W9412G6JB 2M 4 BANKS 16 BITS DDR SDRAM Table of Contents1. GENERAL DESCRIPTION ......................................................................................................... 4 2. FEATURES ................................................................................................................................. 4 3. ORDER INFORMATION ............................................................................................................. 4 4. KEY PARAMETERS ................................................................................................................... 5 5. BALL CONFIGURATION ............................................................................................................ 6 6. BALL DESCRIPTION .................................................................................................................. 7 7. BLOCK DIAGRAM ...................................................................................................................... 8 8. FUNCTIONAL DESCRIPTION.................................................................................................... 9 8.1 Power Up Sequence ....................................................................................................... 9 8.2 Command Function ...................................................................................................... 10 8.2.1 Bank Activate Command ........................................................................... 10 8.2.2 Bank Precharge Command........................................................................ 10 8.2.3 Precharge All Command ............................................................................ 10 8.2.4 Write Command ......................................................................................... 10 8.2.5 Write with Auto-precharge Command ........................................................ 10 8.2.6 Read Command ......................................................................................... 10 8.2.7 Read with Auto-precharge Command ....................................................... 10 8.2.8 Mode Register Set Command.................................................................... 11 8.2.9 Extended Mode Register Set Command ................................................... 11 8.2.10 No-Operation Command ............................................................................ 11 8.2.11 Burst Read Stop Command ....................................................................... 11 8.2.12 Device Deselect Command ....................................................................... 11 8.2.13 Auto Refresh Command ............................................................................ 11 8.2.14 Self Refresh Entry Command .................................................................... 12 8.2.15 Self Refresh Exit Command....................................................................... 12 8.2.16 Data Write Enable /Disable Command ...................................................... 12 8.3 Read Operation............................................................................................................. 12 8.4 Write Operation ............................................................................................................. 13 8.5 Precharge ..................................................................................................................... 13 8.6 Burst Termination.......................................................................................................... 13 8.7 Refresh Operation......................................................................................................... 13 8.8 Power Down Mode ....................................................................................................... 14 8.9 Input Clock Frequency Change during Precharge Power Down Mode ........................ 14 -1- Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB 8.10 9. 10. 11. 12. Mode Register Operation .............................................................................................. 14 8.10.1 Burst Length field (A2 to A0) ...................................................................... 14 8.10.2 Addressing Mode Select (A3) .................................................................... 15 8.10.3 CAS Latency field (A6 to A4) ..................................................................... 16 8.10.4 DLL Reset bit (A8) ..................................................................................... 16 8.10.5 Mode Register/Extended Mode register change bits (BA0, BA1) .............. 16 8.10.6 Extended Mode Register field .................................................................... 16 8.10.7 Reserved field ............................................................................................ 16 OPERATION MODE ................................................................................................................. 17 9.1 Simplified Truth Table ................................................................................................... 17 9.2 Function Truth Table ..................................................................................................... 18 9.3 Function Truth Table for CKE ....................................................................................... 21 9.4 Simplified Stated Diagram ............................................................................................ 22 ELECTRICAL CHARACTERISTICS ......................................................................................... 23 10.1 Absolute Maximum Ratings .......................................................................................... 23 10.2 Recommended DC Operating Conditions .................................................................... 23 10.3 Capacitance .................................................................................................................. 24 10.4 Leakage and Output Buffer Characteristics .................................................................. 24 10.5 DC Characteristics ........................................................................................................ 25 10.6 AC Characteristics and Operating Condition ................................................................ 26 10.7 AC Test Conditions ....................................................................................................... 27 SYSTEM CHARACTERISTICS FOR DDR SDRAM ................................................................. 29 11.1 Table 1: Input Slew Rate for DQ, DQS, and DM .......................................................... 29 11.2 Table 2: Input Setup & Hold Time Derating for Slew Rate ........................................... 29 11.3 Table 3: Input/Output Setup & Hold Time Derating for Slew Rate ............................... 29 11.4 Table 4: Input/Output Setup & Hold Derating for Rise/Fall Delta Slew Rate ................ 29 11.5 Table 5: Output Slew Rate Characteristics (X16 Devices only) ................................... 29 11.6 Table 6: Output Slew Rate Matching Ratio Characteristics ......................................... 30 11.7 Table 7: AC Overshoot/Undershoot Specification for Address and Control Pins ......... 30 11.8 Table 8: Overshoot/Undershoot Specification for Data, Strobe, and Mask Pins .......... 31 11.9 System Notes:............................................................................................................... 32 TIMING WAVEFORMS ............................................................................................................. 34 12.1 Command Input Timing ................................................................................................ 34 12.2 Timing of the CLK Signals ............................................................................................ 34 12.3 Read Timing (Burst Length = 4) ................................................................................... 35 12.4 Write Timing (Burst Length = 4) .................................................................................... 36 12.5 DM, DATA MASK (W9412G6JB).................................................................................. 37 -2- Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB 12.6 Mode Register Set (MRS) Timing ................................................................................. 38 12.7 Extend Mode Register Set (EMRS) Timing .................................................................. 39 12.8 Auto-precharge Timing (Read Cycle, CL = 2) .............................................................. 40 12.9 Auto-precharge Timing (Read cycle, CL = 2), continued ............................................. 41 12.10 Auto-precharge Timing (Write Cycle) .......................................................................... 42 12.11 Read Interrupted by Read (CL = 2, BL = 2, 4, 8) ........................................................ 