www.osram.com POWERSTAR® HQI® Technical Information Contents. POWERSTAR® HQI®-T 3, 5 – 7 POWERSTAR HQI -T, BT 4 POWERSTAR® HQI®-TS Excellence 8 POWERSTAR® HQI®-TS 9 – 11 ® ® POWERSTAR HQI -E for open luminaires 12 – 14 POWERSTAR® HQI®-E/P for open luminaires 15 POWERSTAR® HQI®-E 16 – 17 Operating instructions 18 – 19 Lamp life/Operating characteristics in relation to the supply voltage 20 Start-up behaviour 21 ® ® Circuit diagrams/Burning positions/Base 22 Spectral power distribution of discharge lamps – POWERSTAR® 23 All rights reserved. No part of this document may be reproduced, copied or distributed in any form (printed matter, photocopy, etc.) without the written permission of OSRAM GmbH, Germany. This brochure supersedes all previous editions. All dimensions, weights, specifications and graphic representations are given without obligation. All design features, dimensions and technical specifications are subject to change without notice. POWERSTAR ® HQI®-T ® UV FILTER 1 Lamp reference HQI-T 70 W WDL HQI-T 70W/WDL HQI-T 70 W NDL HQI-T 70W/NDL HQI-T 150 W WDL HQI-T 150W/WDL HQI-T 150 W NDL HQI-T 150W/NDL Nominal luminous flux lm Luminous efficacy lm/W Light colour/Colour appearance Colour temperature K Colour rendering index Ra 5300 71 WDL 3000 76 5800 77 NDL 4200 84 13000 87 WDL 3000 77 13000 87 NDL 4200 85 Lamp wattage Lamp voltage Lamp current Ignition voltage min./max. 75 95 1 3.6/5 75 100 1 3.6/5 150 100 1.8 3.6/5 150 100 1.8 3.6/5 Base Diameter d mm Length max. I mm LCL a mm G12 25 84 56 G12 25 84 56 G12 25 84 56 G12 25 84 56 Burning position Average lamp life h Max. perm. outer bulb temp. °C Max. perm. pinch temp. °C PF corr. cap. at 50 Hz µF universal1) 9000 500 280 12 universal1) 9000 500 280 12 universal1) 9000 550 280 20 universal1) 9000 550 280 20 EAN Standard pack Qty Figure No. Circuit (see page 22) Fig. no. ILCOS 4050300412993 12 1 2/5 MT/UB-70/30/ 2A-H-G12-25/84 4050300488424 12 1 2/5 MT/UB-70/42/ 1B-H-G12-25/84 4050300873664 12 1 2/5 MT/UB-150/30/ 2A-H-G12-25/84 4050300488448 12 1 2/5 MT/UB-150/42/ 1B-H-G12-25/84 Survival rate HQI-T 70/WDL 80 60 40 20 0 0 1000 2000 3000 4000 5000 Hours burned 6000 7000 8000 Luminous flux in % 60 40 20 0 1000 2000 3000 4000 5000 Hours burned 6000 60 40 20 0 7000 8000 9000 1000 2000 3000 4000 5000 Hours burned 6000 7000 8000 9000 Luminous flux behaviour HQI-T 70/NDL, 150/WDL and 150/NDL 100 80 0 80 0 9000 Survival rate HQI-T 70/NDL, 150/WDL and 150/NDL 100 Luminous flux behaviour HQI-T 70/WDL 100 Luminous flux in % Survival rate in % 100 Survival rate in % W V A kVs 80 60 40 20 0 0 1000 1) For horizontal burning position, mount the holder in the manner that the lamp electrodes are arranged one on top of the other. 2000 3000 4000 5000 Hours burned 6000 7000 8000 9000 POWERSTAR ® HQI®-T, BT ® UV FILTER 1 2 Lamp reference HQI-T 250 W D HQI-T 250W/D HQI-BT 400 W D, NAV ballast HQI-BT 400W/D HQI-BT 400 W D, HQI ballast HQI-BT 400W/D HQI-T 400 W N, NAV ballast HQI-T 400W/N HQI-T 400 W N, HQI ballast HQI-T 400W/N Nominal luminous flux lm Luminous efficacy lm/W Light colour/Colour appearance Colour temperature K Colour rendering index Ra 20000 82 D 5200 90 35000 83 D 5200 90 27000 75 D 5900 90 42000 98 N 3500 65 34000 89 N 4000 > 60 Lamp wattage Lamp voltage Lamp current Nominal gear current Ignition voltage min./max. W V A A kVs 250 100 3 – 3/5 420 120 4 4.6 3/5 360 120 3.5 3.5 3/5 430 120 4.0 4.6 4/5 380 120 3.6 3.5 4/5 Base Diameter d mm Length max. I mm LCL a mm E40 46 225 150 E40 62 285 175 E40 62 285 175 E40 46 275 175 E40 46 275 175 Burning position Average lamp life h Max. perm. outer bulb temp. °C Max. perm. base edge temp. °C PF corr. cap. at 50 Hz µF universal 12000 500 250 32 universal 12000 500 250 45 universal 12000 500 250 35 p 45 12000 500 250 45 p 45 12000 500 250 35 EAN Standard pack Qty Figure No. Circuit (see page 22) Fig. no. ILCOS 4050300015293 12 1 2 MT/UB-250/52/ 1A-H-E40-46/225 4050300468471 12 2 2 MC/UB-400/52=59/ 1A-H-E40-62/285 4050300468471 12 2 2 MC/UB-400/52=59/ 1A-H-E40-62/285 4050300324647 12 1 2 MT/UB-400/35=40/ 2B-H-E40-46/275/P45 4050300324647 12 1 2 MT/UB-400/35=40/ 2B-H-E40-46/275/P45 Survival rate HQI-T 250/D 80 60 40 20 0 0 8000 10000 40 20 2000 4000 6000 Hours burned 8000 10000 Luminous flux in % 60 40 20 0 2000 4000 20 0 6000 Hours burned 8000 10000 12000 2000 4000 6000 Hours burned 8000 10000 12000 8000 10000 12000 8000 10000 12000 Luminous flux behaviour HQI-BT 400/D 80 60 40 20 0 2000 4000 6000 Hours burned Luminous flux behaviour HQI-T 400/N 100 80 0 40 0 12000 Survival rate HQI-T 400W/N 100 60 100 60 0 80 0 12000 Luminous flux in % Survival rate in % 6000 Hours burned 80 0 Survival rate in % 4000 Survival rate HQI-BT 400/D 100 2000 Luminous flux behaviour HQI-T 250/D 100 Luminous flux in % Survival rate in % 100 80 60 40 20 0 0 2000 4000 6000 Hours burned POWERSTAR ® HQI®-T ® UV FILTER 1 Lamp reference HQI-T 400 W BLUE HQI-T 400W BLUE HQI-T 400 W GREEN HQI-T 400W GREEN HQI-T 400 W MAGENTA HQI-T 400W MAGENTA Nominal luminous flux lm Luminous efficacy lm/W Light colour/Colour appearance Colour temperature K Colour rendering index Ra uncertain uncertain BLUE monochr. – uncertain uncertain GREEN monochr. – uncertain uncertain MAGENTA