Tripp Lite 3 Phase UPS Systems Brochure 201010076 952916

SMARTONLINE
™
3-PHASE UPS SYSTEMS
The Most Reliable and Cost-Effective Power Solutions for Your Data Center
SUPPORT
UP TO
160 KVA IN
PARALLEL
SMARTONLINE E3 (40 – 80 KVA)
IDEAL OUTPUT POWER
PROTECTS CRITICAL SYSTEMS
MODULAR ARCHITECTURE
ELIMINATES DOWNTIME
1:1 GENERATOR SIZING
LOWERS INSTALLATION COSTS
EXTREME EFFICIENCY
LOWERS OPERATING COSTS
SMARTONLINE T3 (20 – 30 KVA)
RELIABLE OPERATION
KEEPS EQUIPMENT POWERED
COMPACT FOOTPRINT
SAVES FACILITY FLOOR SPACE
VERSATILE BATTERY SYSTEM
EXPANDS RUNTIME OPTIONS
SMARTONLINE E3 UPS SYSTEMS
Extremely efficient protection for your most important equipment
IDEAL OUTPUT POWER
PROTECTS CRITICAL SYSTEMS
On-line, double conversion operation continuously
delivers precision-regulated, pure sine wave output,
isolating your critical systems from damaging and
disruptive power problems.
MODULAR ARCHITECTURE
ELIMINATES DOWNTIME
Internal N+1 power module redundancy, 1+1 parallel
capability and fault-tolerant bypass features keep your
critical systems highly available and productive around
the clock.
1:1 GENERATOR SIZING
LOWERS INSTALLATION COSTS
An advanced IGBT rectifier produces best-in-class
4% THDi (input current Total Harmonic Distortion),
eliminating costly over-sizing requirements for
generators, breakers and cables.
EXTREME EFFICIENCY
LOWERS OPERATING COSTS
Efficiency up to 96% significantly lowers power and
cooling costs compared to multiple smaller units
or legacy high-capacity units.
SmartOnline E3 UPS Systems contain up to four intelligent, independent 20 kVA
power modules that support internal N+1 redundancy. If any power module goes
offline, the load is distributed among the remaining modules and your equipment
continues to operate without interruption. The UPS systems also support a 1+1
parallel configuration to increase fault tolerance or double output capacity
(up to 160 kVA).
C
O
SMARTONLINE E3
UPS SYSTEMS
SU80K
120/208 VAC
80 kVA / 64 kW
SU80KTV
277/480 VAC
80 kVA / 64 kW
SU60K
120/208 VAC
60 kVA / 48 kW
SU60KTV
277/480 VAC
60 kVA / 48 kW
SU40K
120/208 VAC
40 kVA / 32 kW
2
N
T
E
N
T
S
IDEAL OUTPUT POWER
4
MODULAR ARCHITECTURE
4
PARALLEL FEATURES
4
1:1 GENERATOR SIZING
5
EXTREME EFFICIENCY
5
GREEN POWER
5
MONITORING AND CONTROL
6
BATTERY CABINETS
6
COMPACT FOOTPRINT
7
ORDERING INFORMATION
7
TECHNICAL SPECIFICATIONS
8
WARRANTIES AND SERVICES
12
SMARTONLINE T3 UPS SYSTEMS
Reliable protection for small and mid-range installations
RELIABLE OPERATION
KEEPS EQUIPMENT POWERED
On-line operation and fault-tolerant bypass
features keep your equipment powered at all
times—even if the UPS system requires
maintenance, repair or replacement.
COMPACT FOOTPRINT
SAVES FACILITY FLOOR SPACE
The all-in-one design packs enough power for
multiple racks of equipment into a compact
footprint that saves precious floor space for
critical systems and cooling.
VERSATILE BATTERY SYSTEM
EXPANDS RUNTIME OPTIONS
A hot-swappable battery system with convenient
front-panel access allows you to customize battery
backup runtime through internal and/or external
expansion.
SmartOnline T3 UPS Systems are available in standard and
extended-runtime configurations. The power module and expandable
internal battery system are combined in a single compact footprint.
Runtime can also be increased by connecting one or more external
battery cabinets.
