www.osram.com/lms Light Management Systems: Energy Savings. Complete LMS range for daylight-dependent and presence-dependent lighting. ENERGY-SAVING LMS Good for our climate and good for your business: LMS Energy Savings. © spectral Gesellschaft für Lichttechnik mbH; Anin Jeromin Fitilidis & Partner, Architekten & Ingenieure; LOOK UP GmbH & Co. KG, Agentur für Kommunikation Constantly rising energy costs and a growing focus on climate protection are driving the need for energy savings more and more into the forefront. Particularly in applications with high energy consumption, energy-efficient lighting solutions are assuming an increasingly important role. Only as much light as needed. In daylight-dependent and motion/presence-dependent lighting control systems, the available daylight in a room is supplemented as needed by artificial light from luminaires with dimmable electronic ballasts. Light sensors detect the lighting level comprising artificial light and natural daylight. The groups of luminaires are controlled according to their position in the room and the amount of available daylight, so that a predefined lighting level is maintained. Users can adjust the lighting at any time to a level that meets their specific needs. If a motion/presence sensor is also used, the lighting is automatically switched on only when someone enters an empty room or if someone is in the room. This significantly increases the potential energy savings even further. 2 For intelligent luminaires to lighting solutions for open-plan offices. In the LMS Energy Savings sector, OSRAM offers alternative solutions to cover a variety of requirements. • Touch DIM® (Single luminaires) • MULTIeco (Single and group offices) • MULTI 3 (Strip lighting, hallways) • Sensoren (Sensors for stand-alone solutions) TOUCH DIM® Simple dimming without a controller or dimmer switch: Touch DIM®. OSRAM has come up with a cost-effective idea for providing simple lighting control with DALI® ECGs. A new function has been added to DALI® ECGs: Touch DIM®. The benefits of Touch DIM®: • Standard switches can be used • Radio version for flexible upgrade solutions • Switch-on value can be saved in the ECG by double-clicking • Suitable for fluorescent lamps, LV halogen lamps, and LED modules • Versions: Touch DIM®, Touch DIM® Remote, Touch DIM® Sensor Photo: © Waldmann Dimming with line voltage. With Touch DIM® it is now possible to dim and switch the control gears directly with line voltage at the DALI® control terminals. There is no longer any need for a separate controller, as the ECG itself acts as the controller. 3 TOUCH DIM® Touch DIM® – Dimming without a dimmer switch. Touch DIM® Sensor – for intelligent single luminaires. Applications: • Simple manual dimming using conventional switches • For individual offices or small conference rooms Technical attributes: • Maximum total control cable length 25 m • Extendable by respectively 64 ECGs and a cable length of 300 m with the DALI® Repeater (cascadable system size) • 2 mA control current per ECG • Double-click to save switch-on value Applications: • Daylight-dependent control with presence function and combination option for individual adjustment of the lighting level • For intelligent luminaires Technical attributes: • Compact dimensions for unobtrusive installation of luminaires • A set point for daylight-dependent control can be stored by double-clicking • TOUCH DIM® Sensor available purely as a light sensor, purely as a presence sensor with 4 different sensor elements, or as a combination sensor for light and presence • Stand-by consumption < 0.5 W Optional: DALI® REPEATER Dimmable 1…100 % Dimmable 0,2…100 % Dimmable 0,2…100 % Light and presence sensor Up to 6 QTi DALI® ECGs Up to 6 HTi DALI® ECGs Up to 6 OTi DALI® ECGs Products: • QTi DALI® ECG for fluorescent lamps • HTi DALI® ECG for LV halogen lamps • OTi DALI® ECG for LED modules Dimmable 1…100 % Dimmable 0,2…100 % Dimmable 0,2…100 % Up to 4 QTi DALI® ECGs Up to 4 HTi DALI® ECGs Up to 4 OTi DALI® ECGs Up to 64 DALI® ECGs Products: • QTi DALI®/HTi DALI®/OTi DALI® ECG • Touch DIM® LS/PD LI luminaire installation sensor TOUCH DIM® PRODUCT OVERVIEW TOUCH DIM® LS/PD LI – Light and presence sensor, luminaire installation. TOUCH DIM® LS LI – Light sensor, luminaire installation. • • • • • • • • • • Light and presence sensor Can also operate purely as a presence sensor Signal line length: max. 10 m Power draw: max. 0.5 W Delay time: 15 min A set point for daylight-dependent control can be stored by double-clicking • Approx. 