FRVL Series

Radial Leaded PPTC
FRVL Series
RoHS Compliant &
Lead Free
Application : Line Voltage Power Supply, Transformer
and Appliances Product
Features : Solid state, Radial leaded product ideal for up
to 120VAC/VDC
Maximum Operation Current : 0.10A~3.75A
Maximum Voltage : 120VAC/DC
Maximum Interrupt Voltage : 135VAC/DC
Temperature Range : -40℃ to 85℃
Agency Recognition : UL :File No. E211981
*C-UL:File No. E211981
TÜV :File No. R50122733
Electrical Characteristics (23℃
℃)
Part
Number
Hold
Current
FRVL010-120F
FRVL017-120F
FRVL020-120F
FRVL025-120F
FRVL030-120F
FRVL040-120F
FRVL050-120F
FRVL065-120F
FRVL070-120F
FRVL075-120F
FRVL090-120F
FRVL100-120F
FRVL110-120F
FRVL125-120F
FRVL130-120F
FRVL135-120F
FRVL160-120F
FRVL185-120F
FRVL200-120F
FRVL250-120F
FRVL300-120F
FRVL375-120F
Trip
Max.Time
Max.
Current
to Trip
Current
IH, A
IT, A
at 5xIH,s
IMAX, A
0.10
0.17
0.20
0.25
0.30
0.40
0.50
0.65
0.75
0.75
0.90
1.00
1.10
1.25
1.35
1.35
1.60
1.85
2.00
2.50
3.00
3.75
0.20
0.34
0.40
0.50
0.60
0.80
1.00
1.30
1.50
1.50
1.80
2.00
2.20
2.50
2.70
2.70
3.20
3.70
4.20
5.00
6.00
7.50
10.0
10.0
9.0
7.5
8.5
6.5
6.0
5.7
6.3
15.0
7.2
15.0
8.2
20.0
9.6
20.0
11.4
12.6
36.0
15.6
19.8
24.0
2.0
2.0
2.0
3.0
3.0
3.0
3.0
5.0
5.0
7.5
5.0
10.0
8.0
12.5
10.0
13.5
12.0
12.0
20.0
15.0
17.0
20.0
Max. Oper.
Voltage
Max. Int.
Voltage
VMAX, VAC/DC VI-MAX,VAC/DC
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
Resistance
RMIN
R1MAX
Ohms
Ohms
Typ.
Power
Pd, W
0.84
0.84
1.08
1.08
1.44
1.44
1.56
1.68
1.80
2.64
1.80
2.64
2.28
2.88
2.64
3.12
3.12
3.36
4.32
4.44
4.56
4.80
135
135
135
135
135
135
135
135
135
135
135
135
135
135
135
135
135
135
135
135
135
135
3.00
2.00
1.83
1.25
0.88
0.55
0.50
0.31
0.25
0.25
0.20
0.18
0.15
0.11
0.12
0.11
0.09
0.08
0.08
0.05
0.04
0.03
7.50
7.00
4.40
3.00
2.10
1.29
1.17
0.72
0.60
0.69
0.47
0.47
0.38
0.33
0.30
0.30
0.22
0.19
0.21
0.13
0.10
0.08
Physical specifications:
Lead material: Tin plated copper, 24AWG, 22AWG, 20AWG
Soldering characteristics:MIL-STD-202, Method 208E.
Insulating coating:Flame retardant epoxy, meets UL 94 V-0 requirement.
*NOTE : C-UL is only applied for FRVL010-120F~FRVL030-120F, FRVL075-120F and FRVL135-120F~FRVL375-120F.
Thermal Derating for PPTC Device at Various Ambient Temperatures
TEMPERATURE
DERATING %
-40
-20
158%
138%
0
119%
NOTE : All Specifications subject to change without notice.