C
O
T
E
N
T
S
SMARTONLINE T3
UPS SYSTEMS
RELIABLE OPERATION
9
COMPACT FOOTPRINT
9
SU30K3/3
120/208 VAC
30 kVA / 24 kW
VERSATILE BATTERY SYSTEM
SU30K3/3XR5
120/208 VAC
30 kVA / 24 kW
SU20K3/3
120/208 VAC
20 kVA / 16 kW
SU20K3/3XR5
120/208 VAC
20 kVA / 16 kW
3
N
9
MONITORING AND CONTROL
10
ORDERING INFORMATION
10
TECHNICAL SPECIFICATIONS
11
WARRANTIES AND SERVICES
12
SMARTONLINE E3 UPS SYSTEMS
IDEAL OUTPUT POWER
INTERNAL N+1 REDUNDANCY
SmartOnline E3 UPS Systems isolate your
critical equipment from power problems,
including
surges,
line
distortion,
electrical
variations,
brownouts,
noise,
harmonic
impulses,
frequency
overvoltages
20 kVA
20 kVA
Redundancy
Power Module
20 kVA
Power Module
and
1+1 PARALLEL
REDUNDANCY
20 kVA
blackouts. True on-line operation continually
Power Module
50% Support 20 kVA
transforms AC input power into filtered DC
Power Module
60 kVA
50% SupportLoad
power, then resynthesizes it into precisionregulated AC output with a pure sine wave.
80 kVA
Strong overload capacity supports up to 150%
Load
output for up to 60 seconds. Reliable backup
power with zero transfer time to battery keeps
equipment operating safely through shorter
power failures and allows time to shut down
or switch to generator power during longer
outages. Rapid recharging restores battery
charge levels in as little as two hours.
External
80 kVA
External
Battery Cabinet
Battery
Cabinet
UPS System
MODULAR ARCHITECTURE
Intelligent,
independent
20
kVA
power
External
80 kVA
80 kVA
UPS SystemUPS System
Battery
Cabinet
In an N+1 configuration, the supported load is at least 20 kVA less than the maximum output capacity of the UPS system.
For example, an 80 kVA UPS is configured for N+1 redundancy when the connected load is 60 kVA or less.
modules provide internal redundancy. When
1+1 PARALLEL REDUNDANCY
the UPS is configured for N+1 redundancy,
convenient hot-swap power modules can
50% Support
be replaced without powering down the
50% Support
connected load. In the event of a power
module fault, the load is automatically
80 kVA
distributed among the remaining modules.
Load
Because load redistribution happens without
interrupting critical systems, mean time to
recovery is zero—far superior to legacy UPS
systems. In addition, redundant control circuits
eliminate a single point of failure commonly
found in less reliable UPS designs.
If service or repair requires UPS shutdown,
a manual bypass breaker and automatic
External
Battery Cabinet
80 kVA
UPS System
External
Battery Cabinet
80 kVA
UPS System
Two 80 kVA SmartOnline E3 UPS Systems can provide redundant backup power for an 80 kVA load.
bypass function maintain system availability
by passing through AC power until the UPS
1+1 PARALLEL CAPACITY DOUBLING
system returns to service.
100% Support
100% Support
PARALLEL FEATURES
Increase fault tolerance or double output
160 kVA
capacity by connecting two SmartOnline E3
Load
UPS Systems in a 1+1 parallel configuration.
If one UPS is taken offline for maintenance,
the other UPS automatically compensates
to support the equipment load—without
requiring additional programming.*
UPS systems ship ready for parallel operation
and patented dual-DSP technology provides
optimal synchronization of power sources.
* Each UPS system must be configured to support ≤ 50% of the
total load to provide redundancy in a 1+1 parallel configuration.
External
Battery Cabinet
80 kVA
UPS System
External
Battery Cabinet
80 kVA
UPS System
Two 80 kVA SmartOnline E3 UPS Systems can provide non-redundant backup power for a 160 kVA load.
4
1:1 GENERATOR SIZING
EXTREME EFFICIENCY
SmartOnline E3 UPS Systems have a
Advanced high-utilization IGBT inverter technology and high-speed DSP control provide
generator-friendly design that decreases
superior operating efficiency at all load levels (up to 96% in economy mode). Increasing
installation costs. A high input power
efficiency lowers UPS system operating costs by reducing electricity consumption, heat
factor and IGBT rectifier with DSP control
emissions and cooling costs. Replacing 160 kVA of legacy UPS capacity with SmartOnline
create less than 4% input current Total
E3 UPS Systems can save more than $20,000 per year.
