Gas Tube Surge Arresters and Switching Spark Gaps :

Gas Tube Su rge Arresters and Switching Spark Gaps :
Application
The main application of Gas-filled surge arresters is in over - voltage protection of
telecommunication installation ranging from MDF in exchanges to end equipment at subscribers.
With the increase in use of computers, facsimiles and modems, the ceramic arrester can not only
offer optimum protection in over-voltage for them but also for the cable television with its extensive
cabling and sophisticated amplifiers.
1. The Example Of Application :
A. Telephone / FAX / Modem protection
230V / 350V Arrester
Two 2-electrode arresters
One 3-electrode arrester
Telephone/fax/modem protection
Telephones ,faxes and modems are increasingly being equipped with sophisticated
electronics .Typical circuits used to protect them with surge arresters are shown in
Fig.1.In the event of an overvoltage ,the arrester protects both exchange lines by
conducting the surge current away to ground.
B. Signal Line Protection
Typical: 75V/ 90V/ 230V Arrester
A2-electrode arrester
Signal line protection
Signal circuits are often run with no ground conductor .A 2-electrode arrester
circuit located between the two signal lines prevents the formation of large
potential differences at the input of the equipment to be protected before they can
cause any damage
C. AC Line Protection
Typical:
270V
Arrester/for 110Vac
470V
Arrester/for 220Vac
600V
Arrester/for 220Vac
800V
Arrester/for 400Vac
Line
Varistor
Neutral
Arrester
●
Ground
AC line protection
Telecommunications installations as well as CATV amplifiers ,CB
transmitters ,home entertainment systems ,computers and similar equipment can
be exposed to voltage surges conducted via the power network .The combination
of a surge arrester and a varistor offers proven protection in these cases .The phase
and neutral conductors are connected to ground potential of both protection
elements.
D.CATV/Coax Line Protection
Typical 150V/230V Arrester
Cable TV/coaxial cable protection
Arresters are particularly well suited for protecting the coaxial cables frequently laid
in CATV networks ,as they do not disturb the system even at high frequencies thanks
to their low self-capacitance of typ.0.5 to 1 pF .The arrester is contained in the
coaxial protection module where it is connected between the central conductor and
the shielding .lt is recommended to ground either the shielding or the housing of the
protection module ,depending on the application
2. Basic Circuit of application
A. 2-electrode arrester over-voltage protection circuit
B. 3-electrode arrester over-voltage protection circuit
C. Over-voltage and over-current protection circuit of
3 - electrode arrester with failsafe mechanism.
D. Over-voltage and over-current protection circuit of
2 - electrode arrester with PTC thermistor.
E. Over-voltage and over-current protection circuit of
3 - electrode arrester with PTC thermistor.
F. Over-voltage and over-current protection circuit of
3 - electrode arrester with PTC thermistor and failsafe mechanism.
2-Electrode Ceramic Surge Arrester
Electrical Characteristics
Impulse
Impulse
Impulse
AC
Spark-over
Spark-over
discharge current
discharge current
discharge current
voltage(100V/S)
voltage(1KV/us)
(10/1000us 300times)
(8/20us10times)
(50Hz 1s 5times)
V
V
A
KA
≤600
100
90±25%
≤600
150±20%
DC
type
Capacitance
Holdover
Insulation
Voltage
resistance
A
V
Ω
pF
10
10
/
≥1010
<1.5
100
10
10
/
≥1010
<1.5
≤700
100
10
10
80
≥1010
<1
230±20%
≤800
100
10
10
135
≥1010
<1
350±20%
≤800
100
10
10
135
≥1010
<1
400±20%
≤900
100
10
10
135
≥1010
<1
420±20%
≤900
100
10
10
135
≥1010
<1
470±20%
≤900
100
10
10
135
≥1010
<1
600±20%
≤1200
100
10
10
135
≥1010
<1
2R-75A5
2R-75A5L
75±25%
2R-75A6
2R-75A6L
2R-90A5
2R-90A5L
2R-90A6
2R-90A6L
2R-150A5
2R-150A5L
2R-150A6
2R-150A6L
2R-230A5
2R-230A5L
2R-230A6
2R-230A6L
2R-350A5
2R-350A5L
2R-350A6
2R-350A6L
2R-40A5
2R-40A5L
2R-40A6
2R-40A6L
2R-420A5
2R-420A5L
2R-420A6
2R-420A6L
2R-470A5
2R-470A5L
2R-470A6
2R-470A6L
2R-600A5
2R-600A5L
2R-600A6
2R-600A6L