43 12.12 Burst Read Stop (BL = 8) ............................................................................................ 43 12.13 Read Interrupted by Write & BST (BL = 8) .................................................................. 44 12.14 Read Interrupted by Precharge (BL = 8) ..................................................................... 44 12.15 Write Interrupted by Write (BL = 2, 4, 8) ..................................................................... 45 12.16 Write Interrupted by Read (CL = 2, BL = 8) ................................................................ 45 12.17 Write Interrupted by Read (CL = 3, BL = 4) ................................................................ 46 12.18 Write Interrupted by Precharge (BL = 8) ..................................................................... 46 12.19 2 Bank Interleave Read Operation (CL = 2, BL = 2) ................................................... 47 12.20 2 Bank Interleave Read Operation (CL = 2, BL = 4) ................................................... 47 12.21 4 Bank Interleave Read Operation (CL = 2, BL = 2) ................................................... 48 12.22 4 Bank Interleave Read Operation (CL = 2, BL = 4) ................................................... 48 12.23 Auto Refresh Cycle ..................................................................................................... 49 12.24 Precharged/Active Power Down Mode Entry and Exit Timing .................................... 49 12.25 Input Clock Frequency Change during Precharge Power Down Mode Timing .......... 49 12.26 Self Refresh Entry and Exit Timing ............................................................................. 50 13. Package Specification ............................................................................................................... 51 14. REVISION HISTORY ................................................................................................................ 52 -3- Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB 1. GENERAL DESCRIPTION W9412G6JB is a CMOS Double Data Rate synchronous dynamic random access memory (DDR SDRAM); organized as 2M words 4 banks 16 bits. W9412G6JB delivers a data bandwidth of up to 500M words per second (-4). To fully comply with the personal computer industrial standard, W9412G6JB is sorted into the following speed grades: -4, -5 and -5I. The -4 is compliant to the DDR500/CL3 and CL4 specification. The -5/-5I is compliant to the DDR400/CL3 specification (the -5I grade which is guaranteed to support -40°C ~ 85°C). All Input reference to the positive edge of CLK (except for DQ, DM and CKE). The timing reference point for the differential clock is when the CLK and CLK signals cross during a transition. Write and Read data are synchronized with the both edges of DQS (Data Strobe). By having a programmable Mode Register, the system can change burst length, latency cycle, interleave or sequential burst to maximize its performance. W9412G6JB is ideal for main memory in high performance applications. 2. FEATURES 2.5V 0.2V Power Supply for DDR400 2.4V~2.7V Power Supply for DDR500 Up to 250 MHz Clock Frequency Double Data Rate architecture; two data transfers per clock cycle Differential clock inputs (CLK and CLK ) DQS is edge-aligned with data for Read; center-aligned with data for Write CAS Latency: 2, 2.5, 3 and 4 Burst Length: 2, 4 and 8 Auto Refresh and Self Refresh Precharged Power Down and Active Power Down Write Data Mask Write Latency = 1 15.6µS Refresh interval (4K/64 mS Refresh) Maximum burst refresh cycle: 8 Interface: SSTL_2 Packaged in 60 Ball TFBGA (8X13 mm2), using Lead free materials with RoHS compliant 3. ORDER INFORMATION PART NUMBER W9412G6JB-4 W9412G6JB-5 W9412G6JB-5I SPEED DDR500/CL3 and CL4 DDR400/CL3 DDR400/CL3 -4- SELF REFRESH CURRENT (MAX.) OPERATING TEMPERATURE 2 mA 2 mA 2 mA 0°C ~ 70°C 0°C ~ 70°C -40°C ~ 85°C Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB 4. KEY PARAMETERS SYMBOL DESCRIPTION CL = 2 CL = 2.5 tCK Clock Cycle Time CL = 3 CL = 4 MIN/MAX. -4 -5/-5I Min. - 7.5 nS Max. - 12 nS Min. - 6 nS Max. - 12 nS Min. 4 nS 5 nS Max. 12 nS 12 nS Min. 4 nS - Max. 12 nS - tRAS Active to Precharge Command Period Min. 40 nS 40 nS tRC Active to Ref/Active Command Period Min. 48 nS 50 nS IDD0 Operating Current: One Bank Active-Precharge Max. 60 mA 55 mA IDD1 Operating Current: One Bank Active-Read-Precharge Max. 75 mA 65 mA IDD4R Burst Operation Current Max. 140 mA 120 mA IDD4W Burst Operation Current Max. 135 mA 115 mA IDD5 Auto Refresh Burst current Max. 75 mA 70 mA IDD6 Self-Refresh Current Max. 2 mA 2 mA -5- Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB 5. BALL CONFIGURATION 1 2 3 VSSQ DQ15 VSS DQ14 VDDQ DQ12 DQ10 DQ8 VREF VSSQ VDDQ VSSQ 7 8 9 A VDD DQ0 VDDQ DQ13 B DQ2 VSSQ DQ1 DQ11 C DQ4 D DQ6 E LDQS DQ9 UDQS : Ball Existing : Depopulated Ball Top View (See the balls through the Package) VDDQ DQ3 1 2 3 4 5 6 7 8 9 A 1.0 mm B VSSQ DQ5 C D VDDQ DQ7 E 13.0 mm F VSS UDM F LDM VDD CLK CLK G WE CAS NC CKE H RAS CS A11 A9 J BA1 BA0 A8 A7 K A0 A10/AP A6 A5 L A2 A1 A4 VSS M VDD A3 NC G H J K L M 0.8 mm 8.0 mm BGA Package Ball Pattern Top View Device Ball Pattern -6- Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB 6. BALL DESCRIPTION BALL NUMBER SYMBOL FUNCTION DESCRIPTION Multiplexed pins for row and column address. Row address: A0A11. Column address: A0A8. Provide the row address for Bank Activate commands, and the column address and Auto-precharge bit (A10) for Read/Write commands, to select one location out of the memory array in the respective bank. A10 is sampled during a precharge command to determine whether the precharge applies to one bank (A10 Low) or all banks (A10 High). If only one bank is to be precharged, the bank is selected by BA0, BA1. The address inputs also provide the op-code during a Mode Register Set command. BA0 and BA1 define which mode register is loaded during the Mode Register Set command (MRS or EMRS). K7, L8, L7, M8, M2, L3, L2, K3, K2, J3, K8, J2 A0 A11 Address J8, J7 BA0, BA1 Bank Select Select bank to activate during row address latch time, or bank to read/write during column address latch time. A8, B9, B7, C9, C7, D9, D7, E9, E1, D3, D1, C3, C1, B3, B1, A2 DQ0 DQ15 Data Input/ Output The DQ0 – DQ15 input and output data are synchronized with both edges of DQS. E7, E3 LDQS, UDQS Data Strobe DQS is Bi-directional signal. DQS is input signal during write operation and output signal during read operation. It is Edgealigned with read data, Center-aligned with write data. H8 CS Chip Select Disable or enable the command decoder. When command decoder is disabled, new command is ignored and previous operation continues. H7, G8, G7 RAS , Command Inputs CAS , WE Command inputs (along with CS ) define the command being entered. LDM, UDM Write Mask When DM is asserted “high” in burst write, the input data is masked. DM is synchronized with both edges of DQS. CLK, CLK Differential Clock Inputs All address and control input signals are sampled on the crossing of the positive edge of CLK and negative edge of CLK . H3 CKE Clock Enable CKE controls the clock activation and deactivation. When CKE is low, Power Down mode, Suspend mode, or Self Refresh mode is entered. F1 VREF F8, M7, A7 VDD Power Power for logic circuit inside DDR SDRAM. A3, F2, M3 VSS Ground Ground for logic circuit inside DDR SDRAM. B2, D2, C8, E8, A9 VDDQ Power for I/O Buffer Separated power from VDD, used for output buffer, to improve noise. A1, C2, E2, B8, D8 VSSQ Ground for I/O Buffer Separated ground from VSS, used for output buffer, to improve noise. H2, F9 NC No Connection No connection F7, F3 G2, G3 Reference Voltage VREF is reference voltage for inputs. -7- Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB 7. BLOCK DIAGRAM CLK CLK DLL CLOCK BUFFER CKE CONTROL CS RAS SIGNAL GENERATOR COMMAND CAS DECODER COLUMN DECODER A10 CELL ARRAY BANK #0 COLUMN DECODER ROW DECODER ROW DECODER WE MODE REGISTER A0 CELL ARRAY BANK #1 SENSE AMPLIFIER SENSE AMPLIFIER ADDRESS BUFFER PREFETCH REGISTER DQ DATA CONTROL BUFFER DQ0 DQ15 CIRCUIT COLUMN COUNTER COUNTER LDQS UDQS LDM UDM COLUMN DECODER CELL ARRAY BANK #2 COLUMN DECODER ROW DECODER REFRESH ROW DECODER A9 A11 BA0 BA1 SENSE AMPLIFIER CELL ARRAY BANK #3 SENSE AMPLIFIER NOTE: The cell array configuration is 4096 * 512 * 16 -8- Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB 8. FUNCTIONAL DESCRIPTION 8.1 Power Up Sequence (1) (2) (3) (4) (5) (6) (7) (8) (9) Apply power and attempt to CKE at a low state ( 0.2V), all other inputs may be undefined 1) Apply VDD before or at the same time as VDDQ. 2) Apply VDDQ before or at the same time as VTT and VREF. Start Clock and maintain stable condition for 200 µS (min.). After stable power and clock, apply NOP and take CKE high. Issue precharge command for all banks of the device. Issue EMRS (Extended Mode Register Set) to enable DLL and establish Output Driver Type. Issue MRS (Mode Register Set) to reset DLL and set device to idle with bit A8. (An additional 200 cycles(min) of clock are required for DLL Lock before any executable command applied.) Issue precharge command for all banks of the device. Issue two or more Auto Refresh commands. Issue MRS-Initialize device operation with the reset DLL bit deactivated A8 to low. CLK CLK Command PREA EMRS tRP MRS 2 Clock min. PREA 2 Clock min. AREF tRP AREF tRFC ANY CMD MRS tRFC 2 Clock min. 200 Clock min. Inputs maintain stable for 200 µS min. Enable DLL Disable DLL reset with A8 = Low DLL reset with A8 = High Initialization sequence after power-up -9- Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB 8.2 Command Function 8.2.1 Bank Activate Command ( RAS = “L”, CAS = “H”, WE = “H”, BA0, BA1 = Bank, A0 to A11 = Row Address) The Bank Activate command activates the bank designated by the BA (Bank address) signal. Row addresses are latched on A0 to A11 when this command is issued and the cell data is read out of the sense amplifiers. The maximum time that each bank can be held in the active state is specified as tRAS (max). After this command is issued, Read or Write operation can be executed. 