monochr. – Lamp wattage Lamp voltage Lamp current Nominal gear current Ignition voltage min./max. W V A A kVs 360 120 3.6 3.5 3/5 360 120 3.6 3.5 3/5 440 120 4.2 4.6 4/5 Base Diameter d mm Length max. I mm LCL a mm E40 46 275 175 E40 46 275 175 E40 46 275 175 Burning position Average lamp life h Max. perm. outer bulb temp. °C Max. perm. base edge temp. °C PF corr. cap. at 50 Hz µF p 55 6000 500 250 35 p 55 6000 500 250 35 p 55 6000 500 250 45 EAN Standard pack Qty Figure No. Circuit (see page 22) Fig. no. ILCOS 4050300575971 12 1 2 MT-400/BLUE/ H-E40-46/260/P55 4050300575957 12 1 2 MT-400/GREEN/ H-E40-46/260/P55 4050300649535 12 1 2 MT-400/MAGENTA/ H-E40-46/275/P55 POWERSTAR ® HQI®-T ® UV FILTER 1 2 HQI-T HQI-T HQI-T 1000 W 1000 W 2000 W D N D Lamp reference HQI-T HQI-T HQI-T 1000W/D 1000W/N 2000W/D HQI-T 2000 W N /E SUPER HQI-T 2000W/N/E SUPER HQI-T 2000 W N /SN SUPER HQI-T 2000W/N/SN SUPER Nominal luminous flux lm Luminous efficacy lm/W Light colour/Colour appearance Colour temperature K Colour rendering index Ra 85000 81 D 7250 90 110000 110 N 3500 65 180000 88 D 7250 90 240000 120 N 4400 65 240000 120 N 4400 65 Lamp wattage Mains voltage Lamp voltage Lamp current Nominal gear current Ignition voltage min./max. 1050 230 130 8.9 9.5 4/5 1000 230 125 9.1 9.5 4/5 2050 400 230 10.2 10.3 4/5 2000 400 220 9.4 8.8 4/5 2000 400 220 9.4 8.8 0.9/1.3 Base Diameter d mm Length max. I mm LCL a mm E40 76 345 220 E40 76 345 220 E40 100 430 265 E40 100 430 265 E40 100 430 265 Burning position Average lamp life h Max. perm. outer bulb temp. °C Max. perm. base edge temp. °C PF corr. cap. at 50 Hz µF p 30 9000 500 250 85 p 30 9000 500 250 85 p 30 9000 500 250 60 p 60 9000 500 250 37 p 60 9000 500 250 37 EAN Standard pack Qty Figure No. Circuit (see page 22) Fig. no. ILCOS 4050300015323 6 1 2 MT-1000/72/1A-H- E40-76/345/P30 4008321116604 6 1 2 MT-1000/35/2B-H- E40-76/345/P30 4050300015330 4 2 2 MT-2000/72/1A-E- E40-100/430/P30 4050300301860 4 2 2 MT-2000/44/2B-E- E40-100/430/P60 4050300348629 4 2 2 MT-2000/44/2B-EE40-100/430/P60 Survival rate HQI-T 1000W/D 80 60 40 20 0 0 3000 4000 5000 Hours burned 6000 7000 8000 60 40 20 0 1000 2000 3000 4000 5000 Hours burned 6000 7000 8000 Luminous flux in % 60 40 20 0 1000 2000 3000 20 0 4000 5000 Hours burned 6000 7000 8000 9000 1000 2000 3000 4000 5000 Hours burned 6000 7000 8000 9000 6000 7000 8000 9000 8000 9000 Luminous flux behaviour HQI-T 1000W/N 80 60 40 20 0 1000 2000 3000 4000 5000 Hours burned Luminous flux behaviour HQI-T 2000W/D, /N E, /N SN SUPER 100 80 0 40 0 9000 Survival rate HQI-T 2000W/D, /N E, /N SN SUPER 100 60 100 80 0 80 0 9000 Luminous flux in % Survival rate in % 2000 Survival rate HQI-T 1000W/N 100 Survival rate in % 1000 Luminous flux behaviour HQI-T 1000W/D 100 Luminous flux in % Survival rate in % 100 W V V A A kVs 80 60 40 20 0 0 1000 2000 3000 4000 5000 Hours burned 6000 7000 POWERSTAR ® HQI®-T ® UV FILTER 1 Lamp reference HQI-T 2000 W N 230 V HQI-T 2000W/N/230 V HQI-T 2000 W D /I HQI-T 2000W/D/I HQI-T 2000 W N integrated igniter HQI-T 2000W/N Nominal luminous flux lm Luminous efficacy lm/W Light colour/Colour appearance Colour temperature K Colour rendering index Ra 191000 98 N 4400 65 180000 88 D 7250 90 205000 103 D 4200 65 Lamp wattage Mains voltage Lamp voltage Lamp current Nominal gear current Ignition voltage min./max. 1950 230 120 19 2 x 8.25 0.7 2050 400 230 10.3 10.3 not reqd. 2000 400 230 9.0 8.8 not reqd. Base Diameter d mm Length max. I mm LCL a mm E40 100 430 265 E40 100 430 265 E40 100 430 265 Burning position Average lamp life h Max. perm. outer bulb temp. °C Max. perm. base edge temp. °C PF corr. cap. at 50 Hz µF p 30 9000 500 250 125 p 30 9000 500 250 60 p 60 9000 500 250 37 EAN Standard pack Qty Figure No. Circuit (see page 22) Fig. no. ILCOS 4050300421582 4 1 2 MT-2000/44/2B-E-E40-100/430/P30 4050300015446 4 1 1 MT-2000/72/1A-E/I-E40-100/430/P30 4050300015347 4 1 1 MT-2000/42/2B-E/I-E40-100/430/P60 Survival rate HQI-T 2000W/N 230V 80 60 40 20 0 0 2000 3000 4000 5000 Hours burned 6000 7000 8000 Luminous flux in % 60 40 20 0 1000 2000 3000 4000 5000 Hours burned 6000 7000 8000 Luminous flux in % 60 40 20 0 1000 2000 3000 4000 5000 Hours burned 20 0 6000 7000 8000 9000 1000 2000 3000 4000 5000 Hours burned 6000 7000 8000 9000 6000 7000 8000 9000 8000 9000 Luminous flux behaviour HQI-T 2000W/D/I 80 60 40 20 0 1000 2000 3000 4000 5000 Hours burned Luminous flux behaviour HQI-T 2000W N integrated igniter 100 80 0 40 0 9000 Survival rate HQI-T 2000W N integrated igniter 100 60 100 80 0 80 0 9000 Survival rate HQI-T 2000W/D/I 100 Survival rate in % 1000 Luminous flux behaviour HQI-T 2000W/N 230V 100 Luminous flux in % Survival rate in % 100 Survival rate in % W V V A A kVs 80 60 40 20 0 0 1000 2000 3000 4000 5000 Hours burned 6000 7000 POWERSTAR ® HQI®-TS Excellence1) ® UV FILTER 1 Lamp reference HQI-TS Excellence 70 W WDL HQI-TS 70W/WDL Exc HQI-TS Excellence 70 W NDL HQI-TS 70W/NDL Exc HQI-TS Excellence 70 W D HQI-TS 70W/D Exc HQI-TS Excellence 150 W WDL HQI-TS 150W/WDL Exc HQI-TS Excellence 150 W NDL HQI-TS 150W/NDL Exc HQI-TS Excellence 150 W D HQI-TS 150W/D Exc Nominal luminous flux lm Luminous efficacy lm/W Light colour/Colour appearance Colour