SAW Components SAW Duplexer LTE Band II (PCS) Series/type: Ordering code: B8618 B39202B8618P810 Date: Version: January 22, 2015 2.0 © EPCOS AG 2015. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. EPCOS AG is a TDK Group Company. SAW Components B8618 SAW Duplexer 1880.0 / 1960.0 MHz Data sheet Application ■ Low-loss SAW duplexer for mobile telephone LTE Band II (PCS) systems Low insertion attenuation Low amplitude ripple Usable passband 60 MHz Single ended to balanced transformation in Antenna - Rx path ■ Impedance transformation 50Ω to 100Ω in Antenna - Rx path ■ ■ ■ ■ 0.3 ■ Package size 1.8 x 1.4 mm2, 1 0.7 max. height 0.5 mm ■ RoHS compatible ■ Approx. weight 0.0035 g ■ Package for Surface Mount Technology 3 4 8 7 0.5 max. (SMT) ■ Ni, gold-plated terminals ■ Electrostatic Sensitive Device (ESD) ■ Moisture Sensitive Level 3 (MSL) 0.35 2 6 5 0.25 0.25 Features bottom view 0.5 max side view 1.8 1.4 7 6 8 4 1 2 Pin configuration ■ ■ ■ ■ 1, 8 3 6 2, 4, 5, 7 RX Output, balanced TX Input, single ended Antenna Ground Please read cautions and warnings and important notes at the end of this document. 2 5 January 22, 2015 3 top view SAW Components B8618 SAW Duplexer 1880.0 / 1960.0 MHz Data sheet Characteristics Temperature range for specification: T TX terminating impedance: ANT terminating impedance: RX terminating impedance: RX terminating impedance: ZTX = 50 Ω ZANT = 50 Ω ZRX = 100 Ω || 9.5 nH (differential mode) ZRX = 25 Ω (common mode) = –30 ˚C to +85 ˚C Characteristics TX - ANT — B86181) typ. @ 25˚C 1880 — min. Center frequency fC Maximum insertion attenuation 1850.24 ...1909.76 MHz Amplitude variation (over any 5 MHz) 1850.24 ...1909.76 MHz Error Vector Magnitude @fCarrier 1852.4 ...1907.6 MHz EVM 2) Input VSWR (TX port) 1850.24 ...1909.76 MHz Output VSWR (ANT port) 1850.24 ...1909.76 MHz max. — MHz 1.9 2.5 dB — 0.3 1.5 dB — 0.5 3.0 % — 1.4 2.0 — 1.4 2.0 30 40 40 43 43 30 44 20 44 25 26 21 23 42 43 43 50 54 54 57 52 49 35 29 29 27 — — — — — — — — — — — — — Attenuation 50.0 728.0 869.0 1226.0 1559.0 1605.9 1930.24 2010.0 2110.0 2400.0 3700.0 4900.0 5550.0 1) 2) ... 787.0 MHz ... 764.0 MHz ... 894.0 MHz ... 1250.0 MHz ... 1606.0 MHz ... 1680.0 MHz ...1989.76 MHz ... 2025.0 MHz ... 2155.0 MHz ... 2500.0 MHz ... 3820.0 MHz ... 5950.0 MHz ... 5730.0 MHz dB dB dB dB dB dB dB dB dB dB dB dB dB Specified min./max. values are valid for a testing power of +10 dBm. Error Vector Magnitude (based on definition given in 3GPP TS 25.141) of a 3.84 Mcps WCDMA signal. Please read cautions and warnings and important notes at the end of this document. 3 January 22, 2015 SAW Components B8618 SAW Duplexer 1880.0 / 1960.0 MHz Data sheet Characteristics Temperature range for specification: T TX terminating impedance: ANT terminating impedance: RX terminating impedance: RX terminating impedance: ZTX = 50 Ω ZANT = 50 Ω ZRX = 100 Ω || 9.5 nH (differential mode) ZRX = 25 Ω (common mode) = –30 ˚C to +85 ˚C — B86181) typ. @ 25˚C 1960 Maximum insertion attenuation 1930.24 ...1989.76 MHz — Input VSWR (ANT port) 1930.24 ...1989.76 MHz Characteristics ANT - RX Center frequency min. fC Output VSWR (RX port) 1930.24 ...1989.76 MHz Attenuation — MHz 2.7 3.5 dB — 1.6 2.0 — 1.6 2.0 45 50 45 25 30 20 40 48 49 >60 52 39 37 31 51 52 — — — — — — — — α 50.0 ... 1850.0 MHz 80.0 MHz 1850.24 ...1909.76 MHz 2050.0 ... 2075.0 MHz 2075.0 ... 2350.0 MHz 2350.0 ... 2550.0 MHz 2550.0 ... 6000.0 MHz 5610.0 ... 5845.0 MHz 1) max. Specified min./max. values are valid for a testing power of +10 dBm. Please read cautions and warnings and important notes at the end of this document. 4 January 22, 2015 dB dB dB dB dB dB dB dB SAW Components B8618 SAW Duplexer 1880.0 / 1960.0 MHz Data sheet Characteristics Temperature range for specification: T TX terminating impedance: ANT terminating impedance: RX terminating impedance: RX terminating impedance: ZTX = 50 Ω ZANT = 50 Ω ZRX = 100 Ω || 9.5 nH (differential mode) ZRX = 25 Ω (common mode) = –30 ˚C to +85 ˚C Characteristics ANT - RX Differential Mode Isolation α 1574.0 ... 1577.0 MHz 1850.24 ...1909.76 MHz 1930.24 ...1989.76 MHz 3700.0 ... 3820.0 MHz 5550.0 ... 5850.0 MHz Common Mode Isolation α 1850.24 ... 1909.76 MHz 1) min. B86181) typ. @ 25˚C max. 40 54 67 57 — — dB dB 55 20 20 61 58 49 — — — dB dB dB 43 48 — dB Specified min./max. values are valid for a testing power of +10 dBm. Please read cautions and warnings and important notes at the end of this document. 