KEMA HIGH-VOLTAGE LABORATORY SUMMARY Order no

KEMA HIGH-VOLTAGE LABORATORY
Order no.: 70970101
SUMMARY
CLIENT
Sixnet, LLC
Ballston Lake, NY, United States of America
SUMMARY OF TEST REPORT NO.
09-1461
MATERIAL TESTED
Manufacturer
Sixnet, LLC
Ballston Lake, NY, United States of America
Industrial ethernet switch
EL228
Object description
Type
Sample data
Serial number
Software version
Variant
EL228 EUT 1
934000407
-EL228 EUT 2
934000384
-EL228-AA-1 Unit 2
--Vaux = 85 - 264 VAC; 90-300 VDC
24 10/100 Mbps SM / MM, ST / SC fiber optic interface ports
4 1 Gbps electrical / optical ports
Hardware version
----
The test samples are selected such that they represent the complete product type since testing all
possible hardware and software variants will be impossible. The results apply only to the objects
tested. The responsibility for conformity of any object having the same designations with that tested
rests with the Manufacturer.
TEST PROGRAMME
Environmental tests according IEC 61850-3 and IEEE 1613:
- EMC requirements (IEC 61000-4 series, IEC 61000-6-2, IEC 61000-6-4, IEC 61000-6-5,
IEEE C37.90 series);
- Climatic environmental requirements (IEC 60068 series);
- Mechanical requirements (IEC 60068 series and IEEE 1613);
- Dielectric requirements (IEC 60255-5 and IEEE 1613).
DATE AND PLACE OF THE TESTS
From 1 October 2009 until 7 January 2010 in the KEMA High-Voltage Laboratory, Arnhem,
the Netherlands.
-2-
PERSONS ATTENDING THE TESTS (partly)
Mr A. Hilberink
THE TESTS WERE CARRIED OUT BY
Mr H.C. Koerts
Order no.: 70970101
Sixnet
Hellendoorn, the Netherlands
KEMA High-Voltage Laboratory,
Arnhem, the Netherlands
SUMMARY AND CONCLUSION
The results obtained relate only to the work ordered and the material tested.
Electromagnetic compatibility
test
standard
test level / test details
electrostatic discharges
IEC 61000-4-2
IEEE 1613, class 1
8 kV contact, 15 kV air
Remark: power / output contact
connector not tested.
electromagnetic fields
IEC 61000-4-3
IEEE 1613 class 2
80 MHz – 1 GHz; AM 80% 1kHz and
pulse 100% 1 Hz (keying)
20 V/m prior to modulation,
1400 MHz – 2700 MHz, AM 80%,
1 kHz, 10 V/m prior to modulation
fast transients
IEC 61000-4-4
IEEE 1613, class 1
4 kV
surges
IEC 61000-4-5
4 kV LL, 2 kV LE
conducted RF immunity
IEC 61000-4-6
150 kHz – 80 MHz; AM 80% 1kHz
10 V
PF magnetic fields
IEC 61000-4-8
100 A/m continuous
1000 A/m 3 seconds
100 kHz oscillatory magnetic
field
IEC 61000-4-10
30 A/m
1 MHz oscillatory magnetic
field
IEC 61000-4-10
30 A/m
voltage dips, short interruptions
and voltage variations
IEC 61000-4-11
IEEE 1613
50 to 1000 ms interruption (
details in report).
40% residual voltage; 200 ms
70% residual voltage; 500 ms.
5 seconds interruption.
Gradual shut down / start-up (DC).
Reversed polarity (DC).
ripple on DC power supply
IEEE 1613
5%
100 kHz oscillatory waves
IEC 61000-4-18
2,5 kV CM; 2,5 kV DM
1 MHz oscillatory waves
IEC 61000-4-18
IEEE 1613, class 2
2,5 kV CM; 2,5 kV DM
-3-
Order no.: 70970101
Climatic environmental conditions
test
standard
test level / test details
operating
IEC 60721-3-3
IEC 60068-2-6
IEEE 1613, class 2
-40 °C - +70 °C
storage
IEC 60721-3-3
IEC 60068-2-6
IEEE 1613
-40 °C - +85 °C
humidity
IEC 60721-3-3
IEC 60068-2-78
IEEE 1613, class 2
95% / +40 °C
96 hours
Mechanical environmental conditions
test
standard
test level / test details
stationary vibration
IEC 60721-3-3
IEC 60068-2-6
class 3M6
shock
IEC 60721-3-3
IEC 60068-2-27
class 3M6
free fall
IEC 60870-2-2
IEC 60068-2-31
IEEE 1613
class Cm
250 mm
static load
IEC 60870-2-2
IEC 60721-3-3
class Cm, 5 kPa
class 3M6
seismic
IEC 60255-21-3
class 2
IEC 60255-5
IEEE 1613
2 kV
0,5 kV (communication ports)
IEC 60255-5
IEEE 1613
5 kV
Dielectric tests
PF voltage withstand
impulse voltage
-4-
Order no.: 70970101
The tests were passed.
IEEE 1613 performance class 1: communication errors or interruption during tests, automatic recovery
IEEE 1613 performance class 2: without communication errors or interruption during the test.
KEMA Nederland B.V.
S.A.M. Verhoeven
KEMA High-Voltage Laboratory
Arnhem, 11 January 2010