Radial Leaded PPTC FRVL Series RoHS Compliant & Lead Free Application : Line Voltage Power Supply, Transformer and Appliances Product Features : Solid state, Radial leaded product ideal for up to 120VAC/VDC Maximum Operation Current : 0.10A~3.75A Maximum Voltage : 120VAC/DC Maximum Interrupt Voltage : 135VAC/DC Temperature Range : -40℃ to 85℃ Agency Recognition : UL :File No. E211981 *C-UL:File No. E211981 TÜV :File No. R50122733 Electrical Characteristics (23℃ ℃) Part Number Hold Current FRVL010-120F FRVL017-120F FRVL020-120F FRVL025-120F FRVL030-120F FRVL040-120F FRVL050-120F FRVL065-120F FRVL070-120F FRVL075-120F FRVL090-120F FRVL100-120F FRVL110-120F FRVL125-120F FRVL130-120F FRVL135-120F FRVL160-120F FRVL185-120F FRVL200-120F FRVL250-120F FRVL300-120F FRVL375-120F Trip Max.Time Max. Current to Trip Current IH, A IT, A at 5xIH,s IMAX, A 0.10 0.17 0.20 0.25 0.30 0.40 0.50 0.65 0.75 0.75 0.90 1.00 1.10 1.25 1.35 1.35 1.60 1.85 2.00 2.50 3.00 3.75 0.20 0.34 0.40 0.50 0.60 0.80 1.00 1.30 1.50 1.50 1.80 2.00 2.20 2.50 2.70 2.70 3.20 3.70 4.20 5.00 6.00 7.50 10.0 10.0 9.0 7.5 8.5 6.5 6.0 5.7 6.3 15.0 7.2 15.0 8.2 20.0 9.6 20.0 11.4 12.6 36.0 15.6 19.8 24.0 2.0 2.0 2.0 3.0 3.0 3.0 3.0 5.0 5.0 7.5 5.0 10.0 8.0 12.5 10.0 13.5 12.0 12.0 20.0 15.0 17.0 20.0 Max. Oper. Voltage Max. Int. Voltage VMAX, VAC/DC VI-MAX,VAC/DC 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 Resistance RMIN R1MAX Ohms Ohms Typ. Power Pd, W 0.84 0.84 1.08 1.08 1.44 1.44 1.56 1.68 1.80 2.64 1.80 2.64 2.28 2.88 2.64 3.12 3.12 3.36 4.32 4.44 4.56 4.80 135 135 135 135 135 135 135 135 135 135 135 135 135 135 135 135 135 135 135 135 135 135 3.00 2.00 1.83 1.25 0.88 0.55 0.50 0.31 0.25 0.25 0.20 0.18 0.15 0.11 0.12 0.11 0.09 0.08 0.08 0.05 0.04 0.03 7.50 7.00 4.40 3.00 2.10 1.29 1.17 0.72 0.60 0.69 0.47 0.47 0.38 0.33 0.30 0.30 0.22 0.19 0.21 0.13 0.10 0.08 Physical specifications: Lead material: Tin plated copper, 24AWG, 22AWG, 20AWG Soldering characteristics:MIL-STD-202, Method 208E. Insulating coating:Flame retardant epoxy, meets UL 94 V-0 requirement. *NOTE : C-UL is only applied for FRVL010-120F~FRVL030-120F, FRVL075-120F and FRVL135-120F~FRVL375-120F. Thermal Derating for PPTC Device at Various Ambient Temperatures TEMPERATURE DERATING % -40 -20 158% 138% 0 119% NOTE : All Specifications subject to change without notice. 