temperature K Colour rendering index Ra 6200 80 WDL 3000 75 6500 83 NDL 4200 85 6200 80 D 5600 80 12000 80 WDL 3000 75 12500 83 NDL 4200 85 13500 90 D 5600 80 Lamp wattage Lamp voltage Lamp current Nominal gear current Ignition voltage min./max. W V A A kVs 78 100 1 1 3.6/5 78 100 1 1 3.6/5 78 100 1 1 3.6/5 150 95 1.8 1.8 3.6/5 150 95 1.8 1.8 3.6/5 150 100 1.8 1.8 3.6/5 Base Diameter d mm Length max. l mm LCL a mm RX7s 19 117 58.5 RX7s 19 117 58.5 RX7s 19 117 58.5 RX7s-24 23 135 67.5 RX7s-24 23 135 67.5 RX7s-24 23 135 67.5 Burning position Average lamp life h Max. perm. outer bulb temp. °C Max. perm. outer bulb border temp. °C PF corr. cap. at 50 Hz µF p 45 12000 500 350 12 p 45 12000 500 350 12 p 45 12000 500 350 12 p 45 12000 650 350 20 p 45 12000 650 350 20 p 45 12000 650 350 20 EAN Standard pack Qty Figure No. Circuit (see page 22) Fig. no. ILCOS 4008321149619 12 1 2/3/5 MD/UB-70/30/2A-H- RX7s/114.2/p45 4008321149596 12 1 2/3/5 MD/UB-70/42/1B-H- RX7s/114.2/p45 40083211495572 12 1 2/5 MD/UB-70/56/1B-H- RX7s/114.2/p45 4008321149695 4008321149671 4008321149657 12 12 12 1 1 1 2/3/5 2/3/5 2/5 MD/UB-150/30/2A-H- MD/UB-150/42/1B-H- MD/UB-150/52/1B-HRX7s=24/132/p45 RX7s=24/132/p45 RX7s=24/132/p45 Survival rate HQI-TS Excellence 70/WDL, /NDL, /D 80 60 40 20 0 0 8000 10000 40 20 2000 4000 6000 Hours burned 8000 10000 Luminous flux in % 60 40 20 0 2000 4000 6000 Hours burned 1) T he new HQI-TS Excellence replaces the previous HQI-TS. 20 0 8000 10000 12000 2000 4000 6000 Hours burned 8000 10000 12000 10000 12000 10000 12000 Luminous flux behaviour HQI-TS Excellence 150/WDL 80 60 40 20 0 2000 4000 6000 Hours burned 8000 Luminous flux behaviour HQI-TS Excellence 150/NDL, /D 100 80 0 40 0 12000 Survival rate HQI-TS Excellence 150/NDL, /D 100 60 100 60 0 80 0 12000 Luminous flux in % Survival rate in % 6000 Hours burned 80 0 Survival rate in % 4000 Survival rate HQI-TS Excellence 150/WDL 100 2000 Luminous flux behaviour HQI-TS Excellence 70/WDL, /NDL, /D 100 Luminous flux in % Survival rate in % 100 80 60 40 20 0 0 2000 4000 6000 Hours burned 8000 POWERSTAR ® HQI®-TS ® UV FILTER 1 2 Lamp reference HQI-TS 250 W WDL HQI-TS 250W/WDL HQI-TS 250 W NDL HQI-TS 250W/NDL HQI-TS 250 W D HQI-TS 250W/D HQI-TS 400 W NDL HQI-TS 400W/NDL HQI-TS 400 W D, NAV ballast HQI-TS 400W/D HQI-TS 400 W D, HQI ballast HQI-TS 400W/D Nominal luminous flux lm Luminous efficacy lm/W Light colour/Colour appearance Colour temperature K Colour rendering index Ra 22000 88 WDL 3200 80 20000 82 NDL 4200 88 20000 82 D 5100 93 38000 90 NDL 4200 88 37000 90 D 5200 93 31000 89 D 5600 90 Lamp wattage Lamp voltage Lamp current Ignition voltage min./max. W V A kVs 250 110 2.8 3.6/5 250 100 3 3.6/5 250 100 3 3/5 400 120 4.11) 3/5 400 125 4.1 3/5 350 120 3.6 3/5 Base Diameter d mm Length max. I mm LCL a mm Fc2 25 163 81.5 Fc2 25 163 81.5 Fc2 25 163 81.5 Fc2 31 206 103 Fc2 31 206 103 Fc2 31 206 103 Burning position Average lamp life h Max. perm. outer bulb temp. °C Max. perm. pinch temp. °C PF corr. cap. at 50 Hz µF p 45 12000 650 300 32 p 45 12000 650 300 32 p 45 12000 650 300 32 p 45 12000 650 300 45 p 45 12000 650 300 45 p 45 12000 650 300 35 EAN Standard pack Qty Figure No. Circuit (see page 22) Fig. no. ILCOS 4050300436012 12 1 2/3 MD/UB-250/32/1B- H-Fc2-25/163/P45 4050300436036 12 1 2/3 MD/UB-250/42/1B- H-Fc2-25/163/P45 4050300436050 12 1 2 MD/UB-250/51/1A- H-Fc2-25/163/P45 4050300304090 12 2 2/3 MD/UB-400/42/1B- H-Fc2-31/206/P45 4050300015385 4050300015385 12 12 2 2 2 2 MD/UB-400/52=56/ MD/UB-400/52=56/ 1A-H-Fc2-31/206/P451A-H-Fc2-31/206/P45 Survival rate HQI-TS 250/NDL, /D 80 60 40 20 0 0 6000 Hours burned 8000 10000 60 40 20 0 2000 4000 6000 Hours burned 8000 10000 Luminous flux in % 60 40 20 0 2000 1) Operate only with NAV control gear. 4000 20 0 6000 Hours burned 8000 10000 12000 2000 4000 6000 Hours burned 10000 12000 8000 10000 12000 8000 10000 12000 8000 Luminous flux behaviour HQI-TS 250/WDL, 400/NDL 80 60 40 20 0 2000 4000 6000 Hours burned Luminous flux behaviour HQI-TS 400/D 100 80 0 40 0 12000 Survival rate HQI-TS 400/D 100 60 100 80 0 80 0 12000 Luminous flux in % Survival rate in % 4000 Survival rate HQI-TS 250/WDL, 400/NDL 100 Survival rate in % 2000 Luminous flux behaviour HQI-TS 250/NDL, /D 100 Luminous flux in % Survival rate in % 100 80 60 40 20 0 0 2000 4000 6000 Hours burned POWERSTAR ® HQI®-TS l1 l1 1 2 Lamp reference HQI-TS 1000 W NDL /S HQI-TS 1000W/NDL/S HQI-TS 1000 W D /S HQI-TS 1000W/D/S HQI-TS 2000 W D /S HQI-TS 2000W/D/S HQI-TS 2000 W D /S High Flux HQI-TS 2000W/D/S High Flux Nominal luminous flux lm Luminous efficacy lm/W Light colour/Colour appearance Colour temperature K Colour rendering index Ra 90000 90 NDL 4400 > 85 90000 90 D 5900 90 200000 103 D 5900 90 220000 107 D 5900 90 Lamp wattage Mains voltage Lamp voltage Lamp current Nominal gear current Hot restrike Ignition voltage min./max. W V V A A kVs kVs 1000 230 125 9.2 9.5 36 4/5 1000 230 120 9.4 9.5 36 4/5 1950 400 200 11.5 10.3 36 4/5 2060 400 200 12.2 12.2 36 4/5 Base Diameter d mm Insertion length l1 max. mm Length max. I mm Total length min. mm LCL a mm cable 36 157 187 285 93 cable 36 157 187 285 93 cable 36 157 187 285 93 cable 36 157 187 285 93 Burning position Average lamp