Datasheet / More Information

MIL318 IP67 Industrial Ethernet Switch
Sixnet Military Series
Military-Rated Gigabit Industrial Connectivity
Red Lion’s Sixnet MIL318 has 12 Gigabit (10/100/1000) plus
4 additional Gigabit (1,000 Mbps, copper or fiber) plus 2 x
10G (10,000 Mbps, fiber) ports.
This Layer 3 managed industrial Ethernet switch features military-style D38999 connectors and link
speeds of 10Mb/s to 10Gb/s. With an ultra-rugged case, protected circuitry and advanced software,
this switch offers an ideal Commercial Off-The-Shelf (COTS) military solution for battlefield
communications, combat vehicles and avionics shipboard.It can also be used with industrial
applications that require hardened switches.
APPLICATIONS
>> Industrial outdoors
>> Marine and maritime
>> Transportation
Driver Vision Enhancement
Acoustic Gun Fire Detection
Cameras
Remote Weapon
Mission Computer
Radio Kits
>> Military in-vehicle (per COTS)
>> Aerospace
PRODUCT HIGHLIGHTS
>> L
ayer 3 Ethernet switch increases multi-service
network performance
>> IPv4 and IPv6 management
>> IP67/NEMA 6 rated package protects against dust,
water, oil, debris and more
>> H
igh-performance switch rated for MIL-STD-810G,
MIL-STD-461F and MIL-STD-1275D
>> M
ilitary-rated MIL-DTL-38999 Series III connectors
protect against vibration, shock, water and more
>> Tough corrosion-proof aluminum case
GPS Receiver
MIL318
Military-Rated Gigabit Industrial Connectivity Features
ENHANCED SECURITY
Red Lion’s Sixnet MIL318 provides enhanced
security features for connectivity and access
control, including ACLs, authentication and portlevel security with IEEE 802.1X. Access Control
Lists (ACLs) can be used to restrict access to
sensitive network resources by denying packets
based on L2/L3/L4 headers. SSH and RADIUS
authentication protect data communications and
ensure data privacy. IEEE 802.1X port-based
access control ensures dynamic, port-based
security and user authentication for network
access. IP source guard prevents a malicious
user from spoofing or taking over another user’s
IP address by creating a binding table between
client’s IP and MAC address, port and VLAN.
ADVANCED ROUTING
Red Lion’s Sixnet MIL318 supports hardwarebased IPv6 and IPv4 routing for maximum
performance. The switches provide a seamless
migration path from IPv4 to IPv6 for future
network upgrades and investment protection.
Advanced routing protocols such as RIP and
OSPF provide dynamic routing by exchanging
routing information with other Layer 3 switches
or routers. Multicast routing is supported under
independent multicast protocols, including PIMDM and PIM-SM.
COMPREHENSIVE QoS
Red Lion’s Sixnet MIL318 offers advance QoS for
marking, classification and scheduling to deliver
best-in-class performance for data, voice and
video traffic at wire speed. Eight egress queues
per port enable differentiated management
of up to eight traffic types across the stack.
Traffic is prioritized according to 802.1p, DSCP,
IP precedence and TCP/UDP port number to
provide optimal performance for
real-time applications. Weighted Round Robin
(WRR) and strict priority ensure differential
prioritization of packet flows and avoid
congestion of ingress and egress queues. With
bidirectional rate-limiting, per port or traffic class,
the MIL318 preserves network bandwidth and
allows full control of network resources.
Layer 2
• Spanning Tree Protocol (STP per IEEE
802.1D) plus
– IEEE 802.1w Rapid Spanning Tree Protocol
(RSTP)
– IEEE 802.1s Multiple Spanning Tree
Protocol (MSTP)
– Loopback detection
– Auto edge port
– BPDU filter/guard
• Virtual Local Area Network (VLAN)
– IP subnet based VLAN
– Private VLAN isolated
– Private VLAN
–GVRP/GARP
– 802.1v protocol
– Voice VLAN
– VLAN translation
– IPv6 VLANs
– VLAN trunking
• Jumbo Frame: 9K
• IGMP Snooping v1/v2/v3
• Select Q-in-Q
Layer 3
• Host table: 8K
• Route table: 8K
• Static route table: 512
• Multicast table: 1K
• Unicast routing
– Static unicast routes
– RIP v1/v2
–OSPF
–BGP
• Multicast routing
–PIM-DM
–PIM-SM
– IGMP v1/v2/v3
– IGMP v3 proxy
• IP redundancy
• Proxy ARP
• UDP Helper
Switch Properties
• Ethernet Ports:
– 12 x 10/100/1000 Mbps (copper)
– 4 x 1000 Mbps (copper or fiber)
– C = Copper link up to 100m
– M = 850nm; multimode; up to 300m
– S = 1310nm; singlemode; up to 6km
– Other options available
– 2 x 10G 10,000 Mbps (fiber)
– M = 850nm; multimode; up to 180m
– S = 1310nm; singlemode; up to 6km
– Other options available
• Switching capacity: 128 Gbps/176 Gbps
• Forwarding Rate: 95.2 Mpps/130.9 Mpps
• MAC Address Table Size: 16K
• Packet Buffer Size: 2 MB
Security
• Port security
