SMARTONLINE ™ 3-PHASE UPS SYSTEMS The Most Reliable and Cost-Effective Power Solutions for Your Data Center SUPPORT UP TO 160 KVA IN PARALLEL SMARTONLINE E3 (40 – 80 KVA) IDEAL OUTPUT POWER PROTECTS CRITICAL SYSTEMS MODULAR ARCHITECTURE ELIMINATES DOWNTIME 1:1 GENERATOR SIZING LOWERS INSTALLATION COSTS EXTREME EFFICIENCY LOWERS OPERATING COSTS SMARTONLINE T3 (20 – 30 KVA) RELIABLE OPERATION KEEPS EQUIPMENT POWERED COMPACT FOOTPRINT SAVES FACILITY FLOOR SPACE VERSATILE BATTERY SYSTEM EXPANDS RUNTIME OPTIONS SMARTONLINE E3 UPS SYSTEMS Extremely efficient protection for your most important equipment IDEAL OUTPUT POWER PROTECTS CRITICAL SYSTEMS On-line, double conversion operation continuously delivers precision-regulated, pure sine wave output, isolating your critical systems from damaging and disruptive power problems. MODULAR ARCHITECTURE ELIMINATES DOWNTIME Internal N+1 power module redundancy, 1+1 parallel capability and fault-tolerant bypass features keep your critical systems highly available and productive around the clock. 1:1 GENERATOR SIZING LOWERS INSTALLATION COSTS An advanced IGBT rectifier produces best-in-class 4% THDi (input current Total Harmonic Distortion), eliminating costly over-sizing requirements for generators, breakers and cables. EXTREME EFFICIENCY LOWERS OPERATING COSTS Efficiency up to 96% significantly lowers power and cooling costs compared to multiple smaller units or legacy high-capacity units. SmartOnline E3 UPS Systems contain up to four intelligent, independent 20 kVA power modules that support internal N+1 redundancy. If any power module goes offline, the load is distributed among the remaining modules and your equipment continues to operate without interruption. The UPS systems also support a 1+1 parallel configuration to increase fault tolerance or double output capacity (up to 160 kVA). C O SMARTONLINE E3 UPS SYSTEMS SU80K 120/208 VAC 80 kVA / 64 kW SU80KTV 277/480 VAC 80 kVA / 64 kW SU60K 120/208 VAC 60 kVA / 48 kW SU60KTV 277/480 VAC 60 kVA / 48 kW SU40K 120/208 VAC 40 kVA / 32 kW 2 N T E N T S IDEAL OUTPUT POWER 4 MODULAR ARCHITECTURE 4 PARALLEL FEATURES 4 1:1 GENERATOR SIZING 5 EXTREME EFFICIENCY 5 GREEN POWER 5 MONITORING AND CONTROL 6 BATTERY CABINETS 6 COMPACT FOOTPRINT 7 ORDERING INFORMATION 7 TECHNICAL SPECIFICATIONS 8 WARRANTIES AND SERVICES 12 SMARTONLINE T3 UPS SYSTEMS Reliable protection for small and mid-range installations RELIABLE OPERATION KEEPS EQUIPMENT POWERED On-line operation and fault-tolerant bypass features keep your equipment powered at all times—even if the UPS system requires maintenance, repair or replacement. COMPACT FOOTPRINT SAVES FACILITY FLOOR SPACE The all-in-one design packs enough power for multiple racks of equipment into a compact footprint that saves precious floor space for critical systems and cooling. VERSATILE BATTERY SYSTEM EXPANDS RUNTIME OPTIONS A hot-swappable battery system with convenient front-panel access allows you to customize battery backup runtime through internal and/or external expansion. SmartOnline T3 UPS Systems are available in standard and extended-runtime configurations. The power module and expandable internal battery system are combined in a single compact footprint. Runtime can also be increased by connecting one or more external battery cabinets. C O T E N T S SMARTONLINE T3 UPS SYSTEMS RELIABLE OPERATION 9 COMPACT FOOTPRINT 9 SU30K3/3 120/208 VAC 30 kVA / 24 kW VERSATILE BATTERY SYSTEM SU30K3/3XR5 120/208 VAC 30 kVA / 24 kW SU20K3/3 120/208 VAC 20 kVA / 16 kW SU20K3/3XR5 120/208 VAC 20 kVA / 16 kW 3 N 9 MONITORING AND CONTROL 10 ORDERING INFORMATION 10 TECHNICAL SPECIFICATIONS 11 