Data sheet OSRAM OT 50/120

product details
OT 50/120-277/10 E UNV1
Product description:
EAN/ Product:
Quantity:
OT 50/120-277/10 E UNV1
4050300861500
Unpacked (UNV) contains 1 Piece (PCE)
Applications
Dimmable
Yes 1)
IP code
IP64
Short-circuit protection
automatic reversible
Overload protection
automatic reversible
Overtemperature protection
automatic reversible
General Description
Design / version
ECG standard
SEG no.
5280343
Standards
acc. to IEC 61347-2-13 | acc. to IEC 62384 | acc. to EN 55015 | acc. to IEC 610003-2 | acc. to EN 61000-3-3 | acc. to EN 61547 | acc. to UL 1310 | acc. to UL 48 |
acc. to UL879A | FCC 47 part 15 clas
Sstl-Number
4031166
Technical - Electrical Data
Mains frequency
50-60 Hz
TH full width at half maximum
150 µs 2)
Device power loss
... 5 W 3)
Lamp wattage
50 W 4)
Power factor c
> 0.95
Nominal voltage
120-277 V
Output voltage
10.5 ± 0.5 V
Max. no. of ECGs on circuit breaker 10A
7
Max. no. of ECGs on circuit breaker 16A
12
Mains current max.
0.51 A
Technical - Geometries
Mounting hole spacing, length
227 mm
Width
43 mm
Height
30 mm
Length
241 mm
Max. cable length - system in meters
10 m
Technical - Temperatures
Max. casing temp. in case of fault
110 °C
Max. operating temp. at the Tc point
90 °C
Ambient temperature range
-25 ... +60 °C
Storage temperature
-40 ... 85 °C
Relative humidity
5 ... 85 % 5)
Packaging units
EAN
Packaging type and content
Dimensions in h x w x l
Gross weight
Volume
4050300861500
Unpacked contains 1 Piece
49,000 mm x 45,000 mm x 241,000 mm
623,333 g (0,000 g)
0,531 Cubic
dec.
4050300861517
Shipping carton box contains 10 Piece
262,000 mm x 119,000 mm x 262,000 mm
6.200,000 g (0,000 g)
8,169 Cubic
dec.
1)
with OPTOTRONIC dimmers
product details
OT 50/120-277/10 E UNV1
2)
at 240 VAC
3)
maximum at 230 V<sub>AC</sub>, P<sub>out</sub>=maximum, Ta=25°C, steady state
4)
at 100% luminous flux
5)
max. 56 d/y at 85%
Geometry
product details
OT 50/120-277/10 E UNV1
earthing
Wiring diagram
Installations notes
Instruction sheet
Please consult the instruction sheet for further important information on dimming
characteristic, wire stripping and wiring limitations in system installations. The instruction
sheet is available upon request.
Case must be grounded with a mounting screw (see fig.)
Pay attention to the installation instructions which can be found in the packaging.