Harmonic Distortion (THDi). Low THDi
enables cost-saving 1:1 sizing of UPS
systems to generators, allows generators
to run cooler and extends the operational
lifespan of all input components. Low THDi
In addition, SmartOnline E3 UPS Systems automatically correct the widest range of
incoming voltages in their class. The wide voltage window and temperature-compensated
charging combine to significantly decrease battery wear, extending service life and
reducing replacement costs.
also reduces sizing requirements for cables
and breakers and improves reliability by
eliminating nuisance breaker tripping and
overheated transformers.
EFFICIENCY CHART
100%
INSTALLATION COST COMPARISON
SmartOnline E3’s
Extreme
Efficiency
Advantage
Cabling
Breakers
Related Costs
EFFICIENCY
SmartOnline E3
SmartOnline E3
Generators
85%
Legacy UPS
Legacy UPS
70%
50%
75%
100%
LOAD
Cost
SmartOnline E3 UPS Systems reduce
installation costs up to 30% versus
legacy UPS systems.
SmartOnline E3’s extreme efficiency can reduce your data center’s
operating costs significantly. Replacing 160 kVA of legacy capacity
can reduce power costs more than $20,000 per year.
GREEN POWER
CUMULATIVE ENVIRONMENTAL IMPACT OVER FIVE YEARS
Eco-friendly SmartOnline E3
Legacy UPS Energy Usage (MWh)
1956
UPS Systems save energy
1
and reduce your carbon
1752
SmartOnline E3 Energy Usage (MWh)
1310
1174
Legacy UPS CO2 Emissions (Tons)
footprint. Replacing 160 kVA
SmartOnline E3 CO2 Emissions (Tons)
of legacy UPS capacity can
3911
reduce CO2 emissions by 136 tons and
3504
2
2621
save more than 200 megawatt-hours of
2348
electricity per year—enough to power 16
typical U.S. single-family homes.
5867
5256
3
3931
SmartOnline E3 UPS Systems
3522
are also RoHS compliant,
which means they adhere
to strict standards in the
7823
7008
4
5241
reduction of six hazardous
substances:
hexavalent
biphenyls
lead,
mercury,
chromium,
(PBB)
and
4695
cadmium,
9779
polybrominated
polybrominated
8760
5
6552
5869
diphenyl ether (PBDE). Tripp Lite is an
industry leader in RoHS compliance.
Replacing 160 kVA of legacy UPS capacity with SmartOnline E3 can save 200 megawatt-hours (enough to power 16 U.S.
homes) and reduce CO2 emissions by 136 tons (enough to offset 2,000+ flights from New York to Washington) per year.
5
MONITORING
AND CONTROL
POWERALERT NETWORK MANAGEMENT SYSTEM
Convenient communication and management
features allow you to monitor power conditions,
receive automatic alerts and control SmartOnline
E3 UPS Systems with drift-proof digital precision
from any distance.
• DRY CONTACT CLOSURE INTERFACE
Connects to an Emergency Power Off (EPO) circuit for emergency UPS system shutdown. Also allows the UPS system to monitor external battery cabinets and communicate PowerAlert allows you to manage
up to 250 UPS systems from a single workstation.
Real-Time Power
Status Consoles
operational messages.
SmartOnline E3 UPS Systems support remote management through
PowerAlert software or the SNMPWEBCARD accessory.
• RS-232 SERIAL PORT
Connects to a server for shutdown
commands and reporting through PowerAlert software (included).
• ACCESSORY CARD SLOT
Optional network card (SNMPWEBCARD) provides remote monitoring and
control. Optional environmental
sensor (ENVIROSENSE) monitors The LED/LCD control panel provides detailed UPS status information.
temperature, humidity and more.
• NETWORK POWER MANAGEMENT
Dry Contact Closure Interface
Through PowerAlert software or SNMPWEBCARD, you can manage up to 250 UPS systems with PowerAlert Network Accessory
Card Slot
Management System (included) or a
third-party network management system.
• LED/LCD CONTROL PANEL
Offers convenient push button control
and communicates operational modes, 1+1
Parallel
Interface
RS-232
Serial
Port
The rear panel includes several communication interfaces.
conditions and warnings.