8.2.2 Bank Precharge Command ( RAS = “L”, CAS = “H”, WE = “L”, BA0, BA1 = Bank, A10 = “L”, A0 to A9, A11 = Don’t Care) The Bank Precharge command percharges the bank designated by BA. The precharged bank is switched from the active state to the idle state. 8.2.3 Precharge All Command ( RAS = “L”, CAS = “H”, WE = “L”, BA0, BA1 = Don’t Care, A10 = “H”, A0 to A9, A11 = Don’t Care) The Precharge All command precharges all banks simultaneously. Then all banks are switched to the idle state. 8.2.4 Write Command ( RAS = “H”, CAS = “L”, WE = “L”, BA0, BA1 = Bank, A10 = “L”, A0 to A8 = Column Address) The write command performs a Write operation to the bank designated by BA. The write data are latched at both edges of DQS. The length of the write data (Burst Length) and column access sequence (Addressing Mode) must be in the Mode Register at power-up prior to the Write operation. 8.2.5 Write with Auto-precharge Command ( RAS = “H”, CAS = “L”, WE = “L”, BA0, BA1 = Bank, A10 = “H”, A0 to A8 = Column Address) The Write with Auto-precharge command performs the Precharge operation automatically after the Write operation. This command must not be interrupted by any other commands. 8.2.6 Read Command ( RAS = “H”, CAS = “L”, WE = “H”, BA0, BA1 = Bank, A10 = “L”, A0 to A8 = Column Address) The Read command performs a Read operation to the bank designated by BA. The read data are synchronized with both edges of DQS. The length of read data (Burst Length), Addressing Mode and CAS Latency (access time from CAS command in a clock cycle) must be programmed in the Mode Register at power-up prior to the Read operation. 8.2.7 Read with Auto-precharge Command ( RAS = “H”, CAS = “L”, WE = “H”, BA0, BA1 = Bank, A10 = “H”, A0 to A8 = Column Address) The Read with Auto-precharge command automatically performs the Precharge operation after the Read operation. - 10 - Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB 1) READA tRAS (min) - (BL/2) x tCK Internal precharge operation begins after BL/2 cycle from Read with Auto-precharge command. 2) tRCD(min) READA < tRAS(min) - (BL/2) x tCK Data can be read with shortest latency, but the internal Precharge operation does not begin until after tRAS (min) has completed. This command must not be interrupted by any other command. 8.2.8 Mode Register Set Command ( RAS = “L”, CAS = “L”, WE = “L”, BA0 = “L”, BA1 = “L”, A0 to A11 = Register Data) The Mode Register Set command programs the values of CAS Latency, Addressing Mode, Burst Length and DLL reset in the Mode Register. The default values in the Mode Register after powerup are undefined, therefore this command must be issued during the power-up sequence. Also, this command can be issued while all banks are in the idle state. Refer to the table for specific codes. 8.2.9 Extended Mode Register Set Command ( RAS = “L”, CAS = “L”, WE = “L”, BA0 = “H”, BA1 = “L”, A0 to A11 = Register data) The Extended Mode Register Set command can be implemented as needed for function extensions to the standard (SDR-SDRAM). Currently the only available mode in EMRS is DLL enable/disable, decoded by A0. The default value of the extended mode register is not defined; therefore this command must be issued during the power-up sequence for enabling DLL. Refer to the table for specific codes. 8.2.10 No-Operation Command ( RAS = “H”, CAS = “H”, WE = “H”) The No-Operation command simply performs no operation (same command as Device Deselect). 8.2.11 Burst Read Stop Command ( RAS = “H”, CAS = “H”, WE = “L”) The Burst stop command is used to stop the burst operation. This command is only valid during a Burst Read operation. 8.2.12 Device Deselect Command ( CS = “H”) The Device Deselect command disables the command decoder so that the RAS , CAS , WE and Address inputs are ignored. This command is similar to the No-Operation command. 8.2.13 Auto Refresh Command ( RAS = “L”, CAS = “L”, WE = “H”, CKE = “H”, BA0, BA1, A0 to A11 = Don’t Care) AUTO REFRESH is used during normal operation of the DDR SDRAM and is analogous to CAS– BEFORE–RAS (CBR) refresh in previous DRAM types. This command is non persistent, so it must be issued each time a refresh is required. The refresh addressing is generated by the internal refresh controller. This makes the address bits “Don’t Care” during an AUTO REFRESH command. The DDR SDRAM requires AUTO - 11 - Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB REFRESH cycles at an average periodic interval of tREFI (maximum). To allow for improved efficiency in scheduling and switching between tasks, some flexibility in the absolute refresh interval is provided. A maximum of eight AUTO REFRESH commands can be posted to any given DDR SDRAM, and the maximum absolute interval between any AUTO REFRESH command and the next AUTO REFRESH command is 8 * tREFI. 8.2.14 Self Refresh Entry Command ( RAS = “L”, CAS = “L”, WE = “H”, CKE = “L”, BA0, BA1, A0 to A11 = Don’t Care) The SELF REFRESH command can be used to retain data in the DDR SDRAM, even if the rest of the system is powered down. When in the self refresh mode, the DDR SDRAM retains data without external clocking. The SELF REFRESH command is initiated like an AUTO REFRESH command except CKE is disabled (LOW). The DLL is automatically disabled upon entering SELF REFRESH, and is automatically enabled upon exiting SELF REFRESH. Any time the DLL is enabled a DLL Reset must follow and 200 clock cycles should occur before a READ command can be issued. Input signals except CKE are “Don’t Care” during SELF REFRESH. Since CKE is a SSTL_2 input, VREF must be maintained during SELF REFRESH. 8.2.15 Self Refresh Exit Command (CKE = “H”, CS = “H” or CKE = “H”, RAS = “H”, CAS = “H”) The procedure for exiting self refresh requires a sequence of commands. First, CLK must be stable prior to CKE going back HIGH. Once CKE is HIGH, the DDR SDRAM must have NOP commands issued for tXSNR because time is required for the completion of any internal refresh in progress. A simple algorithm for meeting both refresh and DLL requirements is to apply NOPs for 200 clock cycles before applying any other command. The use of SELF REFREH mode introduces the possibility that an internally timed event can be missed when CKE is raised for exit from self refresh mode. Upon exit from SELF REFRESH an extra auto refresh command is recommended. 8.2.16 Data Write Enable /Disable Command (DM = “L/H” or LDM, UDM = “L/H”) During a Write cycle, the DM or LDM, UDM signal functions as Data Mask and can control every word of the input data. The LDM signal controls DQ0 to DQ7 and UDM signal controls DQ8 to DQ15. 8.3 Read Operation Issuing the Bank Activate command to the idle bank puts it into the active state. When the Read command is issued after tRCD from the Bank Activate command, the data is read out sequentially, synchronized with both edges of DQS (Burst Read operation). The initial read data becomes available after CAS Latency from the issuing of the Read command. The CAS Latency must be set in the Mode Register at power-up. When the Precharge Operation is performed on a bank during a Burst Read and operation, the Burst operation is terminated. When the Read with Auto-precharge command is issued, the Precharge operation is performed automatically after the Read cycle then the bank is switched to the idle state. This command cannot be interrupted by any other commands. Refer to the diagrams for Read operation. - 12 - Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB 8.4 Write Operation Issuing the Write command after tRCD from the bank activate command. The input data is latched sequentially, synchronizing with both edges(rising & falling) of DQS after the Write command (Burst write operation). The burst length of the Write data (Burst Length) and Addressing Mode must be set in the Mode Register at power-up. When the Precharge operation is performed in a bank during a Burst Write operation, the Burst operation is terminated. When the Write with Auto-precharge command is issued, the Precharge operation is performed automatically after the Write cycle, then the bank is switched to the idle state, The Write with Autoprecharge command cannot be interrupted by any other command for the entire burst data duration. Refer to the diagrams for Write operation. 