WARRANTIES AND SERVICES 12 SMARTONLINE E3 UPS SYSTEMS IDEAL OUTPUT POWER INTERNAL N+1 REDUNDANCY SmartOnline E3 UPS Systems isolate your critical equipment from power problems, including surges, line distortion, electrical variations, brownouts, noise, harmonic impulses, frequency overvoltages 20 kVA 20 kVA Redundancy Power Module 20 kVA Power Module and 1+1 PARALLEL REDUNDANCY 20 kVA blackouts. True on-line operation continually Power Module 50% Support 20 kVA transforms AC input power into filtered DC Power Module 60 kVA 50% SupportLoad power, then resynthesizes it into precisionregulated AC output with a pure sine wave. 80 kVA Strong overload capacity supports up to 150% Load output for up to 60 seconds. Reliable backup power with zero transfer time to battery keeps equipment operating safely through shorter power failures and allows time to shut down or switch to generator power during longer outages. Rapid recharging restores battery charge levels in as little as two hours. External 80 kVA External Battery Cabinet Battery Cabinet UPS System MODULAR ARCHITECTURE Intelligent, independent 20 kVA power External 80 kVA 80 kVA UPS SystemUPS System Battery Cabinet In an N+1 configuration, the supported load is at least 20 kVA less than the maximum output capacity of the UPS system. For example, an 80 kVA UPS is configured for N+1 redundancy when the connected load is 60 kVA or less. modules provide internal redundancy. When 1+1 PARALLEL REDUNDANCY the UPS is configured for N+1 redundancy, convenient hot-swap power modules can 50% Support be replaced without powering down the 50% Support connected load. In the event of a power module fault, the load is automatically 80 kVA distributed among the remaining modules. Load Because load redistribution happens without interrupting critical systems, mean time to recovery is zero—far superior to legacy UPS systems. In addition, redundant control circuits eliminate a single point of failure commonly found in less reliable UPS designs. If service or repair requires UPS shutdown, a manual bypass breaker and automatic External Battery Cabinet 80 kVA UPS System External Battery Cabinet 80 kVA UPS System Two 80 kVA SmartOnline E3 UPS Systems can provide redundant backup power for an 80 kVA load. bypass function maintain system availability by passing through AC power until the UPS 1+1 PARALLEL CAPACITY DOUBLING system returns to service. 100% Support 100% Support PARALLEL FEATURES Increase fault tolerance or double output 160 kVA capacity by connecting two SmartOnline E3 Load UPS Systems in a 1+1 parallel configuration. If one UPS is taken offline for maintenance, the other UPS automatically compensates to support the equipment load—without requiring additional programming.* UPS systems ship ready for parallel operation and patented dual-DSP technology provides optimal synchronization of power sources. * Each UPS system must be configured to support ≤ 50% of the total load to provide redundancy in a 1+1 parallel configuration. External Battery Cabinet 80 kVA UPS System External Battery Cabinet 80 kVA UPS System Two 80 kVA SmartOnline E3 UPS Systems can provide non-redundant backup power for a 160 kVA load. 4 1:1 GENERATOR SIZING EXTREME EFFICIENCY SmartOnline E3 UPS Systems have a Advanced high-utilization IGBT inverter technology and high-speed DSP control provide generator-friendly design that decreases superior operating efficiency at all load levels (up to 96% in economy mode). Increasing installation costs. A high input power efficiency lowers UPS system operating costs by reducing electricity consumption, heat factor and IGBT rectifier with DSP control