life h Max. perm. outer bulb temp. °C °C Max. perm. pinch temp. PF corr. cap. at 50 Hz µF ACGIH UV output mW/lm² · 1000 lx p 15 6000 950 390 85 < 34 p 15/s 15 6000 950 390 85 < 92 p 15 4000 950 390 60 < 33 p 15 2500 950 390 70 < 75 EAN Standard pack Qty Figure No. Circuit (see page 22) Fig. no. ILCOS 4050300349916 10 1 2/3 MN-1000/44/1B-H- cable lug-36/187/P15 4050300300092 10 1 2/3 MN-1000/59/1A-H- cable lug-36/187/P15/S15 4050300271682 10 2 2/4 MN-2000/59/1A-E- cable lug-36/187/P15 4008321338310 10 2 2/4 MN-2000/59/1A-Ecable lug-36/187/P15 Survival rate HQI-TS 1000W NDL S 80 60 40 20 0 0 4000 5000 40 20 1000 2000 3000 Hours burned 4000 5000 Luminous flux in % 60 40 20 0 1000 2000 Hours burned 20 0 3000 4000 1000 2000 3000 Hours burned 4000 5000 6000 4000 5000 6000 Luminous flux behaviour HQI-TS 1000W D S 80 60 40 20 0 1000 2000 3000 Hours burned Luminous flux behaviour HQI-TS 2000W D S 100 80 0 40 0 6000 Survival rate HQI-TS 2000W D S 100 60 100 60 0 80 0 6000 Luminous flux in % Survival rate in % 3000 Hours burned 80 0 Survival rate in % 2000 Survival rate HQI-TS 1000W D S 100 10 1000 Luminous flux behaviour HQI-TS 1000W NDL S 100 Luminous flux in % Survival rate in % 100 80 60 40 20 0 0 1000 2000 Hours burned 3000 4000 POWERSTAR ® HQI®-TS l1 l1 1 2 Lamp reference HQI-TS 2000 W NDL /S HQI-TS 2000W/NDL/S HQI-TS 2000 W N /L HQI-TS 2000W/N/L HQI-TS 2000 W D /L HQI-TS 2000W/D/L Nominal luminous flux lm Luminous efficacy lm/W Light colour/Colour appearance Colour temperature K Colour rendering index Ra 215000 110 NDL 4400 > 85 230000 107 N 4200 > 65 205000 95 D 5400 > 85 Lamp wattage Mains voltage Lamp voltage Lamp current Nominal gear current Hot restrike Ignition voltage min./max. W V V A A kVs kVs 1950 400 205 11.3 10.3 36 4/5 2150 400 225 10.7 10.3 – 4/5 2150 400 240 9.7 10.3 36 4/5 Base Diameter d mm Insertion length l1 max. mm Length max. I mm Total length min. mm LCL a mm cable 36 157 187 285 93 cable 32 244 274 374 137 cable 32 244 274 374 137 Burning position p 15 Average lamp life h 5000 Max. perm. outer bulb temp. °C 950 °C 390 Max. perm. pinch temp. PF corr. cap. at 50 Hz µF 60 ACGIH UV output mW/lm² · 1000 lx p 15 8000 950 390 60 < 148 p 15 8000 950 390 60 EAN Standard pack Qty Figure No. Circuit (see page 22) Fig. no. ILCOS 4050300607344 10 2 2/4 MN-2000/42/2B-E- cable lug-36/274/P15 4008321931825 10 2 2/4 MN-2000/54/1B-Ecable lug-36/274/P15 Survival rate HQI-TS 2000W NDL S 80 60 40 20 0 0 2000 3000 Hours burned 4000 Luminous flux in % 60 40 20 0 1000 2000 3000 4000 5000 Hours burned 6000 7000 Luminous flux in % 60 40 20 0 1000 2000 3000 4000 5000 Hours burned 20 0 6000 7000 8000 1) L amps to be operated in axially symmetrical luminaires only where the lamp is situated along the axis. 1000 2000 3000 Hours burned 4000 5000 Luminous flux behaviour HQI-TS 2000W N L 80 60 40 20 0 1000 2000 3000 4000 5000 Hours burned 6000 7000 8000 6000 7000 8000 Luminous flux behaviour HQI-TS 2000W D L 100 80 0 40 0 8000 Survival rate HQI-TS 2000W D L 100 60 100 80 0 80 0 5000 Survival rate HQI-TS 2000W N L 100 Survival rate in % 1000 Luminous flux behaviour HQI-TS 2000W NDL S 100 Luminous flux in % Survival rate in % 100 Survival rate in % 4008321910196 10 1 2/4 MN-2000/44/1B-E- cable lug-36/187/P15 80 60 40 20 0 0 1000 2000 3000 4000 5000 Hours burned 11 POWERSTAR ® HQI®-E for open luminaires ® UV FILTER 1 2 Lamp reference HQI-E 70 W WDL clear for open luminaires HQI-E 70W/WDL clear HQI-E 70 W WDL coated for open luminaires HQI-E 70W/WDL coated HQI-E 70 W NDL clear for open luminaires HQI-E 70W/NDL clear HQI-E 70 W NDL coated for open luminaires HQI-E 70W/NDL coated Nominal luminous flux lm Luminous efficacy lm/W Light colour/Colour appearance Colour temperature K Colour rendering index Ra 5200 71 WDL 3000 70 4700 64 WDL 2900 70 5500 75 NDL 4200 80 5100 70 NDL 4000 80 Lamp wattage Lamp voltage Lamp current Ignition voltage min./max. 73 95 0.95 3.6/5 73 95 0.95 3.6/5 73 95 1 3.6/5 73 95 1 3.6/5 Base Diameter d mm Length max. I mm LCL a mm E27 55 144 92 E27 55 144 – E27 55 144 92 E27 55 144 – Burning position Average lamp life h Max. perm. outer bulb temp. °C Max. perm. base edge temp. °C PF corr. cap. at 50 Hz µF universal 9000 330 210 12 universal 9000 330 210 12 universal 6000 330 210 12 universal 6000 330 210 12 EAN Standard pack Qty Figure No. Circuit (see page 22) Fig. no. ILCOS 4050300397788 20 1 2/5 MCS/UB-70/30/ 2A-H-E27-55/144 4050300397801 20 2 2/5 MES/UB-70/29/ 2A-H-E27-55/144 4050300397825 20 1 2/5 MCS/UB-70/42/ 1B-H-E27-55/144 4050300397849 20 2 2/5 MES/UB-70/40/ 1B-H-E27-55/144 Survival rate HQI-E 70/WDL 80 60 40 20 0 0 2000 3000 4000 5000 Hours burned 6000 7000 8000 Luminous flux in % 60 40 20 0 1000 2000 60 40 20 0 3000 Hours burned 4000 5000 6000 1000 2000 3000 4000 5000 Hours burned 6000 7000 8000 9000 Luminous flux behaviour HQI-E 70/NDL 100 80 0 80 0 9000 Survival rate HQI-E 70/NDL 100 Survival rate in % 1000 Luminous flux behaviour HQI-E 70/WDL 100 Luminous flux in % Survival rate in % 100 12 W V A kVs 80 60 40 20 0 0 1000 2000 3000 Hours burned 4000 5000 6000 POWERSTAR ® HQI®-E for open luminaires ® UV FILTER 1 2 Lamp reference HQI-E 100 W WDL clear for open luminaires HQI-E 100W/WDL clear HQI-E 100 