8.5 Precharge There are two Commands, which perform the precharge operation (Bank Precharge and Precharge All). When the Bank Precharge command is issued to the active bank, the bank is precharged and then switched to the idle state. The Bank Precharge command can precharge one bank independently of the other bank and hold the unprecharged bank in the active state. The maximum time each bank can be held in the active state is specified as tRAS (max). Therefore, each bank must be precharged within tRAS(max) from the bank activate command. The Precharge All command can be used to precharge all banks simultaneously. Even if banks are not in the active state, the Precharge All command can still be issued. In this case, the Precharge operation is performed only for the active bank and the precharge bank is then switched to the idle state. 8.6 Burst Termination When the Precharge command is used for a bank in a Burst cycle, the Burst operation is terminated. When Burst Read cycle is interrupted by the Precharge command, read operation is disabled after clock cycle of (CAS Latency) from the Precharge command. When the Burst Write cycle is interrupted by the Precharge command, the input circuit is reset at the same clock cycle at which the precharge command is issued. In this case, the DM signal must be asserted “high” during tWR to prevent writing the invalided data to the cell array. When the Burst Read Stop command is issued for the bank in a Burst Read cycle, the Burst Read operation is terminated. The Burst read Stop command is not supported during a write burst operation. Refer to the diagrams for Burst termination. 8.7 Refresh Operation Two types of Refresh operation can be performed on the device: Auto Refresh and Self Refresh. By repeating the Auto Refresh cycle, each bank in turn refreshed automatically. The Refresh operation must be performed 4096 times (rows) within 64mS. The period between the Auto Refresh command and the next command is specified by tRFC. Self Refresh mode enters issuing the Self Refresh command (CKE asserted “low”) while all banks are in the idle state. The device is in Self Refresh mode for as long as CKE held “low”. In the case of distributed Auto Refresh commands, distributed auto refresh commands must be issued every 15.6 µS and the last distributed Auto Refresh commands must be performed within 15.6 µS before entering the self refresh mode. After exiting from the Self Refresh mode, the refresh operation must be performed within 15.6 µS. In Self Refresh mode, all input/output buffers are disabled, - 13 - Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB resulting in lower power dissipation (except CKE buffer). Refer to the diagrams for Refresh operation. 8.8 Power Down Mode Two types of Power Down Mode can be performed on the device: Active Standby Power Down Mode and Precharge Standby Power Down Mode. When the device enters the Power Down Mode, all input/output buffers are disabled resulting in low power dissipation (except CKE buffer). Power Down Mode enter asserting CKE “low” while the device is not running a burst cycle. Taking CKE “high” can exit this mode. When CKE goes high, a No operation command must be input at next CLK rising edge. Refer to the diagrams for Power Down Mode. 8.9 Input Clock Frequency Change during Precharge Power Down Mode DDR SDRAM input clock frequency can be changed under following condition: DDR SDRAM must be in precharged power down mode with CKE at logic LOW level. After a minimum of 2 clocks after CKE goes LOW, the clock frequency may change to any frequency between minimum and maximum operating frequency specified for the particular speed grade. During an input clock frequency change, CKE must be held LOW. Once the input clock frequency is changed, a stable clock must be provided to DRAM before precharge power down mode may be exited. The DLL must be RESET via EMRS after precharge power down exit. An additional MRS command may need to be issued to appropriately set CL etc. After the DLL relock time, the DRAM is ready to operate with new clock frequency. 8.10 Mode Register Operation The mode register is programmed by the Mode Register Set command (MRS/EMRS) when all banks are in the idle state. The data to be set in the Mode Register is transferred using the A0 to A11 and BA0, BA1 address inputs. The Mode Register designates the operation mode for the read or write cycle. The register is divided into five filed: (1) Burst Length field to set the length of burst data (2) Addressing Mode selected bit to designate the column access sequence in a Burst cycle (3) CAS Latency field to set the assess time in clock cycle (4) DLL reset field to reset the DLL (5) Regular/Extended Mode Register filed to select a type of MRS (Regular/Extended MRS). EMRS cycle can be implemented the extended function (DLL enable/Disable mode). The initial value of the Mode Register (including EMRS) after power up is undefined; therefore the Mode Register Set command must be issued before power operation. 8.10.1 Burst Length field (A2 to A0) This field specifies the data length for column access using the A2 to A0 pins and sets the Burst Length to be 2, 4 and 8 words. A2 A1 A0 BURST LENGTH 0 0 0 Reserved 0 0 1 2 words 0 1 0 4 words 0 1 1 8 words 1 x x Reserved - 14 - Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB 8.10.2 Addressing Mode Select (A3) The Addressing Mode can be one of two modes; Interleave mode or Sequential Mode, When the A3 bit is “0”, Sequential mode is selected. When the A3 bit is “1”, Interleave mode is selected. Both addressing Mode support burst length 2, 4 and 8 words. A3 ADDRESSING MODE 0 Sequential 1 Interleave 8.10.2.1. Addressing Sequence of Sequential Mode A column access is performed by incrementing the column address input to the device. The address is varied by the Burst Length as the following. Addressing Sequence of Sequential Mode DATA ACCESS ADDRESS BURST LENGTH Data 0 n 2 words (address bits is A0) Data 1 n+1 not carried from A0 to A1 Data 2 n+2 4 words (address bit A0, A1) Data 3 n+3 Not carried from A1 to A2 Data 4 n+4 Data 5 n+5 8 words (address bits A2, A1 and A0) Data 6 n+6 Not carried from A2 to A3 Data 7 n+7 8.10.2.2. Addressing Sequence for Interleave Mode A Column access is started from the inputted column address and is performed by interleaving the address bits in the sequence shown as the following. Addressing Sequence of Interleave Mode DATA ACCESS ADDRESS Data 0 A8 A7 A6 A5 A4 A3 A2 A1 A0 Data 1 A8 A7 A6 A5 A4 A3 A2 A1 A0 Data 2 A8 A7 A6 A5 A4 A3 A2 A1 A0 Data 3 A8 A7 A6 A5 A4 A3 A2 A1 A0 Data 4 A8 A7 A6 A5 A4 A3 A2 A1 A0 Data 5 A8 A7 A6 A5 A4 A3 A2 A1 A0 Data 6 A8 A7 A6 A5 A4 A3 A2 A1 A0 Data 7 A8 A7 A6 A5 A4 A3 A2 A1 A0 - 15 - BURST LENGTH 2 words 4 words 8 words Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB 8.10.3 CAS Latency field (A6 to A4) This field specifies the number of clock cycles from the assertion of the Read command to the first data read. The minimum values of CAS Latency depend on the frequency of CLK. A6 A5 A4 CAS LATENCY 0 0 0 0 1 1 1 1 0 0 1 1 0 0 1 1 0 1 0 1 0 1 0 1 Reserved Reserved 2 3 4 Reserved 2.5 Reserved 8.10.4 DLL Reset bit (A8) This bit is used to reset DLL. When the A8 bit is “1”, DLL is reset. 8.10.5 Mode Register/Extended Mode register change bits (BA0, BA1) These bits are used to select MRS/EMRS. BA1 BA0 A11-A0 0 0 1 0 1 x Regular MRS Cycle Extended MRS Cycle Reserved 8.10.6 Extended Mode Register field 1) DLL Switch field (A0) This bit is used to select DLL enable or disable A0 DLL 0 1 Enable Disable 2) Output Driver Strength Control field (A6, A1) The 100%, 60% and 30% or matched impedance driver strength are required Extended Mode Register Set (EMRS) as the following: A6 A1 BUFFER STRENGTH 0 0 1 1 0 1 0 1 100% Strength 60% Strength Reserved 30% Strength 8.10.7 Reserved field Test mode entry bit (A7) This bit is used to enter Test mode and must be set to “0” for normal operation. Reserved bits (A9, A10, A11) These bits are reserved for future operations. They must be set to “0” for normal operation. - 16 - Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB 9. OPERATION MODE The following table shows the operation commands. 9.1 Simplified Truth Table SYM. ACT PRE COMMAND Bank Active Bank Precharge DEVICE STATE Idle CKEn-1 CKEn DM (4) BA0, BA1 A10 A0-A9 ,A11 CS RAS CAS WE (3) H X X V V V L L H H (3) H X X V L X L L H L Any PREA Precharge All H X X X H X L L H L WRIT Write Active Any (3) H X X V L V L H L L WRITA Write with Autoprecharge Active (3) H X X V H V L H L L READ Read Active (3) H X X V L V L H L H READA Read with Autoprecharge Active (3) H X X V H V L H L H MRS Mode Register Set H X X L, L L L L L L L L L L H H H Idle Op-Code (6) Extended Mode Register Set Idle H X X H, L NOP No Operation Any H X X X X X BST Burst Read Stop Active H X X X X X L H H L DSL Device Deselect Any H X X X X X H X X X AREF Auto Refresh Idle H H X X X X L L L H SELF Self Refresh Entry Idle H L X X X X L L L H Idle (Self Refresh) L H X X X X H X X X L H H X EMRS SELEX Self Refresh Exit PD Power Down Mode Entry Idle/ (5) Active H L X X X X PDEX Power Down Mode Exit Any (Power Down) L H X X X X H X X X L H H X H X X X L H H X WDE Data Write Enable Active H X L X X X X X X X WDD Data Write Disable Active H X H X X X X X X X Notes 1. V = Valid X = Don’t Care L = Low level H = High level. 