WCS6800

WCS6800
Hall Effect Base Linear Current Sensor
Features:










11 x 8 mm2 split through hole design
Output voltage proportional to AC and DC current
Wide sensing current range 0~35 A at 5V volt.
High sensitivity 55 mV/A
Wide operating voltage range 3.0~12 V.
Low operating current 3 mA
Isolation voltage 4000 V
Ratiometric output from supply voltage
23 KHz Bandwidth
Two bronze sticks for easy soldering on PCB
Functional Description:
The Winson WCS6800 current sensor provides economical and precise
solution for both DC and AC current sensing in industrial, commercial and
communications systems. New patent design of split through hole provides
easy implementation without breaking original system and makes current
sensing possible. Typical applications include motor control, load detection
and management, over-current fault detection and any intelligent power
management system etc…
The WCS6800 consists of a precise, low-temperature drift linear hall sensor
IC and 11x8 mm2 split through hole. Users can use system’s own electric wire
by pass it through this hole to measure passing current. This design allows
system designers to monitor any current path without breaking or changing
original system layout at all. Any current flowing through this hole will generate
a magnetic field which is sensed by the integrated Hall IC and converted into
a proportional voltage.
The terminals of the conductive path are electrically isolated from the sensor
leads. This allows the WCS6800 current sensor to be used in applications
requiring electrical isolation without the use of opto-isolators or other costly
isolation techniques and make system more competitive in cost.
Winson reserves the right to make changes to improve reliability or manufacturability.
©Winson, 2015/6/2
WCS6800
Function Block:
Winson reserves the right to make changes to improve reliability or manufacturability.
©Winson, 2015/6/2
WCS6800
Electrical Characteristics:
Characteristic
Symbol
Supply Voltage
Vdd
Supply Current
Isupply
Zero Current Vout
Conductor Through Hole
V0G
WCS6800
Bandwidth
BW
Temperature Drift
Test Conditions
─
WCS6800
△Vout
Min Typ Max Units
3.0
─
12
V
─
3.5
6.0
mA
2.35
2.5
2.65
V
─
11x8
─
mm
47
55
63
mV/A
─
─
23
─
kHz
Vdd = 5 V (DC mode)
─
±35
─
Vdd = 5 V (AC rms )
─
25
─
IP = 0 A
─
±1.0
─
IP = 0 A
IP = 0 A (DC mode)
─
Sensitivity
Measurable Current Range
(T=+25˚C, Vdd=5V )
─
IP = ±10 A
A
mV/℃
1. All output-voltage measurements are made with a voltmeter having an input impedance of at least 100kΩ.
2. Do not apply any load on output pin, it will degrade IC’s performance.
Package Information:
Winson reserves the right to make changes to improve reliability or manufacturability.
©Winson, 2015/6/2
2
WCS6800
Characteristic Diagrams:
Winson reserves the right to make changes to improve reliability or manufacturability.
©Winson, 2015/6/2
WCS6800
Application Notice:
There is a linear variation of sensitivity along the y directions. Keep wire as
fixed as possible to get steadiest reading.
Winson reserves the right to make changes to improve reliability or manufacturability.
©Winson, 2015/6/2