UL508 Certifications (copy of online Directory)

20080616-E210002
E210002, 2008 June 06
2008 June 16
Issued to:
CONVERTEC LTD
WHITEMILL INDUSTRIAL ESTATE
WEXFORD
IRELAND
This is to certify that
representative samples of
POWER CIRCUIT AND MOTOR-MOUNTED APPARATUS
Open Type, Industrial Control Equipment, Switching Power Supply
See Addendum Page 1 for Models
Have been investigated by Underwriters Laboratories Inc.® in
accordance with the Standard(s) indicated on this Certificate.
Standard(s) for Safety:
Additional Information:
UL 508 - Industrial Control Equipment, Seventeenth Edition
UL 840 - Insulation Coordination Including Clearances and Creepage Distances
for Electrical Equipment
C22.2 No. 107-01 - General Use Power Supplies
See Addendum Page 2 for Ratings
Only those products bearing the UL Listing Mark for the US and Canada should be
considered as being covered by UL's Listing and Follow-Up Service meeting the
appropriate requirements for US and Canada.
The UL Listing Mark for the US and Canada generally includes: the UL in a circle symbol
with “C” and “US” identifiers:
the word “LISTED”; a control number (may be
alphanumeric) assigned by UL; and the product category name (product identifier) as
indicated in the appropriate UL Directory.
Look for the UL Listing Mark on the product
Issued by:
Reviewed by:
Paul Mulvenna, Project Engineer
Matteo Redaelli, Group Leader Engineer
Underwriters Laboratories Inc.
Underwriters Laboratories Inc.
20080616-E210002
E210002, 2008 June 06
2008 June 16
This is to verify that representative samples of the product as specified on this certificate were tested
according to the current UL requirements.
Models
TBL015-105, TBL015-112, TBL015-124, TBL030-112, TBL030-124, TBL060-112, TBL060-124,
TBL090-112, TBL090-124, 015PSL181, 015PSL182, 015PSL184, 030PSL182, 030PSL184,
060PSL182, 060PSL184, 090PSL182, 090PSL184, INFA 005.024, INFA 012.012, INFA 024.006,
INFA 012.025, INFA 024.012, INFA 012.045, INFA 024.025, INFA 012.060 and INFA 024.038
Issued by:
Reviewed by:
Paul Mulvenna, Project Engineer
Matteo Redaelli, Group Leader Engineer
Underwriters Laboratories Inc.
Underwriters Laboratories Inc.
20080616-E210002
E210002, 2008 June 06
2008 June 16
This is to verify that representative samples of the product as specified on this certificate were tested
according to the current UL requirements.
ELECTRICAL RATINGS:
Model
TBL015-105 or 015PSL181 or
INFA 005.024
TBL015-112 or 015PSL182 or
INFA 012.012
TBL015-124 or 015PSL184 or
INFA 024.006
TBL030-112 or 030PSL182 or
INFA 012.025
TBL030-124 or 030PSL184 or
INFA 024.012
TBL060-112 or 060PSL182 or
INFA 012.045
TBL060-124 or 060PSL184 or
INFA 024.025
TBL090-112 or 090PSL182 or
INFA 012.060
TBL090-124 or 090PSL184 or
INFA 024.038
Input
V ac
A
Hz
Output,(dc)
V dc
A
100-240
0.33-0.19
50/60
5
2.4
W
Max.
12
100-240
0.38-0.24
50/60
12
1.25
15
100-240
0.38-0.24
50/60
24
0.63
15
100-240
0.9-0.5
50/60
12
2.5
30
100-240
0.9-0.5
50/60
24
1.25
30
100-240
1.3-0.8
50/60
12
4.5
54
100-240
1.4-0.9
50/60
24
2.5
60
100-240
1.75-1.00
50/60
12
6.0
72
100-240
2.2-1.2
50/60
24
3.75
90
Issued by:
Reviewed by:
Paul Mulvenna, Project Engineer
Matteo Redaelli, Group Leader Engineer