• IP Source Guard
• Supports IEEE 802.1X port-based and
MAC-based access control
• IP filter configuration for management
interface (SNMP, Telnet, Web)
• RADIUS authentication
• Access Control List
•
•
•
•
•
SSH v2
HTTPS/SSL
MAC filter
Dynamic ARP Inspection
Link detection package protection
Management
• Switch Management
– CLI via console port or Telnet
– Web management
– SNMP v1, v2c, v3
– IGMP snooping (v1/v2)
• Firmware and Configuration:
– CLI via console port or Telnet
– Web management
– SNMP v1, v2c, v3
– IGMP snooping (v1/v2)
• Supports RMON (groups 1, 2, 3 and 9)
• Supports BOOTP, DHCP for IP address
assignment
• DHCP Snooping
• DHCP option 66, 67
• Supports SNTP
• Supports event/error log, system log
• Cable diagnostics
• ATC traffic control
• Delay reload
• sFlow
• CPU Process Utilization
• Cable Diagnostic
• IP Clustering
• Port Mirroring
QoS
• Priority Queues: 8 hardware
queues per port
• Traffic classification based on
IEEE 802.1p CoS, IP Precedence,
DSCP, TCP/UDP port number,
ACL and marking
• DiffServ
• Supports WRR and strict priority
• Port rate limiting
IPv6
• IPv4/IPv6 Dual Protocol Stack
• IPv6 Address Types: Unicast, Multicast
• ICMPv6
• ICMPv6 Redirect
• IPv6 Path MTU Discovery
• IPv6 Neighbor Discovery
• SNMP over IPv6
• HTTP over IPv6
• SSH over IPv6
• Support IPv6 Telnet
• Support IPv6 DNS Resolver
• Support IPv6 syslog
• Support IPv6 SNTP
• Support IPv6 TFTP
• Remote IPv6 ping
• Ping over IPv6
• Trace route over IPv6
• IPv6 DHCP relay
• sFlow over IPv6
• IPv6 ACL
• IPv6 DiffServ
• PIM-DMv6
• PIM-SMv6
• MVRv6
Military-Rated Gigabit Industrial Connectivity Specifications
SNMP & Ethernet Standards
• Ethernet, Fast Ethernet, Gigabit Ethernet
• Full-duplex flow control
• IEEE 802.3-2005
• IEEE 802.3ae 10 Gigabit Ethernet
• IEEE 802.3D Spanning Tree Protocol
• IEEE 802.1w Rapid Spanning Tree Protocol
• IEEE 802.1s Multiple Spanning Tree Protocol
• IEEE 802.1Q Virtual LAN
• IEEE 802.1X IEEE8021-PAE-MIB
• RFC 1907 SNMPv2-MIB (MIB-II)
• RFC 2011 IP-MIB (MIB-II)
• RFC 2012 TCP-MIB (MIB-II)
• RFC 2013 UDP-MIB (MIB-II)
• RFC 1493 Bridge MIB
• RFC 2863 IF-MIB
• RFC 2819 RMON MIB
• RFC 2618 RADIUS MIB
• RFC 2665 Etherlike MIB
• RFC 2737 Entity MIB
• RFC 2674 P-bridge, Q-bridge
• V-Bridge MIB
• RFC 3036 MAU MIB
• RFC 1612 DNS Reslover MIB
• RFC 3411 SNMP Framework
• RFC 3412 SNMP MPD MIB
• RFC 3413 SNMP Target MIB, SNMP Notify MIB
• RFC 3415 SNMP View-Based ACM MIB
• SNMP Trap Supported:
• RFC 1215, 1907, 2863, 1493, 1757, 2819
• Private MIB
Environmental
• MIL-STD-810G and MIL-STD-108E for environmental performance
(see table)
• Operating temperature: -40 to +70° C
(cold startup at -5° C)
• Storage temperature: -40 to +85° C
• Humidity: 5 to 95% RH (non-condensing
• Vent plug for high-altitude operation
EMC
• MIL-STD-461F for EMI performance. CE101, CE102, RE102 (see table)
• MIL-STD-461F for EMC performance. CS101, CS114, CS115, CS116,
RS101, RS103 (see table)
• MIL-STD-704 A/E/F and MIL-STD-1275 A/B/D for power protection
(POWER INPUT)
Recommended Interface Plugs
• 1G Ethernet Plug: Aero AE90-365-BN9-9PN
• 1G and 10G Ethernet Fiber Plug: TE/Deutsch MC406E-N-09-2SN
• Power Plug: D38999/26xA98SA (x = plating option)
• RS232 Plug: D38999/26xA35PA (x = plating option)
• Contact distributor for mating connectors
Warranty
• 5 years on design and manufacturing defects
Power Input
• Input voltage range: 18-36 VDC (continuous)
• Input power: 50 W (estimated max. under full load)
• Reverse polarity protection
• MIL-STD-1275 for power protection
• Surge protection: 100 volts for 1 second
• Transient protection: 15,000 watts peak
• Spike protection: 5,000 watts (10x for 10 uS) or 250 volts
(50x for 100 uS)
Physical
• Dimensions (L x W x H): 13x8.5x4.25”
• Weight (including caps): 12 lbs
• IP67 dust, oil and water-tight package protection
• LED indicators: port, uplink, system, diagnostic
• Tough corrosion proof aluminum case
• Conductive cooling — no moving parts
All specifications are subject to change. Contact Red Lion to learn more
Military-Rated Gigabit Industrial Connectivity Specifications
ORDERING GUIDE
PART NUMBER
MIL318-YYYY-XX*
DIMENSIONS
DESCRIPTION
18 port IP67 managed L3 Ethernet switch: 12 copper Gig ports, 4 Gig
ports for either copper, mulitimode or singlemode fiber, and 2 10G ports for
mulitimode or singlemode fiber**
ET-CAT6M-XCG
Cordset, 1G Ethernet plug to RJ45, x=meters
ET-MILPWR-C2
Cordset, power plug to leads, 2 meters
ET-MIL232-C2NU
Cordset, military-style plug to RS232 console port, 2 meters
Note: See separate datasheet for cable specs. Contact Red Lion for other cordset and cable options.