2. CKEn signal is input level when commands are issued CKEn-1 signal is input level one clock cycle before the commands are issued 3. These are state designated by the BA0, BA1 signals. 4. LDM, UDM (W9412G6JB) 5. Power Down Mode can not entry in the burst cycle. 6. BA0, BA1 select either the Base or the Extended Mode Register (BA0 = 0, BA1 = 0 selects Mode Register; BA0 = 1, BA1 = 0 selects Extended Mode Register; other combinations of BA0, BA1 are reserved; A0~A11 provide the op-code to be written to the selected Mode Register (MRS or EMRS). - 17 - Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB 9.2 Function Truth Table (Note 1) CURRENT STATE Idle Row Active Read Write CS RAS CAS WE ADDRESS COMMAND ACTION NOTES H X X X X DSL NOP L H H X X NOP/BST NOP L H L H BA, CA, A10 READ/READA ILLEGAL 3 L H L L BA, CA, A10 WRIT/WRITA ILLEGAL 3 L L H H BA, RA ACT Row activating L L H L BA, A10 PRE/PREA NOP L L L H X AREF/SELF Refresh or Self refresh 2 L L L L Op-Code MRS/EMRS Mode register accessing 2 H X X X X DSL NOP L H H X X NOP/BST NOP L H L H BA, CA, A10 READ/READA Begin read: Determine AP 4 L H L L BA, CA, A10 WRIT/WRITA Begin write: Determine AP 4 L L H H BA, RA ACT ILLEGAL 3 L L H L BA, A10 PRE/PREA Precharge 5 L L L H X AREF/SELF ILLEGAL L L L L Op-Code MRS/EMRS ILLEGAL H X X X X DSL Continue burst to end L H H H X NOP Continue burst to end L H H L X BST Burst stop L H L H BA, CA, A10 READ/READA Term burst, new read: Determine AP L H L L BA, CA, A10 WRIT/WRITA ILLEGAL L L H H BA, RA ACT ILLEGAL L L H L BA, A10 PRE/PREA Term burst, Precharging L L L H X AREF/SELF ILLEGAL L L L L Op-Code MRS/EMRS ILLEGAL H X X X X DSL Continue burst to end L H H H X NOP Continue burst to end L H H L X BST ILLEGAL L H L H BA, CA, A10 READ/READA Term burst, start read: Determine AP 6, 7 L H L L BA, CA, A10 WRIT/WRITA Term burst, start read: Determine AP 6 L L H H BA, RA ACT ILLEGAL 3 L L H L BA, A10 PRE/PREA Term burst, Precharging 8 L L L H X AREF/SELF ILLEGAL L L L L Op-Code MRS/EMRS ILLEGAL - 18 - 6 3 Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB Function Truth Table, continued CURRENT STATE Read with Autoprecharge Write with Autoprecharge Precharging Row Activating CS RAS CAS WE ADDRESS COMMAND ACTION NOTES H X X X X DSL Continue burst to end L H H H X NOP Continue burst to end L H H L X BST ILLEGAL L H L H BA, CA, A10 READ/READA ILLEGAL L H L L BA, CA, A10 WRIT/WRITA ILLEGAL 3 L L H H BA, RA ACT ILLEGAL 3 L L H L BA, A10 PRE/PREA ILLEGAL L L L H X AREF/SELF ILLEGAL L L L L Op-Code MRS/EMRS ILLEGAL H X X X X DSL Continue burst to end L H H H X NOP Continue burst to end L H H L X BST ILLEGAL L H L H BA, CA, A10 READ/READA ILLEGAL L H L L BA, CA, A10 WRIT/WRITA ILLEGAL L L H H BA, RA ACT ILLEGAL 3 L L H L BA, A10 PRE/PREA ILLEGAL 3 L L L H X AREF/SELF ILLEGAL L L L L Op-Code MRS/EMRS ILLEGAL H X X X X DSL NOP-> Idle after tRP L H H H X NOP NOP-> Idle after tRP L H H L X BST ILLEGAL L H L H BA, CA, A10 READ/READA ILLEGAL 3 L H L L BA, CA, A10 WRIT/WRITA ILLEGAL 3 L L H H BA, RA ACT ILLEGAL 3 L L H L BA, A10 PRE/PREA Idle after TRP L L L H X AREF/SELF ILLEGAL L L L L Op-Code MRS/EMRS ILLEGAL H X X X X DSL NOP-> Row active after tRCD L H H H X NOP NOP-> Row active after tRCD L H H L X BST ILLEGAL L H L H BA, CA, A10 READ/READA ILLEGAL 3 L H L L BA, CA, A10 WRIT/WRITA ILLEGAL 3 L L H H BA, RA ACT ILLEGAL 3 L L H L BA, A10 PRE/PREA ILLEGAL 3 L L L H X AREF/SELF ILLEGAL L L L L Op-Code MRS/EMRS ILLEGAL - 19 - Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB Function Truth Table, continued CURRENT STATE Write Recovering Write Recovering with Autoprecharge Refreshing Mode Register Accessing ADDRESS COMMAND ACTION NOTES CS RAS CAS H X X X X DSL NOP->Row active after tWR L H H H X NOP NOP->Row active after tWR L H H L X BST ILLEGAL L H L H BA, CA, A10 READ/READA ILLEGAL 3 L H L L BA, CA, A10 WRIT/WRITA ILLEGAL 3 L L H H BA, RA ACT ILLEGAL 3 L L H L BA, A10 PRE/PREA ILLEGAL 3 L L L H X AREF/SELF ILLEGAL WE L L L L Op-Code MRS/EMRS ILLEGAL H X X X X DSL NOP->Enter precharge after tWR L H H H X NOP NOP->Enter precharge after tWR L H H L X BST ILLEGAL L H L H BA, CA, A10 READ/READA ILLEGAL 3 L H L L BA, CA, A10 WRIT/WRITA ILLEGAL 3 L L H H BA, RA ACT ILLEGAL 3 L L H L BA, A10 PRE/PREA ILLEGAL 3 L L L H X AREF/SELF ILLEGAL L L L L Op-Code MRS/EMRS ILLEGAL H X X X X DSL NOP->Idle after tRC L H H H X NOP NOP->Idle after tRC L H H L X BST ILLEGAL L H L H X READ/WRIT ILLEGAL L L H X X ACT/PRE/PREA ILLEGAL L L L X X AREF/SELF/MRS/EMRS ILLEGAL H X X X X DSL NOP->Row after tMRD L H H H X NOP NOP->Row after tMRD L H H L X BST ILLEGAL L H L X X READ/WRIT ILLEGAL L L X X X ACT/PRE/PREA/ARE F/SELF/MRS/EMRS ILLEGAL Notes 1. All entries assume that CKE was active (High level) during the preceding clock cycle and the current clock cycle. 2. Illegal if any bank is not idle. 3. Illegal to bank in specified states; Function may be legal in the bank indicated by Bank Address (BA), depending on the state of that bank. 4. Illegal if tRCD is not satisfied. 5. Illegal if tRAS is not satisfied. 6. Must satisfy burst interrupt condition. 7. Must avoid bus contention, bus turn around, and/or satisfy write recovery requirements. 8. Must mask preceding data which don’t satisfy tWR Remark: H = High level, L = Low level, X = High or Low level (Don’t Care), V = Valid data - 20 - Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB 9.3 Function Truth Table for CKE CURRENT STATE Self Refresh Power Down All banks Idle Row Active Any State Other Than Listed Above CKE n-1 n CS RAS CAS W E ADDRESS ACTION H X X X X X X INVALID L H H X X X X Exit Self Refresh->Idle after tXSNR L H L H H X X Exit Self Refresh->Idle after tXSNR L H L H L X X ILLEGAL L H L L X X X ILLEGAL L L X X X X X Maintain Self Refresh H X X X X X X INVALID L H X X X X X Exit Power down->Idle after tIS NOTES L L X X X X X Maintain power down mode H H X X X X X Refer to Function Truth Table H L H X X X X Enter Power down 2 H L L H H X X Enter Power down 2 H L L L L H X Self Refresh 1 H L L H L X X ILLEGAL H L L L X X X ILLEGAL L X X X X X X Power down H H X X X X X Refer to Function Truth Table H L H X X X X Enter Power down 3 H L L H H X X Enter Power down 3 H L L L L H X ILLEGAL H L L H L X X ILLEGAL H L L L X X X ILLEGAL L X X X X X X Power down H H X X X X X Refer to Function Truth Table Notes 1. Self refresh can enter only from the all banks idle state. 2. Power Down occurs when all banks are idle; this mode is referred to as precharge power down. 3. Power Down occurs when there is a row active in any bank; this mode is referred to as active power down. Remark: H = High level, L = Low level, X = High or Low level (Don’t Care), V = Valid data - 21 - Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB 9.4 Simplified Stated Diagram SELF REFRESH SREF SREFX MRS/EMRS MODE REGISTER SET AREF IDLE AUTO REFRESH PD PDEX ACT POWER DOWN ACTIVE POWERDOWN PDEX PD ROW ACTIVE Write BST Read Write Read Read Write Read Read A Write A Read A Write A Read A PRE Write A POWER APPLIED POWER ON PRE PRE PRE Read A PRE CHARGE Automatic Sequence Command Sequence - 22 - Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB 10. ELECTRICAL CHARACTERISTICS 10.1 Absolute Maximum Ratings PARAMETER SYMBOL RATING UNIT VIN, VOUT -0.5 ~ VDDQ + 0.5 V Voltage on Input Pins Relative to VSS VIN -1 ~ 3.6 V Voltage on VDD Supply Relative to VSS VDD -1 ~ 3.6 Voltage on VDDQ Supply Relative to VSS VDDQ -1 ~ 3.6 Operating Temperature (-4/-5) TOPR 0 ~ 70 °C Operating Temperature (-5I) TOPR -40 ~ 85 °C Storage Temperature TSTG -55 ~ 150 °C TSOLDER 260 °C PD 1 W IOUT 50 mA Voltage on I/O Pins Relative to VSS Soldering Temperature (10s) Power Dissipation Short Circuit Output Current Note: Stresses greater than those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating only, and functional operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect reliability. 