and
communications systems. The unique package provides easy implementation
without breaking original system and makes current sensing possible. Typical
applications include motor control, load detection and management,
over-current fault detection and any intelligent power management system
etc…
The WCS1600 consists of a precise, low-temperature drift linear hall
sensor IC with temperature compensation circuit and a diameter 9.0mm
through hole. Users can use system’s own electric wire by pass it through this
hole to measure passing current. This design allows system designers to
monitor any current path without breaking or changing original system layout
at all. Any current flowing through this hole will generate a magnetic field
which is sensed by the integrated Hall IC and converted into a proportional
voltage.
The terminals of the conductive path are electrically isolated from the
sensor leads. This allows the WCS1600 current sensor to be used in
applications requiring electrical isolation without the use of opto-isolators or
other costly isolation techniques and make system more competitive in cost.
Winson reserves the right to make changes to improve reliability or manufacturability.
©Winson, 2015/5/27
WCS1600
Function Block:
Winson reserves the right to make changes to improve reliability or manufacturability.
©Winson, 2015/5/27
WCS1600
Electrical Characteristics:
Characteristic
Symbol
Supply Voltage
Vdd
Supply Current
Isupply
V0G
Zero Current Vout
Conductor Through Hole
Sensitivity
WCS1600
Bandwidth
BW
WCS1600
Measurable Current Range
Temperature Drift
△Vout
(T=+25˚C, Vdd=5.0V )
Test Conditions
─
Min Typ Max Units
3.0
─
12
V
IP =0 A
─
3.5
6.0
mA
IP =0 A
2.4
─
2.5
8.7
2.6
─
V
mm
IP= +-10 A
17
20
23
mV/A
-
23
-
kHz
Vdd=5V (DC )
-
±100
-
Vdd=5V (AC RMS )
-
70
-
Ip =0 A
-
±0.3
-
A
mV/℃
1.All output-voltage measurements are made with a voltmeter having an input impedance of at least 100kΩ
2. Do not apply any load on output pin, it will degrade IC’s performance.
Package Information:
Winson reserves the right to make changes to improve reliability or manufacturability.
©Winson, 2015/5/27
WCS1600
Characteristic Diagrams:
WCS1600:
Winson reserves the right to make changes to improve reliability or manufacturability.
©Winson, 2015/5/27
WCS1600
Winson reserves the right to make changes to improve reliability or manufacturability.