BATTERY CABINETS
All SmartOnline E3 UPS Systems can be connected to one or more external
battery cabinets:
• Model SU40K has internal batteries and does not require an external battery cabinet. External battery cabinets can be connected for expanded runtime.
• Other models do not have internal batteries and require an external
battery cabinet. Additional battery cabinets can be connected for
expanded runtime.
External battery cabinets are available in a variety of capacities. Models
BP480V26B and BP480V40C support temperature-compensated charging for
optimal charge levels and increased battery lifespan. They also match the
appearance and footprint of the UPS system cabinets. Larger models have
heavy-gauge steel cabinets with 10-year design life batteries.
BP480V26B
6
BP480V40C
COMPACT FOOTPRINT
Each SmartOnline E3 UPS System packs enough power for multiple racks
of equipment into a compact footprint, saving valuable data center floor
space for critical systems and cooling. Wall-mounted distribution and
bypass panels do not require additional floor space.
ORDERING INFORMATION
MODEL
OUTPUT CAPACITY
NOMINAL INPUT/OUTPUT VOLTAGE
BATTERY CONFIGURATION
SU40K
40 kVA / 32 kW
120/208 VAC (3Ø, 4-wire + ground, wye)
Internal batteries; external battery cabinet optional.
SU60K
60 kVA / 48 kW
120/208 VAC (3Ø, 4-wire + ground, wye)
No internal batteries; external battery cabinet required.
SU80K
80 kVA / 64 kW
120/208 VAC (3Ø, 4-wire + ground, wye)
No internal batteries; external battery cabinet required.
SU60KTV
60 kVA / 48 kW
277/480 VAC (3Ø, 4-wire + ground, wye)
No internal batteries; external battery cabinet required.
SU80KTV
80 kVA / 64 kW
277/480 VAC (3Ø, 4-wire + ground, wye)
No internal batteries; external battery cabinet required.
EXTERNAL BATTERY CABINETS (Hardwire connection. Multiple cabinets can be daisy-chained.)
BP480V26B
+/- 240 VDC external battery cabinet. Supports temperature-compensated battery charging for optimal charge levels and
increased battery lifespan. Cabinet matches appearance and footprint of UPS system cabinet.
BP480V40C
+/- 240 VDC external battery cabinet. Supports temperature-compensated battery charging for optimal charge levels and
increased battery lifespan. Cabinet matches appearance and footprint of UPS system cabinet.
BP480V55
+/- 240 VDC external battery cabinet. Heavy-gauge steel cabinet with 10-year design life batteries.
BP480V78
+/- 240 VDC external battery cabinet. Heavy-gauge steel cabinet with 10-year design life batteries.
BP480V103
+/- 240 VDC external battery cabinet. Heavy-gauge steel cabinet with 10-year design life batteries.
BP480V140
+/- 240 VDC external battery cabinet. Heavy-gauge steel cabinet with 10-year design life batteries.
WALL-MOUNTED EXTERNAL MAINTENANCE BYPASS PANELS WITH KEYED SAFETY INTERLOCK SYSTEM
SU40KMBPK
Maintenance bypass panel for SU40K only. Keyed safety interlock system prevents sequence of operation errors.
SU60KMBPK
Maintenance bypass panel for SU60K only. Keyed safety interlock system prevents sequence of operation errors.
SU80KMBPK
Maintenance bypass panel for SU80K only. Keyed safety interlock system prevents sequence of operation errors.
SU60KMBPKX
Maintenance bypass panel for SU60KTV only. Keyed safety interlock system prevents sequence of operation errors.
SU80KMBPKX
Maintenance bypass panel for SU80KTV only. Keyed safety interlock system prevents sequence of operation errors.
WALL-MOUNTED PARALLEL DISTRIBUTION PANELS (Required for 1+1 parallel connection of UPS systems.)
SUPC2MBP40K
Parallel distribution panel for 1+1 parallel connection of SU40K models only.
SUPC2MBP60K
Parallel distribution panel for 1+1 parallel connection of SU60K models only.
SUPC2MBP80K
Parallel distribution panel for 1+1 parallel connection of SU80K models only.
SUPC2MBP60KTV
Parallel distribution panel for 1+1 parallel connection of SU60KTV models only.
SUPC2MBP80KTV
Parallel distribution panel for 1+1 parallel connection of SU80KTV models only.