80° angle of detection, detection area max. diameter 5 m, max. 5 m installation height • Operated via standard switches • Up to 4 QTi DALI® ECGs or 4 HTi DALI® ECGs or 4 OTI DALI® ECGs can be connected Light sensor Signal line length: max. 10 m Power draw: max. 0.5 W A set point for daylight-dependent control can be stored by double-clicking • Operated via standard switches • max. 4 m installation height • Up to 4 QTi DALI® ECGs or 4 HTi DALI® ECGs or 4 OTI DALI® ECGs can be connected TOUCH DIM® PD LI 2P WOS – Presence sensor. • Presence sensor with sensor head extension: 25 cm • Different sensor elements available: spot type, 5 m type, 10 m type, type for small movements • Signal line length: max. 10 m • Power draw: max. 0.5 W • Delay time: 15 min • Operated via standard switches • Angle of detection, detection area, and max. installation height dependent on sensor element selected • Up to 4 QTi DALI® ECGs or 4 HTi DALI® ECGs or 4 OTI DALI® ECGs can be connected 5 TOUCH DIM® SYSTEM OVERVIEW Touch DIM® Radio switch Remote control TD WCU TD RMC Standard switch User interface ** Sensors Sensor SWITCH RC TD RC TD LS LI TD LS/PD LI TD PD LI 2P WOS Controller / Receiver SOLAR ECG / Ballast Switching contact * HTM® * OT QTi DALI® HTi DALI® OTi DALI® 75 Light sources * QT 6 Additional information on all radio products can be found in the brochure “Components” * Non-dimmable QT, HT, and OT electronic control gears ** Battery-less radio standar MULTIECO Clever system for single and group offices: MULTIeco. The compact modular light management system MULTIeco offers varied daylight-dependent and presence-dependent lighting control with minimal standby consumtion power. The right solution for every need. MULTIeco is extremely versatile. The controller is available in a DALI® version, a 1…10 V version, and a switching version. There are also six different light and presence sensors for luminaire and ceiling installation. Possible applications include offices, restrooms, and common areas. The benefits of MULTIeco: • Standby consumption < 0.5 W • Luminaire integration or independent mounting with ECO CI KIT • Control of up to 20 ECGs • Extremely compact dimensions • Already meets the Swiss MINERGIE® Directive and the EU Ecodesign Specifications planned for 2012 7 MULTIECO DALI® MULTIeco in the office. Energy-efficient light management for offices. Simple operation and versatile functions make DALI® MULTIeco an ideal light control system for office areas. The perfect solution here is a daylight-dependent control combined with presence detection. The 50 mm small mini ceiling installation sensor for light and presence detection Produkte: • DALI® MULTIeco controller • ECO CI KIT • LS/PD MULTI 3 CI ceiling installation sensor 8 do not interfere with the ceiling look or the architecture of the room. The controller can be installed in the intermediate ceiling, in the small distributor, or directly in the luminaire. The entire installation is extremely simple and can also be done afterwards. DALI® MULTIeco. DIM MULTIeco. • Up to 75 %* energy savings compared to conventional solutions • 14 different operating modes can be set over DIP switches MULTIeco. • Up to 75 %* energy savings compared to conventional solutions • 14 different operating modes can be set over DIP switches DALI® MULTIeco • Up to 45 %* energy savings compared to conventional solutions • 8 different operating modes can be set over DIP switches DIM MULTIeco MULTIeco 1…10 V Up to 10 ECGs Up to 2 Sensors Up to 10 ECGs Up to 2 Sensors Up to 20 ECGs** Up to 2 Sensors Connectable sensors (see also page 10) LS/PD MULTI 3 FL LS/PD MULTI 3 LS/PD MULTI 3 B LS/PD MULTI 3 CI LS/PD MULTI 3 A LS/PD MULTI 3 A-W * Compared to conventional systems: T8 lamp, conventional control gear, no sensors ** Taking into consideration the load capacity of the switching contact 9 MULTIECO PRODUCT OVERVIEW 10 LS/PD MULTI 3 – Light and presence sensor, luminaire installation. LS/PD MULTI 3 FL – Light and presence sensor, luminaire installation, flat. • Connection via modular 4p4c connector • Connecting cable length: 2.1 m (detachable) • Approx. 