23
30
40
50
60
70
85
100%
90%
80%
70%
60%
50%
38%
32
Radial Leaded PPTC
FRVL Product Dimensions (mm)
Part
Fig
Number
Fig.1
Lead S ize :24AWG
Φ 0.51 mm Diameter
Fig.3
Lead Size :20AWG
Φ 0.81 mm Diameter
Fig.2
Lead Size :22AWG
Φ 0.65 mm Diameter
Fig.4
Lead Size : 20AWG
Φ 0.81 mm Diameter
FRVL010-120F
FRVL017-120F
FRVL020-120F
FRVL025-120F
FRVL030-120F
FRVL040-120F
FRVL050-120F
FRVL065-120F
FRVL070-120F
FRVL075-120F
FRVL090-120F
FRVL100-120F
FRVL110-120F
FRVL125-120F
FRVL130-120F
FRVL135-120F
FRVL160-120F
FRVL185-120F
FRVL200-120F
FRVL250-120F
FRVL300-120F
FRVL375-120F
1
1
2
2
2
2
2
2
2
4
2
4
3
4
3
4
3
3
4
3
3
3
A
B
C
D
E
F
Max
Max
Typ
Min
Max
Typ
7.9
7.9
7.9
7.9
7.9
8.2
9.2
9.7
10.6
10.9
11.9
11.5
13.3
14.0
15.5
16.3
17.5
19.9
23.5
22.5
25.5
29.5
13.0
13.0
13.0
13.0
13.0
14.2
14.9
14.9
15.5
17.0
15.9
20.1
18.3
21.7
20.6
21.7
22.5
24.9
27.9
27.5
30.0
34.0
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
10.2
10.2
10.2
10.2
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
4.1
3.8
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
Typical Time-To-Trip at 23℃
℃
1000
A
BCDE
FG
H I J KL MN O P Q
100
Time-to-trip (s)
A =FRVL010-120F
B =FRVL017-120F
C =FRVL020-120F
D =FRVL025-120F
E =FRVL030-120F
F =FRVL040-120F
G =FRVL050-120F
H =FRVL065-120F
I =FRVL070-120F
J =FRVL090-120F
K =FRVL110-120F
L =FRVL130-120F
M =FRVL160-120F
N =FRVL185-120F
O =FRVL250-120F
P =FRVL300-120F
Q =FRVL375-120F
10
1
0.1
0.01
0.1
1
10
Fault current (A)
100
Radial Leaded PPTC
R=FRVL075-120F
100
S=FRVL100-120F
R STU
V
T=FRVL125-120F
U=FRVL135-120F
Time-to-trip (s)
V=FRVL200-120F
10
R STU
V
1
0.1
0.01
0.1
1
10
100
Fault current (A)
Part Numbering System
Part Marking System
FRVL □ □ □ ─ □ □ □ F
RoHS Compliant / Lead Free
Voltage rating
F
RVL10F
19AJ
F
RVL
□ □ F
Current rating
□ □ □ □
Example
Standard Package
FRVL010-120F~FRVL050-120F
FRVL065-120F~FRVL075-120F
FRVL090-120F
FRVL100-120F~FRVL110-120F
FRVL125-120F~FRVL135-120F
FRVL160-120F
FRVL185-120F~FRVL375-120F
:
:
:
:
:
:
:
RoHS Compliant / Lead Free
Part Identification
Product Family
Date Code/Lot Number
500 Pcs/Bag, 2.0K Reel/Tape
300 Pcs/Bag, 1.5K Reel/Tape
300 Pcs/Bag, 2.0K Reel/Tape
300 Pcs/Bag, 1.5K Reel/Tape
200 Pcs/Bag, 1.0K Reel/Tape
200 Pcs/Bag
100 Pcs/Bag
Warning: - Each product should be carefully evaluated and tested for their suitability of application.
- Operation beyond the specified maximum ratings or improper use may result in damage and possible electrical
arcing and/or flame.
- PPTC device are intended for occasional overcurrent protection. Application for repeated overcurrent condition
and/or prolonged trip are not anticipated.
- Avoid contact of PPTC device with chemical solvent, including some inert material such as silicone based oil,
lubricant and etc. Prolonged contact will damage the device performance.
- Additional protection mechanism are strongly recommended to be used in conjunction with the PPTC device for
protection against abnormal or failure conditions.
- Avoid use of PPTC device in a constrained space such as potting material, housing and containers where have
limited space to accommodate device thermal expansion and/or contraction.