POWER MANAGEMENT ACCESSORIES
SNMPWEBCARD
Adds Ethernet network interface to UPS system for remote monitoring and control via SNMP, Web or telnet.
ENVIROSENSE
Monitors temperature and humidity. Monitors up to 3 additional sensors via dry contact closure interface.
Requires SNMPWEBCARD.
WARRANTIES AND SERVICES
Site survey services, start-up services, preventive maintenance services, extended warranties and on-site warranties are available.
Visit www.tripplite.com or contact your Tripp Lite sales representative for more information.
7
TECHNICAL SPECIFICATIONS
MODEL
SU40K
SU60K
277/480 VAC
(3Ø, 4-wire + ground, wye)
94~150 / 163~260 VAC (Full Load)
65~150 / 113~260 VAC (≤ 70% Load)
218~348 / 378~603 VAC (Full Load)
151~348 / 262~603 VAC (≤ 70% Load)
INPUT
< 4%
POWER FACTOR (On-line, Full Load)
> 0.99
FREQUENCY (Auto-Selectable)
50/60 Hz
FREQUENCY TOLERANCE
± 5%
97 A
145 A
193 A
63 A
84 A
CAPACITY (VA)
40,000 VA
60,000 VA
80,000 VA
60,000 VA
80,000 VA
CAPACITY (Watts)
32,000 W
48,000 W
64,000 W
48,000 W
64,000 W
POWER FACTOR
0.8 Per Phase
OUTPUT
NOMINAL VOLTAGE
120/208 VAC
277/480 VAC
FREQUENCY
50/60 Hz ± 0.05 Hz
NOMINAL CURRENT
111 A
167 A
222 A
WAVEFORM (On-line or Battery)
THD (Linear Load)
≤ 3%
VOLTAGE REGULATION (Static)
± 1%
BREAKERS
RECTIFIER (3-Pole, 600 VAC)
75 A
125 A
150 A
125 A
150 A
BYPASS (3-Pole, 600 VAC)
150 A
225 A
300 A
100 A
125 A
RESERVE (3-Pole, 600 VAC)
150 A
225 A
300 A
100 A
125 A
OUTPUT (3-Pole, 600 VAC)
150 A
225 A
300 A
100 A
125 A
BATTERY (Negative Pole, 600 VDC)
100 A
150 A
150 A
100 A
150 A
STANDARD INTERFACE
LED/LCD Control Panel with Event Log, RS-232, Dry Contact Closure, EPO (Local and Remote)
OPTIONAL INTERFACE
SNMPWEBCARD, ENVIROSENSE
On-line, Double Conversion
AGENCY APPROVALS
UL 1778, cUL, FCC Class A, RoHS
EFFICIENCY
Up to 96%
TRANSFER TIME (On-line Mode)
0 ms
AMBIENT OPERATING TEMPERATURE
GENERAL
96 A
≤ 125% for 10 minutes; ≤ 150% for 60 seconds; > 150% for 1 second
UPS TOPOLOGY
32° F to 104° F (0° C to 40° C)
ELEVATION
0 to 10,000 ft (0 to 3,000 m)
≤ 90%
HUMIDITY (Non-Condensing)
NOISE (1 m)
< 65 dBA
13/5.5+ min
25/8+ min
20/6+ min
25/8+ min
25/6+ min
(Internal Batteries)
(BP480V40C)
(BP480V40C)
(BP480V40C)
(BP480V40C)
Height
66.9 in (1,699 mm)
66.9 in (1,699 mm)
66.9 in (1,699 mm)
66.9 in (1,699 mm)
66.9 in (1,699 mm)
Width
20.5 in (521 mm)
20.5 in (521 mm)
20.5 in (521 mm)
20.5 in (521 mm)
20.5 in (521 mm)
Depth
33.7 in (856 mm)
37.7 in (958 mm)
38.8 in (986 mm)
33.7 in (856 mm)
33.7 in (856 mm)
1,513 lb (688 kg)
1,178 lb (535 kg)
1,444 lb (656 kg)
995 lb (452 kg)
1,105 lb (502 kg)
1,690 lb (768 kg)
1,356 lb (616 kg)
1,643 lb (747 kg)
1,175 lb (534 kg)
1,286 lb (585 kg)
TYPICAL RUNTIME* (Half/Full Load)
DIMENSIONS
(Power Module)
UNIT WEIGHT
**
(Power Module)
SHIPPING WEIGHT** (Power Module)
**
72 A
Pure Sine Wave
OVERLOAD CAPACITY
*
SU80KTV
120/208 VAC
THDi (Full Load) CURRENT
NOMINAL CURRENT
SU60KTV
(3Ø, 4-wire + ground, wye)
NOMINAL VOLTAGE
VOLTAGE RANGE
SU80K
Runtime varies with load, battery condition and other factors. Runtime can be extended by adding additional external battery cabinets, sold separately.