80° angle of detection, detection area max. diameter 5 m, max. 4 m installation height • • • • LS/PD MULTI 3 B – Light and presence sensor, luminaire installation, moveable. LS/PD MULTI 3 CI – Light and presence sensor, ceiling installation, moveable. • • • • • • • • Moveable sensor head Connection via modular 4p4c connector Connecting cable length: 2.1 m (permanently connected) Approx. 80° angle of detection, detection area max. diameter 5 m, max. 4 m installation height Low-profile casing design Connection via modular 4p4c connector Connecting cable length: 2.1 m (permanently connected) Approx. 80° angle of detection, detection area max. diameter 5 m, max. 4 m installation height Ceiling installation sensor with moveable sensor head Connection via modular 4p4c connector/screw terminals Surface mounting with SENSOR KIT Approx. 80° angle of detection, detection area max. diameter 5 m, max. 4 m installation height LS/PD MULTI 3 A – Light and presence sensor, luminaire installation, pluggable. LS/PD MULTI 3 A-W – Light and presence sensor, luminaire installation, pluggable, white. • • • • • Luminaire mounting possible via provided clip • Connection via modular 4p4c connector • High-temperature cable (125°), white, connecting cable length: 2.1 m (detachable) • Approx. 80° angle of detection, detection area max. diameter 5 m, max. 4 m installation height Luminaire mounting possible via optional clip Connection via modular 4p4c connector Connecting cable length: 2.1 m (detachable) Approx. 80° angle of detection, detection area max. diameter 5 m, max. 4 m installation height DALI® MULTIeco controller. DIM MULTIeco controller. MULTIeco controller. • Suitable for daylight-dependent control with presence function • Standby consumption: max. 0.5 W • Integrated load contact for disconnection • Complies with MINERGIE® and EU Ecodesign requirements planned for 2012 • 14 different operating modes can be set up via DIP switches for daylight-dependent and presence-dependent lighting control • Independent installation possible with ECO CI KIT • Up to 2 sensors can be connected (compatible with all MULTI 3 sensors) • Up to 10 DALI® ECGs can be connected • Potential energy savings of up to 75 %* • Suitable for daylight-dependent control with presence function • Standby consumption: max. 0.5 W • Integrated load contact for disconnection • Complies with MINERGIE® and EU Ecodesign requirements planned for 2012 • 14 different operating modes can be set up via DIP switches for daylight-dependent and presence-dependent lighting control • Independent installation possible with ECO CI KIT • Up to 2 sensors can be connected (compatible with all MULTI 3 sensors) • Up to 10 1…10-V ECGs can be connected • Potential energy savings of up to 75 %* • Suitable for daylight-dependent control with presence function • Standby consumption: max. 0.5 W • Integrated load contact • Complies with MINERGIE® and EU Ecodesign requirements planned for 2012 • 8 different operating modes can be set up via DIP switches for daylight-dependent and presence-dependent lighting control • Independent installation possible with ECO CI KIT • Up to 2 sensors can be connected (compatible with all MULTI 3 sensors) • Up to 20 ECGs can be connected (if the contact load capacity is exceeded, an external power relay is required) • Potential energy savings of up to 45 %* SENSOR KIT – Adapter for surface mounting. ECO CI KIT – Installation kit. • Adapter for surface mounting the EASY IR CI receiver element • Can be used for separate mounting of all OSRAM controllers measuring 118 × 30 × 21 mm (L × W × H) * Compared to conventional systems: T8 lamp, conventional control gear, no sensors 