RAC60-B - recom

●
●
●
●
●
●
●
●
Features
Regulated
Converters
POWERLINE
AC-DC Power Supply
60 Watt PCB Mount Package
Universal Input Voltage Range
4kVAC Isolation RMS
Low Output Ripple and Noise
Short Circuit Protected
Output Trim
UL Certified, CE Marked
AC/DC-Converter
with 3 year Warranty
Compact high power switching power module for PCB mounting.
This switching converter has an universal AC or DC input voltage range
with single high current outputs which are trimmable to compensate for
any voltage drops on the output connections. Threaded inserts ensure
mechanical fixing.
Description
60 Watt
Single
Output
Selection Guide
Part
Number
RAC60-05SB
Input
Range
(VAC)
85-265
Output
Voltage
(VDC)
5
Output
Current
(mA)
10000
Output Efficiency
Max
Power at 230V Capacitive
(W)
%
Load
50
82
80000µF
RAC60-09SB
85-265
9
6600
60
84
28000µF
RAC60-12SB
85-265
12
5000
60
86
14000µF
RAC60-15SB
85-265
15
4000
60
86
12000µF
RAC60-24SB
85-265
24
2500
60
86
4000µF
RAC60-48SB
85-265
48
1250
60
86
950µF
Specifications (typical at 25°C and after warm up time unless otherwise specified )
Input Voltage Range
85-265VAC or 100-370VDC
Rated Power
Input Frequency Range (for AC Input)
47-63Hz
Input Current (full load)
115VAC/230VAC
2A/ 1A max.
No Load Power Consumption
115VAC/230VAC
520mW max.
Inrush Current (<2mS)
115VAC/230VAC
30A/ 50A max.
Leakage Current
Line Voltage Regulation (LL to HL at full load)
RAC60-B
±2%
Single
±1% typ.
Load Voltage Regulation (5% to 100% full load) Single
±1% typ.
Minimum Load
E196683
UL-60950-1 Certified
3.5mA max.
Output Voltage Accuracy (Full load)
1%
Output Noise (20MHz limited)
0.5%Vout + 50mVp-p max
Output Ripple (20MHz limited)
<0.2%Vout + 40mVp-p max
Output Trim
±10%
Operating Frequency
Derating-Graph
(Ambient Temperature)
100kHz typ.
Efficiency at Full Load
see table
Temperature Coefficient
±0.02%/°C typ.
Isolation Resistance
100 MOhm max.
Short Circuit Protection
Continuous, Hiccup, Automatic Restart
Over Voltage Category
OVC II
Operating Temperature Range
free air convection, with derating
Storage Temperature Range
-40°C to +70°C
-40°C to +85°C
Humidity
95% RH max.
Case Material
125
4kVAC / 1 minute
Plastic Resin with Fibreglass (UL94V-0)
Package Weight
310g
Packing Quantity
1 pc
Natural
Convection
100
Output Power (%)
RMS Isolation Voltage (input to output)
EMC
RoHS
2011/65/EU
6/6
60 Watts max.
75
60
50
62.5% (24V/48V)
50% (12V/15V)
25
25% (5V/9V)
0
-40 -20
-30
0
60 70 80
45 50 55
Ambient Temperature Range (°C)
EN 55011 Class B / EN 55022 Class B / EN 60601-1-2/ EN61000-3-2 -3
EN 55024 / EN61000-4-2 -3 -4 -5 -6 - 8 -11
MTBF (using MIL-HDBK-217F, 25°C)
www.recom-power.com
>130 x 10³ hours
REV: 0/2015
Refer to Application Notes
PA-55
RAC60-SB
Series
POWERLINE
AC/DC-Converter
Package Style and Pinning
109.0
58.5
30.0
6.00
1.8
6.1
96.32
1.2
Pin Connections – Single Output
6.1
13.70
13.82
Bottom View
1
4
19.05
10.16
Pin #
8.90
5
6
2
5.08
mounting
inserts
46.3
M3
Threaded
Insert
x4
3
Dia.(mm)
Function
1
1.2
FG
2
1.8
VAC in (L)
3
1.8
VAC in (N)
4
1.2
Trim
5
1.8
-VDC Out
6
1.8
+VDC Out
5.85
mounting inserts 97.3
Tolerance ± 0.5 mm
RAC60-B
Output Trim Adjustment
-Vout
-Vout
Trim Up
10kW
Trimpot
Trim
10kW
Trimpot
Trim
Trim Down
10kW
Trimpot
+Vout
+Vout
Standard Application Circuit
Suggested fuse rating
L
4A Slow Blow
N
Fuse
VACin (L)
Vout+
C1(Optional)
0.1uF
25V
VACin (N)
C2(Optional)
47uF
50V
Load
Vout-
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
PA-56
REV: 0/2015
www.recom-power.com