TXH

Metal Case Power Supplies
TXH Series, 120­–480 Watt
CB
Scheme
Features
◆ Compact U-bracket and enclosed power
UL 60950-1
supplies
◆ Screw terminal block
◆ Very high efficiency up to 93 %
◆ No internal fan for 120 W & 240 W
models.
◆ Universal input 90 – 264 VAC
◆ Adjustable output voltage
◆ EMI/EMC compliance with EN 61000-6-3
and EN 61000-6-1
◆ Compliance to EN 61000-3-2 (PFC)
◆ Short circuit and overvoltage protection
◆ 3-year product warranty
The TXH series is a family of power supplies in metal enclosure, designed for a wide
range of cost critical applications. The very high efficiency of up to 93% admits
of a compact design with free air convection coouling for the 120 and 240 Watt
models. The units are equiped with screw terminal blocks and are easy to install in
any equipment.
These power supplies have universal input and comply with European EMC standards and the Low Voltage Directive (LVD).
Models with Single Output
Order code
Output power
max.
Output Voltage [VDC]
Output current
max.
Efficiency
typ. at 230 VAC
11.4 – 13.2
10 A
90 %
22.8 – 26.4
5.0 A
91 %
48
45.6 – 52.0
2.5 A
92 %
12
11.4 – 12.6
20 A
90 %
nominal *
adjustable
12
24
TXH 120-148
TXH 240-112
TXH 120-112
TXH 120-124
TXH 240-124
120 Watt
240 Watt
24
22.8 – 25.2
10 A
92 %
TXH 240-148
48
45.6 – 50.4
5.0 A
93 %
TXH 360-112
12
10.8 – 13.2
30 A
89 %
24
21.6 – 26.4
15 A
91 %
48
44.0 – 51.0
7.5 A
93 %
12
10.8 – 13.2
40 A
88 %
24
21.6 – 26.4
20 A
90 %
48
43.2 – 50.4
10 A
91 %
TXH 360-124
360 Watt
TXH 360-148
TXH 480-112
TXH 480-124
480 Watt
TXH 480-148
* 36 VDC output voltage models on request.
http://www.tracopower.com
Page 1 of 5
Metal Case Power Supplies
TXH Series
120–480 Watt
Input Specifications
Input voltage
– nominal 100 – 240 VAC
– AC range (universal input) 90 – 264 VAC
– DC range 120 – 370 VDC
Input frequency 47 – 63 Hz
Earth leakage current (240 VAC / 63 Hz)
360 W models: 300 µA max.
other models:500 µA max.
Input current at full load
– at 115 VAC / 230 VAC
120
240
360
480
W
W
W
W
models:
models:
models:
models:
1.2 A typ. / 0.6 A typ.
2.3 A typ. / 1.1 A typ.
3.6 A typ. / 1.8 A typ.
5.1 A typ. / 2.5 A typ.
Recommended circuit breaker
(characteristic C) or slow blow fuse
120
240
360
480
W
W
W
W
models: models:
models: models:
3.15 A
5A
6.3 A
10 A
Output Specifications
Voltage set accuracy ±2 % max.
Output voltage adjustment range Regulation
details see table page 1
– Input variation 1 % max.
– Load variation (0–100%) 1 % max.
Minimum load not required
Ripple and noise (20 MHz bandwidth) [mVp-p] max.
Models: 12 VDC
120 W 120
240 W 120
360 W 150
480 W 100
24 VDC
240
200
200
200
48 VDC
480
200
200
300
Hold-up time 10 ms min.
Current limitation 130 - 150 % foldback, auto recovery
Short circuit protection indefinite,
360 & 480 W models: auto recovery
120 & 240 W models: no auto recovery (power disconnect required)
Overvoltage protection by Zener diode 120 % of Vout typ.
360 & 480 W models: auto recovery
120 & 240 W models: no auto recovery (power disconnect required)
Overtemperature protection for 360 & 480 W models only, auto recovery
Capacitive load, [µF] max. Models: 12 VDC
120 W 23‘000
240 W 23‘000
360 W 85‘000
480 W 180‘000
24 VDC
10‘000
10‘000
48‘000
75‘000
48 VDC
470
470
13‘000
25‘000
General Specifications
Temperature ranges
– Operating
120 W models:
480 W models:
other models:
– Storage (non operating)
–25°C to +70°C
–20°C to +70°C
–10°C to +70°C
–25°C to +85°C
Derating
– Ambient temperature
– Low input voltage
2.5 %/K above +50°C
low temperature derating for TXH480-112
model: 2%K below 5°C
below 100 VAC: 1%/V
Temperature coefficient 0.03 %/K
Humidity (non condensing) 95 % rel max.
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.tracopower.com
Page 2 of 5
Metal Case Power Supplies
TXH Series
120–480 Watt
General Specifications
Switching frequency (pulse width modulation PWM)
120 & 240 W models: 100 kHz typ.