11 MULTIECO SYSTEM OVERVIEW MULTIeco Standard switch User interface Sensors Controller / Receiver LS/PD MULTI 3 LS/PD MULTI 3 FL LS/PD MULTI 3 B LS/PD MULTI 3 CI DALI® MULTIeco LS/PD MULTI 3 A LS/PD MULTI 3 A-W DIM MULTIeco MULTIeco Switching contact ECG / Ballast 1...10 V DIM HTi DALI® OTi DALI® 75 QTi DIM HT 1…10 V ** OT DIM * QT * OT Light sources QTi DALI® 12 * Non-dimmable QT, HT, and OT electronic control gears ** Suitable power supply required MULTI 3 Flexible and powerful: Light group control with MULTI 3. With its sophisticated functions and modular design, the MULTI 3 system offers versatile design options for intelligent and cost-effective energy-saving solutions New standards. With a height of only 21 mm, the MULTI 3 controller now has an even lower profile. It therefore complies with the standard dimensions for T5 ECGs and is ideal for installation in ceilings. Remarkably unobtrusive. The ceiling sensor in the MULTI 3 system has a diameter of only 50 mm and can be installed inconspicuously almost anywhere with no loss of functionality. Other light and presence sensors are available to extend the system. Simple setup. The system can be installed very quickly and is immediately ready for use. Versatile modular system. With only a few components you can create solutions with MULTI 3 for luminaire groups and strip lighting in open-plan offices. 13 MULTI 3 DALI® MULTI 3. DIM MULTI 3. • Up to 70 %* energy savings compared with conventional solutions • Choice of 10 different operating modes • Up to 70 %* energy savings compared with conventional solutions • Choice of 10 different operating modes DALI® MULTI 3 DIM MULTI 3 1…10 V Up to 32 ECGs Up to 4 sensors Up to 32 ECGs Up to 4 sensors Connectable sensors (see also page 10) LS/PD MULTI 3 FL LS/PD MULTI 3 LS/PD MULTI 3 B LS/PD MULTI 3 CI LS/PD MULTI 3 A LS/PD MULTI 3 A-W * Compared to conventional systems: T8 lamp, conventional control gear, no sensors 14 DALI® MULTI 3 in strip lights. DALI® MULTI 3 in open-plan offices. Thanks to its modular design, DALI® MULTI 3 can also be used in large areas, such as group and open-plan offices. Up to four lighting groups can be synchronized with one another, so that up to 16 light and presence sensors can capture a larger area. Just like the smaller solutions for individual offices, this entire light management system can be unobtrusively integrated into the existing architecture of the room. Up to 4 sensors Up to 32 DALI® ECGs Up to 4 sensors Up to 32 DALI® ECGs Up to 4 sensors Up to 32 DALI® ECGs Up to 4 DALI® MULTI 3 controllers o can be synchronized for centralized presence detection Up to 4 sensors Up to 32 DALI® ECGs Up to 4 sensors Up to 32 DALI® ECGs Up to 4 sensors Up to 32 DALI® ECGs Intelligent energy-efficient luminaires and luminaire groups. Daylight-dependent control combined with a presence function can also be provided for strip lights. DALI® MULTI 3 allows new freedom in luminaire design: with their minimal dimensions, the sensors are easy to integrate while retaining maximum functionality. The sensors can simply be connected in parallel to enlarge the area. Strip light 1 Strip light 2 Strip light 3 Products: • DALI® MULTI 3 controller • QTi DALI® ECG • LS/PD MULTI 3 A-W luminaire installation sensor • Optional: Y-connector Group A Group B Group C Products: • DALI® MULTI 3 controller • LMS CI BOX ceiling installation box • LS/PD MULTI 3 CI ceiling installation sensor • Y-connector 15 MULTI 3 PRODUCT OVERVIEW DALI® MULTI 3 controller. DIM MULTI 3 controller. • Controller for up to 32 DALI® ECGs for daylightdependent control with presence function • Different operating modes depending on the application • 21 mm height for simple installation in luminaires; ceiling installation with LMS CI Box • Sensor connection via modular 4p4c socket • Up to 70 %* energy savings • Controller for up to 32 DALI® 1…10-V ECGs for daylight-dependent control with presence function • Different operating modes depending on the application • 21 mm height for simple installation in luminaires; ceiling installation with LMS CI Box • Sensor connection via modular 