emissions and cooling costs. Replacing 160 kVA of legacy UPS capacity with SmartOnline create less than 4% input current Total E3 UPS Systems can save more than $20,000 per year. Harmonic Distortion (THDi). Low THDi enables cost-saving 1:1 sizing of UPS systems to generators, allows generators to run cooler and extends the operational lifespan of all input components. Low THDi In addition, SmartOnline E3 UPS Systems automatically correct the widest range of incoming voltages in their class. The wide voltage window and temperature-compensated charging combine to significantly decrease battery wear, extending service life and reducing replacement costs. also reduces sizing requirements for cables and breakers and improves reliability by eliminating nuisance breaker tripping and overheated transformers. EFFICIENCY CHART 100% INSTALLATION COST COMPARISON SmartOnline E3’s Extreme Efficiency Advantage Cabling Breakers Related Costs EFFICIENCY SmartOnline E3 SmartOnline E3 Generators 85% Legacy UPS Legacy UPS 70% 50% 75% 100% LOAD Cost SmartOnline E3 UPS Systems reduce installation costs up to 30% versus legacy UPS systems. SmartOnline E3’s extreme efficiency can reduce your data center’s operating costs significantly. Replacing 160 kVA of legacy capacity can reduce power costs more than $20,000 per year. GREEN POWER CUMULATIVE ENVIRONMENTAL IMPACT OVER FIVE YEARS Eco-friendly SmartOnline E3 Legacy UPS Energy Usage (MWh) 1956 UPS Systems save energy 1 and reduce your carbon 1752 SmartOnline E3 Energy Usage (MWh) 1310 1174 Legacy UPS CO2 Emissions (Tons) footprint. Replacing 160 kVA SmartOnline E3 CO2 Emissions (Tons) of legacy UPS capacity can 3911 reduce CO2 emissions by 136 tons and 3504 2 2621 save more than 200 megawatt-hours of 2348 electricity per year—enough to power 16 typical U.S. single-family homes. 5867 5256 3 3931 SmartOnline E3 UPS Systems 3522 are also RoHS compliant, which means they adhere to strict standards in the 7823 7008 4 5241 reduction of six hazardous substances: hexavalent biphenyls lead, mercury, chromium, (PBB) and 4695 cadmium, 9779 polybrominated polybrominated 8760 5 6552 5869 diphenyl ether (PBDE). Tripp Lite is an industry leader in RoHS compliance. Replacing 160 kVA of legacy UPS capacity with SmartOnline E3 can save 200 megawatt-hours (enough to power 16 U.S. homes) and reduce CO2 emissions by 136 tons (enough to offset 2,000+ flights from New York to Washington) per year. 5 MONITORING AND CONTROL POWERALERT NETWORK MANAGEMENT SYSTEM Convenient communication and management features allow you to monitor power conditions, receive automatic alerts and control SmartOnline E3 UPS Systems with drift-proof digital precision from any distance. • DRY CONTACT CLOSURE INTERFACE Connects to an Emergency Power Off (EPO) circuit for emergency UPS system shutdown. Also allows the UPS system to monitor external battery cabinets and communicate PowerAlert allows you to manage up to 250 UPS systems from a single workstation. Real-Time Power Status Consoles operational messages. SmartOnline E3 UPS Systems support remote management through PowerAlert software or the SNMPWEBCARD accessory. • RS-232 SERIAL PORT Connects to a server for shutdown commands and reporting through PowerAlert software (included). • ACCESSORY CARD SLOT Optional network card (SNMPWEBCARD) provides remote monitoring and control. Optional environmental sensor (ENVIROSENSE) monitors The LED/LCD control panel provides detailed UPS status information. temperature, humidity and more. • NETWORK POWER MANAGEMENT Dry Contact Closure Interface Through PowerAlert software or SNMPWEBCARD, you can manage up to 250 UPS