W WDL coated for open luminaires HQI-E 100W/WDL coated HQI-E 100 W NDL clear for open luminaires HQI-E 100W/NDL clear HQI-E 100 W NDL coated for open luminaires HQI-E 100W/NDL coated Nominal luminous flux lm Luminous efficacy lm/W Light colour/Colour appearance Colour temperature K Colour rendering index Ra 8500 85 WDL 3000 70 7900 79 WDL 2900 70 8400 84 NDL 4200 85 7700 77 NDL 4000 85 Lamp wattage Lamp voltage Lamp current Ignition voltage min./max. 100 95 1.1 3.6/5 100 95 1.1 3.6/5 100 95 1.1 3.6/5 100 95 1.1 3.6/5 Base Diameter d mm Length max. I mm LCL a mm E27 55 144 92 E27 55 144 – E27 55 144 92 E27 55 144 – Burning position Average lamp life h Max. perm. outer bulb temp. °C Max. perm. base edge temp. °C PF corr. cap. at 50 Hz µF universal 9000 330 210 16 universal 9000 330 210 16 universal 6000 330 210 16 universal 6000 330 210 16 EAN Standard pack Qty Figure No. Circuit (see page 22) Fig. no. ILCOS 4050300351537 20 1 2 MCS/UB-100/30/ 2A-H-E27-55/144 4050300351551 20 2 2 MES/UB-100/29/ 2A-H-E27-55/144 4050300345871 20 1 2 MCS/UB-100/42/ 1B-H-E27-55/144 4050300345833 20 2 2 MES/UB-100/40/ 1B-H-E27-55/144 Survival rate HQI-E 100/WDL 80 60 40 20 0 0 1000 2000 3000 4000 5000 Hours burned 6000 7000 8000 Luminous flux in % 60 40 20 0 1000 2000 60 40 20 0 3000 Hours burned 4000 5000 6000 1000 2000 3000 4000 5000 Hours burned 6000 7000 8000 9000 Luminous flux behaviour HQI-E 100/NDL 100 80 0 80 0 9000 Survival rate HQI-E 100/NDL 100 Luminous flux behaviour HQI-E 100/WDL 100 Luminous flux in % Survival rate in % 100 Survival rate in % W V A kVs 80 60 40 20 0 0 1000 2000 3000 Hours burned 4000 5000 6000 13 POWERSTAR ® HQI®-E for open luminaires ® UV FILTER 1 2 Lamp reference HQI-E 150 W WDL clear for open luminaires HQI-E 150W/WDL clear HQI-E 150 W WDL coated for open luminaires HQI-E 150W/WDL coated HQI-E 150 W NDL clear for open luminaires HQI-E 150W/NDL clear HQI-E 150 W NDL coated for open luminaires HQI-E 150W/NDL coated Nominal luminous flux lm Luminous efficacy lm/W Light colour/Colour appearance Colour temperature K Colour rendering index Ra 12900 86 WDL 3000 70 11600 77 WDL 2900 70 12500 83 NDL 4200 83 11500 77 NDL 4000 86 Lamp wattage Lamp voltage Lamp current Ignition voltage min./max. 150 95 1.8 3.6/5 150 95 1.8 3.6/5 150 85 1.8 3.6/5 150 85 1.8 3.6/5 Base Diameter d mm Length max. I mm LCL a mm E27 55 144 92 E27 55 144 – E27 55 144 92 E27 55 144 – Burning position Average lamp life h Max. perm. outer bulb temp. °C Max. perm. base edge temp. °C PF corr. cap. at 50 Hz µF universal 9000 330 210 20 universal 9000 330 210 20 universal 6000 330 210 20 universal 6000 330 210 20 EAN Standard pack Qty Figure No. Circuit (see page 22) Fig. no. ILCOS 4050300433974 20 1 2/5 MCS/UB-150/30/ 2A-H-E27-55/144 4050300433998 20 2 2/5 MES/UB-150/29/ 2A-H-E27-55/144 4050300434018 20 1 2/5 MCS/UB-150/42/ 1B-H-E27-55/144 4050300434032 20 2 2/5 MES/UB-150/40/ 1B-H-E27-55/144 Survival rate HQI-E 150/WDL 80 60 40 20 0 0 2000 3000 4000 5000 Hours burned 6000 7000 8000 Luminous flux in % 60 40 20 0 1000 2000 60 40 20 0 3000 Hours burned 4000 5000 6000 1000 2000 3000 4000 5000 Hours burned 6000 7000 8000 9000 Luminous flux behaviour HQI-E 150/NDL 100 80 0 80 0 9000 Survival rate HQI-E 150/NDL 100 Survival rate in % 1000 Luminous flux behaviour HQI-E 150/WDL 100 Luminous flux in % Survival rate in % 100 14 W V A kVs 80 60 40 20 0 0 1000 2000 3000 Hours burned 4000 5000 6000 POWERSTAR ® HQI®-E/P for open luminaires ® UV FILTER 1 Lamp reference HQI-E/P 250 W D coated for open luminaires HQI-E/P 250W/D HQI-E/P 400 W D coated for open luminaires, NAV ballast HQI-E/P 400W/D HQI-E/P 400 W D coated for open luminaires, HQI ballast HQI-E/P 400W/D Nominal luminous flux lm Luminous efficacy lm/W Light colour/Colour appearance Colour temperature K Colour rendering index Ra 17000 71 D 5200 90 31000 76 D 4700 90 25000 71 D 5200 90 Lamp wattage Lamp voltage Lamp current Ignition voltage min./max. W V A kVs 250 100 3 3/5 430 110 3.8 3/5 380 115 3.5 3/5 Base Diameter d mm Length max. I mm LCL a mm E40 90 226 – E40 120 290 – E40 120 290 – Burning position Average lamp life h Max. perm. outer bulb temp. °C Max. perm. base edge temp. °C PF corr. cap. at 50 Hz µF universal 6000 400 250 32 universal 12000 400 250 45 universal 12000 400 250 35 EAN Standard pack Qty Figure No. Circuit (see page 22) Fig. no. ILCOS 4050300637457 12 1 2 MES/UB-250/52/1A-H-E40-90/226 4050300637433 12 1 2 MES/UB-400/47=52/1A-H-E40-120/290 4050300637433 12 1 2 MES/UB-400/47=52/1A-H-E40-120/290 Survival rate HQI-EP 400/D 80 60 40 20 0 0 2000 4000 Luminous flux behaviour HQI-EP 400/D 100 Luminous flux in % Survival rate in % 100 6000 Hours burned 8000 10000 12000 80 60 40 20 0 0 2000 4000 6000 Hours burned 8000 10000 12000 15 POWERSTAR ® HQI®-E ® UV FILTER 1 Lamp reference HQI-E 250 W D coated HQI-E 250W/D HQI-E 400 W D coated, NAV ballast HQI-E 400W/D HQI-E 400 W D coated, HQI ballast HQI-E 400W/D Nominal luminous flux lm Luminous efficacy lm/W Light colour/Colour appearance Colour temperature K Colour rendering index Ra 19000 78 D 5200 90 34000 81 D 5300 90 26000 72 D 5500 90 460 130 3.8 4.6 3/5 400 110 3.6 3.5 3/5 Lamp wattage Lamp voltage Lamp current Nominal gear current Ignition