4p4c socket • Up to 70 %* energy savings Y-CONNECTOR. Y-CONNECTOR SCREW – Y-Connector with screw terminals. • Y-connector for system expansion with 2 ready-made modular 4p4c cables (2 m) • Allows the detection range to be expanded by connecting additional sensors • Allows synchronization of multiple MULTI 3 or MULTIeco controllers for central presence detection • 2 ready-made modular 4p4c cables (2 m) included LMS CI BOX – Ceiling installation box for controller. • LMS CI Box for ceiling mounting of the radio receiver and also for MULTI 3 controllers SENSOR KIT – Adapter for surface mounting. • Adapter for surface mounting the EASY IR CI receiver element * Compared to conventional systems: T8 lamp, conventional control gear, no sensors 16 MULTI 3 SYSTEM OVERVIEW MULTI 3 Standard switch User interface Sensors Controller / Receiver LS/PD MULTI 3 LS/PD MULTI 3 FL LS/PD MULTI 3 B LS/PD MULTI 3 CI LS/PD MULTI 3 A DALI® MULTI 3 LS/PD MULTI 3 A-W DIM MULTI 3 ECG / Ballast 1...10 V DIM HTi DALI® OTi DALI® 75 QTi DIM HT 1…10 V * OT DIM Light sources QTi DALI® * Suitable power supply required 17 STAND-ALONE SENSORS Stand-alone sensors for autonomous use as starting point for energy-saving lighting. Thanks to their ease of installation, stand-alone sensors offer especially cost-effective energy saving solutions and are ideal for retrofitting. Modern, easy-to-install sensors for a wide variety of applications OSRAM offers a large number of innovative sensors for indoor and outdoor use. They provide the basis for energy savings of up to 70 %* and are particularly easy to install or retrofit. * Compared to conventional systems: T8 lamp, conventional control gear, no sensors 18 • • • • • • • • • Offices: single and group workplaces Waiting rooms and conference rooms Hallways and foyers Stairwells Retail and commercial areas Restrooms and washrooms Factories and warehouses Single luminaires Strip lighting STAND-ALONE SENSORS PRODUCT OVERVIEW Light and presence sensors. SOLAR light and presence sensor. DUO light and presence sensor. • Suitable for such areas as hallways, waiting rooms, and wash rooms • Choice of different operating modes: daylight detection only, presence detection only, daylight and presence detection • All the functions can be selected on the rotary switch on the front of the casing and DIP switches in the casing • Minimal installation costs due to surface mounting or simple clip-on installation for T5 (diameter 16 mm) or T8 (diameter 26 mm) fluorescent lamps • Up to 30 ECGs can be connected • Adjustable switch-off delay: 1 min to 60 min • Standby consumption: max. 0.7 W • Load capacity of switching contact: 5 A ohmic load • Multiple sensors can be networked • Approx. 110° detection angle, detection area: max. diameter 12 m, max. installation height 5 m • Potential energy savings of up to 45 %* DIM MULTI light and presence sensor. • Suitable for such areas as individual and group offices • 1…10-V sensor for daylight-dependent and presence-dependent control • For ceiling surface mounting and simple clip-on installation for T5 (diameter 16 mm) or T8 (diameter 26 mm) fluorescent lamps • Choice of different operating modes: daylight detection only, daylight and presence detection • Approx. 110° detection angle, detection area: max. diameter 12 m, max. installation height 5 m • All the functions can be selected on the rotary switch and pushbutton on the front of the casing • Up to 30 ECGs can be connected • Adjustable switch-off delay: 1 to 30 min + 10 min switch-off time • Compensates for 100 % of the incoming daylight • Load capacity of switching contact: 5 A ohmic load • Multiple sensors can be networked • Potential energy savings of up to 70 %* * Compared to conventional systems: T8 lamp, conventional control gear, no sensors 19 STAND-ALONE SENSORS PRODUCT OVERVIEW Light and motion sensors. WALL SWITCH light and motion sensor with flush-mount relay insert. • Suitable for touch-free switching (e. g. hallways, stairwells) • Choice of different operating modes: stairwell, time switch, constant light • Can be combined with conventional light switches • Can be installed in standard wall flush-mount boxes • Manual constant light can be activated • Up to 14 ECGs can be connected • Delay time can be adjusted to any length up to 30 minutes • Multiple sensors can be networked • Approx. 