CHS-MSS

Humidity Sensor Units
Unit type
CHS series
Type:
CHS-U (For industrial use and measuring equipment)
CHS-SS(For consumer and office equipment)
CHS-C(For consumer and office equipment)
Issue date:
January 2010
• All specifications are subject to change without notice.
• Conformity to RoHS Directive: This means that, in conformity with EU Directive 2002/95/EC, lead, cadmium, mercury, hexavalent chromium, and specific
bromine-based flame retardants, PBB and PBDE, have not been used, except for exempted applications.
(1/6)
Humidity Sensor Units
CHS Series CHS-U, -SS, -C Types
TDK’s CHS series humidity sensors are compact and extremely
simple to apply. Because they contain the necessary circuitry,
there is no need to provide additional control circuitry or perform
time-consuming calibration. With simple connection to a power
supply, they will output DC at 100% relative humidity. This makes it
possible to read RH directly with a voltmeter.
CHS-U TYPE
For industrial use and measuring equipment
FEATURES
• These sensors can measure a wide range of humidity – from
5(%) to 95(%)RH.
• They are highly accurate. The nominal accuracy for the CHSUPR and CHR-UPS is within ±3(%) RH.
CHS-UGS
CHS-UGR
±5
5 to 95
Type
Nominal accuracy(%)RH
Measuring range(%)RH
CHS-UPS
CHS-UPR
±3
5 to 95
SHAPES AND DIMENSIONS
SQUARE TYPE
CHS-UGS, -UPS
• Characteristics are stable over a wide temperature range.
• Humidity sensing characteristics exhibit virtually no hysteresis.
• Highly cost-effective and compact, requiring extremely little
mounting space.
• Low current consumption.
• Outputs DC.1V at 100(%)RH; relative humidity can be read
directly with a voltmeter.
• All-in-one construction integrates sensor with support circuitry.
The entire module operates off a 5V power supply.
• Generated ripple at low humidity levels will not exceed 2.5mV.
ROUND TYPE
CHS-UGR, -UPR
20max.
6.5max.
11.5max.
Sensible
side ∗
27max.
Sensible
side ∗
Sensible
side ∗
9max.
Label
0.49
0.49
5.7±0.5
1 2 3
(3.8)
Pin No. 1 Analog output voltage
Pin No. 2 GND
Pin No. 3 +Power supply voltage
2.5
5
5
Pin No. 1 Analog output voltage
Pin No. 2 GND
Pin No. 3 +Power supply voltage
Label
1
Weight: 1.38g typ.
3
5
2.5
5±0.5
Label
2
MAXIMUM RATINGS (Ta=25°C)
Power supply voltage Edc
Operating conditions
Storage conditions
7V max.
0 to +50°C, power supply voltage 5V, without
dewing
–20 to +60°C, without dewing
∗ When installing the device, ensure that the humidity
sensing surface is not obstructed.
Weight: 1.68g typ.
Dimensions in mm
Tolerance: ±0.2
• All specifications are subject to change without notice.