10.2 Recommended DC Operating Conditions (TA = 0 to 70°C for -4/-5, TA = -40 to 85°C for -5I) SYM. PARAMETER MIN. TYP. MAX. UNIT NOTES VDD Power Supply Voltage (for -5/-5I) 2.3 2.5 2.7 V 2 VDD Power Supply Voltage (for -4) 2.4 - 2.7 V 2 VDDQ I/O Buffer Supply Voltage (for -5/-5I) 2.3 2.5 2.7 V 2 VDDQ I/O Buffer Supply Voltage (for -4) 2.4 - 2.7 V 2 VREF Input reference Voltage 0.49 x VDDQ 0.50 x VDDQ 0.51 x VDDQ V 2, 3 VTT Termination Voltage (System) VREF - 0.04 VREF VREF + 0.04 V 2, 8 VIH (DC) Input High Voltage (DC) VREF + 0.15 - VDDQ + 0.3 V 2 VIL (DC) Input Low Voltage (DC) -0.3 - VREF - 0.15 V 2 Differential Clock DC Input Voltage -0.3 - VDDQ + 0.3 V 15 0.36 - VDDQ + 0.6 V 13, 15 VICK (DC) VID (DC) Input Differential Voltage. CLK and CLK inputs (DC) VIH (AC) Input High Voltage (AC) VREF + 0.31 - - V 2 VIL (AC) Input Low Voltage (AC) - - VREF - 0.31 V 2 0.7 - VDDQ + 0.6 V 13, 15 Differential AC input Cross Point Voltage VDDQ/2 - 0.2 - VDDQ/2 + 0.2 V 12, 15 Differential Clock AC Middle Point VDDQ/2 - 0.2 - VDDQ/2 + 0.2 V 14, 15 VID (AC) VX (AC) VISO (AC) Input Differential Voltage. CLK and CLK inputs (AC) Notes: VIH (DC) and VIL (DC) are levels to maintain the current logic state. VIH (AC) and VIL (AC) are levels to change to the new logic state. - 23 - Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB 10.3 Capacitance (VDD = VDDQ = 2.5V 0.2V, f = 1 MHz, TA = 25°C, VOUT (DC) = VDDQ/2, VOUT (Peak to Peak) = 0.2V) MIN. MAX. DELTA (MAX.) UNIT Input Capacitance (except for CLK pins) 1.5 2.5 0.5 pF CCLK Input Capacitance (CLK pins) 1.5 2.5 0.25 pF CI/O DQ, DQS, DM Capacitance 3.5 4.5 0.5 pF SYMBOL CIN PARAMETER Notes: These parameters are periodically sampled and not 100% tested. 10.4 Leakage and Output Buffer Characteristics SYMBOL PARAMETER MIN. MAX. UNIT II (L) Input Leakage Current Any input 0V < VIN < VDD, VREF Pin 0V < VIN < 1.35V (All other pins not under test = 0V) -2 2 µA IO (L) Output Leakage Current (Output disabled, 0V < VOUT < VDDQ) -5 5 µA VOH Output High Voltage (under AC test load condition) VTT +0.76 - V VOL Output Low Voltage (under AC test load condition) - VTT -0.76 V IOH Output Levels: Full drive option High Current (VOUT = VDDQ - 0.373V, min. VREF, min. VTT -15 - mA 4, 6 IOL Low Current (VOUT = 0.373V, max. VREF, max. VTT) 15 - mA 4, 6 IOHR Output Levels: Reduced drive option - 60% High Current (VOUT = VDDQ - 0.763V, min. VREF, min. VTT -9 - mA 5 IOLR Low Current (VOUT = 0.763V, max. VREF, max. VTT) 9 - mA 5 NOTES IOHR(30) Output Levels: Reduced drive option - 30% High Current (VOUT = VDDQ – 1.056V, min. VREF, min. VTT -4.5 - mA 5 IOLR(30) Low Current (VOUT = 1.056V, max. VREF, max. VTT) 4.5 - mA 5 - 24 - Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB 10.5 DC Characteristics SYM. MAX. PARAMETER UNIT NOTES -4 -5/-5I 60 55 7 75 65 7, 9 5 5 25 20 15 10 35 30 140 120 7, 9 135 115 7 7 Operating current: One Bank Active-Precharge; IDD0 tRC = tRC min; tCK = tCK min; DQ, DM and DQS inputs changing once per clock cycle; Address and control inputs changing once every two clock cycles Operating current: One Bank Active-Read-Precharge; IDD1 Burst = 4; tRC = tRC min; CL = 3; tCK = tCK min; IOUT = 0 mA; Address and control inputs changing once per clock cycle. Precharge Power Down standby current: IDD2P All Banks Idle; Power down mode; CKE < VIL max; tCK = tCK min; Vin = VREF for DQ, DQS and DM Idle standby current: IDD2N CS > VIH min; All Banks Idle; CKE > VIH min; tCK = tCK min; 7 Address and other control inputs changing once per clock cycle; Vin > VIH min or Vin < VIL max for DQ, DQS and DM Active Power Down standby current: IDD3P One Bank Active; Power down mode; CKE < VIL max; tCK = tCK min; Vin = VREF for DQ, DQS and DM Active standby current: CS > VIH min; CKE > VIH min; One Bank Active-Precharge; IDD3N tRC = tRAS max; tCK = tCK min; mA 7 DQ, DM and DQS inputs changing twice per clock cycle; Address and other control inputs changing once per clock cycle Operating current: IDD4R Burst = 2; Reads; Continuous burst; One Bank Active; Address and control inputs changing once per clock cycle; CL=2; tCK = tCK min; IOUT = 0mA Operating current: Burst = 2; Write; Continuous burst; One Bank Active; IDD4W Address and control inputs changing once per clock cycle; CL = 2; tCK = tCK min; DQ, DM and DQS inputs changing twice per clock cycle IDD5 Auto Refresh current: tRC = tRFC min 75 70 IDD6 Self Refresh current: CKE < 0.2V; external clock on; tCK = tCK min 2 2 170 150 Random Read current: 4 Banks Active Read with activate every 20nS, Auto-Precharge Read every 20 nS; IDD7 Burst = 4; tRCD = 3; IOUT = 0mA; DQ, DM and DQS inputs changing twice per clock cycle; Address changing once per clock cycle - 25 - Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB 10.6 AC Characteristics and Operating Condition SYM. -4 MIN. MAX. 48 60 40 70000 16 16 1 16 12 12 (tWR/tCK) + (tRP/tCK) 4 12 4 12 PARAMETER tRC tRFC tRAS tRCD tRAP tCCD tRP tRRD tWR Active to Ref/Active Command Period Ref to Ref/Active Command Period Active to Precharge Command Period Active to Read/Write Command Delay Time Active to Read with Auto-precharge Enable Read/Write(a) to Read/Write(b) Command Period Precharge to Active Command Period Active(a) to Active(b) Command Period Write Recovery Time tDAL Auto-precharge Write Recovery + Precharge Time CL = 2 CL = 2.5 CL = 3 CL = 4 -5/-5I MIN. MAX. 50 70 40 100000 15 15 1 15 10 15 (tWR/tCK) + (tRP/tCK) 7.5 12 6 12 5 12 - UNIT NOTES nS tCK nS tCK 18 tCK CLK Cycle Time tAC Data Access Time from CLK, CLK -0.65 0.65 -0.7 0.7 16 tDQSCK DQS Output Access Time from CLK, CLK -0.55 0.55 -0.6 0.6 16 tDQSQ tCH tCL Data Strobe Edge to Output Data Edge Skew CLk High Level Width CLK Low Level Width tHP CLK Half Period (minimum of actual tCH, tCL) tQH DQ Output Data Hold Time from DQS DQS Read Preamble Time DQS Read Postamble Time DQ and DM Setup Time to DQS, slew rate 0.5V/nS DQ and DM Hold Time to DQS, slew rate 0.5V/nS DQ and DM Input Pulse Width (for each input) DQS Input High Pulse Width DQS Input Low Pulse Width DQS Falling Edge to CLK Setup Time DQS Falling Edge Hold Time from CLK Clock to DQS Write Preamble Set-up Time DQS Write Preamble Time DQS Write Postamble Time Write Command to First DQS Latching Transition Input Setup Time (fast slew rate) Input Hold Time (fast slew rate) Input Setup Time (slow slew rate) Input Hold Time (slow slew rate) Control & Address Input Pulse Width (for each input) tRPRE tRPST tDS tDH tDIPW tDQSH tDQSL tDSS tDSH tWPRES tWPRE tWPST tDQSS tIS tIH tIS tIH tIPW 0.45 0.45 min (tCL,tCH) tHP-0.5 0.9 0.4 0.4 0.4 1.75 0.35 0.35 0.2 0.2 0 0.25 0.4 0.85 0.6 0.6 0.7 0.7 2.2 0.4 0.55 0.55 1.1 0.6 0.6 1.15 0.45 0.45 Min, (tCL,tCH) tHP-0.5 0.9 0.4 0.4 0.4 1.75 0.35 0.35 0.2 0.2 0 0.25 0.4 0.75 0.6 0.6 0.7 0.7 2.2 1.1 0.6 tCK tCK 11 11 nS 0.6 1.25 tCK 11 19, 21-23 19, 21-23 20-23 20-23 nS tLZ Data-out Low-impedance Time from CLK, CLK -0.7 0.7 -0.7 0.7 SSTL Input Transition Internal Write to Read Command Delay Exit Self Refresh to non-Read Command Exit Self Refresh to Read Command Refresh Interval Time (4K/ 64mS) Mode Register Set Cycle Time 0.5 2 72 200 1.5 0.5 2 75 200 1.5 0.7 15.6 - 26 - 11 nS Data-out High-impedance Time from CLK, CLK 8 tCK nS tHZ tT(SS) tWTR tXSNR tXSRD tREFI tMRD 0.7 0.4 0.55 0.55 nS 15.6 10 tCK nS tCK µS nS 17 Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB 10.7 AC Test Conditions PARAMETER SYMBOL VALUE UNIT Input High Voltage (AC) VIH VREF + 0.31 V Input Low Voltage (AC) VIL VREF - 0.31 V Input Reference Voltage VREF 0.5 x VDDQ V Termination Voltage VTT 0.5 x VDDQ V Differential Clock Input Reference Voltage VR Vx (AC) V VID (AC) 1.5 V VOTR 0.5 x VDDQ V Input Difference Voltage. CLK and CLK Inputs (AC) Output Timing Measurement Reference Voltage VTT VDDQ VIH min (AC) V SWING (MAX) VREF 50 Ω VIL max (AC) VSS T T Output Output V(out) 30pF SLE W = (VIH min (AC) - VILmax (AC)) / T Timing Reference Load Notes: (1) Conditions outside the limits listed under “Absolute Maximum Ratings” may cause permanent damage to the device. (2) All voltages are referenced to VDD, VDDQ. (3) Peak to peak AC noise on VREF may not exceed 2% VREF(DC). (4) VOH = 1.95V, VOL = 0.35V (5) VOH = 1.9V, VOL = 0.4V (6) The values of IOH(DC) is based on VDDQ = 2.3V and VTT = 1.19V. The values of IOL(DC) is based on VDDQ = 2.3V and VTT = 1.11V. (7) These parameters depend on the cycle rate and these values are measured at a cycle rate with the minimum values of tCK and tRC. (8) VTT is not applied directly to the device. VTT is a system supply for signal termination resistors is expected to be set equal to VREF and must track variations in the DC level of VREF. (9) These parameters depend on the output loading. Specified values are obtained with the output open. (10) Transition times are measured between VIH min(AC) and VIL max(AC).Transition (rise and fall) of input signals have a fixed slope. (11) IF the result of nominal calculation with regard to Tck contains more than one decimal place, the result is rounded up to the nearest decimal place. (i.e., tDQSS = 1.25 tCK, tCK = 5 nS, 1.25 5 nS = 6.25 nS is rounded up to 6.2 nS.) - 27 - Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB (12) VX is the differential clock cross point voltage where input timing measurement is referenced. (13) VID is magnitude of the difference between CLK input level and CLK input level. (14) VISO means {VICK(CLK)+VICK( CLK )}/2. (15) Refer to the figure below. CLK VX VX VX VICK VX VICK VX VID(AC) CLK VICK VICK VSS VID(AC) 0 V Differential VISO VISO(min) VISO(max) VSS (16) tAC and tDQSCK depend on the clock jitter. These timing are measured at stable clock. (17) A maximum of eight AUTO REFRESH commands can be posted to any given DDR SDRAM device. (18) tDAL = (tWR/tCK) + (tRP/tCK) For each of the terms above, if not already an integer, round to the next highest integer. Example: For -5 speed grade at CL=2.5 and tCK=6 nS tDAL = ((15 nS / 6 nS) + (15 nS / 6 nS)) clocks = ((3) + (3)) clocks = 6 clocks (19) For command/address input slew rate ≥1.0 V/nS. (20) For command/address input slew rate ≥0.5 V/nS and <1.0 V/nS. (21) For CLK & CLK slew rate ≥1.0 V/nS (single--ended). (22) These parameters guarantee device timing, but they are not necessarily tested on each device. They may be guaranteed by device design or tester correlation. (23) Slew Rate is measured between VOH(ac) and VOL(ac). - 28 - Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB 11. SYSTEM CHARACTERISTICS FOR DDR SDRAM The following specification parameters are required in systems using DDR500 & DDR400 devices to ensure proper system performance. These characteristics are for system simulation purposes and are guaranteed by design. 