OSRAM HALOTRONIC Manual

HALOTRONIC®
Electronic transformers for 12 V
halogen lamps
• Optimum lamp life
• Compact for small spaces
• Reversible switch off in case of shortcircuits, overload and overtemperature
• Dimming on the primary side is
possible. A corresponding dimmer
has to be used (suitable dimmers see
table)
Connecting the transformers to the
lamps
• Ensure that the lamp load is within the
output range of the transformers (see
table)
• Transformers can be connected in
parallel on the primary side (fig. 1a)
• Do not connect the transformers in
parallel or series on the secondary
side (fig. 1b)
• The maximum load of the transformer
can be connected to any of the lampside terminal pairs (except HTL 225)
• For units installed in fixtures the
luminaire manufacturer is responsible
for RFI-compliance
Wiring
• In accordance with the EN 60598
standard, the recommended
connecting cables (see table) must be
held firmly by the cable clamp to
prevent it from being pushed or pulled
• Secondary side: cable length maximum
2 m, minimum 0.3 m (fig. 2 and 3)
• To prevent radio interference keep lamp
cables as short as possible, keep them
away from metal surfaces and keep
them separated as far as possible from
mains cables (fig. 2 and 3: angles ≥ 90°).
Do not route cables along the
transformers
• When using single leads of a cable,
secondary wires have to be twisted
in pairs
Temperatures
• Avoid high temperatures. Do not place
the transformers close to the lamp
(minimum distance 0.3 m). Maximum
permissible ambient temperature must
not be exceeded (see table). Make sure
there is adequate space to avoid a
build-up of heat. In critical installations
the temperature at tc has to be
controlled
correct
Caution
• Transformers must be installed by a
qualified electrician
• Electronic transformers are not suitable
for any other load than low voltage
halogen lamps
• No switching or dimming on secondary
side
incorrect
1. a
1. b
HALOTRONIC
105 W
100 W
HALOTRONIC
105 W
120 W
HALOTRONIC
105 W
35 W
HALOTRONIC
105 W
10 W
HALOTRONIC
105 W
35 W
35 W
35 W
HALOTRONIC
105 W
HALOTRONIC
105 W
2.
3.
Optimum
area for
primary cable
max. 2 m
min. 0.3 m
90°
90°
Optimum
area for
primary cables
230 – 240 V
50 – 60 Hz
Prim.
Sec.
HTM 70
HTM 105
HTN 75
Optimum
area for
secondary
cables
mains
next
unit
max. 2 m
min. 0.3 m
HTL 105
HTL 225
HTM 150
Prim.
Sec.
Optimum
area for
secondary
cables
90°
4. Wire stripping (see table)
A
not used
B
HALOTRONIC®
C10238698 G10252879
HTM 70/230-240
HTM 105/230-240
Nominal line voltage:
230 V – 240 V
Operating voltage:
207 V – 254 V
HTM 150/230-240
207 V – 264 V
Safe operation:
Nominal line current:
0.27 Aeff
0.41 Aeff
Line frequency:
0.57 Aeff
50 – 60 Hz
Output voltage (230 V):
Losses:
Load range:
11.2 V (70 W); 11.2 V (20 W)
11.3 V (105 W); 11.4 V (35 W)
11.4 V (150 W); 11.5 V (50 W)
max. 4 W (70 W)
max. 6 W (105 W)
max. 7 W (150 W)
20 W – 70 W
35 W – 105 W
50 W – 150 W
Standards:
EN 55015; EN 61000-3-2; EN 61547; EN 61047; IEC 61347
Approvals:
Temperature range:
0 °C to +50 °C
Max. inrush current for cold lamps:
0.3 Aeff (70 W)
Dimming:
0 °C to +45 °C
1.0 Aeff (105 W)
Short circuit protection:
automat. switch off, reversible
Overload protection:
automat. switch off, reversible
Overheating protection:
automat. switch off, reversible
Suitable cable types for primary side:
NYM(3x1.5) mm2 ; H05VV-F(3x0.75 – 3x1.5) mm2
H05VV-F(2x0.75 – 2x1.5) mm2 ; H05VV-H2F(2x0.75 – 2x1.5) mm2
connection of 2 lines of the types
NYM 3x1.5; H05VV-F(3x1.5 – 3x1.0)
connection of 3 lines of the types NYM 3x1.5;
H05VV-F(2x1.5 – 2x0.75); H03VV-F(2x1.5 – 2x0.75)
Halogen low voltage line 2x1.5; 2x2.5:
cable sheath cross section (6x3.5) mm2 to (9x6) mm2
NYM(3x1.5) mm2
H05VV-F(3x0.75 – 3x1.5) mm2
H05VV-F(2x0.75 – 2x1.5) mm2
H05VVH2-F(2x0.75 – 2x1.5) mm2
cable sheath cross section (6x3.5) mm2 to (8x5) mm2
same cable type recommended as used at primary side
the sheath cross section must be equal to that of primary side
connection of 6 lines of the types H05VV-F2x0.75;
H03VV-F2x0.75 Halogen low voltage line 2x1.5:
cable sheath cross section (6x3.5) mm2 to (7x 5) mm2
A
12 mm
12 mm
B
7 mm
8 mm
Suitable cable types for secondary side:
Stripping lengths (fig. 4):
1.1 Aeff (150 W)
trailing or leading edge phase control for inductive load dimmers
HTN 75/230-240 I
HT 120/230-240/12 LF
HTL 105/230-240
HTL 225/230-240
230 V – 240 V
Nominal line voltage:
207 V – 254 V
Operating voltage:
207 V – 264 V
Safe operation:
Range of battery voltage for
emergency installation:
207 V – 264 VAC, 176 V – 275 VDC
–
Nominal line current:
Line frequency:
Output voltage (230 V):
Losses:
Load range:
176 V – 275 V
0.32 Aeff
0.48 Aeff
50 – 60 Hz
50 Hz
0.90 Aeff
0; 50 – 60 Hz
11.5 V (75 W),
11.7 V (20 W)
11.5 V (120 W),
11.5 V (35 W)
max. 4 W (75 W)
max. 6 W (120 W)
20 W – 75 W
35 W – 120 W
Standards:
0.44 Aeff
11.6 V (105 W),
11.3V (35 W)
11.6 V (225 W),
11.7 V (50 W)
max. 6 W (105 W)
max. 9 W (225 W)
35 W – 105 W
50 W – 225 W
EN 55015; EN 61000-3-2; EN 61547; EN 61047; IEC 61347
Approvals:
Temperature range:
0 °C to +50 °C
-20 °C to +45 °C
Max. inrush current for cold lamps:
0.37 Aeff (75 W)
2 Aeff (120 W)
Dimming:
trailing edge phase control
-20 °C to +50 °C
0.6 Aeff (105 W)
Short circuit protection:
automat. switch off, reversible
Overload protection:
automat. switch off, reversible
Overheating protection:
1.5 Aeff (225 W)
trailing or leading edge phase control
automat. switch off, reversible
Suitable cable types for primary side:
Suitable cable types for secondary side:
NYM(3x1.5) mm2
H05VV-F(2x0.75) mm2
H03VV-F(2x0.75) mm2
H03VVH2-F(2x0.75) mm2
H03VV-F2x0.50 mm2; H03VV-F2x0.75 mm2; H05VVH2-F2x0.75 mm2;
H03VVH2-F2x0.75 mm2; NYM-O 2x1.5 mm2; NYM-J 3x1.5 mm2; H05VV-F2x2.5 mm2
H03VV-F2x0.75 mm2; H05VVH2-F2x0.75 mm2; NYM-O 2x1.5 mm2;
H05VV-F2x1.5 mm2; H05VV-F2x2.5 mm2; NYM-J 3x1.5 mm2; NYM-J 3x2.5 mm2
A
10 mm
15 mm
14 mm
B
6 mm
7 mm
8 mm
Stripping lengths (fig. 4):
OSRAM GmbH
Steinerne Furt 62
86167 Augsburg, Germany
www.osram.com