5 January 22, 2015 SAW Components B8618 SAW Duplexer 1880.0 / 1960.0 MHz Data sheet Maximum ratings Operable temperature range Storage temperature range DC voltage ESD voltage ESD voltage Input power at 1850.24 ... 1909.76 MHz elsewhere T Tstg VDC VESD VESD PIN –30/+90 –40/+90 0 3001) 6002) 29 10 ˚C ˚C V V V dBm dBm human body model, 1 pulse charged device model, 3 pulses source and load impedance 50 Ω continuous wave T = 50˚C, >5.000 h } 1) target, acc. to JESD22-A114F (human body model), 1 negative & 1 positive pulses. 2) target, acc. to JESD22-C101C (charge device model), 3 negative & 3 positive pulses. Please read cautions and warnings and important notes at the end of this document. 6 January 22, 2015 SAW Components B8618 SAW Duplexer 1880.0 / 1960.0 MHz Data sheet Frequency response TX - ANT (passband) Frequency response TX - ANT Please read cautions and warnings and important notes at the end of this document. 7 January 22, 2015 SAW Components B8618 SAW Duplexer 1880.0 / 1960.0 MHz Data sheet Frequency response TX - ANT (wideband) Frequency response ANT - RX (passband) Please read cautions and warnings and important notes at the end of this document. 8 January 22, 2015 SAW Components B8618 SAW Duplexer 1880.0 / 1960.0 MHz Data sheet Frequency response ANT - RX Frequency response ANT - RX (wideband) Please read cautions and warnings and important notes at the end of this document. 9 January 22, 2015 SAW Components B8618 SAW Duplexer 1880.0 / 1960.0 MHz Data sheet Frequency response TX - RX differential mode isolation Please read cautions and warnings and important notes at the end of this document. 10 January 22, 2015 SAW Components B8618 SAW Duplexer 1880.0 / 1960.0 MHz Data sheet VSWR S11 TX-port VSWR S33 RX-port VSWR S22 ANT-port Please read cautions and warnings and important notes at the end of this document. 11 January 22, 2015 SAW Components B8618 SAW Duplexer 1880.0 / 1960.0 MHz Data sheet References Type B8618 Ordering code B39202-B8618-P810 Marking and package C61157-A8-A87 Packaging F61074-V8259-Z000 Date codes L_1126 B8618_NB_UN.s3p (unmatched, narrow band) S-parameters B8618_WB_UN.s3p (unmatched, wide band) see file header for port/pin assignment table Soldering profile S_6001 RoHS compatible RoHS-compatible means that products are compatible with the requirements according to Art. 4 (substance restrictions) of Directive 2011/65/EU of the European Parliament and of the Council of June 8th, 2011, on the restriction of the use of certain hazardous substances in electrical and electronic equipment ("Directive") with due regard to the application of exemptions as per Annex III of the Directive in certain cases. For further information please contact your local EPCOS sales office or visit our webpage at www.epcos.com . Published by EPCOS AG Systems, Acoustics, Waves Business Group P.O. Box 80 17 09, 81617 Munich, GERMANY EPCOS AG 2014. This brochure replaces the previous edition. For questions on technology, prices and delivery please contact the Sales Offices of EPCOS AG or the international Representatives. Due to technical requirements components may contain dangerous substances. For information on the type in question please also contact one of our Sales Offices. Please read cautions and warnings and important notes at the end of this document. 12 January 22, 2015 Important notes The following applies to all products named in this publication: 1. 2. 3. 4. 5. 6. 7. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. We also point out that in individual cases, a malfunction of electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of an electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of an electronic component. The warnings, cautions and product-specific notes must be observed. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. The aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the “General Terms of Delivery for Products and Services in the Electrical Industry” published by the German Electrical and Electronics Industry Association (ZVEI). The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CeraLink, CeraPlas, CSMP, CSSP, CTVS, DeltaCap, DigiSiMic, DSSP, FilterCap, FormFit, MiniBlue, MiniCell, MKD, MKK, MLSC, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SiMic, SIMID, SineFormer, SIOV, SIP5D, SIP5K, TFAP, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks. 13 January 22, 2015