FRVL125-120F

Radial Leaded PTC Resettable Fuse : FRVL125-120F
1. Summary
(a)
(b)
(c)
(d)
(e)
(f)
(g)
RoHS Compliant (Lead Free) product
Applications : Wide variety of electronic equipment
Product Features : Solid state, Radial leaded product ideal for up to 135VAC/DC
Operation Current : 1.25A
Maximum Operation Voltage : 120VAC/DC
Maximum Interrupt Voltage : 135VAC/DC
Temperature Range : -40℃ to 85℃
2. Agency Recognition
UL :
TÜV:
File No. E211981
File No. R50122733
3. Electrical Characteristics (23℃)
Part
Number
FRVL125-120F
Hold
Trip
Max.Time
Maximum
Rated
Max Int. Typical
Current
Current
to Trip
Current
Voltage Voltage
Power
Rmin
R1max.
IH, A
IT, A
at 5XIH, Sec
Imax, A
Vmax, V Vmax, V
Pd, W
ohms
ohms
1.25
2.50
20.00
12.5
2.88
0.11
0.33
120
135
Resistance Tolerance
IH=Hold current-maximum current at which the device will not trip at 23℃ still air.
IT=Trip current-minimum current at which the device will always trip at 23℃ still air.
V MAX=Maximum voltage device can withstand without damage at its rated current.
I MAX= Maximum fault current device can withstand without damage at rated voltage (V MAX).
Pd=Typical power dissipated from device when in tripped state in 23℃ still air environment.
RMIN=Minimum device resistance at 23℃.
R1MAX=Maximum device resistance at 23℃, 1 hour after tripping .
Physical specifications:
Lead material: Tin plated copper,20AWG.
Soldering characteristics:MIL-STD-202, Method 208E.
Insulating coating:Flame retardant epoxy, meets UL-94V-0 requirement.
4. Production Dimensions (millimeter)
FRVL125-120F
Lead Size : 20AWG
Φ 0.81 mm Diameter
Part
Number
FRVL125-120F
A
B
C
D
E
F
Maximum
14.0
Maximum
21.7
Typical
5.1
Minimum
7.6
Maximum
4.1
Typical
2.2
NOTE : Specification subject to change without notice.
5. Thermal Derating Curve
FRVL125-120F
Percent of Rated Hold and Trip Current
200%
150%
100%
50%
0%
-20
0
20
40
60
80
Ambient Temperature,℃
6. Typical Time-To-Trip at 23℃
刪除:
FRVL125-120F
Time-to-trip (S)
100
10
1
0.1
1
10
Fault current (A)
NOTE : Specification subject to change without notice.
100
7. Material Specification
Lead material:Tin plated copper, 20 AWG.
Soldering characteristics:MIL-STD-202, Method 208E.
Insulating coating:Flame retardant epoxy, meets UL-94V-0 requirement
8. Part Numbering and Marking System
Part Numbering System
FRVL □ □ □ ─ □ □ □
F
RoHS Compliant / Lead Free
Voltage rating
Part Marking System
F
RVL125F
61BD
F
RVL □ □ □ F
Current rating
□
□ □ □
RoHS Compliant / Lead Free
Part Identification
Product Family
Example
Date Code/Lot Number
Warning: - Each product should be carefully evaluated and tested for their suitability of application.
- Operation beyond the s pecified maximu m rating or i mproper use may result i n d amage and pos sible
electrical arcing and/or flame.
- PP TC dev ice are i ntended for occ asional o vercurrent protecti on. Ap plication for rep eated o vercurrent
condition and/or prolonged trip are not anticipated.
- Avoid contact of PPTC device with chemical solvent, including some inert material such as silicone based
oil, lubricant and etc. Prolonged contact will damage the device performance.
- Ad ditional prote ction mechanism are strongly rec ommended to be used in c onjunction with the PPT C
device for protection against abnormal or failure conditions.
- Avoid use of PPTC device in a constrained space such as potting material, housing and containers where
have limited space to accommodate device thermal expansion and/or contraction.
NOTE : Specification subject to change without notice.