BP200-12 - BB

VRLA Rechargeable Battery
Measures
BP200-12
FEATURES
Technology
Values
Innovation
APPLICATION
Maintenance free(no water topping-up required).
No free acid(Non-spillable battery).
Low self-discharge rate, lower than 3% capacity loss per month.
Can be used in any orientation(excluding used inverted).
Flame-arrestor is installed to ensure safety.
Carry handles for easy installation.
Absorbent Glass Mat technology for efficient gas recombination.
UPS
Telecom
SPECIFICATIONS
Nominal Voltage
Nominal Capacity
Approx. Weight
12 V
200Ah @ 20 hour rate F.V.(1.75V/cell)
61.5Kg(135.6lbs.)
B9 (Fitting M8 bolt & nut) I3 is optional
2.5m (Fully Charged )
800 A (5 sec.)
60 A
Charge 0oC~40oC(32oF~104oF)
Discharge -20oC~50oC(-4oF~122oF)
Storage. -20oC~40oC(-4oF~104oF)
Standard: ABS( UL 94-HB) BP200-12
Optional: Flame Retardant ABS(UL 94-V0) BP200-12FR
Terminals
Internal Resistance
Max. Discharge Current
Max. Charge Current
Operating Temperature Range
Container Material
DIMENSION(mm/inch)
M8x1.25
522
2 (20.55
0.08)
202
2 (7.95
0.08)
[M8 BOLT & NUT]
[M8 BOLT]
Terminal Hardware Initial Torque: B9 ,I3(10.0Nm±5%)
Constant power discharge characteristics at 25 oC/77 oF
Discharge
Time
Terminal I3
Terminal B9
3.5(0.14)
Total Height
B9:240±2.0 (9.45±0.08)
I3:220±2.0 (8.66±0.08)
TERMINAL TYPE
240 2 (9.45 0.08)
216 2 (8.50 0.08)
Length
522±2.0 (20.55±0.08)
Width
202±2.0 (7.95±0.08)
Container Height
216±2.0 (8.50±0.08)
OUTER DIMENSIONS
IEC 60896-21/22
JIS C 8704-2
GB/T 19638.2
Unit: W
15 Min
30 Min
1 Hr
3 Hr
5 Hr
10 Hr
20 Hr
1.80V
3724
2537
1456
582.8
402.0
224.6
118.2
1.75V
3896
2634
1499
594.6
408.0
228.0
120.0
1.70V
4016
2694
1526
600.0
410.3
229.2
120.6
1.65V
4108
2731
1545
604.3
411.7
229.7
120.9
1.60V
4190
2760
1560
607.7
412.8
229.7
120.9
20 Hr
F.V.
(V/cell)
o
o
Constant current discharge characteristics at 25 C/77 F
Discharge
Time
Unit: A
15 Min
30 Min
1 Hr
3 Hr
5 Hr
10 Hr
1.80V
323.8
215.0
122.3
48.57
33.50
18.71
9.85
1.75V
338.8
223.2
126.0
49.55
34.00
19.00
10.00
1.70V
349.2
228.3
128.3
50.00
34.19
19.10
10.05
1.65V
357.2
231.5
129.8
50.36
34.31
19.14
10.08
1.60V
364.4
233.9
131.1
50.64
34.40
19.14
10.08
F.V.
(V/cell)
All data and artworks shall be changed without prior notice, BB reserves the right to explain and update the information contained hereinto.
A/3
REV. Mar. 2013
Powered by
B.B. Battery Co., Ltd.