systems with PowerAlert Network Accessory Card Slot Management System (included) or a third-party network management system. • LED/LCD CONTROL PANEL Offers convenient push button control and communicates operational modes, 1+1 Parallel Interface RS-232 Serial Port The rear panel includes several communication interfaces. conditions and warnings. BATTERY CABINETS All SmartOnline E3 UPS Systems can be connected to one or more external battery cabinets: • Model SU40K has internal batteries and does not require an external battery cabinet. External battery cabinets can be connected for expanded runtime. • Other models do not have internal batteries and require an external battery cabinet. Additional battery cabinets can be connected for expanded runtime. External battery cabinets are available in a variety of capacities. Models BP480V26B and BP480V40C support temperature-compensated charging for optimal charge levels and increased battery lifespan. They also match the appearance and footprint of the UPS system cabinets. Larger models have heavy-gauge steel cabinets with 10-year design life batteries. BP480V26B 6 BP480V40C COMPACT FOOTPRINT Each SmartOnline E3 UPS System packs enough power for multiple racks of equipment into a compact footprint, saving valuable data center floor space for critical systems and cooling. Wall-mounted distribution and bypass panels do not require additional floor space. ORDERING INFORMATION MODEL OUTPUT CAPACITY NOMINAL INPUT/OUTPUT VOLTAGE BATTERY CONFIGURATION SU40K 40 kVA / 32 kW 120/208 VAC (3Ø, 4-wire + ground, wye) Internal batteries; external battery cabinet optional. SU60K 60 kVA / 48 kW 120/208 VAC (3Ø, 4-wire + ground, wye) No internal batteries; external battery cabinet required. SU80K 80 kVA / 64 kW 120/208 VAC (3Ø, 4-wire + ground, wye) No internal batteries; external battery cabinet required. SU60KTV 60 kVA / 48 kW 277/480 VAC (3Ø, 4-wire + ground, wye) No internal batteries; external battery cabinet required. SU80KTV 80 kVA / 64 kW 277/480 VAC (3Ø, 4-wire + ground, wye) No internal batteries; external battery cabinet required. EXTERNAL BATTERY CABINETS (Hardwire connection. Multiple cabinets can be daisy-chained.) BP480V26B +/- 240 VDC external battery cabinet. Supports temperature-compensated battery charging for optimal charge levels and increased battery lifespan. Cabinet matches appearance and footprint of UPS system cabinet. BP480V40C +/- 240 VDC external battery cabinet. Supports temperature-compensated battery charging for optimal charge levels and increased battery lifespan. Cabinet matches appearance and footprint of UPS system cabinet. BP480V55 +/- 240 VDC external battery cabinet. Heavy-gauge steel cabinet with 10-year design life batteries. BP480V78 +/- 240 VDC external battery cabinet. Heavy-gauge steel cabinet with 10-year design life batteries. BP480V103 +/- 240 VDC external battery cabinet. Heavy-gauge steel cabinet with 10-year design life batteries. BP480V140 +/- 240 VDC external battery cabinet. Heavy-gauge steel cabinet with 10-year design life batteries. WALL-MOUNTED EXTERNAL MAINTENANCE BYPASS PANELS WITH KEYED SAFETY INTERLOCK SYSTEM SU40KMBPK Maintenance bypass panel for SU40K only. Keyed safety interlock system prevents sequence of operation errors. SU60KMBPK Maintenance bypass panel for SU60K only. Keyed safety interlock system prevents sequence of operation errors. SU80KMBPK Maintenance bypass panel for SU80K only. Keyed safety interlock system prevents sequence of operation errors. SU60KMBPKX Maintenance bypass panel for SU60KTV only. Keyed safety interlock system prevents sequence of operation errors. SU80KMBPKX Maintenance