002-01 / 20100120 / eb111_chs.fm
(2/6)
CHS-U TYPE
ELECTRICAL CHARACTERISTICS
Item
Operating voltage Edc (V)
Operating current(mA)
Output voltage(mV)/(%)RH
Output impedance(kΩ )
Accuracy(%)RH
CHS-UPS, -UPR
CHS-UGS, -UGR
Hysteresis(%)RH
Temperature dependency(%)RH
Response time(min)
Recommended operating temperature(°C)
∗(
Specifications
Minimum
Standard
4.75
5
Conditions
Maximum
5.25
0.6
Edc=5V, 25°C
Edc=5V, 25°C, 5 to 95(%)RH
at DC
Edc=5V, 25°C, 5 to 95(%)RH
(For details, please refer to typical characteristics)
Stable time: 20min
Edc=5V, 25°C standard, +5 to +45°C, 5 to 95(%)RH
Response time to reach 90% of actual humidity as for from 30 to
85(%)RH
Edc=5V
10
(200)∗
–3
–5
+3
+5
≈0
–5
+5
1
+5
+45
): Reference value
TYPICAL CHARACTERISTICS
SENSOR LINEARITY CHARACTERISTICS (Ta=25°C Edc=5V)
TEMPERATURE DEPENDENCY CHARACTERISTICS
1
1
95(%)RH
90(%)RH
0.8
(+3(%)RH) +5(%)RH
0.6
0.4
–5(%)RH (–3(%)RH)
0.2
Output voltage (V)
Output voltage (V)
0.8
0.6
80(%)RH
70(%)RH
60(%)RH
50(%)RH
40(%)RH
0.4
30(%)RH
20(%)RH
0.2
10(%)RH
5(%)RH
0
0
20
40
60
80
100
Relative humidity (%)RH
Center line
Tolerance of each humidity
Allowance
UP TYPE ±3(%)RH
Typical value
UG TYPE ±5(%)RH
0
0
10
20
30
40
50
Temperature (˚C)
Typical value
Specification temperature zone
+5 to +45˚C (5 to 95(%)RH)
Tolerance of each humidity
±5(%)RH
• All specifications are subject to change without notice.
002-01 / 20100120 / eb111_chs.fm
(3/6)
CHS-SS TYPE
For consumer and office equipment
Type
Nominal accuracy(%)RH
Measuring range(%)RH
10max.
5max.
Sensible
side∗1
CHS
Label
Vout G+5
(7)
7V max.
0.5
1 2 3
0 to +50°C, power supply voltage 5V, without dewing
∗2
–20 to +60°C, without dewing
2.5
Sensible
side∗1
SS
R
CHS-MSS
±5
20 to 85
MAXIMUM RATINGS (Ta=25°C)
Power supply
voltage Edc
Operating
conditions
Storage
conditions
SHAPES AND DIMENSIONS
SQUARE TYPE
20max.
FEATURES
• Humidity sensing characteristics exhibit virtually no hysteresis.
• Compact size.
• Low current consumption.
• Outputs DC.1V at 100(%)RH; relative humidity can be read
directly with a voltmeter.
• All-in-one construction integrates sensor with support circuitry.
The entire module operates off a 5V power supply.
• Generated ripple at low humidity levels will not exceed 2.5mV.
2.5
0.25
Pin No. 1 Analog output voltage
Pin No. 2 GND
Pin No. 3 +Power supply voltage
∗1 When installing the device, ensure that the humidity
sensing surface is not obstructed.
∗2 The three leads are parallel to within 0.2mm.
Weight: 1.1g typ.
Dimensions in mm
Tolerance: ±0.2
ELECTRICAL CHARACTERISTICS
Item
Operating voltage Edc (V)
Operating current(mA)
Output voltage(mV)/(%)RH
Output impedance(kΩ )
Accuracy(%)RH
Hysteresis(%)RH
Temperature dependency(%)RH
Response time(min)
Recommended operating
temperature(°C)
∗(
Specifications
Minimum
Standard
4.75
5
Conditions
Maximum
5.25
0.6
10
(200)∗
–5
+5
≈0
–5
+5
1
+15
+35
Edc=5V, 25°C
Edc=5V, 25°C
at DC
Edc=5V, 25°C, 20 to 85(%)RH(For details, please refer to typical
characteristics)
Stable time: 20min
Edc=5V, 25°C standard
Response time to reach 90% of actual humidity as for from 30 to 85(%)RH
Edc=5V, without dewing(For details, please refer to typical characteristics)
): Reference value
• All specifications are subject to change without notice.
002-01 / 20100120 / eb111_chs.fm
(4/6)
CHS-SS TYPE
TYPICAL CHARACTERISTICS
SENSOR LINEARITY CHARACTERISTICS (Ta=25°C Edc=5V)
CHS-MSS TYPE
TEMPERATURE DEPENDENCY CHARACTERISTICS
CHS-MSS TYPE
1
1
95(%)RH
+5(%)RH
Output voltage (V)
Output voltage (V)
90(%)RH
80(%)RH
70(%)RH
60(%)RH
0.8
0.8
0.6
0.4
–5(%)RH
0.2
0.6
50(%)RH
40(%)RH
0.4
30(%)RH
20(%)RH
0.2
10(%)RH
5(%)RH
0
0
20
40
60
80
Relative humidity (%)RH
Center line
Allowance
Typical value
100
0
0
10
20
30
40
50
Temperature (˚C)
±5 (%) RH specification temperature zone
Not specification temperature zone
• All specifications are subject to change without notice.
