MIL312 IP67 Industrial Ethernet Switch Sixnet Military Series Military-Rated Gigabit Industrial Connectivity Red Lion’s Sixnet MIL312 has 12 Gigabit (10/100/1000) Ethernet copper ports. This Layer 3 managed industrial Ethernet switch features military-style D38999 connectors and link speeds of 10/100/1000 Mbps. With an ultra-rugged case, protected circuitry and advanced software, this switch offers an ideal Commercial Off-The-Shelf (COTS) military solution for battlefield communications, combat vehicles and avionics shipboard. It can also be used with industrial applications that require hardened switches. APPLICATIONS >> Industrial outdoors >> Marine and maritime >> Transportation Driver Vision Enhancement Acoustic Gun Fire Detection Cameras Remote Weapon Mission Computer Radio Kits >> Military in-vehicle >> Aerospace PRODUCT HIGHLIGHTS >> L ayer 3 Ethernet switch increases multi-service network performance >> IPv4 and IPv6 management GPS Receiver >> IP67/NEMA 6 rated package protects against dust, water, oil, debris and more >> H igh-performance switch rated for MIL-STD-810G, MIL-STD-461F and MIL-STD-1275D >> M ilitary-rated MIL-DTL-38999 Series III connectors protect against vibration, shock, water and more >> Tough corrosion-proof aluminum case MIL312 Military-Rated Gigabit Industrial Connectivity Features ENHANCED SECURITY Red Lion’s Sixnet MIL312 provides enhanced security features for connectivity and access control, including Access Control Lists (ACL), authentication and port-level security with IEEE 802.1X. ACL can be used to restrict access to sensitive network resources by denying packets based on L2/L3/L4 headers. SSH and RADIUS authentication protect data communications and ensure data privacy. IEEE 802.1X port-based access control ensures dynamic, port-based security and user authentication for network access. IP source guard prevents a malicious user from spoofing or taking over another user’s IP address by creating a binding table between client IP and MAC address, port and VLAN. ADVANCED ROUTING Red Lion’s Sixnet MIL312 supports hardwarebased IPv6 and IPv4 routing for maximum performance. The switches provide a seamless migration path from IPv4 to IPv6 for future network upgrades and investment protection. Advanced routing protocols such as RIP and OSPF provide dynamic routing by exchanging routing information with other Layer 3 switches or routers. Multicast routing is supported under independent multicast protocols, including PIMDM and PIM-SM. COMPREHENSIVE QoS Red Lion’s Sixnet MIL312 offers advanced QoS for marking, classification and scheduling to deliver best-in-class performance for data, voice and video traffic at wire speed. Eight egress queues per port enable differentiated management of up to eight traffic types across the stack. Traffic is prioritized according to 802.1p, DSCP, IP precedence and TCP/UDP port number to provide optimal performance for realtime applications. Weighted Round Robin (WRR) and strict priority ensure differential prioritization of packet flows and avoid congestion of ingress and egress queues. With bidirectional ratelimiting, per port or traffic class, the MIL312 preserves network bandwidth and allows full control of network resources. Layer 2 • Spanning Tree Protocol (STP per IEEE 802.1D) plus – IEEE 802.1w Rapid Spanning Tree Protocol (RSTP) – IEEE 802.1s Multiple Spanning Tree Protocol (MSTP) – Loopback detection – Auto edge port – BPDU filter/guard • Virtual Local Area Network (VLAN) – IP subnet based VLAN – Private VLAN isolated – Private VLAN –GVRP/GARP – 802.1v protocol – Voice VLAN – VLAN translation – IPv6 VLANs – VLAN trunking • Jumbo Frame: 9K • IGMP Snooping v1/v2/v3 • Select Q-in-Q Layer 3 • Host