DC/DC Converter TZL Series, 60 to 300 Watt Features ◆ Compact metal case with screw terminal block ◆ Wide 2:1 input range ◆ I/O isolation 1500VDC ◆ Input reverse polarity protection ◆ No minimum load required ◆ Soft start, low inrush current ◆ Overload and short circuit protection ◆ EMC compliance with EN 61000-6-1 and EN 50082-1 ◆ Adjustable output voltage ◆ 3-year product warranty This range of boxed DC/DC converter are designed for all applications, where high reliability and long lifetime are important. They provide excellent electric specifications and full compliance to the European EMC and low voltage directive. International safety approvals qualify these converter for worldwide use. With their low profile case and screw terminal block they are easy to install in any equipment. Models Order code TZL 060-2412 TZL 060-2424 TZL 060-4812 Output power 18 - 36 VDC 60 Watt 36 - 72 VDC TZL 060-4824 TZL 100-2412 TZL 100-2424 TZL 100-4812 19 - 36 VDC 100 Watt 36 - 72 VDC TZL 100-4824 TZL 150-2412 TZL 150-2424 TZL 150-4812 19 - 32 VDC 150 Watt 36 - 72 VDC TZL 150-4824 TZL 300-4812 TZL 300-4824 http://www.tracopower.com Input voltage 300 Watt 36 - 72 VDC Output voltage nom. 12 VDC Output current max. 5.0 A 24 VDC 2.5 A 12 VDC 5.0 A 24 VDC 2.5 A 12 VDC 8.5 A 24 VDC 4.2 A 12 VDC 8.5 A 24 VDC 4.2 A 12 VDC 12.5 A 24 VDC 6.3 A 12 VDC 12.5 A 24 VDC 6.3 A 12 VDC 26.7 A 24 VDC 13.4 A Page 1 of 5 Enclosed Power Supplies TZL Series 60–300 Watt Input Specifications Input current (at full load) TZL 060 models TZL 100 models TZL 150 models TZL 300 models 19 Vin 4.6 A typ. 8.0 A typ. 12 A typ. -- Recommended circuit breaker (characteristic C) or slow blow fuse 5A 10 A 15 A 20 A TZL 060 TZL 100 TZL 150 TZL 300 models models models models 36 Vin 2.4 A typ. 4.0 A typ. 6.3 A typ. 30 A typ. Output Specifications Output voltage adjustment range Regulation ±10 % – Input variation 1 % max. – Load variation (10–100%) 1 % max. Minimum Load not required Ripple and noise (20 MHz bandwidth) 12 VDC output <100mVpk-pk 24 VDC output<150mVpk-pk Output current limitation 105 % – 150 % of Iout max. Overload protection mode Fold back, automatic recovery Over voltage protection (only output 1) 115 % – 140 % of Vout nom. Short circuit protection foldback, automatic recovery Capacitive load, max. TZL 060: 12 VDC / 24 VDC TZL 100: 12 VDC / 24 VDC TZL 150: 12 VDC / 24 VDC TZL 300: 12 VDC / 24VDC output output output output models models models models 11’000 µF / 2‘000 µF 14’200 µF / 1‘000 µF 8’600 µF / 470 µF 2’700 µF / 1‘000 µF General Specifications Temperature ranges – Operating –10°C to +60°C – Load derating above 50°C 2.5 %/K – Storage (non operating) –10°C to +75°C Temperature coefficient 0.03 %/°C Efficiency ~80 % (depending on model and load) Humidity (non condensing) 85 % rel max. (non condensing) Switching frequency 50 kHz typ. (pulse width modulation) Hold-up time 20 ms min. Isolation