23 30 40 50 60 70 85 100% 90% 80% 70% 60% 50% 38% 32 Radial Leaded PPTC FRVL Product Dimensions (mm) Part Fig Number Fig.1 Lead S ize :24AWG Φ 0.51 mm Diameter Fig.3 Lead Size :20AWG Φ 0.81 mm Diameter Fig.2 Lead Size :22AWG Φ 0.65 mm Diameter Fig.4 Lead Size : 20AWG Φ 0.81 mm Diameter FRVL010-120F FRVL017-120F FRVL020-120F FRVL025-120F FRVL030-120F FRVL040-120F FRVL050-120F FRVL065-120F FRVL070-120F FRVL075-120F FRVL090-120F FRVL100-120F FRVL110-120F FRVL125-120F FRVL130-120F FRVL135-120F FRVL160-120F FRVL185-120F FRVL200-120F FRVL250-120F FRVL300-120F FRVL375-120F 1 1 2 2 2 2 2 2 2 4 2 4 3 4 3 4 3 3 4 3 3 3 A B C D E F Max Max Typ Min Max Typ 7.9 7.9 7.9 7.9 7.9 8.2 9.2 9.7 10.6 10.9 11.9 11.5 13.3 14.0 15.5 16.3 17.5 19.9 23.5 22.5 25.5 29.5 13.0 13.0 13.0 13.0 13.0 14.2 14.9 14.9 15.5 17.0 15.9 20.1 18.3 21.7 20.6 21.7 22.5 24.9 27.9 27.5 30.0 34.0 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 10.2 10.2 10.2 10.2 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 4.1 3.8 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 Typical Time-To-Trip at 23℃ ℃ 1000 A BCDE FG H I J KL MN O P Q 100 Time-to-trip (s) A =FRVL010-120F B =FRVL017-120F C =FRVL020-120F D =FRVL025-120F E =FRVL030-120F F =FRVL040-120F G =FRVL050-120F H =FRVL065-120F I =FRVL070-120F J =FRVL090-120F K =FRVL110-120F L =FRVL130-120F M =FRVL160-120F N =FRVL185-120F O =FRVL250-120F P =FRVL300-120F Q =FRVL375-120F 10 1 0.1 0.01 0.1 1 10 Fault current (A) 100 Radial Leaded PPTC R=FRVL075-120F 100 S=FRVL100-120F R STU V T=FRVL125-120F U=FRVL135-120F Time-to-trip (s) V=FRVL200-120F 10 R STU V 1 0.1 0.01 0.1 1 10 100 Fault current (A) Part Numbering System Part Marking System FRVL □ □ □ ─ □ □ □ F RoHS Compliant / Lead Free Voltage rating F RVL10F 19AJ F RVL □ □ F Current rating □ □ □ □ Example Standard Package FRVL010-120F~FRVL050-120F FRVL065-120F~FRVL075-120F FRVL090-120F FRVL100-120F~FRVL110-120F FRVL125-120F~FRVL135-120F FRVL160-120F FRVL185-120F~FRVL375-120F : : : : : : : RoHS Compliant / Lead Free Part Identification Product Family Date Code/Lot Number 500 Pcs/Bag, 2.0K Reel/Tape 300 Pcs/Bag, 1.5K Reel/Tape 300 Pcs/Bag, 2.0K Reel/Tape 300 Pcs/Bag, 1.5K Reel/Tape 200 Pcs/Bag, 1.0K Reel/Tape 200 Pcs/Bag 100 Pcs/Bag Warning: - Each product should be carefully evaluated and tested for their suitability of application. - Operation beyond the specified maximum ratings or improper use may result in damage and possible electrical arcing and/or flame. - PPTC device are intended for occasional overcurrent protection. Application for repeated overcurrent condition and/or prolonged trip are not anticipated. - Avoid contact of PPTC device with chemical solvent, including some inert material such as silicone based oil, lubricant and etc. Prolonged contact will damage the device performance. - Additional protection mechanism are strongly recommended to be used in conjunction with the PPTC device for protection against abnormal or failure conditions. - Avoid use of PPTC device in a constrained space such as potting material, housing and containers where have limited space to accommodate device thermal expansion and/or contraction.