180° detection angle, detection area max. diameter 8 m, max. installation height 2 m • Potential energy savings of up to 45 %* OUTDOOR light and motion sensor. • Suitable for outdoor applications • Choice of different operating modes: motion detection only, daylight and motion detection • Adjustable switch-off delay: 5 seconds to 30 minutes • Up to 14 ECGs can be connected • Manual control with optional switch or pushbutton • Swivel arm for wall or ceiling mounting • Approx. 120° detection angle, detection area max. diameter 16 m, max. installation height 4 m • Potential energy savings of up to 45 %* Light sensors. DIM PICO light sensor. • Suitable for individual luminaires in single and small group offices • 1…10-V mini light sensor for simple retrofitting • Direct connection to the 1…10-V interface • Simple clip-on installation for T5 (diameter 16 mm) or T8 (diameter 26 mm) fluorescent lamps • Simple setting of the set point using a potentiometer • Load capacity of the control output: max. 10 1…10-V ECGs or max. 6 mA • Cable length: 700 mm • Compensates for 50 % of the incoming daylight • Approx. 50° detection angle, max. installation height 5 m • Potential energy savings of up to 30 %* DIM MICO light sensor. • Suitable for strip lights in individual and group offices • 1…10-V mini light sensor for simple retrofitting • Direct connection to the 1…10-V interface • Simple clip-on installation for T5 (diameter 16 mm) or T8 (diameter 26 mm) fluorescent lamps • Simple setting of the set point using a potentiometer • Load capacity of the control output: max. 10 1…10-V ECGs or max. 16 signal amplifiers • Cable length: 700 mm • Compensates for 100 % of the incoming daylight • Approx. 80° detection angle, max. installation height 8 m • Potential energy savings of up to 40 %* Motion sensors. HIGH BAY motion sensor. • Suitable for great installation heights (factories, warehouses, sports facilities) • 3 m to 10 m: detection of motion by people • 3 m to 13 m: detection of vehicle movement (e.g. fork lift truck) • Adjustable switch-off delay: 30 seconds to 20 minutes • Surface mounting for low installation costs • Up to 15 ECGs can be connected • Standby consumption: max. 0.5 W • Can be surface-mounted on ceilings using a mounting adapter • Approx. 100° detection angle, detection area max. diameter 18 m, max. installation height 13 m • Potential energy savings of up to 35 %* VISION motion sensor. • Suitable for large areas, e. g. open-plan offices, hallways, and storage rooms • Adjustable switch-off delay: 30 seconds to 20 minutes • Surface mounting for low installation costs • Up to 15 ECGs can be connected • Standby consumption: max. 0.5 W • Can be surface-mounted on ceilings using a mounting adapter • Approx. 140° detection angle, detection area max. diameter 21 m, max. installation height 4.5 m • Potential energy savings of up to 35 %* * Compared to conventional systems: T8 lamp, conventional control gear, no sensors 21 STAND-ALONE SENSORS SYSTEM OVERVIEW Stand-alone sensors Sensors Sensors HIGH BAY WALL SWITCH VISION OUTDOOR DUO DIM MULTI DIM PICO DIM MICO Controller / Receiver User interface Switch 1...10 V DIM ECG / Ballast Switching contact * HTM® * OT ** QTi DIM HT 1…10 V OT DIM Light sources * QT 22 * Non-dimmable QT, HT, and OT electronic control gears ** Suitable power supply required ORDER OVERVIEW Touch DIM® Graphic Technical drawing h w l Order description Product number Dimensions Light and presence sensor, luminaire installation Touch DIM® LS/PD LI 4008321023025 63 × 29 × 21 mm (L × W × H) Light sensor, luminaire installation Touch DIM® LS LI 4008321023087 63 × 29 × 21 mm (L × W × H) Presence sensor TD PD LI 2P WOS 4008321532954 63 × 29 × 21 mm (L × W × H) Product description Order description Product number Dimensions Controller DALI® MULTIeco 4008321371300 118 × 30 × 21 mm (L × W × H) Controller MULTIeco 4008321405302 