voltage (60sec.) – Input/Output 1‘500 VAC – Input/Case 1‘500 VAC – Output/Case 500 VAC Reliability /calculated MTBF (MIL-HDBK-217F, at+25°C, ground benign) >250’000 h Electromagnetic compatibility (EMC) EN 61000-6-1 Electromagnetic compatibility (EMC), radiated emission EN 55022, class B Casing material Environmental compliance cover: nickel plated steel chassis: natural aluminium – Reach www.tracopower.com/overview/tzl – RoHS RoHS directive 2011/65/EU All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated. http://www.tracopower.com Page 2 of 5 Enclosed Power Supplies TZL Series 60–300 Watt 19 18 3 x M3 THD 10 max. 118 19 (4.65) (0.75) 159 10 +Vin –Vin NC –Vout –Vout +Vout +Vout (6.26) (0.39 max.) Dual & Triple output models 2 x M3 THD (bottom) Single output (3.74) Top view 95 1 2 3 4 5 6 7 32 1 2 3 4 5 6 7 8 9 (1.26) 1 2 3 4 5 6 7 (0.39) Connection (0.75) TZL 060 Series (0.71) Case Dimensions 78 57 38 (3.07) (0.95) (1.50) Weight: 0.7 kg (25 oz) 20 (6.22) 10 158 (0.79) 10 max. 198 19 (0.75) 18 +Vin –Vin NC –Vout –Vout +Vout +Vout (7.80) (0.39 max.) Single output 120 (4.72) 16.5 (0.45) Caution! Max mounting screw penetration: 3.0 mm (0.12) (3.74) 4 x M3 THD (bottom) 95 (3.15) Top view (0.35) Dual & Triple output models 1 2 3 4 5 6 7 80 1 2 3 4 5 6 7 8 9 9 1 2 3 4 5 6 7 (0.39) 3 x M3 THD Connection (0.71) TZL 100 Series Weight: 38 (1.50) 0.8 kg (28 oz) Dimensions in [mm], () = Inch Tolerances ±0.8 (0.03) Monting hole pich tolerances ±0.5 (0.02) http://www.tracopower.com Page 3 of 5 Enclosed Power Supplies TZL Series 60–300 Watt 25 (0.49) 117 176.5 13 max. 56 (4.61) (2.20) (0.98) 12.5 21 (0.83) 6 x M4 THD (0.49) TZL 150 Series 12.5 Case Dimensions 11.5 (6.95) (0.45) 198 (7.83) (0.51 max.) 168 (6.61) 63 (2.48) 99 49.5 10 (2.56) (0.39) +Vin 65 (3.9) (3.11) 2 x M4 thread (bottom) (1.95) NC N –Vin L Top view 79 4 x M3 THD (bottom) 28 Vout V adj. RC + RS + (1.10) + + 50 (1.97) 10 (0.39) Caution! Max mounting screw penetration: 3.0 mm (0.12) Weight: 0.89 kg ( 31 oz) Dimensions in [mm], () = Inch Tolerances ±0.8 (0.03) Monting hole pich tolerances ±0.5 (0.02) http://www.tracopower.com Page 4 of 5 Enclosed Power Supplies TZL Series 60–300 Watt 12 max. 29.5 (5.91 ±0.03) (1.16) 212 (0.98 ±0.03) 150 ±0.8 25 ±0.8 4 x M4 THD 12.5 TZL 300 Series (0.49) air flow Outline Dimensions (8.35) (0.47 max.) 150 29.5 (5.91) (1.16) 87.5 (3.44) 177.5 (6.99) 7 (4.53) 115 50 (1.97) 32.5 95 (3.74) +Vin 10 L –Vin 5 x M3 THD (bottom) (0.39) N NC 54.5 4 x M4 THD (bottom) (2.15) Vout + + + (1.28) V adj. RC + RS + 50 (1.97 ) (0.28) Weight: 1.05 kg (37 oz) Caution! Max mounting screw penetration: 3.0 mm (0.12) Dimensions in [mm], () = Inch Tolerances ±0.8 (0.03) Monting hole pich tolerances ±0.5 (0.02) Specifications can be changed without notice! Make sure you are using the latest documentation, downloadable at www.tracopower.com www.tracopower.com Rev. June 23. 2015 Page 5 of 5