voltage min./max. Base Diameter d mm Length max. I mm LCL a mm E40 90 226 – E40 120 290 – E40 120 290 – Burning position Average lamp life h Max. perm. outer bulb temp. °C Max. perm. base edge temp. °C PF corr. cap. at 50 Hz µF universal 12000 400 250 32 universal 12000 400 250 45 universal 12000 400 250 35 EAN Standard pack Qty Figure No. Circuit (see page 22) Fig. no. ILCOS 4050300015248 12 1 2 ME/UB-250/52/ 1A-H-E40-90/226 4050300019727 12 1 2 ME/UB-400/53=55/ 1A-H-E40-120/290 4050300019727 12 1 2 ME/UB-400/53=55/ 1A-H-E40-120/290 Survival rate HQI-E 250/D 80 60 40 20 0 0 4000 6000 Hours burned 8000 10000 Luminous flux in % 60 40 20 0 2000 4000 60 40 20 0 6000 Hours burned 8000 10000 12000 2000 4000 6000 Hours burned 8000 10000 12000 8000 10000 12000 Luminous flux behaviour HQI-E 400/D 100 80 0 80 0 12000 Survival rate HQI-E 400/D 100 Survival rate in % 2000 Luminous flux behaviour HQI-E 250/D 100 Luminous flux in % Survival rate in % 100 16 W 250 V 100 A 3 A kVs 3/5 80 60 40 20 0 0 2000 4000 6000 Hours burned POWERSTAR ® HQI®-E ® UV FILTER 1 2 Lamp reference HQI-E 400 W N clear, NAV ballast HQI-E 400W/N clear HQI-E 400 W N clear, HQI ballast HQI-E 400W/N clear HQI-E 400 W N coated, NAV ballast HQI-E 400W/N HQI-E 400 W N coated, HQI ballast HQI-E 400W/N HQI-E 1000 W N coated HQI-E 1000W/N Nominal luminous flux lm Luminous efficacy lm/W Light colour/Colour appearance Colour temperature K Colour rendering index Ra 42000 95 N 4000 65 34000 90 N 4600 65 40000 91 N 3800 65 34000 90 N 4400 65 100000 95 N 3800 65 Lamp wattage Lamp voltage Lamp current Nominal gear current Ignition voltage min./max. W V A A kVs 440 120 4 4.6 4/5 380 120 3.4 3.5 4/5 440 120 4 4.6 4/5 380 120 3.4 3.5 4/5 1050 125 9.5 9.5 4/5 Base Diameter d mm Length max. I mm LCL a mm E40 120 285 198 E40 120 285 198 E40 120 285 – E40 120 285 – E40 165 380 – Burning position Average lamp life h Max. perm. outer bulb temp. °C Max. perm. base edge temp. °C PF corr. cap. at 50 Hz µF h45 12000 500 250 45 h45 12000 500 250 35 h45 12000 500 250 45 h45 12000 500 250 35 h 45 9000 400 250 85 EAN Standard pack Qty Figure No. Circuit (see page 22) Fig. no. ILCOS 4050300292632 4050300292632 4050300305431 4050300305431 4050300015279 12 12 12 12 6 1 1 2 2 2 2 2 2 2 2 MC/UB-400/40=46/ MC/UB-400/40=46/ ME/UB-400/38=44/ ME/UB-400/38=44/ ME-1000/38/ 2B-H-E40-120/285/H452B-H-E40-120/285/H452B-H-E40-120/285/H452B-H-E40-120/285/H452B-H-E40-165/380/H45 Survival rate HQI-E 400W/N 80 60 40 20 0 0 4000 6000 Hours burned 8000 10000 Luminous flux in % 60 40 20 0 1000 2000 3000 60 40 20 0 4000 5000 Hours burned 6000 7000 8000 9000 2000 4000 6000 Hours burned 8000 10000 12000 Luminous flux behaviour HQI-E 1000W/N 100 80 0 80 0 12000 Survival rate HQI-E 1000W/N 100 Survival rate in % 2000 Luminous flux behaviour HQI-E 400W/N 100 Luminous flux in % Survival rate in % 100 80 60 40 20 0 0 1000 2000 3000 4000 5000 Hours burned 6000 7000 8000 9000 17 Please note: The values and curves published in this document are for guidance only. The basic data was determined under controlled laboratory conditions for a switching cycle of 11 h on/1 h off. There may be considerable differences in actual practice. PF correction capacitor: The pf correction capacitors are designed so that cos w > 0.9 is achieved at rated voltage. Operating instructions Supply voltage: The lamps must be connected via suitable control gear. A 240 V / 50 Hz ac supply is generally required. If a different supply voltage is used (e.g. 400 V / 50 Hz) control gear with appropriate taps must be used. Permitted mains voltage deviation: ± 3% Sudden fluctuations in mains voltage of more than 10% may cause the lamps to go out. If the deviation from rated supply voltage (230 V or 400 V) is permanent, high-pressure discharge lamps may exhibit changes in colour or luminous flux. Lamp life may also be reduced. High-pressure discharge lamps should therefore only be operated with control gear with thermal protection. This applies also to control gear with the option of power reduction. The following lamps with integrated igniters don’t need external igniter: c HQI®-T 2000 /D/I c HQI®-T 2000 /N The lamps must not be operated with integrated igniters in luminaires equipped with igniters. Suitable igniters and control gear for POWERSTAR ® are available from the electrical industry. Operation of HQI-TS Excellence at PT-TS ballast – which are not produced or sold anymore for very long time – is not permitted. Control gear: Conventional control gear: Choke, igniter and pf correction capacitor. The right igniter for the particular lamp type must be used to ensure reliable and safe ignition. Igniters must always be installed close to the lamp. The choke may be installed any distance from the lamp, provided the permissible voltage drop is not exceeded. For power supplies with a neutral conductor the choke should be connected to the live conductor. In the case of luminaires in which there are no lamps installed, the ignition equipment (igniter, ignition pulser) must be disabled when voltage is applied otherwise the igniters may produce radio interference. The chokes and pf correction capacitors generally needed for operating discharge lamps may, under certain conditions, create oscillating circuits. These circuits may then produce excessive currents and voltages, which in turn can destroy the lamps, ballasts and capacitors. Such resonance phenomena must be avoided by appropriate circuits and fuses. When high-pressure discharge lamps come to the end of their lives a rectifier effect may occur (see IEC 62035). This is not manufacturer-specific. Because of the excessive dc current components the ballasts and igniters may become overheated. 