002-01 / 20100120 / eb111_chs.fm
(5/6)
CHS-C TYPE
For consumer and office equipment
34
7.0
Storage conditions
5.5
Pin No. 1 +5V
Pin No. 2 Humidity output
(RHV)
Pin No. 3 GND•TH1
Pin No. 4 TH2
4
3
2
1
(7)
(5)
2-ø4.1±0.1
Humidity sensor
Components mounting region
15max.
7V max.
0 to +50°C, power supply voltage 5V, without
dewing
–20 to +60°C, without dewing
1.5
Operating conditions
Connector
17
CHS-CMC-_ _
±5
30, 50, 80
MAXIMUM RATINGS (Ta=25°C)
Power supply voltage Edc
20
4max.
Type
Nominal accuracy(%)RH
Measuring range(%)RH
SHAPES AND DIMENSIONS
28
FEATURES
• Temperature detection thermistor can be added.
• Humidity sensing characteristics exhibit virtually no hysteresis.
• Low current consumption.
• Absolute humidity can be read directly with DC. 1V voltmeter.
• All-in-one construction incorporates circuits and 5V power
supply operation.
• Generated ripple at low humidity levels will not exceed 2.5mV.
Dimensions in mm
Tolerance: ±0.5
ELECTRICAL CHARACTERISTICS
Item
Specifications
Minimum
4.75
Operating voltage Edc (V)
Operating current(mA)
Output impedance(kΩ )
Maximum
5.25
0.6
(200)
30(%)RH
Accuracy(%)RH
Conditions
Standard
5
50(%)RH
80(%)RH
–5
(0.5V)
–5
(0.86V)
–5
(1.5V)
(1.6V)
–5
+5
Response time(min)
Recommended operating
temperature(°C)
(0.96V)
+5
(0.7V)
+5
(1.06V)
+5
(1.7V)
≈0
Hysteresis(%)RH
Temperature dependency(%)RH
(0.6V)
1
+15
+35
Edc=5V, 25°C
at DC
Edc=5V, 25°C
(For details, please refer to typical characteristics)
Stable time: 20 min
Edc=5V, 25°C standard
(For details, please refer to typical characteristics)
Response time to reach 90% of actual humidity as for from
30 to 85(%)RH
Edc=5V
RECOMMENDED CHARACTERISTICS OF TEMPERATURE
DETECTION THERMISTOR
Part No.
Resistance value(Between TH1 and TH2)
Constant B
Maximum rated power
NTCCM16084BH103JC
10kΩ ±5%
4100K±3%
230mW
• All specifications are subject to change without notice.
002-01 / 20100120 / eb111_chs.fm
(6/6)
TEMPERATURE DEPENDENCY CHARACTERISTICS
2
2
1.6
1.6
Output voltage (V)
Output voltage (V)
CHS-C TYPE
TYPICAL CHARACTERISTICS
SENSOR LINEARITY CHARACTERISTICS(Ta=25°C, Edc=5V)
1.2
0.8
0.4
0
1.2
0.8
0.4
0
0
0
20
40
60
80
100
Relative humidity (%)RH
Typical value
Specification temperatue zone
TYPICAL APPLICATIONS
HUMIDITY MONITOR
10
20
30
40
50
Temperature (˚C)
±5 (%) RH specification temperature zone
Not specification temperature zone
BATTERY POWERED SYSTEM
+5V
3
2
1
3
2
1.5V×4
Humidity
output signal
1
10µF
Humidity
output signal
• All specifications are subject to change without notice.
002-01 / 20100120 / eb111_chs.fm