table: 8K • Route table: 8K • Static route table: 512 • Multicast table: 1K • Unicast routing – Static unicast routes – RIP v1/v2 –OSPF –BGP • Multicast routing –PIM-DM –PIM-SM – IGMP v1/v2/v3 – IGMP v3 proxy • IP redundancy • Proxy ARP • UDP Helper Switch Properties • Ethernet Ports: 12 x 10/100/1000 Mbps (copper) • Switching capacity: 128 Gbps/176 Gbps • Forwarding Rate: 95.2 Mpps/130.9 Mpps • MAC Address Table Size: 16K • Packet Buffer Size: 2 MB Security • Port security • IP Source Guard • Supports IEEE 802.1X port-based and MAC-based access control • IP filter configuration for management interface (SNMP, Telnet, Web) • RADIUS authentication • Access Control List • SSH v2 • HTTPS/SSL • MAC filter • Dynamic ARP Inspection • Link detection package protection Management • Switch Management – CLI via console port or Telnet – Web management – SNMP v1, v2c, v3 – IGMP snooping (v1/v2) • Firmware and Configuration: – CLI via console port or Telnet – Web management – SNMP v1, v2c, v3 – IGMP snooping (v1/v2) • Supports RMON (groups 1, 2, 3 and 9) • Supports BOOTP, DHCP for IP address assignment • DHCP Snooping • DHCP option 66, 67 • Supports SNTP • Supports event/error log, system log • Cable diagnostics • ATC traffic control • Delay reload • sFlow • CPU Process Utilization • Cable Diagnostics • IP Clustering • Port Mirroring QoS • Priority Queues: 8 hardware queues per port • Traffic classification based on IEEE 802.1p CoS, IP Precedence, DSCP, TCP/UDP port number, ACL and marking • DiffServ • Supports WRR and strict priority • Port rate limiting IPv6 • IPv4/IPv6 Dual Protocol Stack • IPv6 Address Types: Unicast, Multicast • ICMPv6 • ICMPv6 Redirect • IPv6 Path MTU Discovery • IPv6 Neighbor Discovery • SNMP over IPv6 • HTTP over IPv6 • SSH over IPv6 • Support IPv6 Telnet • Support IPv6 DNS Resolver • Support IPv6 syslog • Support IPv6 SNTP • Support IPv6 TFTP • Remote IPv6 ping • Ping over IPv6 • Trace route over IPv6 • IPv6 DHCP relay • sFlow over IPv6 • IPv6 ACL • IPv6 DiffServ • PIM-DMv6 • PIM-SMv6 • MVRv6 Military-Rated Gigabit Industrial Connectivity Specifications SNMP & Ethernet Standards • Ethernet, Fast Ethernet, Gigabit Ethernet • Full-duplex flow control • IEEE 802.3-2005 • IEEE 802.3D Spanning Tree Protocol • IEEE 802.1w Rapid Spanning Tree Protocol • IEEE 802.1s Multiple Spanning Tree Protocol • IEEE 802.1Q Virtual LAN • IEEE 802.1X IEEE8021-PAE-MIB • RFC 1907 SNMPv2-MIB (MIB-II) • RFC 2011 IP-MIB (MIB-II) • RFC 2012 TCP-MIB (MIB-II) • RFC 2013 UDP-MIB (MIB-II) • RFC 1493 Bridge MIB • RFC 2863 IF-MIB • RFC 2819 RMON MIB • RFC 2618 RADIUS MIB • RFC 2665 Etherlike MIB • RFC 2737 Entity MIB • RFC 2674 P-bridge, Q-bridge • V-Bridge MIB • RFC 3036 MAU MIB • RFC 1612 DNS Reslover MIB • RFC 3411 SNMP Framework • RFC 3412 SNMP MPD MIB • RFC 3413 SNMP Target MIB, SNMP Notify MIB • RFC 3415 SNMP View-Based ACM MIB • SNMP Trap Supported: • RFC 1215, 1907, 2863, 1493, 1757, 2819 • Private MIB Environmental • MIL-STD-810G and MIL-STD-108E for environmental performance (see table) • Operating temperature: -40 to +75° C (cold startup at -40° C) • Storage temperature: -40 to +85° C • Humidity: 5 to 95% RH (non-condensing • Vent plug for high-altitude operation EMC • MIL-STD-461F for EMI performance. CE101, CE102, RE102 (see table) • MIL-STD-461F for EMC performance. CS101, CS114, CS115, CS116, RS101, RS103 (see table) • MIL-STD-704 A/E/F and MIL-STD-1275 A/B/D for power protection (POWER INPUT) Recommended Interface Plugs • Ethernet Plug: Aero AE90-365-BN9-9PN • Power Plug: D38999/26xA98SA (x = plating option) • RS232 Plug: D38999/26xA35PA (x = plating option) • Contact distributor for mating connectors Warranty • 5 years on design and manufacturing defects Power Input • Input voltage range: 18-36 VDC (continuous) • Input power: 35 W (estimated max. under full load) • Reverse polarity protection • MIL-STD-1275 for power protection • Surge protection: 100 volts for 1 second • Transient protection: 15,000 watts peak • Spike protection: 5,000 watts (10x for 10 uS) or 250 volts (50x for 100 uS) Physical • Dimensions (L x W x H): 13x6x3.75” • Weight (including caps): 8.5 lbs • IP67 dust, oil and water-tight package protection • LED indicators: port, uplink, system, diagnostic • Tough corrosion proof aluminum case • Conductive cooling — no moving parts All specifications are subject to change. Contact Red Lion to learn more Military-Rated Gigabit Industrial Connectivity Specifications DIMENSIONS ORDERING GUIDE PART NUMBER 2.74" [6.97cm] DESCRIPTION MIL312-1 12 port Gigabit IP67 managed Layer 3 Ethernet switch ET-CAT6M-XCG Cordset, 1G Ethernet plug to RJ45, x=meters ET-MILPWR-C2 Cordset, power plug to leads, 2 meters ET-MIL232-C2NU Cordset, military-style plug to RS232 console port, 2 meters 2 Note: See separate datasheet for cable specs. Contact Sixnet for other cordset and cable options. EMI & EMC TEST Gig Ports 1 Vent Console 3 4 STANDARD SPECIFICATION Conducted Emissions MIL-STD-461F CE101: Power Leads, 30Hz to 10Hz Conducted Emissions MIL-STD-461F CE102: Power Leads, 10 kHz to 10 MHz Radiated Emissions MIL-STD-461F RE102: Electric Field, 2 MHz to 18 GHz Conducted Susceptibility MIL-STD-461F CS101: Power Leads, 30 Hz to 150 kHz Conducted Susceptibility MIL-STD-461F CS114: Bulk Cable Injection, 10 kHz to 200 MHz Conducted Susceptibility MIL-STD-461F CS115: Bulk Cable Injection, Impulse Excitation Conducted Susceptibility MIL-STD-461F CS116: Damped Sinusoidal Transients, Cables and Power Leads, 10 kHz to 100 MHz Radiated Susceptibility MIL-STD-461F RS101: Electric Field, 30 Hz to 100 kHz Radiated Susceptibility MIL-STD-461F RS103: Electric Field, 2 MHz to 40 GHz (50V/m) Ripple Test MIL-STD-1275D 2 V Peak and 7 V Peak Ripple Test Spike Test (Imported) MIL-STD-1275D +/- 250 Volt Imported Spike Test Spike Test (Exported) MIL-STD-1275D Voltage Spike Exported from the EUT Surge Test MIL-STD-1275D 40 V and 100 V Surges TEST STANDARD SPECIFICATION Operating Temperature MIL-STD-810G Methods 501.5: Operating Temperature Temperature Shock MIL-STD-810G Method 503.5: Temperature Shock Humidity MIL-STD-810G Method 507.5: Humidity Elevation MIL-STD-810G Method 500.5: Elevation Functional Shock MIL-STD-810G Method 516.6: Functional Shock General Vibration MIL-STD-810G Method 514.6, Proc. 1: General Vibration Steam and Water Jet MIL-STD-108E Paragraph 4.10 Table II: Steam and Water Jet Leakage (Immersion) MIL-STD-810G Method 512.5: Leakage (Immersion) Salt and Fog MIL-STD-810G Method 509.5 Dust MIL-STD-810G Method 510.5 Proc. 1 Explosive Atmosphere MIL-STD-810G Method 511.5 Acceleration Test MIL-STD-810G Method 513.6 Proc. 1,2,3 ENVIRONMENTAL Americas [email protected] 5 6 13.0" [33.02cm] 7 8 9 10 11 12 Power 6.0" [15.24] 3.75" [9.54cm] w w w. re d l i o n . n e t Europe Middle East Africa [email protected] As the global experts in communication, monitoring and control for industrial automation and networking, Red Lion has been delivering innovative solutions for over forty years. Our award-winning technology enables companies worldwide to gain real-time data visibility that drives productivity. Product brands include Red Lion, N-Tron and Sixnet. With headquarters in York, Pennsylvania, the company has offices across the Americas, Asia-Pacific and Europe. For more information, please visit www.redlion.net. Red Lion is a Spectris company. Connect. Monitor. Control. +1 (717) 767-6511 ADLD0190 103113 ©2013 Red Lion Controls Asia-Pacific [email protected]