Datasheet

SIF 6 Series
Circuit Diagram (view on relay upper side)
-- PCB Relay with forcibly guided contacts
-- Protective separation between coil and contacts
(>5,5 mm) and contacts side by side (>5,5 mm)
-- EN50205 type A
-- Double and reinforced insulation
-- SMD arrangement below relay possible
-- Contact mounting: SIF422
4 NO / 2 NC
-- Compact height: only 10,9 mm
-- Nominal coil power 0,66 W
-- Holding coil power 0,20 W
-- For railway application (EN50155) on request
54
34
12
1,2
2,2
**
1,5
3,3
4,1
3,1
Ø1,3
*
[mm]
21
22
A2
1,5
-- Double or reinforced insulation
at 250 VAC
-- Air and creepage distance
>5,5 mm
-- Test voltage
4000 V / 50 Hz / 1 min
1500 V / 50 Hz / 1 min
Test voltage contact oopen
Creepage resistance
CTI 175
Pollution degree
2
Overvoltage category
III
Insulation resistance at Up 500 VDC
>100 MΩ
Additional Data
3,1
1,6
11
44
* Do not drill when SMD arrangement
** Open breathing hole
Contact Data
Contact material
AgCuNi + 0,2 µm Au
Type of contact
Single contact with notched crown
Rated switching capacity 250 VAC 8 A AC1 2000 VA
Electr. life AC 1(360 cycles / h)
approx.100000
Inrush current max.
30 A for 20 ms
Switching voltage range
5 to 250 VDC / VAC
Switching current range*
3 mA to 8 A
Switching capacity range*
40 mW to 2000 W(VA)
Contact resistance (as delivered)
≤100 mΩ / 6 V / 100 mA
*Guided values
Standard coils for direct current
Nominal voltage
VDC
Min. pick-up voltage
at 20 °C
Drop-out voltage at
20 °C
Nominal current
in mA
Resistance in Ohm
at 20 °C
(other voltages on request)
5
12
18
20
24
48
60
110
≤3,5
≤8,4
≤12,6
≤14,0
≤16,8
≤33,6
≤42,0
≤77,0
≥0,5
≥1,2
≥1,8
≥2,0
≥2,4
≥4,8
≥6,0
≥11,0
133,3
55,8
38,9
33,3
27,5
13,8
11,1
6,0
37,5 ± 10%
215 ± 10%
490 ± 10%
600 ± 10%
870 ± 10%
3460 ± 10%
5400 ± 13%
18300 ± 15%
Mechanical endurance
>10 x 106 operations
Switching frequency, mechanical
15 Hz
Response time (all NO closed)
typically 20 ms
Drop-out time** (all NC closed)
typically 8 ms
Bounce time of NO contact
typically 1,5 ms
typically 15 ms
Bounce time of NC contact
Shock resistance 16 ms
NO > 10g
NC > 6g
Vibration resistance
NO > 10g
(10-200 Hz)
NC > 2g
Resistance to short circuiting NO
1000 A SCPD 10 A gG / gL (pre-fuse)
Resistance to short circuiting NC
1000 A SCPD 6 A gG / gL (pre-fuse)
Ambient temperature
-40°C to +70°C
Thermal Resistance
47 K / W
Temperature limit for coil
120°C
Weight
ca. 35 g
Mounting position
any
Type of protection
RT II
Solder bath temperature
270°C / 5 s
AC 1:230V
DC 13: 24V
10
0,1
0,5
1,0
Switching Current (A) →
5,0
10
Maximal switching characteristics (DIN EN 60947-5-1)
AC 1: 250 V / 8 A
AC 15: 230 V / 5 A
24 V / 8 A
DC 1:
DC 13: 24 V / 5 A / 0,1 Hz
UL 508: B300 / R300
Maximal contact load at AC 1 with 230 V:
2 contacts with 8 A each
3 contacts with 6 A each
4 contacts with 4,5 A each
Load Limit Curve with Direct Current
8
6
4
3
2
1
1
0,8
0,6
0,4
0,3
0,2
0,1
0
2
50
100
150
Voltage (VDC) →
200
250
1)Inductive load L/R 40 ms
2)Resistive load
Excitation Voltage Range
3,0
2,5
Tests, Regulations
2,0
1
1,5
UL File E188953
Insulation class IEC 60664-1
Protection class II
Fire protection requirements
Options, Accessories
Sec. 6
250 VAC
VDE 0106
UL 94 / V0
1,0
0,5
UB
UN 0
2
0
20
40
60
Ambient Temperature °C →
80
100
1)Max. excitation voltage with contact load: ≤5 A
2)Min. excitation voltage (guaranteed values) without
previous operation
none available
Product Key
SIF 422 24VDC
Coil voltage
Soldering tags
Number of NC contacts
Number of NO contacts
Type designation
ELESTA GmbH, Heuteilstrasse 18, Fon:
CH - 7310 Bad Ragaz, Switzerland Fax:
AC 15: 230V
100
**without spark suppression
Approvals
DC 1: 24V
1000
Insulation Data
0,5
15,8
*
*
33,5
30,4
1,6
15,4 7,5 7,5
1
15,8
*
**
43
Current (A) →
3,1
10,9
2,9
15,8
33
10000
64
SIF422
53,6
47,4
4,1
3,1
63
A1
Dimensions
3,1
53
Contact Lifetime for NO Contacts
Operations x 1000 →
Relay Key Data
+41 (0)81 303 54 00
+41 (0)81 303 54 01
No heat accumulation due to intrinsic heating of
other components. Continuous duty 100%.
© Copyright
09/2014