The weight of model SU40K includes internal batteries.
8
SMARTONLINE T3 UPS SYSTEMS
RELIABLE OPERATION
VERSATILE BATTERY SYSTEM
SmartOnline T3 UPS Systems protect your equipment from power
All SmartOnline T3 UPS Systems scale to fit your runtime
problems, including surges, line noise, harmonic distortion,
requirements through an expandable, hot-swappable battery
electrical impulses, frequency variations, brownouts, overvoltages
system with convenient front-panel access:
and blackouts. On-line operation continually transforms AC
• Model SU20K3/3 includes 2 internal battery packs and has input power into filtered DC power, then resynthesizes it into
room to add 2 additional battery packs.*
precision-regulated AC output with a pure sine wave. Reliable
• Model SU30K3/3 includes 3 internal battery packs and has backup power with zero transfer time to battery keeps equipment
room to add 1 additional battery pack.*
operating safely through shorter power failures and allows time to
shut down or switch to generator power during longer outages.
• Extended-runtime models (SU20K3/3XR5 and SU30K3/3XR5) Fault-tolerant bypass features keep your equipment powered at
each include 5 internal battery packs and have room to add
all times—even if the UPS system requires maintenance, repair
3 additional battery packs.*
or replacement.
• All models can also be connected to one or more compact external battery cabinets (SUBF2030). Each external battery COMPACT FOOTPRINT
cabinet holds up to 4 battery packs, sold separately.*
SmartOnline T3 UPS Systems have an all-in-one form factor that
• Larger-capacity external battery cabinets with 10-year design combines the power module and battery system. They pack
life batteries are also available.
enough power for multiple racks of equipment into a compact
*
Battery pack model SURBC2030.
footprint that saves valuable data center floor space for critical
systems and cooling. Wall-mounted distribution and bypass
panels do not require additional floor space.
+ _ + _
+ _ OPEN
+ _ + _
SU20K3/3
SU30K3/3
OPEN OPEN
OPEN OPEN
+ _ OPEN
+ _ + _
+ _ + _
SU20K3/3XR5
OPEN OPEN
+ _ OPEN
+ _ + _
+ _ + _
SU30K3/3XR5
OPEN OPEN
OPEN OPEN
SUBF2030
External Battery Cabinet
SURBC2030
Internal Battery Pack
SmartOnline T3 UPS Systems combine the power module
and battery system in a single compact footprint.
You can increase battery backup runtime by installing
additional internal battery packs and/or external battery
cabinets. External battery cabinets support daisy-chaining.
9
MONITORING AND CONTROL
POWERALERT NETWORK MANAGEMENT SYSTEM
Convenient communication and management features allow
you to monitor power conditions, receive automatic alerts and
control SmartOnline T3 UPS Systems from any distance.
• COMMUNICATION PORTS
RS-232, AS/400 and dry contact closure ports connect to servers for shutdown commands and reporting through PowerAlert software (included). An Emergency Power Off
(EPO) jack connects to your facility’s EPO circuit for emergency UPS system shutdown.
• ACCESSORY CARD SLOT
PowerAlert allows you to manage
up to 250 UPS systems from a
single workstation.
Optional network card (SNMPWEBCARD) provides remote monitoring and control. Optional dry contact closure accessory card (RELAYIOCARD) provides 6 outputs and Real-Time Power
Status Consoles
SmartOnline T3 UPS Systems support remote management through
PowerAlert software or the SNMPWEBCARD accessory.
1 input.
• NETWORK POWER MANAGEMENT
Through PowerAlert software or SNMPWEBCARD, you can manage up to 250 UPS systems with PowerAlert Network Management System (included) or a third-party network management system.
