NO W O ST ! IN CK Tripp Lite 3-Phase PDUs ü POWER DISTRIBUTION FOR 3-PHASE APPLICATIONS ü LOCAL AND REMOTE DISPLAY OF POWER LOAD ü 3-PHASE INPUT, SINGLE-PHASE OUTPUT ALL TRIPP LITE 3-PHASE PDUs ARE COMPATIBLE WITH 3-PHASE UPS SYSTEMS FROM TRIPP LITE, APC AND OTHER MANUFACTURERS! •Support real-time monitoring of all reported functions with support for user-specified alarm and notification thresholds •Support in-rack environmental and security monitoring with optional ENVIROSENSE temperature/humidity probe and rack access notification for up to four door sensors (SRSWITCH) or other user-supplied contact-closure sensors •Lighted display with scroll-button offers IP-address self-identification, power consumption in amps and 180° rotation for overhead or raised floor power feeds •Fully compatible with PowerAlert Network Management System, available via FREE download from www.tripplite.com •PowerAlert interface supports custom notification and control of user-specified remote conditions via email, secure web, SNMP, Telnet or SSH interface 3-Phase Monitored PDUs support real-time remote monitoring of load level, voltage and frequency with options for environmental and security monitoring. 3-Phase Switched PDUs support remote individual outlet control, monitoring of output load level per outlet or per load bank, input voltage and frequency reporting with options for environmental and security monitoring. 3-PHASE PDU FEATURES BY GROUPING Monitored PDUs Switched PDUs COMPATIBLE WITH 3-PHASE UPS SYSTEMS from Tripp Lite, APC, and Other Manufacturers ü ü DISTRIBUTE POWER to multiple devices (multiple outlets) ü ü LOCALLY VIEW PDU LOAD (amps) (digital load meter) ü ü REMOTELY VIEW PDU LOAD (amps) & alarm conditions (network interface/software) ü ü REMOTELY CONTROL individual outlets (network interface/software/switchable outlets) ü MONITOR CURRENT of individual outlets, in amps, per phase ü See Reverse for Individual Product Specifications. Tripp Lite has a complete line of 3-Phase UPS Systems, 20kVA-80kVA! For More Information, Contact: Tripp Lite Pre-Sales Hotline 773.869.1236 [email protected] Tripp Lite has been a trusted manufacturer of innovative solutions for over 85 years! Tripp Lite 3-Phase PDUs 3-Phase Monitored PDU Systems Model Input Voltage / Phase Output Voltage / Phase Capacity Output Breakers Input Plug Type Cord Length Outlets PDU3VN10L2120LV 208V / 3-phase 120V / single-phase 5.7kVA / 16A per bank n/a NEMA L21-20P 10 ft. (36) 5-15/20R PDU3VN3L2120LV 208V / 3-phase 120V / single-phase 5.7kVA / 16A per bank n/a NEMA L21-20P 3 ft. (36) 5-15/20R PDU3VN10L1520 208V / 3-phase 208V / single-phase 5.7kVA / 9.2A per bank n/a NEMA L15-20P 10 ft. (30) C13, (6) C19 PDU3VN3L1520 208V / 3-phase 208V / single-phase 5.7kVA / 9.2A per bank n/a NEMA L15-20P 3 ft. (30) C13, (6) C19 PDU3VN10L2120 208V / 3-phase 208V / single-phase 5.7kVA / 9.2A per bank n/a NEMA L21-20P 10 ft. (30) C13, (6) C19 PDU3VN3L2120 208V / 3-phase 208V / single-phase 5.7kVA / 9.2A per bank n/a NEMA L21-20P 3 ft. (30) C13, (6) C19 PDU3VN10G30 208V / 3-phase 208V / single-phase 8.6kVA / 13.9A per bank 20A (x3) IEC-309 (3P+G 30A) 10 ft. (30) C13, (6) C19 PDU3VN3G30 208V / 3-phase 208V / single-phase 8.6kVA / 13.9A per bank 20A (x3) IEC-309 (3P+G 30A) 3 ft. (30) C13, (6) C19 PDU3VN10L1530 208V / 3-phase 208V / single-phase 8.6kVA / 13.9A per bank 20A (x3) NEMA L15-30P 10 ft. (30) C13, (6) C19 PDU3VN3L1530 208V / 3-phase 208V / single-phase 8.6kVA / 13.9A per bank 20A (x3) NEMA L15-30P 3 ft. (30) C13, (6) C19 PDU3VN10L2130 208V / 3-phase 208V / single-phase 8.6kVA / 13.9A per bank 20A (x3) NEMA L21-30P 10 ft. (30) C13, (6) C19 PDU3VN3L2130 208V / 3-phase 208V / single-phase 8.6kVA / 13.9A per bank 20A (x3) NEMA L21-30P 3 ft. (30) C13, (6) C19 PDU3VN10H50 208V / 3-phase 208V / single-phase 12.6kVA / 20A per bank 20A (x3) HUBBELL CS8365C 10 ft. (30) C13, (6) C19 PDU3VN3H50 208V / 3-phase 208V / single-phase 12.6kVA / 20A per bank 20A (x3) HUBBELL CS8365C 3 ft. (30) C13, (6) C19 PDU3VN10G60 208V / 3-phase 208V / single-phase 12.6kVA / 20A per bank 20A (x3) IEC-309 Blue (3P+G 60A) 10 ft. (30) C13, (6) C19 PDU3VN3G60 208V / 3-phase 208V / single-phase 12.6kVA / 20A per bank 20A (x3) IEC-309 Blue (3P+G 60A) 3 ft. (30) C13, (6) C19 PDU3XVN10G16 400V / 3-phase 230V / single-phase 11kVA / 16A per bank n/a IEC-309 Red 16A (3P+N+E) 10 ft. (30) C13, (6) C19 PDU3XVN3G16 400V / 3-phase 230V / single-phase 11kVA / 16A per bank n/a IEC-309 Red 16A (3P+N+E) 3 ft. (30) C13, (6) C19 Output Voltage / Phase Capacity Output Breakers Input Plug Type Cord Length Outlets 3-Phase Switched PDU Systems Model Input Voltage / Phase PDU3VSR10L1520 208V / 3-phase 208V / single phase 5.7kVA / 9.2A per bank 20A (x3) NEMA L15-20P 10 ft. (21) C13, (3) C19 PDU3VSR3L1520 208V / 3-phase 208V / single-phase 5.7kVA / 9.2A per bank 20A (x3) NEMA L15-20P 3 ft. (21) C13, (3) C19 PDU3VSR10L2120 208V / 3-phase 208V / single-phase 5.7kVA / 9.2A per bank n/a NEMA L21-20P 10 ft. (21) C13, (3) C19 PDU3VSR3L2120 208V / 3-phase 208V / single-phase 5.7kVA / 9.2A per bank n/a NEMA L21-20P 3 ft. (21) C13, (3) C19 PDU3VSR10G30 208V / 3-phase 208V / single-phase 8.6kVA / 13.9A per bank 20A (x3) IEC-309 (3P+G 30A) 10 ft. (21) C13, (3) C19 PDU3VSR3G30 208V / 3-phase 208V / single-phase 8.6kVA / 13.9A per bank 20A (x3) IEC-309 (3P+G 30A) 3 ft. (21) C13, (3) C19 PDU3VSR10L1530 208V / 3-phase 208V / single-phase 8.6kVA / 13.9A per bank 20A (x3) NEMA L15-30P 10 ft. (21) C13, (3) C19 PDU3VSR3L1530 208V / 3-phase 208V / single-phase 8.6kVA / 13.9A per bank 20A (x3) NEMA L15-30P 3 ft. (21) C13, (3) C19 PDU3VSR10L2130 208V / 3-phase 208V / single-phase 8.6kVA / 13.9A per bank 20A (x3) NEMA L21-30P 10 ft. (21) C13, (3) C19 PDU3VSR3L2130 208V / 3-phase 208V / single-phase 8.6kVA / 13.9A per bank 20A (x3) NEMA L21-30P 3 ft. (21) C13, (3) C19 PDU3VSR10H50 208V / 3-phase 208V / single-phase 12.6kVA / 20A per bank 20A (x3) HUBBELL CS8365C 10 ft. (21) C13, (3) C19 PDU3VSR3H50 208V / 3-phase 208V / single-phase 12.6kVA / 20A per bank 20A (x3) HUBBELL CS8365C 3 ft. (21) C13, (3) C19 PDU3VSR10G60 208V / 3-phase 208V / single-phase 12.6kVA / 20A per bank 20A (x3) IEC-309 Blue (3P+G 60A) 10 ft. (21) C13, (3) C19 PDU3VSR3G60 208V / 3-phase 208V / single-phase 12.6kVA / 20A per bank 20A (x3) IEC-309 Blue (3P+G 60A) 3 ft. (21) C13, (3) C19 PDU3XVSR10G16 400V / 3-phase 230V / single-phase 11kVA / 16A per bank n/a IEC-309 Red 16A (3P+N+E) 10 ft. (21) C13, (3) C19 PDU3XVSR3G16 400V / 3-phase 230V / single-phase 11kVA / 16A per bank n/a IEC-309 Red 16A (3P+N+E) 3 ft. (21) C13, (3) C19 For More Information, Contact: Tripp Lite Pre-Sales Hotline 773.869.1236 [email protected] Tripp Lite has been a trusted manufacturer of innovative solutions for over 85 years! 201012005 95-3195