ROF-78Exx-0.5 - recom

●
●
●
●
●
Features
INNOLINE
Low Profile 4.5mm
Low Cost
Wide Input Range (5V - 36V)
Short Circuit Protection
Castellated Connections
DC/DC-Converter
with 3 year Warranty
Selection Guide
Part
Number
ROF-78E3.3-0.5SMD*
Input
Range
(VDC)
Output
Voltage
(VDC)
Output
Current
(mA)
Efficiency
5 - 36
3.3
500
73 - 84
500
79 - 87
ROF-78E5.0-0.5SMD*
9 - 36
5.0
* add Suffix „-R“ for tape & reel packing - e.g. ROF78Exx-0.5SMD-R
Non Isolated
Power Module
(%)
Specifications (measured at Ta=25°C, Full Load after Warm-Up)
Input Voltage Range
5 - 36 VDC (12/24V typ)
No Load Input Current
5mA max.
Maximum Input Current
0.5A max.
Short Circuit Input Current
200mA max.
Voltage Accuracy
±5% max.
Line Regulation
(LL to HL at Full Load)
±1% max.
Load Regulation
(10 ~ 100%)
±3% max.
Minimum Load*
ROF-78E
10%
Ripple & Noise
(20MHz Limited)
Transient Response
100% ~ 50% Load
±100mV
(20MHz Limited)
100% ~ 10% Load
±200mV
100mV max.
Operating Frequency
650KHz typ.
ON/OFF Enable Pin
ON: Open or >1.75V
(max. Input Voltage = 5V)
OFF: GND or <0.7V
Current Limit
950mA typ.
Short Circuit Protection
Auto Recovery
Operating Temperature
-40°C ~ 85°C
Storage Temperature
Derating-Graph
(Ambient Temperature)
(Ambient Temperature Vin=24V)
-55°C ~ 125°C
Humidity
95% RH
12.5 x 13.5 x 4.5 mm
Weight
1g
Cooling Method
Free Air Convection
MIL-HDBK-217F
3500 x 10³ hours
*Operation at no load will not damage these devices, but they may not meet all of the datasheet specifications.
Output Power (%)
DImensions (L x W x H)
MTBF (25°C)
RoHS
2011/65/EU
6/6
110
100
90
80
70
60
50
40
30
20
10
20
40
60
80
100
75 85
Operating Temperature (°C)
Refer to Application Notes
www.recom-power.com
REV: 0/2015
I-37
ROF-78Exx-0.5SMD
Series
INNOLINE
DC/DC-Converter
Characteristics
100
90
80
70
60
50
40
30
20
10
0
5V
12V
24V
36V
Efficiency (%)
Efficiency (%)
Efficiency
0
20
40
60
80
100
100
90
80
70
60
50
40
30
20
10
0
9V
12V
24V
36V
0
20
Load (%)
40
60
80
100
Load (%)
ROF-78E3.3-0.5SMD
ROF-78E5.0-0.5SMD
100
90
80
70
60
50
40
30
20
10
0
Ripple (mV)
ROF-78E
Ripple (mV)
Ripple
36V
24V
12V
5V
0
20
40
60
80
100
Load (%)
100
90
80
70
60
50
40
30
20
10
0
36V
24V
12V
9V
0
20
40
60
80
100
Load (%)
ROF-78E3.3-0.5SMD
ROF-78E5.0-0.5SMD
Applications
Standard Application Circuit
Enable Pin
+Vin
ROF-78Exx0.5SMD
-Vin
I-38
+Vo
-Vo
REV: 0/2015
www.recom-power.com
ROF-78Exx-0.5SMD
Series
INNOLINE
DC/DC-Converter
Applications
Application Examples
High efficiency, isolated, dual unregulated outputs
DC/DC Converter (1:1)
ROF-78EXX0.5SMD
+Vin
+Vo
Enable
C1
COM
-Vin
-Vo
*Isolated dual output
*Wide Input Range
Isolated (Up to 6KV), wide input range regulated output
+24V
REC5-4812DRWZ/H6/A/SMD
ROF-78E3.30.5SMD
+Vin
+3.3V
EN
R1
C1
C3
-Vin
ROF-78E
R2
C2
-Vo
*High Isolated voltage
*Improved loading / line regulation
*Wide Input voltage range
*Point-of-Load Architecture
V
Power Sequencing
24V
3.3V
t
Optional Protection Circuit
Schottky
Diode
+Vin
ROF-78EXX0.5SMD
-Vin
Vout
+Vin
Vout=
+Vo - Vsd forward
-Vin
-Vo
Add a blocking diode to Vout if current can flow backwards
into the output, as this can damage the converter when it is
powered down.
www.recom-power.com
ROF-78EXX0.5SMD
Vout
-Vo
The diode can either be fitted across the device if the source is
low impedance or fitted in series with the output.
REV: 0/2015
I-39
ROF-78Exx-0.5SMD
Series
INNOLINE
DC/DC-Converter
Applications
Conduction / Radiation Emission Filter Suggestion
Suggestion for conduction Emission Class A, meet radiation emission Class B
Ls = 33uH
ROF-78EXX0.5SMD
+Vin
+Vo
C2 = 1uF
C1 = 1uF
-Vin
-Vo
The capacitors used are ceramic capacitors, rated voltage 50V
Package Style and Pinning (mm)
ROF-78EXX-0.5SMD
Surface Mount Package
TOP VIEW
12.50
2
13.50
ROF-78E
1
BOTTOM VIEW
3.5
4
2.00
3
1.00
2.00
Recommended Footprint Details
2.50
2.50
0.25
Pin Connections
0.25
Pin #
Out
1
+Vin
2
GND
3
+Vout
4
EN
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
I-40
REV: 0/2015
www.recom-power.com