• LED/LCD CONTROL PANEL
Offers convenient push button control and communicates The LCD/LED control panel indicates more than 45 separate
faults, warnings and operational conditions.
operational modes, conditions and warnings.
ORDERING INFORMATION
MODEL
OUTPUT CAPACITY
BATTERY CONFIGURATION
SU20K3/3
20 kVA / 16 kW
Includes 2 internal battery packs; room for 2 additional SURBC2030 battery packs.
SU20K3/3XR5
20 kVA / 16 kW
Includes 5 internal battery packs; room for 3 additional SURBC2030 battery packs.
SU30K3/3
30 kVA / 24 kW
Includes 3 internal battery packs; room for 1 additional SURBC2030 battery pack.
SU30K3/3XR5
30 kVA / 24 kW
Includes 5 internal battery packs; room for 3 additional SURBC2030 battery packs.
BATTERY EXPANSION (Multiple battery cabinets can be daisy-chained.)
SURBC2030
240 VDC internal battery pack for SmartOnline T3 UPS Systems and SUBF2030 external battery cabinets.
SUBF2030
External battery cabinet. Requires SURBC2030 battery packs (up to 4 per cabinet), sold separately.
BP240V99
240 VDC external battery cabinet with 10-year design life batteries.
BP240V120
240 VDC external battery cabinet with 10-year design life batteries.
BP240V1207C
240 VDC external battery cabinet with 10-year design life batteries. Built-in battery charger.
BP240V150
240 VDC external battery cabinet with 10-year design life batteries.
BP240V1507C
240 VDC external battery cabinet with 10-year design life batteries. Built-in battery charger.
WALL-MOUNTED EXTERNAL MAINTENANCE BYPASS PANELS WITH KEYED SAFETY INTERLOCK SYSTEM
SU20KMBPK
Maintenance bypass panel for 20 kVA models. Keyed safety interlock system prevents sequence of operation errors.
SU30KMBPK
Maintenance bypass panel for 30 kVA models. Keyed safety interlock system prevents sequence of operation errors.
POWER MANAGEMENT ACCESSORIES
SNMPWEBCARD
Adds Ethernet network interface to UPS system for remote monitoring and control via SNMP, Web or telnet.
ENVIROSENSE
Monitors temperature and humidity. Monitors up to 3 additional sensors via dry contact closure interface.
Requires SNMPWEBCARD.
RELAYIOCARD
Programmable dry contact closure accessory card with 6 output contacts and 1 input contact.
WARRANTIES AND SERVICES
Site survey services, start-up services, preventive maintenance services, extended warranties and on-site warranties are available.
Visit www.tripplite.com or contact your Tripp Lite sales representative for more information.
10
TECHNICAL SPECIFICATIONS
MODEL
SU20K3/3
SU20K3/3XR5
INPUT
NOMINAL VOLTAGE
VOLTAGE RANGE
96~144 / 166~250 VAC
FREQUENCY (Auto-Selectable)
50/60 Hz ± 3 Hz
> 0.95
NOMINAL CURRENT
OUTPUT
SU30K3/3XR5
120/208 VAC (3Ø, 4-wire + ground, wye)
POWER FACTOR (On-line, Full Load)
53 A
79 A
CAPACITY (VA)
20,000 VA
30,000 VA
CAPACITY (Watts)
16,000 W
24,000 W
POWER FACTOR
0.8 Per Phase
NOMINAL VOLTAGE
120/208 VAC
FREQUENCY
50/60 Hz ± 0.1 Hz
NOMINAL CURRENT
56 A
83 A
WAVEFORM (On-line or Battery)
Pure Sine Wave
THD (Linear Load)
≤ 3%
VOLTAGE REGULATION (Static)
± 2%
OVERLOAD CAPACITY
≤ 125% for 60 seconds; ≤ 150% for 30 seconds; > 150% for 2 seconds
MAIN INPUT PROTECTION
200 A / 150 VAC Fuse x 3
STANDARD INTERFACE
LED/LCD Control Panel, RS-232, AS/400, Dry Contact Closure, EPO (Local and Remote)
OPTIONAL INTERFACE
SNMPWEBCARD, ENVIROSENSE, RELAYIOCARD
UPS TOPOLOGY
On-line, Double Conversion
AGENCY APPROVALS
UL 1778, cUL, FCC Class A, NOM
EFFICIENCY
TYPICAL RUNTIME* (Half/Full Load)
INCLUDED INTERNAL BATTERY PACKS
GENERAL
SU30K3/3
INTERNAL BATTERY PACK CAPACITY**
Up to 93%
13/5+ min
42/17+ min
13/5+ min
25/11+ min
(Internal Batteries)
(Internal Batteries)
(Internal Batteries)
(Internal Batteries)
2
5