* Y= C (copper), M (multimode fiber), S (singlemode fiber) Gigabit speed
X= M (multimode fiber), S (singlemode fiber) 10 Gigabit speed
** Contact Red Lion for fiber options
EMI & EMC
TEST
STANDARD
SPECIFICATION
Conducted Emissions
MIL-STD-461F
CE101: Power Leads, 30Hz to 10Hz
Conducted Emissions
MIL-STD-461F
CE102: Power Leads, 10 kHz to 10 MHz
Radiated Emissions
MIL-STD-461F
RE102: Electric Field, 2 MHz to 18 GHz
Conducted Susceptibility
MIL-STD-461F
CS101: Power Leads, 30 Hz to 150 kHz
Conducted Susceptibility
MIL-STD-461F
CS114: Bulk Cable Injection, 10 kHz to 200 MHz
Conducted Susceptibility
MIL-STD-461F
CS115: Bulk Cable Injection, Impulse Excitation
Conducted Susceptibility
MIL-STD-461F
CS116: Damped Sinusoidal Transients,
Cables and Power Leads, 10 kHz to 100 MHz
Radiated Susceptibility
MIL-STD-461F
RS101: Electric Field, 30 Hz to 100 kHz
Radiated Susceptibility
MIL-STD-461F
RS103: Electric Field, 2 MHz to 40 GHz (50V/m)
Ripple Test
MIL-STD-1275D
2 V Peak and 7 V Peak Ripple Test
Spike Test (Imported)
MIL-STD-1275D
+/- 250 Volt Imported Spike Test
Spike Test (Exported)
MIL-STD-1275D
Voltage Spike Exported from the EUT
Surge Test
MIL-STD-1275D
40 V and 100 V Surges
ENVIRONMENTAL
TEST
STANDARD
SPECIFICATION
Operating Temperature
MIL-STD-810G
Methods 501.5: Operating Temperature
Temperature Shock
MIL-STD-810G
Method 503.5: Temperature Shock
Humidity
MIL-STD-810G
Method 507.5: Humidity
Elevation
MIL-STD-810G
Method 500.5: Elevation
Functional Shock
MIL-STD-810G
Method 516.6: Functional Shock
General Vibration
MIL-STD-810G
Method 514.6, Proc. 1: General Vibration
Steam and Water Jet
MIL-STD-108E
Paragraph 4.10 Table II: Steam and Water Jet
Leakage (Immersion)
MIL-STD-810G
Method 512.5: Leakage (Immersion)
Salt and Fog
MIL-STD-810G
Method 509.5
Dust
MIL-STD-810G
Method 510.5 Proc. 1
Explosive Atmosphere
MIL-STD-810G
Method 511.5
Acceleration Test
MIL-STD-810G
Method 513.6 Proc. 1,2,3
Americas
[email protected]
w w w. re d l i o n . n e t
Europe
Middle East
Africa
[email protected]
As the global experts in communication, monitoring and control for
industrial automation and networking, Red Lion has been delivering
innovative solutions for over forty years. Our award-winning
technology enables companies worldwide to gain real-time data
visibility that drives productivity. Product brands include Red Lion,
N-Tron and Sixnet. With headquarters in York, Pennsylvania, the
company has offices across the Americas, Asia-Pacific and Europe.
For more information, please visit www.redlion.net. Red Lion is a
Spectris company.
Connect. Monitor. Control.
+1 (717) 767-6511
ADLD0193 102913 ©2013 Red Lion Controls
Asia-Pacific
[email protected]