TS79M00 Series 3-Terminal 500mA Negative Voltage Regulator TO-220 TO-252 (DPAK) Pin Definition: 1. Ground 2. Input (tab) 3. Output General Description The TS79M00 series of fixed output negative voltage regulators are intended as complements to the popular TS78M00 series device. These negative regulators are available in the same seven-voltage options as the TS7900 devices. In addition, one extra voltage option commonly employed in MECL systems is also available in the negative TS79M00 Series. Available in fixed output voltage options from -5.0 to -24 volts, these regulators employ current limiting, thermal shutdown, and safe-area compensation--making them remarkably rugged under most operating conditions. With adequate heat sinking they can deliver output currents in excess of 0.5 ampere. Features Standard Application Circuit ● Output Voltage: -5 & -12V ● ● Output current up to 0.5A No external components required ● Internal thermal overload protection ● ● Internal short-circuit current limiting Output transistor safe-area compensation ● Output voltage offered in 4% tolerance Ordering Information Part No. TS79MxxCZ C0 Package Packing TO-220 50pcs / Tube TS79MxxCP RO TO-252 2.5Kpcs / 13” Reel Note: Refer to detail ordering information table. A common ground is required between the input and the output voltages. The input voltage must remain typically 2.0V above the output voltage even during the low point on the Input ripple voltage. XX = these two digits of the type number indicate voltage. * = Cin is required if regulator is located an appreciable distance from power supply filter. ** = Co is not needed for stability; however, it does improve transient response. Absolute Maximum Ratings (TA = 25ºC unless otherwise noted) Parameter Symbol Limit Unit Input Voltage VIN -35 V Power Dissipation PD Internal Limited Operating Junction Temperature TJ Storage Temperature Range Thermal Resistance - Junction to Case Thermal Resistance - Junction to Ambient TSTG TO-220 TO-252 TO-220 TO-252 RӨJC RӨJA W 0~+125 o -65~+150 o 5 6 65 92 C C o C/W o C/W Note: Follow the derating curve 1/7 Version: D14 TS79M00 Series 3-Terminal 500mA Negative Voltage Regulator TS79M05 Electrical Characteristics (VIN=-10V, IOUT=350mA, 0 C≤TJ≤125 C, CIN=0.33µF, COUT=0.1µF; unless otherwise specified.) o Parameter o Symbol Test Condition o TJ=25 C Output voltage VOUT Line Regulation REGLINE Load Regulation REGLOAD Quiescent Current IQ Quiescent Current Change ∆IQ Output Noise Voltage Ripple Rejection Ratio Voltage Drop Peak Output Current Temperature Coefficient of Output Voltage VN RR VDROP Io peak ∆VOUT/ ∆TJ -7.5V≤VIN≤-20V, 5mA≤IOUT≤500mA, PD≤5W -7.5V≤VIN≤-25V o TJ=25 C -8V≤VIN≤-18V 5mA≤IOUT≤500mA o TJ=25 C 250mA≤IOUT≤200mA o IOUT=0, TJ=25 C -7.5V≤VIN≤-25V 5mA≤IOUT≤500mA o 10Hz≤f≤100KHz, TJ=25 C f=120Hz, -8V≤VIN≤-18V o IOUT=500mA, TJ=25 C o TJ=25 C IOUT=5mA, 0 C≤TJ≤125 C o o Min Typ Max Unit -4.80 -5 -5.20 -4.75 -5 -5.25 --------54 --- 7 2 20 10 4 --40 66 2 2.1 50 30 100 50 8 1 0.5 ----- -- -0.1 -- mV/ C Unit V mV mA µV dB V A o TS79M12 Electrical Characteristics (VIN=-19V, IOUT=350mA, 0 C≤TJ≤125 C, CIN=0.33µF, COUT=0.1µF; unless otherwise specified.) o Parameter o Symbol Test Condition o TJ=25 C Output voltage VOUT Line Regulation REGLINE Load Regulation Quiescent Current Quiescent