11.1 Table 1: Input Slew Rate for DQ, DQS, and DM AC CHARACTERISTICS SYMBOL PARAMETER DQ/DM/DQS input slew rate measured between VIH(DC), VIL(DC) and VIL(DC), VIH(DC) DCSLEW DDR500 DDR400 MIN. MAX. MIN. MAX. 0.5 4.0 0.5 4.0 UNIT NOTES V/nS a, m 11.2 Table 2: Input Setup & Hold Time Derating for Slew Rate INPUT SLEW RATE ΔtIS ΔtIH UNIT NOTES 0.5 V/nS 0 0 pS i 0.4 V/nS +50 0 pS i 0.3 V/nS +100 0 pS i 11.3 Table 3: Input/Output Setup & Hold Time Derating for Slew Rate INPUT SLEW RATE ΔtDS ΔtDH UNIT NOTES 0.5 V/nS 0 0 pS k 0.4 V/nS +75 0 pS k 0.3 V/nS +150 0 pS k 11.4 Table 4: Input/Output Setup & Hold Derating for Rise/Fall Delta Slew Rate INPUT SLEW RATE ΔtDS ΔtDH UNIT NOTES 0.0 nS/V 0 0 pS j 0.25 nS/V +50 0 pS j 0.5 nS/V +100 0 pS j 11.5 Table 5: Output Slew Rate Characteristics (X16 Devices only) SLEW RATE CHARACTERISTIC TYPICAL RANGE (V/NS) MINIMUM (V/NS) MAXIMUM (V/NS) NOTES Pullup Slew Rate 1.2 ~ 2.5 0.7 5.0 a, c, d, f, g, h Pulldown Slew Rate 1.2 ~ 2.5 0.7 5.0 b, c, d, f, g, h - 29 - Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB 11.6 Table 6: Output Slew Rate Matching Ratio Characteristics SLEW RATE CHARACTERISTIC DDR500 DDR400 PARAMETER MIN. MAX. MIN. MAX. Output Slew Rate Matching Ratio (Pullup to Pulldown) 0.67 1.5 0.67 1.5 NOTES e, m 11.7 Table 7: AC Overshoot/Undershoot Specification for Address and Control Pins SPECIFICATION PARAMETER DDR500 DDR400 Maximum peak amplitude allowed for overshoot 1.5 V 1.5 V Maximum peak amplitude allowed for undershoot 1.5 V 1.5 V The area between the overshoot signal and VDD must be less than or equal to Max. area in Figure 1 4.5 V-nS 4.5 V-nS The area between the undershoot signal and GND must be less than or equal to Max. area in Figure 1 4.5 V-nS 4.5 V-nS VDD Overshoot 5 Max. amplitude = 1.5V 4 3 2 Volts (V) Max. area 1 0 -1 -2 -3 Max. amplitude = 1.5V GND -4 -5 0 0.5 0.68751.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.06.3125 6.5 7.0 Time (nS) Undershoot Figure 1: Address and Control AC Overshoot and Undershoot Definition - 30 - Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB 11.8 Table 8: Overshoot/Undershoot Specification for Data, Strobe, and Mask Pins SPECIFICATION PARAMETER DDR500 DDR400 Maximum peak amplitude allowed for overshoot 1.2 V 1.2 V Maximum peak amplitude allowed for undershoot 1.2 V 1.2 V The area between the overshoot signal and VDD must be less than or equal to Max. area in Figure 2 2.4 V-nS 2.4 V-nS The area between the undershoot signal and GND must be less than or equal to Max. area in Figure 2 2.4 V-nS 2.4 V-nS VDD Overshoot 5 Max. amplitude = 1.2V 4 3 2 Volts (V) Max. area 1 0 -1 -2 Max. amplitude = 1.2V -3 GND -4 -5 0 0.5 1.0 1.42 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 5.68 6.0 6.5 7.0 Time (nS) Undershoot Figure 2: DQ/DM/DQS AC Overshoot and Undershoot Definition - 31 - Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB 11.9 System Notes: a. Pullup slew rate is characterized under the test conditions as shown in Figure 3. Test point Output 50Ω VSSQ Figure 3: Pullup slew rate test load b. Pulldown slew rate is measured under the test conditions shown in Figure 4. VDDQ 50Ω Output Test point Figure 4: Pulldown slew rate test load c. Pullup slew rate is measured between (VDDQ/2 - 320 mV ± 250 mV) Pulldown slew rate is measured between (VDDQ/2 + 320 mV ± 250 mV) Pullup and Pulldown slew rate conditions are to be met for any pattern of data, including all outputs switching and only one output switching. Example: For typical slew rate, DQ0 is switching For minimum slew rate, all DQ bits are switching worst case pattern For maximum slew rate, only one DQ is switching from either high to low, or low to high The remaining DQ bits remain the same as for previous state d. Evaluation conditions Typical: 25C (T Ambient), VDDQ = nominal, typical process Minimum: 70C (T Ambient), VDDQ = minimum, slow-slow process Maximum: 0C (T Ambient), VDDQ = maximum, fast-fast process - 32 - Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB e. The ratio of pullup slew rate to pulldown slew rate is specified for the same temperature and voltage, over the entire temperature and voltage range. For a given output, it represents the maximum difference between pullup and pulldown drivers due to process variation. f. Verified under typical conditions for qualification purposes. g. TSOP II package devices only. h. Only intended for operation up to 266 Mbps per pin. i. A derating factor will be used to increase tIS and tIH in the case where the input slew rate is below 0.5 V/nS as shown in Table 2. The Input slew rate is based on the lesser of the slew rates determined by either VIH(AC) to VIL(AC) or VIH(DC) to VIL(DC), similarly for rising transitions. j. A derating factor will be used to increase tDS and tDH in the case where DQ, DM, and DQS slew rates differ, as shown in Tables 3 & 4. Input slew rate is based on the larger of AC-AC delta rise, fall rate and DC-DC delta rise, fall rate. Input slew rate is based on the lesser of the slew rates determined by either VIH(AC) to VIL(AC) or VIH(DC) to VIL(DC), similarly for rising transitions. The delta rise/fall rate is calculated as: {1/(Slew Rate1)}-{1/(slew Rate2)} For example: If Slew Rate 1 is 0.5 V/nS and Slew Rate 2 is 0.4 V/nS, then the delta rise, fall rate is -0.5 nS/V. Using the table given, this would result in the need for an increase in tDS and tDH of 100 pS. k. Table 3 is used to increase tDS and tDH in the case where the I/O slew rate is below 0.5 V/nS. The I/O slew rate is based on the lesser of the AC-AC slew rate and the DC-DC slew rate. The input slew rate is based on the lesser of the slew rates determined by either VIH(AC) to VIL(AC) or VIH(DC) to VIL(DC), and similarly for rising transitions. m. DQS, DM, and DQ input slew rate is specified to prevent double clocking of data and preserve setup and hold times. Signal transitions through the DC region must be monotonic. - 33 - Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB 12. TIMING WAVEFORMS 12.1 Command Input Timing tCK tCK tCH tCL CLK CLK tIS tIH tIS tIH tIS tIH tIS tIH tIS tIH CS RAS CAS WE A0~A11 BA0,1 Refer to the Command Truth Table 12.2 Timing of the CLK Signals tCH tCL CLK CLK tT tT VIH VIH(AC) VIL(AC) VIL tCK CLK VIH VIL CLK VX VX - 34 - VX Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB 12.3 Read Timing (Burst Length = 4) tCH tCL tCK CLK CLK tIH tIS CMD READ tIH tIS ADD Col tDQSCK tDQSCK tRPST tDQSCK CAS Latency = 2 tRPRE Hi-Z DQS Hi-Z Preamble tDQSQ tQH QA0 DA0 QA1 DA1 tQH Postamble tDQSQ tDQSQ QA2 DA2 QA3 DA3 Hi-Z Output (Data) Hi-Z tAC tHZ tDQSCK tLZ tDQSCK tDQSCK tRPRE CAS Latency = 3 tRPST Hi-Z Hi-Z DQS Preamble tDQSQ tQH QA0 DA0 QA1 DA1 tQH Postamble tDQSQ tDQSQ QA2 DA2 QA3 DA3 Hi-Z Output (Data) Hi-Z tAC tLZ tHZ Notes: The correspondence of LDQS, UDQS to DQ. (W9412G6JB) LDQS DQ0~7 UDQS DQ8~15 - 35 - Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB 12.4 Write Timing (Burst Length = 4) tCH tCL tCK CLK CLK tIS CMD tIH WRIT tIS ADD x4, x8 device tIH tDSH tDSS tDSH tDSS tDQSH tDQSL tDQSH tWPST Col tWPRES tWPRE DQS Postamble Preamble tDS tDS tDS tDH Input (Data) DA0 DA1 tDQSS x16 device tDH tWPRES tDH DA2 DA3 tDSH tDSS tDSH tDSS tDQSH tDQSL tDQSH tWPST tWPRE LDQS Postamble Preamble tDS tDS DA0 tDH tDH tDH DQ0~7 tDS DA1 DA2 DA3 tDQSS tDSH tWPRES tDSS tDSH tDQSL tDQSH tDSS tDQSH tWPST tWPRE UDQS Preamble tDS tDH tDH DQ8~15 tDS Postamble tDS DA0 DA1 DA2 tDH DA3 tDQSS Note: x16 has two DQSs (UDQS for upper byte and LDQS for lower byte). Even if one of the 2 bytes is not used, both UDQS and LDQS must be toggled. - 36 - Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB 12.5 DM, DATA MASK (W9412G6JB) CLK CLK CMD WRIT LDQS tDS tDS tDH tDH LDM tDIPW DQ0~DQ7 D0 D1 tDIPW D3 Masked UDQS tDS tDS tDH tDH UDM tDIPW DQ8~DQ15 D2 D0 Masked D3 tDIPW - 37 - Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB 12.6 Mode Register Set (MRS) Timing CLK CLK tMRD CMD MRS ADD Register Set data NEXT CMD Burst Length A0 Burst Length A1 A2 Addressing Mode A3 A4 A5 CAS Latency A2 A1 A0 Sequential Interleaved 0 0 0 Reserved Reserved 0 0 1 2 2 0 1 0 4 4 0 1 1 8 8 1 