Product Information

SmartPro Medical Grade .7kVA 120V Line
interactive Tower UPS, full isolation, USB & Serial
ports
Highlights
700VA line interactive tower UPS
Maintains 120V nominal output
over an input range of 82 to 142V
Professional features include
MODEL NUMBER: SMART700HG
serial port, hospital grade plug &
outlets, built-in isolation
transformer and UL60601-1 listing
Input: NEMA 5-15P (120V 15A) /
Output: 4 NEMA 5-15R (120V)
Leakage current less than 100
microamps
Package Includes
SMART 700HG Medical Grade
UPS System
One USB and One DB9
monitoring cable
Warranty information
Instruction manual
Description
Tripp Lite's SMART 700HG offers medical-grade UPS protection with built-in line interactive voltage regulation, intelligent monitoring and unattended shutdown
capability. UL 60601-1 listed as medical electrical equipment. Built-in isolation transformer with Faraday shield removes common mode noise while
maintaining full AC surge suppression in all modes less than 100 microamps. Resistant to electrostatic discharge. Includes high quality hospital-grade plug and
outlets. 700VA power handling capacity supports computers, inter-networking equipment and other critical loads during commercial power failures. Line
interactive voltage regulation corrects brownouts as low as 81V and overvoltages as high as 143 back to normal 120V levels, saving battery reserves for use
only during complete power failures. Includes 4 outlets, diagnostic LEDs and built-in USB & RS-232 communications ports that work with downloadable
PowerAlert Software and cabling to provide automatic unattended shutdown of connected network and PC applications.
Features
Ideal UPS protection for applications in medical patient-care areas where UL 60601-1 listed medical electrical equipment is required
Built-in isolation transformer with Faraday shield offers full isolation and removes common mode noise while maintaining full AC surge suppression in all
modes
Line-interactive voltage regulation corrects brownouts and overvoltages from 81 to 143 volts back to usable 120V output levels, without using battery
power
Hospital-grade plug and outlets offer added degree of safety and reliability to input/output connections
Full line isolation offers a higher degree of safety and prevents operational problems in sensitive electronic equipment
Resistant to electrostatic discharge
Supports loads up to 700VA/450 watts
42 minutes half load runtime (with 350VA load), 18 minutes full load runtime (with 700VA load)
4 protected hospital-grade outlets; 6-ft. cord
RS-232 and USB monitoring ports for remote monitoring and unattended shutdown
PowerAlert unattended shutdown software available via free download from www.tripplite.com (cabling included)
Complete surge protection, line isolation and EMI/RFI noise filtering
5 diagnostic LEDs indicate AC present, on battery, voltage correction, overload & battery low/replace
1/5
Battery replacement door and back panel grounding lug
Specifications
OUTPUT
Output Volt Amp Capacity (VA)
700
Output Watt Capacity (watts)
450
Output power factor
0.6
Nominal Output Voltage(s)
Supported
115V; 120V
Frequency compatibility
60 Hz
Output voltage regulation (line mode)
-18%, +8%
Output voltage regulation (Battery
mode)
115V (+/- 5%)
Built-in UPS output receptacles
4 5-15R outlet(s)
Output receptacle details
Hospital grade output receptacles
Output AC waveform (AC mode)
Sine wave
Output AC waveform (battery mode)
PWM sine wave
INPUT
Rated input current (at maximum
load)
5.5A
Nominal Input Voltage(s) Supported
120V AC
UPS input connection type
5-15P-HG
Input circuit breaker
10A
UPS Input cord length (ft.)
6
UPS Input cord length (m)
1.8
Recommended Electrical Service
15A 120V
Input cord length (ft.)
6
Input cord length (m)
1.8
Phase
Single-Phase
BATTERY
Full load runtime (minutes)
18 min. (450w)
Half load runtime (minutes)
42 min. (225w)
DC system voltage (VDC)
36
Battery recharge rate (included
batteries)
Less than 4 hours from 10% to 90%
2/5
Replacement battery cartridge
(internal UPS battery replacement)
RBC53
Battery Access
Battery access door
Battery replacement description
Hot-swappable, user replaceable batteries
VOLTAGE REGULATION
Voltage regulation description
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 81 to 143
Overvoltage correction
Input voltages between 126 and 143 are reduced by 9%
Undervoltage correction
Input voltages between 96 and 106 are boosted by 10%
Severe undervoltage correction
Input voltages between 81 and 95 are boosted by 21%
LEDS ALARMS & SWITCHES
LED Indicators
5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
Alarms
Audible alarm indicates power-failure, overload and low-battery conditions
Alarm cancel operation
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate
low-battery status
Switches
2 Switches control off/on power status and alarm-cancel/self-test operation
SURGE / NOISE SUPPRESSION
UPS AC suppression joule rating
480
UPS AC suppression response time
Instantaneous
EMI / RFI AC noise suppression
Yes
AC suppression joule rating
480
AC suppression response time
Instantaneous
ISOLATION
Output isolation transformer
Hospital grade load isolation transformer
Leakage current
Equal to 100 microamps
PHYSICAL
Installation form factors supported
with included accessories
Tower
Installation form factors supported
with optional accessories
Wallmount (UPSWM - tower mounting kit)
Primary form factor
Tower
UPS / Power Module dimensions in
primary form factor (height x width x
depth / inches)
12.8 x 7.5 x 9
3/5
UPS / Power Module dimensions in
primary form factor (height x width x
depth / cm)
32.4 x 19 x 22.9
UPS / Power Module weight (lbs)
44.2
UPS / Power Module weight (kg)
20.1
UPS Shipping dimensions (height x
width x depth / inches)
18.2 x 11.8 x 13.5
UPS Shipping dimensions (height x
width x depth / cm)
46.4 x 29.8 x 34.3
Shipping weight (lbs)
49
Shipping weight (kg)
22.2
Cooling method
Fan
UPS housing material
PVC
ENVIRONMENTAL
Operating Temperature Range
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity
0 to 95%, non-condensing
AC mode BTU / hr. (full load)
97.7
Battery mode BTU / hr. (full load)
189.1
AC mode efficiency rating (100%
load)
94%
COMMUNICATIONS
Communications interface
USB; DB9 Serial
Network monitoring port description
Supports detailed monitoring of UPS and site power conditions
PowerAlert software
Included
Communications cable
USB and DB9 serial cabling included
LINE / BATTERY TRANSFER
Transfer time
2-4 milliseconds
Low voltage transfer to battery
power (setpoint)
81
High voltage transfer to battery
power (setpoint)
143
SPECIAL FEATURES
Grounding lug
Grounding lug
Cold Start (startup in battery mode
during a power failure)
Cold-start operation supported
4/5
High availability UPS features
Hot swappable batteries
Green & high efficiency features
Greater than 95% efficiency - GREEN UPS
CERTIFICATIONS
UPS Certifications
Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category A (EMI); Tested to UL60601-1
(medical grade)
WARRANTY
Product Warranty Period (Worldwide)
2-year limited warranty
© 2014 Tripp Lite. All rights reserved. All trademarks are the sole property of their respective owners. Tripp Lite has a policy of continuous improvement.
Specifications are subject to change without notice. Photos may differ slightly from final products.
5/5