bypass panel for SU80KTV only. Keyed safety interlock system prevents sequence of operation errors. WALL-MOUNTED PARALLEL DISTRIBUTION PANELS (Required for 1+1 parallel connection of UPS systems.) SUPC2MBP40K Parallel distribution panel for 1+1 parallel connection of SU40K models only. SUPC2MBP60K Parallel distribution panel for 1+1 parallel connection of SU60K models only. SUPC2MBP80K Parallel distribution panel for 1+1 parallel connection of SU80K models only. SUPC2MBP60KTV Parallel distribution panel for 1+1 parallel connection of SU60KTV models only. SUPC2MBP80KTV Parallel distribution panel for 1+1 parallel connection of SU80KTV models only. POWER MANAGEMENT ACCESSORIES SNMPWEBCARD Adds Ethernet network interface to UPS system for remote monitoring and control via SNMP, Web or telnet. ENVIROSENSE Monitors temperature and humidity. Monitors up to 3 additional sensors via dry contact closure interface. Requires SNMPWEBCARD. WARRANTIES AND SERVICES Site survey services, start-up services, preventive maintenance services, extended warranties and on-site warranties are available. Visit www.tripplite.com or contact your Tripp Lite sales representative for more information. 7 TECHNICAL SPECIFICATIONS MODEL SU40K SU60K 277/480 VAC (3Ø, 4-wire + ground, wye) 94~150 / 163~260 VAC (Full Load) 65~150 / 113~260 VAC (≤ 70% Load) 218~348 / 378~603 VAC (Full Load) 151~348 / 262~603 VAC (≤ 70% Load) INPUT < 4% POWER FACTOR (On-line, Full Load) > 0.99 FREQUENCY (Auto-Selectable) 50/60 Hz FREQUENCY TOLERANCE ± 5% 97 A 145 A 193 A 63 A 84 A CAPACITY (VA) 40,000 VA 60,000 VA 80,000 VA 60,000 VA 80,000 VA CAPACITY (Watts) 32,000 W 48,000 W 64,000 W 48,000 W 64,000 W POWER FACTOR 0.8 Per Phase OUTPUT NOMINAL VOLTAGE 120/208 VAC 277/480 VAC FREQUENCY 50/60 Hz ± 0.05 Hz NOMINAL CURRENT 111 A 167 A 222 A WAVEFORM (On-line or Battery) THD (Linear Load) ≤ 3% VOLTAGE REGULATION (Static) ± 1% BREAKERS RECTIFIER (3-Pole, 600 VAC) 75 A 125 A 150 A 125 A 150 A BYPASS (3-Pole, 600 VAC) 150 A 225 A 300 A 100 A 125 A RESERVE (3-Pole, 600 VAC) 150 A 225 A 300 A 100 A 125 A OUTPUT (3-Pole, 600 VAC) 150 A 225 A 300 A 100 A 125 A BATTERY (Negative Pole, 600 VDC) 100 A 150 A 150 A 100 A 150 A STANDARD INTERFACE LED/LCD Control Panel with Event Log, RS-232, Dry Contact Closure, EPO (Local and Remote) OPTIONAL INTERFACE SNMPWEBCARD, ENVIROSENSE On-line, Double Conversion AGENCY APPROVALS UL 1778, cUL, FCC Class A, RoHS EFFICIENCY Up to 96% TRANSFER TIME (On-line Mode) 0 ms AMBIENT OPERATING TEMPERATURE GENERAL 96 A ≤ 125% for 10 minutes; ≤ 150% for 60 seconds; > 150% for 1 second UPS TOPOLOGY 32° F to 104° F (0° C to 40° C) ELEVATION 0 to 10,000 ft (0 to 3,000 m) ≤ 90% HUMIDITY (Non-Condensing) NOISE (1 m) < 65 dBA 13/5.5+ min 25/8+ min 20/6+ min 25/8+ min 25/6+ min (Internal Batteries) (BP480V40C) (BP480V40C) (BP480V40C) (BP480V40C) Height 66.9 in (1,699 mm) 66.9 in (1,699 mm) 66.9 in (1,699 mm) 66.9 in (1,699 mm) 66.9 in (1,699 mm) Width 20.5 in (521 mm) 20.5 in (521 mm) 20.5 in (521 mm) 20.5 in (521 mm) 20.5 in (521 mm) Depth 33.7 in (856 mm) 37.7 in (958 mm) 38.8 in (986 mm) 33.7 in (856 mm) 33.7 in (856 mm) 1,513 lb (688 kg) 1,178 lb (535 kg) 1,444 lb (656 kg) 995 lb (452 kg) 1,105 lb (502 kg) 1,690 lb (768 kg) 1,356 lb (616 kg) 1,643 lb (747 kg) 1,175 lb (534 kg) 1,286 lb (585 kg) TYPICAL RUNTIME* (Half/Full Load) DIMENSIONS (Power Module) UNIT WEIGHT ** (Power Module) SHIPPING WEIGHT** (Power Module) ** 72 A Pure Sine Wave OVERLOAD CAPACITY * SU80KTV 120/208 VAC THDi (Full Load) CURRENT NOMINAL CURRENT SU60KTV (3Ø, 4-wire + ground, wye) NOMINAL VOLTAGE VOLTAGE RANGE SU80K Runtime varies with load, battery condition and other factors. Runtime can be extended by adding additional external battery cabinets, sold separately. The weight of model SU40K includes internal batteries. 