S60D125 - Teledyne Relays

Series S
Single Output to 660 Vac
AC/DC Control
Part Numbers
Package & Line
Chip Type Voltage1
S
Switch
Type2
24
S
48
Output Feature3
Current
R
12
D
25
A
40
R
25
D
50
-22
-22
125
S
60
D
Part Number Example: S48A25-22
50
NOTES
1) Line Voltage (nominal): 24 = 240 Vac; 48 = 480 Vac; 60 = 600 Vac
2) Switch Type: R = Random turn-on; D = Zero-cross turn-on;
A = AC control, Zero-cross turn-on
3) Feature: -22 = 24 Vac control. Available on A type 240 Vac, 25 and 40A
models and A type 480 Vac, 25, 50, 125A models
125
For RoHS Compliant Contact Factory
MECHANICAL SPECIFICATION
1.06 (27)
(p0.5)
1.1 (28)
.77 (19.6)
1~
2~
4-
3+
1.02 (25.8)
1 (25.4)
1.75 (44.5)
M3
TOLERANCES: p.01 (0.3)
WEIGHT: 3.18 oz. (90g)
Figure 1 — S relays, 12–95 A;
dimensions in inches (mm)
125A model uses larger M5 output screw terminals
TYPICAL APPLICATION
Line Voltage
Line Protection
-
4–
1
3+
2
Control
+
FEATURES/BENEFITS
• Industry standard package
• Internal snubber (except S60 models)
• Designed for all types of loads
• AC or DC control available
• Excellent thermal performance
• Tight zero-cross window for low EMI
• High immunity to surges
M4
.2 (5.1)
1.7 (43.2)
.26 (7.5)
2.29 (58.2)
Ø.19 (Ø4.7)
1.87 (47.6)
(p.02)
.9 (22.8)
DESCRIPTION
The Series S single-phase relays are designed for
all types of loads. The design incorporates an SCR
or triac output. The relays utilize optical isolation to
protect the control from load transients. All contain an
internal snubber for output protection. High-current
models are excellent for motor and phase angle
control.
APPLICATIONS
• Heating control
• Motor control
• Uninterruptible power supplies
• Light dimmers
• Industrial and process control
• On/Off controls of AC equipment
APPROVALS
S24 and S48 models are UL recognized.
UL File Number: E128555.
* 1-2 can be changed
* SSR must be mounted on a heat sink
Figure 2 — S relays
© 2014 TELEDYNE RELAYS
LOAD
(800) 284-7007 • www.teledynerelays.com
S Page 1
S\072014\Q3
Series S
Single Output to 125A 660 Vac
AC/DC Control
INPUT (CONTROL) SPECIFICATION
Min
Max
CONTROL CHARACTERISTICS
Units
Control Range
R
3
30
Vdc
D
4
30
Vdc
S48
R
4
30
Vdc
D
5
30
Vdc
S60
D
5
30
Vdc
SxxA
A
90
240
Vac/Vdc
Sxxxxx-22
A
17
80
Vac/Vdc
Input Current (mA)
S24
30
28
26
24
22
20
18
16
14
12
10
8
6
4
2
0
0
2
4
6
8
10 12 14 16 18 20 22 24 26 28 30
Control Voltage (V)
Input Current Range
R/D
3
30
mA
S
A
3
8
mA
Sxxxxx-22
A
5.6
26
mA
Must Turn-Off Voltage
S
R/D
1
Vdc
S24
A
15
Vac
S48
A
1
Vac
3
Vac
Sxxxxx-22
Figure 3b — S24D/R relays
8
Input Current (mA)
S
6
4
2
0
0
20
40
60
R/D
1000
S
A
30,000
Ohms
3000
Ohms
Sxxxxx-22
Ohms
Reverse Voltage Protection
S
A
30
V
NA
Figure 3c — S24A and S48A relays
30
Input Current (mA)
S
R/D
100 120 140 160 180 200 220 240
Control Voltage (V)
Input Resistance (Typical)
S
80
25
20
15
10
5
0
0
10
20
Input Current (mA)
CONTROL CHARACTERISTICS
30
40
50
60
70
80
Control Voltage (V)
Figure 3d — Sxxxxx-22 relays
28
26
24
22
20
18
16
14
12
10
8
6
4
2
0
0
2
4
6
8
10 12 14 16 18 20 22 24 26 28 30
Control Voltage (V)
Figure 3a — S48R, S48D and S60D relays
S Page 2
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2014 TELEDYNE RELAYS
S\072014\Q3
Series S
Single Output to 660 Vac
AC/DC Control
OUTPUT (LOAD) SPECIFICATION
OUTPUT (LOAD) SPECIFICATION (continued)
Min
Max
Units
Max
Units
S24
12
280
Vrms
12A output current
1.3
V
S48
24
520
S60
24
660
Vrms
25A output current
1.2
V
Vrms
40A output current
1.4
V
Operating Range
Min
On-State Voltage Drop
Peak Voltage
S24
600
Vpeak
S48
1200
Vpeak
S60
1600
Vpeak
Load Current Range (Resistive)
50A output current
1.4
V
125A output current
1.3
V
S60D125
1.1
V
Zero-Cross Window (Typical)
S
R
NA
V
S
D/A
±12
Vac
3
mA
12A output current
.005
12
Arms
25A output current
.005
25
Arms
40A output current
.005
40
Arms
S24
Off-State Leakage Current (60Hz)
50A output current
.005
50
Arms
S48
D/A
3
mA
125A output current
.005
125
Arms
S48
R
2.5
mA
S60
A
1
mA
0.1
ms
Inductive Load Current
12A output current
2.5
Arms
25A output current
5
Arms
Turn-On Time (60Hz)
S
R
40A output current
9
Arms
S
D
8.3
ms
50A output current
12
Arms
S
A
24.9
ms
125A output current
30
Arms
Turn-Off Time (60Hz)
Capacitive Load Current
S60D50
13
Arms
S60D125
48
Arms
S
R/D
8.3
ms
S
A
24.9
ms
Off-State dv/dt
500
V/ųs
Maximum di/dt (Non-repetitive)
50
A/ųs
Maximum Surge Current Rating (Non-Repetitive)
12A output current
120
A
S24, 25A output current
240
A
S48, 25A output current
230
A
40A output current
350
A
50A output current
550
A
125A output current
2000
A
© 2014 TELEDYNE RELAYS
(800) 284-7007 • www.teledynerelays.com
S Page 3
S\072014\Q3
Series S
Single Output to 125A 660 Vac
AC/DC Control
OUTPUT (LOAD) SPECIFICATION (continued)
Operating Frequency
Min
Max
Units
0.1
440
Hz
SURGE CURRENT
150
Non-Repetitive
Apeak
100
I²T for match fusing (<8.3ms)
50
12A output current
72
A²S
S24R25
312
A²S
S24D/S24A 25A output current
288
A²S
S48 25A output current
265
A²S
40A output current
612
A²S
250
50A output current
1500
A²S
200
125A output current
20000
A²S
Repetitive with initial Tj = 70°C
0
0.01
0.1
1
10
t(s)
Apeak
Figure 4a — 12A output current
150
Non-Repetitive
100
50
ENVIRONMENTAL SPECIFICATION
Repetitive with initial Tj = 70°C
0
Operating Temperature
S48D50
Min
Max
Units
-40
100
°C
-55
100
°C
0.01
0.1
t(s)
1
10
Figure 4b — 25A output current
400
-40
+100
Input-Output Isolation
4000
°C
300
Apeak
Storage Temperature
Vrms
Non-Repetitive
200
100
Repetitive with initial Tj = 70°C
0
0.01
Output-Case Isolation
0.1
1
10
t(s)
2500
Vrms
25A output current
2500
Vrms
40A output current,R
2500
Vrms
40A output current,D
3300
Vrms
40A output current,A
3300
Vrms
50A output current
3300
Vrms
125A output current
3300
Vrms
Figure 4c — 40A output current
600
Apeak
12A output current
400
Non-Repetitive
200
Repetitive with initial Tj = 70°C
0
0
0.1
1
10
t(s)
Figure 4d — 50A output current
2000
Apeak
1500
Non-Repetitive
1000
500
Repetitive with initial Tj = 70°C
0
0.01
0.1
t(s)
1
10
Figure 4g — 125A output current
S Page 4
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2014 TELEDYNE RELAYS
S\072014\Q3
Series S
Single Output to 660 Vac
AC/DC Control
THERMAL CHARACTERISTICS
T case
max (°C)
T case
max (°C)
1.6 ° C/W
Power Dissipation (W)
130
95
120
100
10
8
50% duty cycle
6
2
Full on state
0.7
0
1
2
3
4
5
6
7
8
9
10
11
12
0 10
20
30 40
Load Current (Arms)
50
60
70
80
100
5°
80
50% duty cycle
70
1.1
1 .6
T case
max (°C)
Load Current (Arms)
Ambient Temperature (°C)
Figure 5e — 125A output current
C/
W
/W
/W
0 10 20 30 40 50 60 70 80 90 100 110 120
5°
C
C
6° C/W
0 10 20 30 40 50 60 70 80 90 100 110120130140150
0.7
1°
6°
/W
C /W
70
1.
1.
°C
100
/W
0
0.95°C/W
Full on state
°C
2 .2°
10
Figure 5a — 12A output current
35
90
W
60
50
W
C/
20
Ambient Temperature (°C)
40
C/
0.9
90
30
90 100 110 120
80
5°
110
40
0
W
C/
W
5°
C/
70
0.5
140
90
4
80
2.2
30
Power Dissipation (W)
W
° C/
/W
6°
12
65
150
85
Full on state
14
160
°C
W
80
0.3
1 .1
C/
/W
16
°C
4°
2.2
18
170
Power Dissipation (W)
20
75
°C
/W
90
25
20
100
50% duty cycle
15
6°C
/W
10
NOTES:
1. Electrical specifications measured at 25°C unless otherwise
specified.
2. For 800Hz applications, contact factory.
3. For additional/custom options, contact factory.
OPTIONAL ADD-ONS
5
Please order add-ons separately:
• -12 — Thermal pad installed.
• -14 — Plastic touch-proof cover.
0
0
2
4
6
8
10
12
14
16
18
20
22
24
26
0
10
20
30
40
Load Current (Arms)
50
60
70
80
90 100 110 120
Ambient Temperature (°C)
Figure 5b — 25A output current
T case
max (°C)
0.5
W
W
C/
C/
70
75
/W
°C
50
W
1.1
Full on state
C/
5°
55
65
5°
5°
0.7
0.9
60
Power Dissipation (W)
45
80
1.6
°C
/W
40
35
85
90
2.2
°C
/W
30
95
50% duty cycle
100
25
20
15
6 °C
10
/W
5
0
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 0
10
20
Load Current (Arms)
30
40
50
60
70
80
90 100 110 120
Ambient Temperature (°C)
Figure 5c — 40A output current
T case
max (°C)
100
70
Power Dissipation (W)
50% duty cycle
40
80
C/
W
85
°C
1. 6
50
/W
Full on state
60
75
°C
1.1
/W
70
0.3
5°
80
W
°C
C/
0.9
55
5°
0.
0.7
90
90
/W
95
° C/
2.2
W
100
° C/
W
30
20
6 ° C/W
10
0
0
5
10
15
20
25 30
35
40
Load Current (Arms)
45
50
55
60
0
10
20 30
40
50 60
70 80
90 100 110 120
Ambient Temperature (°C)
Figure 5d — 50A output current
© 2014 TELEDYNE RELAYS
(800) 284-7007 • www.teledynerelays.com
S Page 5
S\072014\Q3