3
5
4
8
4
8
(Can Add 2)
(Can Add 3)
(Can Add 1)
(Can Add 3)
TRANSFER TIME
0 ms
AMBIENT OPERATING TEMPERATURE
32° F to 104° F (0° C to 40° C)
ELEVATION
0 to 10,000 ft (0 to 3,000 m)
≤ 95%
HUMIDITY (Non-Condensing)
NOISE (1 m)
< 65 dBA
UNIT HEIGHT
35.9 in (912 mm)
50.9 in (1,293 mm)
35.9 in (912 mm)
50.9 in (1,293 mm)
UNIT WIDTH
25.4 in (645 mm)
25.4 in (645 mm)
25.4 in (645 mm)
25.4 in (645 mm)
UNIT DEPTH
36.8 in (935 mm)
36.8 in (935 mm)
36.8 in (935 mm)
36.8 in (935 mm)
UNIT WEIGHT (Standard Configuration)
519 lb (236 kg)
979 lb (444 kg)
660 lb (299 kg)
999 lb (453 kg)
SHIPPING WEIGHT (Standard Configuration)
607 lb (275 kg)
1,133 lb (514 kg)
748 lb (339 kg)
1,153 lb (523 kg)
*
Runtime shown for standard internal battery configuration. Runtime varies with load, battery condition and other factors. Runtime can be extended by adding
internal battery packs and/or external battery cabinets, sold separately. ** Add internal battery pack model SURBC2030, sold separately.
11
WARRANTIES AND SERVICES
ABOUT TRIPP LITE
Since 1922, Tripp Lite has established a global reputation for
quality by providing customers with reliable, cost-effective
products and responsive service. After introducing the first
desktop UPS system and the popular Isobar® surge suppressor
in the early eighties, Tripp Lite became the gold standard for
power protection in the growing information technology sector.
More than 6 million UPS systems and 16 million Isobars later,
loyal customers in over 60 countries choose Tripp Lite to power,
protect and connect equipment ranging from home electronics
to servers and network equipment in enterprise data centers.
SmartOnline 3-Phase UPS Systems include a 1-year limited
Tripp Lite manufactures more than 1,000 products, including UPS
warranty backed by Tripp Lite’s experienced service and
systems, replacement batteries, PDUs, power management tools,
support team. Tripp Lite also offers a variety of on-site
rack systems, surge suppressors, KVM switches, cables, power
warranties, extended warranties, start-up services and
strips, inverters, inverter/chargers, line conditioners and specialty
service contracts for UPS systems and battery cabinets.
products for healthcare and audio/video applications. Tripp Lite’s
Tripp Lite’s expert service technicians can assist in every
heritage of invention is reflected today in practical innovations
phase of your implementation, from site planning and
that address customer needs without ignoring fiscal realities:
start-up to preventive maintenance and rapid repair. Contact
Tripp Lite for more information.
• SmartOnline™ Hot-Swappable UPS Systems keep critical servers, storage and network equipment running 24x7, even during UPS maintenance, repair or replacement.
• SmartPro® CRM UPS Systems deliver best-in-class wattage and battery capacity in shallow-depth cabinets optimized for network/telecom wiring closets.
• Green power solutions save money and protect the environment. Economy mode operation and high-efficiency UPS designs conserve energy
while cutting electricity bills and carbon
emissions. Eco-friendly manufacturing across every product line enables industry-leading
RoHS (Restriction of Hazardous Substances) compliance for a cleaner, greener planet.
Distributed By:
TRIPP LITE WORLD HEADQUARTERS
1111 W. 35th Street, Chicago, IL 60609 USA
773.869.1234 • www.tripplite.com
Copyright © 2009 Tripp Lite. All trademarks are the sole property of their respective owners. Tripp Lite has a policy of continuous improvement.
Specifications are subject to change without notice. Photos may differ slightly from final products.
201010076 95-2916