Current Change REGLOAD IQ ∆IQ -14.5V≤VIN≤-27V, 5mA≤IOUT≤500mA, PD≤5W -14.5V≤VIN≤-30V o TJ=25 C -15V≤VIN≤-19V 5mA≤IOUT≤500mA o TJ=25 C 250mA≤IOUT≤200mA o TJ=25 C, IOUT=0 -14.5V≤VIN≤-30V 5mA≤IOUT≤500mA o 10Hz≤f≤100KHz, TJ=25 C f=120Hz, -15V≤VIN≤-25V o IOUT=500mA, TJ=25 C o TJ=25 C Min Typ Max -11.53 -12 -12.48 -11.42 -12 -12.60 --------55 --- 10 3 12 4 4.3 --75 70 2 2.1 240 120 240 120 8 1 0.5 ----- V mV mA Output Noise Voltage µV VN Ripple Rejection Ratio dB RR Voltage Drop V VDROP Peak Output Current A Io peak Temperature Coefficient of o o o --1 -mV/ C ∆VOUT/ ∆TJ IOUT=5mA, 0 C≤TJ≤125 C Output Voltage Pulse testing techniques are used to maintain the junction temperature as close to the ambient temperature as possible, and thermal effects must be taken into account separately. This specification applies only for DC power dissipation permitted by absolute maximum ratings. . 2/7 Version: D14 TS79M00 Series 3-Terminal 500mA Negative Voltage Regulator Electrical Characteristics Curves Figure 1. Worse Case Power Dissipation vs. Ambient Temperature (TO-220) Figure 2. Peak Output Current as a Function of Input-Output Differential Voltage Figure 3. Bias Current vs. Input Voltage Figure 4. Bias Current vs. Output Current Figure 5. Ripple Rejection vs. Frequency Figure 6. Ripple Rejection vs. Output Voltage 3/7 Version: D14 TS79M00 Series 3-Terminal 500mA Negative Voltage Regulator Application information Figure 7. DPAK Thermal Resistance and Maximum Power Dissipation vs. P.C.B Copper Length Ordering information Voltage TO-220 TO-252 5V TS79M05CZ C0 TS79M05CP RO 12V TS79M12CP RO Packing code information Packing 50pcs / Tube 2.5kpcs / 13" Reel 4/7 Version: D14 TS79M00 Series 3-Terminal 500mA Negative Voltage Regulator TO-220 Mechanical Drawing Unit: Millimeters Marking Diagram XX Y M L CZ = Output Voltage (05=-5V) = Year Code = Month Code (A=Jan, B=Feb, C=Mar, D=Apl, E=May, F=Jun, G=Jul, H=Aug, I=Sep, J=Oct, K=Nov, L=Dec) = Lot Code = Package Code for TO-220 5/7 Version: D14 TS79M00 Series 3-Terminal 500mA Negative Voltage Regulator TO-252 Mechanical Drawing Unit: Millimeters Marking Diagram XX Y M L CP = Output Voltage (05=-5V, 12=-12V) = Year Code = Month Code (A=Jan, B=Feb, C=Mar, D=Apl, E=May, F=Jun, G=Jul, H=Aug, I=Sep, J=Oct, K=Nov, L=Dec) = Lot Code = Package Code for TO-252 6/7 Version: D14 TS79M00 Series 3-Terminal 500mA Negative Voltage Regulator Notice Specifications of the products displayed herein are subject to change without notice. TSC or anyone on its behalf, assumes no responsibility or liability for any errors or inaccuracies. Information contained herein is intended to provide a product description only. No license, express or implied, to any intellectual property rights is granted by this document. Except as provided in TSC’s terms and conditions of sale for such products, TSC assumes no liability whatsoever, and disclaims any express or implied warranty, relating to sale and/or use of TSC products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright, or other intellectual property right. The products shown herein are not designed for use in medical, life-saving, or life-sustaining applications. Customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify TSC for any damages resulting from such improper use or sale. 7/7 Version: D14