18 Operating temperatures: Only high-pressure discharge lamps with external igniters are suitable for low-temperature applications down to – 50 °C. Such applications call for special (heatable) igniters such as MZN 400 SU-LT from BAG Turgi (for lamps from 100 to 400 W). Power factor: CCG: Because of the series connected choke this is around 0.5 to 0.7 (without compensation) ECG: If POWERTRONIC ® is used the power factor is greater than 0.96. Compensation is therefore not needed here. Switching on: Full luminous flux is reached only a few minutes after the lamp is switched on. The start-up current may be up to twice the operating current depending on the control gear. (See also the graphs on p. 21) Fusing: Guarantee: HQI® lamps must be protected by slow acting fuses. If fuse wire is used it is sufficient for it to be rated at twice the rated current of the lamp. If automatic cutouts are used they should have characteristic “C”. If adjusted to the upper limit value of 10 x rated current there will be no triggering if fuse protection is at twice the rated lamp current. A guarantee can only made if suitable control gear is used and the defined operating conditions are met. Restarting: The lamps will restart only after they have cooled down for 2 to 15 minutes. Instant restarting with suitable igniters is possible for: c HQI-TS < 400 W c HQI-TS 1000 W/D/S and 2000 W/D/S (short arc) c HQI-TS 2000 W/D/L (long arc) The necessary surge voltage is 25 to 60 kVs. Lampholders: Because of the high voltages involved in ignition the lampholders must be designed for these high voltages. Lampholders that meet these requirements are available from appropriate manufacturers. Power reduction: Dimming metal halide lamps is not recommended. OSRAM cannot provide a guarantee for dimmed lamps. Dimming adversely affects colour rendering. The colour location shifts towards colder light colours and the colour spread increases. Dimmed lamps also tend to flicker. Luminous flux maintenance is significantly worse as a result of dimming. Dimming can shorten the life of the lamps. End of life: To protect the control gear and to avoid radio interference, high-pressure discharge lamps must be replaced as soon as they come to the end of their life. These lamps reach their end of life when c the light colour of the lamp changes dramatically c there is a significant loss of brightness c the lamp no longer ignites c the lamp starts to cycle (periodically goes out and ignites again). At end of lamp life the risk of a broken burner rises. This phenomena is caused by effects not dependent on the manufacturer like the rectifying effect mentioned earlier. Because of this we strongly recommend to change the lamp latest after average lifetime has been reached or if one of the above mentioned effects are shown. Safety: OSRAM high-pressure lamps meet the safety requirements defined in IEC 62035. All HQI lamps with outer bulb are of UV reduced design and comply with necessary limits (ACGIH < 2 mW/1000 Im). Because of their high operating pressure all HQI-lamps may only be used in fully enclosed luminaires designed to take them: c All HQI®-TS c All HQI®-T c All HQI®-E > 250 W As we cannot completely rule out the possibility of the bulb bursting, luminaires for the lamps mentioned above must be equipped with sealed shatter-proof shields that can withstand wide fluctuations in temperature. Operating lamps with a damaged outer bulb is dangerous and therefore not permitted. Exception: HQI®-TS ... without an outer bulb. Lamp operation: Operating high-pressure lamps for short periods in combination with frequent on/off switching will shorten their life. This applies to both cold starting and hot restarts. The lamps should be operated for at least 3 hours and should remain off for at least 30 minutes. This applies in particular to HQI® = 1000 W. Exceptions: The following lamps are suitable for open luminaires: c All HQI®-E 70 W to 150 W c All HQI®-E/P The use of shields should be considered for safety reasons in each case. Luminaire design: Luminaire design (thermal design and fuse protection) should be based on the EN 60598-1 standard. HQI® 1000 W to 2000 W lamps should be held without pressure or by means of a lamp support close to the base-free end. Notes on disposal: All metal halide lamps contain small quantities of mercury. If they break, poisonous mercury vapour may be released. The lamps must be treated as waste requiring special supervision with EEC code 20 01 21* for waste or residue containing mercury and should be passed to a relevant collection or recycling company. 