8 SMARTONLINE T3 UPS SYSTEMS RELIABLE OPERATION VERSATILE BATTERY SYSTEM SmartOnline T3 UPS Systems protect your equipment from power All SmartOnline T3 UPS Systems scale to fit your runtime problems, including surges, line noise, harmonic distortion, requirements through an expandable, hot-swappable battery electrical impulses, frequency variations, brownouts, overvoltages system with convenient front-panel access: and blackouts. On-line operation continually transforms AC • Model SU20K3/3 includes 2 internal battery packs and has input power into filtered DC power, then resynthesizes it into room to add 2 additional battery packs.* precision-regulated AC output with a pure sine wave. Reliable • Model SU30K3/3 includes 3 internal battery packs and has backup power with zero transfer time to battery keeps equipment room to add 1 additional battery pack.* operating safely through shorter power failures and allows time to shut down or switch to generator power during longer outages. • Extended-runtime models (SU20K3/3XR5 and SU30K3/3XR5) Fault-tolerant bypass features keep your equipment powered at each include 5 internal battery packs and have room to add all times—even if the UPS system requires maintenance, repair 3 additional battery packs.* or replacement. • All models can also be connected to one or more compact external battery cabinets (SUBF2030). Each external battery COMPACT FOOTPRINT cabinet holds up to 4 battery packs, sold separately.* SmartOnline T3 UPS Systems have an all-in-one form factor that • Larger-capacity external battery cabinets with 10-year design combines the power module and battery system. They pack life batteries are also available. enough power for multiple racks of equipment into a compact * Battery pack model SURBC2030. footprint that saves valuable data center floor space for critical systems and cooling. Wall-mounted distribution and bypass panels do not require additional floor space. + _ + _ + _ OPEN + _ + _ SU20K3/3 SU30K3/3 OPEN OPEN OPEN OPEN + _ OPEN + _ + _ + _ + _ SU20K3/3XR5 OPEN OPEN + _ OPEN + _ + _ + _ + _ SU30K3/3XR5 OPEN OPEN OPEN OPEN SUBF2030 External Battery Cabinet SURBC2030 Internal Battery Pack SmartOnline T3 UPS Systems combine the power module and battery system in a single compact footprint. You can increase battery backup runtime by installing additional internal battery packs and/or external battery cabinets. External battery cabinets support daisy-chaining. 9 MONITORING AND CONTROL POWERALERT NETWORK MANAGEMENT SYSTEM Convenient communication and management features allow you to monitor power conditions, receive automatic alerts and control SmartOnline T3 UPS Systems from any distance. • COMMUNICATION PORTS RS-232, AS/400 and dry contact closure ports connect to servers for shutdown commands and reporting through PowerAlert software (included). An Emergency Power Off (EPO) jack connects to your facility’s EPO circuit for emergency UPS system shutdown. • ACCESSORY CARD SLOT PowerAlert allows you to manage up to 250 UPS systems from a single workstation. Optional network card (SNMPWEBCARD) provides remote monitoring and control. Optional dry contact closure accessory card (RELAYIOCARD) provides 6 outputs and Real-Time Power Status Consoles SmartOnline T3 UPS Systems support remote management through PowerAlert software or the SNMPWEBCARD accessory. 