118 × 30 × 21 mm (L × W × H) Controller DIM MULTIeco 4008321507273 118 × 30 × 21 mm (L × W × H) Y-connector Y-CONNECTOR 4050300803135 34 × 18 × 16 mm (L × W × H) Y-connector incl. screw terminals Y-CONNECTOR SCREW 4008321916686 40 × 20 × 16 mm (L × W × H) Installation kit ECO CI KIT 4008321392091 ––––– Adapter for surface mounting SENSOR KIT 4008321916662 80 × 25 mm (Ø × H) h w l Product description MULTIeco Graphic Technical drawing w l h l w h l h w ––––– h Ø 23 ORDER OVERVIEW Sensors for MULTIeco /MULTI 3 Graphic Technical drawing l h w w l Order description Product number Dimensions Light and presence sensor, luminaire installation, standard LS/PD MULTI 3 4050300802138 55 × 21 × 25 mm (L × W × H) Light and presence sensor, luminaire installation, flat LS/PD MULTI 3 FL 4050300047342 35 × 21 × 12 mm (L × W × H) Light and presence sensor, luminaire installation, moveable LS/PD MULTI 3 B 4050300803081 48 × 30 × 25 mm (L × W × H) Light and presence sensor, ceiling installation, moveable LS/PD MULTI 3 CI 4008321916648 50 × 25 mm (Ø × H) Light and presence sensor, luminaire installation/ mounting LS/PD MULTI 3 A 4008321653598 38 × 20 × 22 mm (L × W × H) Light and presence sensor, luminaire installation/ mounting white LS/PD MULTI 3 A-W 4008321653611 38 × 20 × 22 mm (L × W × H) Product description Order description Product number Dimensions h Product description h w l ø h l h MULTI 3 Graphic Technical drawing ® Controller DALI MULTI 3 4050300802084 189 × 30 × 21 mm (L × W × H) Controller DIM MULTI 3 4050300802107 189 × 30 × 21 mm (L × W × H) Y-connector Y-CONNECTOR 4050300803135 34 × 18 × 16 mm (L × W × H) Y-connector incl. screw terminals Y-CONNECTOR SCREW 4008321916686 40 × 20 × 16 mm (L × W × H) Installation kit LMS CI BOX 4008321083692 261 × 71/35 × 27 mm (L × W × H) Adapter for surface mounting SENSOR KIT 4008321916662 80 × 25 mm (Ø × H) w l h l w h l h w w h l h Ø 24 ORDER OVERVIEW Stand-alone sensors Technical drawing Product description Order description Product number Dimensions Light and presence sensor SOLAR 4008321385628 108 × 108 × 26 mm (L × W × H) Light and presence sensor DUO 4008321496355 71 × 58 × 47 mm (L × W × H) Light and presence sensor DIM MULTI 4050300554471 58 × 71 × 48 mm (L × W × H) Light and motion sensor WALL SWITCH 4008321467386 82 × 82 × 26 mm (L × W × H) Light and motion sensor OUTDOOR 4008321957061 180 × 86 × 74 mm (L × W × H) Motion sensor HIGH BAY 4008321410078 116 × 116 × 39 mm (L × W × H) Motion sensor VISION 4008321957047 116 × 116 × 40 mm (L × W × H) Light sensor DIM PICO 4050300554457 21 × 21 × 31 mm (L × W × H) Light sensor DIM MICO 4050300464411 59 × 28 × 40 mm (L × W × H) 1-channel radio receiver SWITCH RC 4008321385642 45 × 37 × 23 mm (L × W × H) Adapter for surface mounting for HIGH BAY and VISION MOUNTING ADAPTER 4008321480798 116 × 19 mm (Ø × H) w w w h Graphic l w w l w h w w w 25 SYSTEM GUARANTEE / INFO System guarantee. Only from OSRAM: System+ Guarante ee for unique security and quality. OSRAM offers an extensive three-stage guarantee g for light man nagement systems and ECG/lamp systems from OSRAM. All the details on the relevant products, registration and the guarantee requirements can be fo ound at: www.osram.c com/system-guarantee Ambience ➔ EASY Color and white light control for shop and hospitality Scenes ➔ For multifunctional management of lighting groups and lighting scenes Components ➔ For expanding, connecting or installing light management products Light Source Control Gears ➔ For safe, efficient and reliable lamp/luminaire operation LMS from OSRAM: LMS folder. Compilation of product brochures on every LMS topic, including a poster, an application matrix and a CD-ROM, bundled in a folder. 1FZW001GB 10/11 VO OSRAM CRM M MK AB Energy saving ➔ For energy-saving daylight-dependent and presence-dependent lighting Subject to change without notice. OSRAM does not accept liability for errors, changes and omissions. The perfect solution: the OSRAM LMS product portfolio. To reflect the principal application requirements, OSRAM’s LMS product portfolio is structured in the following five categories: