G24D12-06 - Teledyne Relays

NEW Series G
Output to 12A 280 Vac
DC Control
Part Number
Description
G24R12-06
12A, 280 Vac
G24D12-06
12A, 280 Vac
Part Number Explanation
G
24
R
12
-06
FEATURES/BENEFITS
• Miniature size package
• Power and control connections by Faston
terminals
• Internal VDR protection
• Excellent thermal performance
• High immunity to surges
NOTES
1) Line Voltage (nominal): 24 = 240 Vac
2) Switch Type: R = Random turn-on; D = Zero-cross turn-on
3) Feature: -06 = Faston terminals
MECHANICAL SPECIFICATION
1.0 (25.4)
.866 (22)
0.6 (15.24)
.25x.032
(6.35x0.8)
.49
(12.5)
.315
(8)
DESCRIPTION
The Series G relays are designed for medium-power
loads. The design incorporates a thyristor output. The
Series G relays utilize optical isolation to protect the
control from load transients. An internal MOV is also
provided to protect against transient voltages. Its
compact size makes it ideal for designs where space
is limited.
1.0 (25.4)
1.496 (38)
2.63 (66.8)
1.728 (43.9)
Ø5
2.24 (56.9)
Figure 1 — G relays; dimensions in inches (mm)
APPLICATIONS
• Heating control
• Motor control
• Light dimmers
• Industrial and process control
• On/Off controls of medium-power AC equipment
APPROVALS
UL pending.
INPUT (CONTROL) SPECIFICATION
Min
Max
Units
3
32
Vdc
Control Range
G24D
4
32
Vdc
G24R
2
30.5
mAdc
G24D
3
30.5
mAdc
Input Current Range
Must Turn-Off Voltage
Input Resistance (Typical)
Reverse Voltage Protection
1
Vdc
1000
Ohms
32
V
CONTROL CHARACTERISTIC
Input Current (mA)
G24R
32
30
28
26
24
22
20
18
16
14
12
10
8
6
4
2
0
0
2
4
6
8
10 12 14 16 18 20 22 24 26 28 30 32
Control Voltage (V)
Figure 2 — G relays
© 2003 TELEDYNE RELAYS
(800) 284-7007 • www.teledynerelays.com
G1
G\032003\Q1
Series G
OUTPUT (LOAD) SPECIFICATION
Min
TYPICAL APPLICATION
Max
Units
Operating Range (See Note 1) 12
320
Vrms
MOV Clamping Voltage @ 1mA
520
V
Output Current Range
12
Arms
12-280 Vac
.001
Line protection
–
Maximum Surge Current Rating (Non-Repetitive)
See Figure 4
260
On-State Voltage Drop
0.75(Ie)+0.02(Ie)2
4–
1~
3+
2~
Control
12-30 Vdc
A
+
V
• 1-2 can be changed
• SSR must be mounted on a heat sink
Zero-Cross Window (Typical)
LOAD
G24R
R
NA
G24D
D
±12
Vac
0.1
mA
Off-State Leakage Current (60Hz)
Figure 3 — G relays
SURGE CURRENT
250
Turn-On Time (60 Hz)
0.1
ms
FS24D
8.3
ms
Apeak
200
FS24R
Non-Repetitive
150
100
50
Repetitive with initial Tj = 70°C
Turn-Off Time (60 Hz)
8.3
ms
Off-State dv/dt
500
V/µs
Maximum di/dt (Non-Repetitive)
50
A/µs
Operating Frequency Range 0.1
440
Hz
I2t for Match Fusing (<8.3ms)
340
A2S
Thermal Resistance Junction to Case
5.6
°C/W
0
0.01
0.1
1
10
t(s)
Figure 4 — G relays output current
THERMAL CHARACTERISTICS
ENVIRONMENTAL SPECIFICATION
Min
Max
Units
Operating Temperature
–40
100
°C
Storage Temperature
–40
100
°C
Input-Output Isolation
4000
Vrms
Output-Case Isolation
4000
Vrms
Rated Impulse Voltage
4000
Vi
Load Current (Arms)
20
15
1.2K/W heat sink
10
2.6K/W heat sink
4K/W heat sink
5
0
0
10
20
30
40
50
60
70
80
90 100
Ambient Temperature (°C)
Figure 5 — G relays output current
NOTES:
1. Maximum voltage limited by MOV.
2. Electrical specifications at 25°C unless otherwise specified.
3. For 800Hz applications, contact factory.
4. For additional/custom options, contact factory.
G2
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2003 TELEDYNE RELAYS
G\032003\Q1