19 Photometric and electrical data: All lamp-specific electrical and photometric data is measured after 100 hours of operation under laboratory conditions on reference equipment. Unless otherwise indicated, the data relates to the horizontal burning position for T and TS types and to the base up burning position for E types. If different burning positions are used in actual practice there may be considerable changes in the lamp data, particularly with regard to luminous flux, colour temperature and lamp life. The luminous flux is virtually unaffected by the ambient temperature outside the luminaire. At low ambient temperatures down to around – 50 °C special igniters are needed. Detailed information on heat accumulation tubes (luminaire simulators) for determining lamp data for HQI®-TS and HCI®-TS is given in IEC 61167, clause 1.7. Colour deviations: With all metal halide lamps there may be differences in colour from one lamp to the next due to external factors such as mains voltage, type of control gear used, burning position and luminaire design. Lamp life There are a confusing number of definitions for lamp life, and these differ from one region to the next and from one application to the next. The basic definitions for the most common types are given below. Minimum life: Minimum period of time in which a lamp remains in operation under laboratory conditions. This document refers explicitly only to the average life. Economical life: Average life: Average number of hours burned over several groups in which in the group in question half the lamps have failed as the result of a defect (50% failure). Period of time between group relamping of an installation under the condition that operating costs are minimised and the installation luminous flux does not fall below a particular value. This will vary according to the application. Survival rate: Service life: Quantity of working lamps of a group of lamps after a defined number of burning hours. Average value of some groups. Simplified practical view of the economical life. This is the operating time after which the installation luminous flux (the product of the relative luminous flux and the lamps still in operation) is still around 70% (sometimes 80%). Operating characteristics in relation to the supply voltage POWERSTAR HQI-T < 150 W POWERSTAR, other versions 130 % 120 130 % 120 110 110 100 PL UL IL Φ UL Φ 0 0 0 PL 0 95 100 105 % 110 Mains voltage 20 IL 90 90 90 100 Φ = Luminous flux PL = Lamp wattage IL = Lamp current UL = Lamp voltage 90 95 100 105 % 110 Mains voltage = Not permitted Start-up behaviour (average value) 10 10 160 160 140 140 120 120 100 100 Rel. operating values POWERSTAR HQI-T < 150 W Rel. operating values POWERSTAR HQI-T < 150 W with POWERTRONIC 0 60 40 20 0 1 IL 0 PL 60 UL 40 20 Φ 0 2 3 min 4 Start-up time 1 2 3 min 4 Start-up time POWERSTAR HQI-TS 0 W…1000 W with CCG POWERSTAR Neutral White 1000 W and 2000 W with CCG 10 10 160 160 140 140 IL 100 100 Rel. operating values % 120 Rel. operating values % 120 0 60 PL 40 20 UL 0 Φ 1 2 3 min 4 Start-up time IL PL UL 0 60 40 20 Φ 0 1 2 3 min 4 Start-up time POWERSTAR Daylight 2000 W with CCG 10 160 IL 140 120 Rel. operating values % 100 PL UL 0 60 40 Φ 20 0 1 2 3 min 4 Start-up time 21 Circuit diagrams D ZS L LH UN K F POWERTRONIC PTi (all) N LL LH 2 1 B =6 A fuse, slow acting D = Choke F = Protection on demand K = PF correction capacitor K+S= Time-limiting switch and contactor L = Lamp L H = High-voltage terminal Mp = Neutral conductor Sch = Switch 3 4 U N = 2 30 V ac mains voltage (for 2000 W = 400 V ac) Z = Igniter to be installed near the lamp ZL = HF igniter lead to contact plate of lamp ZS = Symmetrical hot restrike ignitor with automatic ignition 5 For power supplies with a neutral conductor the choke should be connected to the live conductor. The right igniter for the particular lamp type must be used to ensure reliable and safe ignition. Chokes, holder, capacitors and igniters are available from electrical suppliers. Burning positions s5 Permitted Not permitted Base 8.5 G22 IEC 004-5 22 LH G 8.5 Spectral power distribution of discharge lamps POWERSTAR ® HQI® .../WDL HQI® .../NDL HQI® .../N HQI® .../D Visible range from 380 to 780 nm Vertical scale 400 mW 1000 lm · 10 nm 23 www.osram.com Global presence. Support for around 150 countries. • 78 companies and sales offices for 113 countries • 37 countries served by local agents or OSRAM GmbH, Munich Albania Argentina Australia Austria Azerbaijan Belarus Benelux Bosnia-Herzegovina Brazil Bulgaria Canada Chile China Columbia Croatia Czech Republic Denmark Ecuador Egypt Estonia Finland France Georgia Great Britain Greece Hong Kong Hungary India Indonesia Iran Italy Japan Kazakhstan Kenya OSRAM GmbH Head Office Hellabrunner Strasse 1 81543 Munich Germany Phone +49 (0) 89-6213-0 Fax +49 (0) 89-6213-20 20 www.osram.com Korea Latvia Lithuania Macedonia Malaysia Mexico Moldavia Norway Pakistan Peru Philippines Poland Portugal Rumania Russia Saudi Arabia Serbia-Montenegro Singapore Slovakia Slovenia South Africa Spain Sweden Switzerland Taiwan Thailand Tunisia Turkey Ukraine United Arab Emirates USA Uzbekistan Venezuela Vietnam 106T001GB 04/09 OSRAM CRM CC Subject to change without notice. Errors and omission excepted. OSRAM associated companies and support centers.