360 W models: 75 kHz typ.
480 W models: 62.5 kHz typ.
Isolation voltage (60 sec.) – Input / Output
120 & 240 W models:
360 & 480 W models:
– Input / Case
120 & 240 W models:
360 & 480 W models:
– Output / Case
4‘000 VAC
3‘000 VAC
2‘000 VAC
1‘500 VAC
500 VAC
Reliability /calculated MTBF 120 & 360 W models: >120‘000 h
(MIL-HDBK-217F, at +25°C, ground benign)
240 W models: >50’000 h
480 W models: >100’000 h
Electromagnetic compatibility – Conducted input RI suppression EN 55022, class B, FCC part 15, level B
(EMC), Emissions
– Harmonic current emissions IEC/EN 61000-3-2 class B
Electromagnetic compatibility EN 55024
(EMC), Immunity Degree of protection class I
Safety standards UL 60950-1, IEC/EN 60950-1
Safety approvals – UL/cUL 60950-1 www.ul.com -> certifications -> File e188913
– CB report according to IEC 60950-1 www.tracopower.com/products/txh-cb.pdf
Environment – Vibration 3 axes, sine sweep, 10–500Hz, 2g, 0.1 oct/min
Environmental compliance
– Reach www.tracopower.com/products/txh-reach.pdf
– RoHS RoHS directive 2011/65/EU
Altitude during operation 120 / 240 & 360 W models: up to 4‘000 m (13‘120 ft) approved
480 W models: up to 3‘000 m (9‘840 ft) approved
Outline Dimensions
137.0 (5.39)
TXH 120 models
6.0 (0.24)
4.0 (0.16)
38.0 (1.50)
Weight: 390 g (13.8 oz)
Optional Cover
TXH 120–COV
Cover incl. screws for TXH 120 models
100.0 (3.94)
50.0 (1.97)
13.0
(0.51)
13.5
(0.53)
82.0 (3.23)
12.0 12.0
–Vout
10.8
(0.43)
41.0
–Vout
AC IN (N)
(1.61)
+Vout
AC IN (L)
FG
(0.47) (0.47)
+Vout
top view
60.5 (2.38)
7x M3 THD
(bottom)
Max mounting screw penetration: 2.5 mm (0.1)
http://www.tracopower.com
Page 3 of 5
Metal Case Power Supplies
TXH Series
120–480 Watt
Outline Dimensions
150.0 (5.91)
35.0 (1.38)
TXH 240 models
Weight: 580 g (20.5 oz)
127.0 (5.00)
Optional Cover
57.0 (2.24)
11.5
(0.45)
Cover incl. screws for TXH 240 models
7x M3 THD
(bottom)
+Vout
106.0 (4.17)
(0.47) (0.47)
–Vout
53.0
AC IN (L)
AC IN (N)
FG
(0.83)
21.25
Max mounting screw penetration: 2.5 mm (0.10)
Terminal rating: 25A
At higher current connection has to be splitted
–Vout
(2.09)
top view
63.5 (2.50)
+Vout
12.0 12.0
TXH 240–COV
13.0
(0.51)
TXH 360 models
Weight: 750 g (26 oz)
10.0
5x M4 THD
1 FG
2 AC IN (N)
3 AC IN (L)
4~6 +DC OUT
7~9 -DC OUT
15.7
4x M4 THD
4.5
Dimensions in [mm], () = Inch
Tolerances ±0.8 (±0.03)
Mounting hole pich tolerances ±0.5 (±0.02)
http://www.tracopower.com
Max mounting screw penetration: 2.5 mm (0.10)
Terminal rating: 25A
At higher current connection has to be splitted
Page 4 of 5
Metal Case Power Supplies
TXH Series
120–480 Watt
Outline Dimensions
150.0 (5.91)
- Sense
13.0
57.0 (2.24)
11.5
(0.51)
(0.45) = Off
DC-OK: 4-6
VDC = On, 0-1 VDC
C6
GND
C7
+5 VDC aux. ±10%, 0.6 A max.
M3 THD
C87x
(bottom)
GND aux.
+Vout
–Vout
–Vout
53.0
(2.09)
top view
+Vout
63.5 (2.50)
C5
Remote127.0
Control:
open = On, short = Off
(5.00)
106.0 (4.17)
C4
AC IN (L)
AC IN (N)
FG
Input terminal
1
AC (N)
2
AC (L)
3
FG
(0.83)
C3
12.0 12.0
Connection cable with 500mm
flying leads included!
+ Sense
C2
(0.47) (0.47)
Mating connector:
Housing: JST PHDR-08VS
Crimp: JST SPHD-002T-P0.5
C1
35.0 (1.38)
Weight: 1050 g (37 oz)
Control connector
21.25
TXH 480 models
Output terminal
4-6
+ Vout
7-9
- Vout
Max mounting screw penetration: 2.5 mm (0.10)
Terminal rating: 25A
At higher current connection has to be splitted
Dimensions in [mm], () = Inch
Tolerances ±0.8 (±0.03)
Mounting hole pich tolerances ±0.5 (±0.02)
Specifications can be changed without notice! Make sure you are using the latest documentation, downloadable at www.tracopower.com
www.tracopower.com
Rev. January 17. 2014
Page 5 of 4