1 input. • NETWORK POWER MANAGEMENT Through PowerAlert software or SNMPWEBCARD, you can manage up to 250 UPS systems with PowerAlert Network Management System (included) or a third-party network management system. • LED/LCD CONTROL PANEL Offers convenient push button control and communicates The LCD/LED control panel indicates more than 45 separate faults, warnings and operational conditions. operational modes, conditions and warnings. ORDERING INFORMATION MODEL OUTPUT CAPACITY BATTERY CONFIGURATION SU20K3/3 20 kVA / 16 kW Includes 2 internal battery packs; room for 2 additional SURBC2030 battery packs. SU20K3/3XR5 20 kVA / 16 kW Includes 5 internal battery packs; room for 3 additional SURBC2030 battery packs. SU30K3/3 30 kVA / 24 kW Includes 3 internal battery packs; room for 1 additional SURBC2030 battery pack. SU30K3/3XR5 30 kVA / 24 kW Includes 5 internal battery packs; room for 3 additional SURBC2030 battery packs. BATTERY EXPANSION (Multiple battery cabinets can be daisy-chained.) SURBC2030 240 VDC internal battery pack for SmartOnline T3 UPS Systems and SUBF2030 external battery cabinets. SUBF2030 External battery cabinet. Requires SURBC2030 battery packs (up to 4 per cabinet), sold separately. BP240V99 240 VDC external battery cabinet with 10-year design life batteries. BP240V120 240 VDC external battery cabinet with 10-year design life batteries. BP240V1207C 240 VDC external battery cabinet with 10-year design life batteries. Built-in battery charger. BP240V150 240 VDC external battery cabinet with 10-year design life batteries. BP240V1507C 240 VDC external battery cabinet with 10-year design life batteries. Built-in battery charger. WALL-MOUNTED EXTERNAL MAINTENANCE BYPASS PANELS WITH KEYED SAFETY INTERLOCK SYSTEM SU20KMBPK Maintenance bypass panel for 20 kVA models. Keyed safety interlock system prevents sequence of operation errors. SU30KMBPK Maintenance bypass panel for 30 kVA models. Keyed safety interlock system prevents sequence of operation errors. POWER MANAGEMENT ACCESSORIES SNMPWEBCARD Adds Ethernet network interface to UPS system for remote monitoring and control via SNMP, Web or telnet. ENVIROSENSE Monitors temperature and humidity. Monitors up to 3 additional sensors via dry contact closure interface. Requires SNMPWEBCARD. RELAYIOCARD Programmable dry contact closure accessory card with 6 output contacts and 1 input contact. WARRANTIES AND SERVICES Site survey services, start-up services, preventive maintenance services, extended warranties and on-site warranties are available. Visit www.tripplite.com or contact your Tripp Lite sales representative for more information. 10 TECHNICAL SPECIFICATIONS MODEL SU20K3/3 SU20K3/3XR5 INPUT NOMINAL VOLTAGE VOLTAGE RANGE 96~144 / 166~250 VAC FREQUENCY (Auto-Selectable) 50/60 Hz ± 3 Hz > 0.95 NOMINAL CURRENT OUTPUT SU30K3/3XR5 120/208 VAC (3Ø, 4-wire + ground, wye) POWER FACTOR (On-line, Full Load) 53 A 79 A CAPACITY (VA) 20,000 VA 30,000 VA CAPACITY (Watts) 16,000 W 24,000 W POWER FACTOR 0.8 Per Phase NOMINAL VOLTAGE 120/208 VAC FREQUENCY 50/60 Hz ± 0.1 Hz NOMINAL CURRENT 56 A 83 A WAVEFORM (On-line or Battery) Pure Sine Wave THD (Linear Load) ≤ 3% VOLTAGE REGULATION (Static) ± 2% OVERLOAD CAPACITY ≤ 125% for 60 seconds; ≤ 150% for 30 seconds; > 150% for 2 seconds MAIN INPUT PROTECTION 200 A / 150 VAC Fuse x 3 STANDARD INTERFACE LED/LCD Control Panel, RS-232, AS/400, Dry Contact Closure, EPO (Local and Remote) OPTIONAL INTERFACE SNMPWEBCARD, ENVIROSENSE, RELAYIOCARD UPS TOPOLOGY On-line, Double Conversion AGENCY APPROVALS UL 1778, cUL, FCC Class A, NOM EFFICIENCY TYPICAL RUNTIME* (Half/Full Load) INCLUDED INTERNAL BATTERY PACKS GENERAL SU30K3/3 INTERNAL BATTERY PACK CAPACITY** Up to 93% 13/5+ min 42/17+ min 13/5+ min 25/11+ min (Internal Batteries) (Internal Batteries) (Internal Batteries) (Internal Batteries) 2 5 3 5 4 8 4 8 (Can Add 2) (Can Add 3) (Can Add 1) (Can Add 3) TRANSFER TIME 0 ms AMBIENT OPERATING TEMPERATURE 32° F to 104° F (0° C to 40° C) ELEVATION 0 to 10,000 ft (0 to 3,000 m) ≤ 95% HUMIDITY (Non-Condensing) NOISE (1 m) < 65 dBA UNIT HEIGHT 35.9 in (912 mm) 50.9 in (1,293 mm) 35.9 in (912 mm) 50.9 in (1,293 mm) UNIT WIDTH 25.4 in (645 mm) 25.4 in (645 mm) 25.4 in (645 mm) 25.4 in (645 mm) UNIT DEPTH 36.8 in (935 mm) 36.8 in (935 mm) 36.8 in (935 mm) 36.8 in (935 mm) UNIT WEIGHT (Standard Configuration) 519 lb (236 kg) 979 lb (444 kg) 660 lb (299 kg) 999 lb (453 kg) SHIPPING WEIGHT (Standard Configuration) 607 lb (275 kg) 1,133 lb (514 kg) 748 lb (339 kg) 1,153 lb (523 kg) * Runtime shown for standard internal battery configuration. Runtime varies with load, battery condition and other factors. Runtime can be extended by adding internal battery packs and/or external battery cabinets, sold separately. ** Add internal battery pack model SURBC2030, sold separately. 11 WARRANTIES AND SERVICES ABOUT TRIPP LITE Since 1922, Tripp Lite has established a global reputation for quality by providing customers with reliable, cost-effective products and responsive service. After introducing the first desktop UPS system and the popular Isobar® surge suppressor in the early eighties, Tripp Lite became the gold standard for power protection in the growing information technology sector. More than 6 million UPS systems and 16 million Isobars later, loyal customers in over 60 countries choose Tripp Lite to power, protect and connect equipment ranging from home electronics to servers and network equipment in enterprise data centers. SmartOnline 3-Phase UPS Systems include a 1-year limited Tripp Lite manufactures more than 1,000 products, including UPS warranty backed by Tripp Lite’s experienced service and systems, replacement batteries, PDUs, power management tools, support team. Tripp Lite also offers a variety of on-site rack systems, surge suppressors, KVM switches, cables, power warranties, extended warranties, start-up services and strips, inverters, inverter/chargers, line conditioners and specialty service contracts for UPS systems and battery cabinets. products for healthcare and audio/video applications. Tripp Lite’s Tripp Lite’s expert service technicians can assist in every heritage of invention is reflected today in practical innovations phase of your implementation, from site planning and that address customer needs without ignoring fiscal realities: start-up to preventive maintenance and rapid repair. Contact Tripp Lite for more information. • SmartOnline™ Hot-Swappable UPS Systems keep critical servers, storage and network equipment running 24x7, even during UPS maintenance, repair or replacement. • SmartPro® CRM UPS Systems deliver best-in-class wattage and battery capacity in shallow-depth cabinets optimized for network/telecom wiring closets. • Green power solutions save money and protect the environment. Economy mode operation and high-efficiency UPS designs conserve energy while cutting electricity bills and carbon emissions. Eco-friendly manufacturing across every product line enables industry-leading RoHS (Restriction of Hazardous Substances) compliance for a cleaner, greener planet. Distributed By: TRIPP LITE WORLD HEADQUARTERS 1111 W. 35th Street, Chicago, IL 60609 USA 773.869.1234 • www.tripplite.com Copyright © 2009 Tripp Lite. All trademarks are the sole property of their respective owners. Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice. Photos may differ slightly from final products. 201010076 95-2916