0 0 Reserved Reserved 1 0 1 1 1 0 1 1 1 A6 A7 "0" A8 A9 A10 A11 Addressing Mode A3 Reserved DLL Reset "0" "0" Reserved "0" BA0 "0" BA1 "0" Mode Register Set or Extended Mode Register Set 0 Sequential 1 Interleaved CAS Latency A6 A5 A4 0 0 0 0 0 1 0 1 0 2 3 Reserved 0 1 1 1 0 0 4 1 0 1 Reserved 1 1 0 2.5 1 1 1 Reserved DLL Reset A8 * "Reserved" should stay "0" during MRS cycle. - 38 - 0 No 1 Yes BA1 BA0 MRS or EMRS 0 0 Regular MRS cycle 0 1 Extended MRS cycle 1 0 1 1 Reserved Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB 12.7 Extend Mode Register Set (EMRS) Timing CLK CLK tMRD CMD EMRS ADD Register Set data A0 NEXT CMD A1 Buffer Strength A2 "0" A3 "0" A4 "0" Reserved A5 "0" A6 "0" A7 "0" A8 "0" Buffer Strength Reserved A9 "0" A10 "0" A11 "0" BA0 "0" BA1 "0" DLL Switch A0 DLL Switch 0 Enable 1 Disable A6 A1 Buffer Strength 0 0 100% Strength 0 1 60% Strength 1 0 Reserved 1 1 30% Strength BA1 BA0 MRS or EMRS 0 0 Regular MRS cycle 0 1 Extended MRS cycle 1 0 1 1 Mode Register Set or Extended Mode Register Set * "Reserved" should stay "0" during EMRS cycle. - 39 - Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB 12.8 Auto-precharge Timing (Read Cycle, CL = 2) 1) tRCD (READA) tRAS (min) – (BL/2) tCK tRAS tRP CLK CLK BL=2 CMD ACT READA ACT AP DQS DQ Q0 Q1 BL=4 CMD ACT READA AP ACT DQS DQ Q0 Q1 Q2 Q3 BL=8 CMD ACT AP READA ACT DQS DQ Q0 Q1 Q2 Q3 Q4 Q5 Q6 Q7 Notes: CL=2 shown; same command operation timing with CL = 2,5 and CL=3 In this case, the internal precharge operation begin after BL/2 cycle from READA command. AP Represents the start of internal precharging. The Read with Auto-precharge command cannot be interrupted by any other command. - 40 - Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB 12.9 Auto-precharge Timing (Read cycle, CL = 2), continued 2) tRCD/RAP(min) tRCD (READA) tRAS (min) – (BL/2) tCK tRAS tRP CLK CLK BL=2 CMD ACT READA AP ACT AP ACT tRAP tRCD DQS DQ Q0 Q1 BL=4 CMD ACT READA tRAP tRCD DQS DQ Q0 Q1 Q2 Q3 BL=8 CMD ACT READA AP ACT tRAP tRCD DQS DQ Q0 Q1 Q2 Q3 Q4 Q5 Q6 Q7 Notes: CL2 shown; same command operation timing with CL = 2.5, CL=3. In this case, the internal precharge operation does not begin until after tRAS(min) has command. AP Represents the start of internal precharging. The Read with Auto-precharge command cannot be interrupted by any other command. - 41 - Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB 12.10 Auto-precharge Timing (Write Cycle) CLK CLK tDAL BL=2 CMD WRITA AP ACT DQS DQ D0 D1 tDAL BL=4 CMD WRITA AP ACT DQS DQ D0 D1 D2 D3 tDAL BL=8 CMD WRITA AP ACT DQS DQ D0 D1 D2 D3 D4 D5 D6 D7 The Write with Auto-precharge command cannot be interrupted by any other command. AP Represents the start of internal precharging. - 42 - Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB 12.11 Read Interrupted by Read (CL = 2, BL = 2, 4, 8) CLK CLK CMD ACT READ A tRCD ADD READ B tCCD tCCD Row Address COl,Add,A READ C Col,Add,B READ D tCCD Col,Add,C READ E tCCD Col,Add,D Col,Add,E DQS DQ QA0 QA1 QB0 QB1 QC0 12.12 Burst Read Stop (BL = 8) CLK CLK CMD READ BST CAS Latency = 2 DQS CAS Latency DQ Q0 Q1 Q2 Q3 Q4 Q5 CAS Latency = 3 DQS CAS Latency DQ Q0 Q1 Q2 Q3 - 43 - Q4 Q5 Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB 12.13 Read Interrupted by Write & BST (BL = 8) CLK CLK CAS Latency = 2 CMD BST READ WRIT DQS DQ Q0 Q1 Q2 Q3 Q4 Q5 D0 D1 D2 D3 D4 D5 D6 D7 Burst Read cycle must be terminated by BST Command to avoid I/O conflict. 12.14 Read Interrupted by Precharge (BL = 8) CLK CLK CMD READ PRE CAS Latency = 2 DQS CAS Latency DQ Q0 Q1 Q2 Q3 Q4 Q5 CAS Latency = 3 DQS CAS Latency DQ Q0 Q1 Q2 - 44 - Q3 Q4 Q5 Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB 12.15 Write Interrupted by Write (BL = 2, 4, 8) CLK CLK CMD ACT WRIT A tRCD ADD WRIT B tCCD Row Address COl. Add. A WRIT C tCCD Col.Add.B WRIT D tCCD Col. Add. C WRIT E tCCD Col. Add. D Col. Add. E DQS DQ DA0 DA1 DB0 DB1 DC0 DC1 DD0 DD1 12.16 Write Interrupted by Read (CL = 2, BL = 8) CLK CLK CMD WRIT READ DQS DM tWTR DQ D0 D1 D2 D3 Data must be masked by DM D4 D5 D6 D7 Q0 Q1 Q2 Q3 Q4 Q5 Q6 Q7 Data masked by READ command, DQS input ignored. - 45 - Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB 12.17 Write Interrupted by Read (CL = 3, BL = 4) CLK CLK CMD WRIT READ DQS DM tWTR DQ D0 D1 D2 D3 Q0 Q1 Q2 Q3 Data must be masked by DM 12.18 Write Interrupted by Precharge (BL = 8) CLK CLK CMD WRIT PRE ACT tWR tRP DQS DM DQ D0 D1 D2 D3 D4 D5 Data must be masked by DM D6 D7 Data masked by PRE command, DQS input ignored. - 46 - Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB 12.19 2 Bank Interleave Read Operation (CL = 2, BL = 2) CLK CLK tRC(b) tRC(a) tRRD CMD tRRD ACTa ACTb READAa READAb tRCD(a) tRAS(a) ACTa ACTb tRP(a) tRCD(b) tRAS(b) tRP(b) DQS Preamble Postamble CL(a) DQ Q0a ACTa/b : Bank Act. CMD of bank a/b READAa/b : Read with Auto Pre.CMD of bank a/b APa/b : Auto Pre. of bank a/b Preamble Postamble CL(b) APa Q1a Q0b Q1b APb 12.20 2 Bank Interleave Read Operation (CL = 2, BL = 4) CLK CLK tRC(b) tRC(a) tRRD tRRD CMD ACTa ACTb READAa READAb ACTa ACTb tRCD(a) tRP(a) tRAS(a) tRCD(b) tRP(b) tRAS(b) DQS Preamble Postamble CL(b) CL(a) DQ Q0a Q1a Q2a Q3a Q0b Q1b Q2b Q3b ACTa/b : Bank Act. CMD of bank a/b READAa/b : Read with Auto Pre.CMD of bank a/b APa/b : Auto Pre. of bank a/b - 47 - APa APb Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB 12.21 4 Bank Interleave Read Operation (CL = 2, BL = 2) CLK CLK tRC(a) tRRD CMD tRRD ACTa ACTb tRRD ACTc READAa tRRD ACTd READAb ACTa READAc tRCD(a) tRAS(a) tRP tRCD(b) tRAS(b) tRCD(c) tRAS(c) tRCD(d) tRAS(d) DQS Preamble Postamble CL(a) DQ Q0a Q1a ACTa/b/c/d : Bank Act. CMD of bank a/b/c/d READAa/b/c/d : Read with Auto Pre.CMD of bank a/b/c/d APa/b/c/d : Auto Pre. of bank a/b/c/d Preamble CL(b) Q0b Q1b APb APa 12.22 4 Bank Interleave Read Operation (CL = 2, BL = 4) CLK CLK tRC(a) tRRD tRRD CMD ACTa ACTb READAa tRRD ACTc READAb tRRD ACTd READAc ACTa READAd tRCD(a) tRP(a) tRAS(a) tRCD(b) tRAS(b) tRCD(c) tRAS(c) tRCD(d) tRAS(d) DQS Preamble CL(a) DQ CL(b) CL(c) Q0a Q1a Q0a Q1a Q2a Q3a Q0b Q1b Q2b Q3b ACTa/b/c/d : Bank Act. CMD of bank a/b/c/d READAa/b/c/d : Read with Auto Pre.CMD of bank a/b/c/d APa/b/c/d : Auto Pre. of bank a/b/c/d APa - 48 - APb APc Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB 12.23 Auto Refresh Cycle CLK CLK PREA CMD NOP AREF NOP AREF tRFC tRP CMD NOP tRFC Note: CKE has to be kept “High” level for Auto-Refresh cycle. 12.24 Precharged/Active Power Down Mode Entry and Exit Timing CLK CLK tIH tIS tIH tCK tIS CKE Precharge/Activate Note 1,2 Entry CMD CMD Exit NOP NOP CMD NOP Note: 1. If power down occurs when all banks are idle, this mode is referred to as precharge power down. 2. If power down occurs when there is a row active in any bank, this mode is referred to as active power down. 12.25 Input Clock Frequency Change during Precharge Power Down Mode Timing CLK CLK CMD NOP NOP NOP NOP NOP CMD tIS Frequency Change Occurs here CKE DLL RESET 200 clocks tRP Minmum 2 clocks required before changing frequency Stable new clock before power down exit - 49 - Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB 12.26 Self Refresh Entry and Exit Timing CLK CLK tIH tIS tIH tIS CKE CMD PREA NOP SELF SELEX Entry Exit NOP CMD tRP tXSNR tXSRD SELF SELFX Entry Exit NOP ACT NOP READ NOP Note: If the clock frequency is changed during self refresh mode, a DLL reset is required upon exit. - 50 - Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB 13. PACKAGE SPECIFICATION Package Outline TFBGA 60 Ball (8x13 mm2, Ball pitch: 0.8mm, Φ=0.45mm) B A E E1 A pin1 index A1 X’ D1 X D eD eE CCC C 60x Φb REF. A A1 Φb D E D1 E1 eD eE CCC C Dimension in mm MIN. NOM. MAX. ----1.20 0.40 0.25 ----0.40 0.50 12.90 13.00 13.10 7.90 8.00 8.10 11.0 BSC 6.40 BSC 1.00 BSC 0.80 BSC ----0.10 Ball Land Dimension in inch MIN. NOM. MAX. ----0.0471 0.0157 0.0098 ----0.0157 0.0196 0.5157 0.5118 0.5078 0.3110 0.3188 0.3149 0.4330 BSC 0.2519 BSC 0.0393 BSC 0.0314 BSC --0.0039 --- Ball Opening Note: 1. Ball Land: 0.5mm, Ball Opening : 0.4mm, PCB Ball Land Suggested ≤ 0.4mm 2. Solder Ball diameter refers to post reflew condition - 51 - Publication Release Date: Oct. 04, 2012 Revision A02 W9412G6JB 14. REVISION HISTORY VERSION DATE PAGE DESCRIPTION A01 Jul. 27, 2012 All Initial formally data sheet A02 Oct. 04, 2012 51 Update TFBGA 60 ball package outline spec Important Notice Winbond products are not designed, intended, authorized or warranted for use as components in systems or equipment intended for surgical implantation, atomic energy control instruments, airplane or spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments, or for other applications intended to support or sustain life. Further more, Winbond products are not intended for applications wherein failure of Winbond products could result or lead to a situation wherein personal injury, death or severe property or environmental damage could occur. Winbond customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Winbond for any damages resulting from such improper use or sales. - 52 - Publication Release Date: Oct. 04, 2012 Revision A02