SCL P - SCM Ni-Cd single cells Capacity: 10 Ah to 70 Ah

SCL P - SCM Ni-Cd single cells
Capacity: 10 Ah to 70 Ah
Nickel-cadmium single cells are
designed for general purpose
applications, where maximum
operating reliability is a key
factor:
• switch tripping
• emergency lighting
• alarms
• DC instrumentation
SCL P cells are designed for long
discharge periods, typically
2 hours and longer.
SCM cells are designed for
medium discharge periods
between 30 minutes and
3 hours.
Benefits
■
■
They provide a long service life,
minor maintenance
requirements, outstanding
resistance to electrical and
mechanical abuse, excellent
charge retention, a long shelf
life and long operation over a
wide temperature range.
Translucent polypropylene
containers allow visibility of the
electrolyte level, hence
facilitating maintenance in
stationary applications.
March 2006
■
The junction between the lid and
the container is thermo-welded,
ensuring good mechanical and
electrical resistance.
■
Flip top vents assure an easy
maintenance.
■
The products are qualified
according IEC 60623.
Mechanical characterictics
Capacity
Cell
C5 A
type
(Ah)
Electrolyte
Approx. weight
reserve
per cell
(cm3)
(in3)
Dimensions (mm)
Height (H)
Width (W)
Length (L1)
kg
lbs.
mm
in
mm
in
mm
in
Terminal
SCL 10 P
10
80
4.88
0.9
1.9
177
6.97
122.5
4.83
35.5
1.40
M6
SCL 20 P
20
80
4.88
1.1
2.4
177
6.97
122.5
4.83
35.5
1.40
M6
SCL 30 P
30
165
10.1
1.8
4.0
237
9.34
122.5
4.83
44.5
1.75
M6
SCL 40 P
40
165
10.1
1.9
4.1
237
9.34
122.5
4.83
44.5
1.75
M6
SCL 55 P
55
195
14.0
2.8
6.1
291
11.5
122.5
4.83
54.5
2.15
M 10
SCL 70 P
70
195
14.0
3.1
6.8
291
11.5
122.5
4.83
54.5
2.15
M 10
SCM 11
11
115
7.02
1.7
3.7
287
11.3
87
3.43
46
1.81
M 10
SCM 18
18
110
6.71
1.9
4.1
287
11.3
87
3.43
46
1.81
M 10
SCM 25
25
105
6.41
2.0
4.4
287
11.3
87
3.43
46
1.81
M 10
SCM 32
32
230
14.0
3.0
6.6
287
11.3
87
3.43
86
3.39
M 10
SCM 38
38
225
13.7
3.2
7.0
287
11.3
87
3.43
86
3.39
M 10
SCM 45
45
215
13.1
3.4
7.5
287
11.3
87
3.43
86
3.39
M 10
SCM 53
53
210
12.8
3.6
8.0
287
11.3
87
3.43
86
3.39
M 10
SCM 59
59
205
12.5
3.7
8.1
287
11.3
87
3.43
86
3.39
M 10
Saft is committed to the highest
standards of environmental
stewardship
Implementing this commitment to
minimise the impact of its
products and operations on the
environment means that Saft gives
priority to recycled over unrecycled
raw materials, reduces its plant
releases into the environment year
after year, minimizes water usage,
and ensures that its customers
have recycling solutions for their
batteries at the end of their lives.
receives and dispatches our
customers' batteries at the end of
their lives to fully approved
recycling facilities, in compliance
with the Laws governing
transboundary waste shipments.
Saft offers these services free of
charge to its customers.
Regarding industrial Ni-Cd
batteries, Saft has had
partnerships for many years with
collection companies in most EU
countries as well as in North
America. This collection network
In other countries, Saft assists its
customers in finding environmentally
sound recycling solutions. Please
contact your sales representative
for further information.
H
Please find a list of our collection
points on our web site.
L
W
2
Cells performances
Cell performance L type at +20°C ± 5°C (+68°F ± 9°F)
Performance for fully charged cells by a constant current charge according to IEC 60623 standard
Available amperes
Final voltage: 1.00 V/cell
Cell
type
C5
Ah
10
8
Hours
5
3
2
SCL 10 P
SCL 20 P
10
20
SCL 30 P
SCL 40 P
Minutes
1.13
2.26
1.36
2.73
2.00
4.00
3.03
6.07
4.05
8.10
30
3.27
3.94
6.00
40
4.36
5.25
8.00
SCL 55 P
55
5.83
7.22
SCL 70 P
70
7.42
9.19
9.50
90
4.87
9.73
60
45
30
6.10
12.2
7.00
14.0
8.20
16.4
13.2
16.0
19.8
22.4
25.8
12.7
17.6
21.3
26.4
29.9
34.4
11.0
17.8
25.3
30.8
38.5
44.0
50.6
14.0
22.6
32.2
39.2
49.0
56.0
64.4
90
60
45
30
5.20
10.4
6.00
12.0
7.00
14.0
Final voltage: 1.05 V/cell
Cell
type
C5
Ah
10
8
Hours
5
3
2
SCL 10 P
SCL 20 P
10
20
SCL 30 P
SCL 40 P
Minutes
1.09
2.18
1.33
2.65
1.92
3.84
2.80
5.60
3.60
7.20
30
3.18
3.90
5.82
40
4.24
5.20
7.76
SCL 55 P
55
5.83
7.15
SCL 70 P
70
7.42
9.10
8.90
4.27
8.53
12.0
14.4
18.0
20.0
22.8
11.9
16.0
19.2
24.0
26.7
30.4
10.8
17.2
24.2
29.0
35.2
39.6
44.0
13.7
21.9
30.8
36.9
44.8
50.4
56.0
90
60
45
30
3.60
7.20
4.20
8.40
4.80
9.60
Final voltage: 1.10 V/cell
Cell
type
C5
Ah
10
8
Hours
5
3
2
SCL 10 P
SCL 20 P
10
20
SCL 30 P
SCL 40 P
Minutes
1.04
2.08
1.26
2.53
1.82
3.64
2.57
5.13
3.15
6.30
30
3.12
3.83
5.70
40
4.16
5.10
7.60
SCL 55 P
55
5.72
7.01
SCL 70 P
70
7.28
8.93
8.20
5.60
11.2
10.4
12.0
14.7
16.4
19.2
10.9
13.8
16.0
19.6
21.9
25.6
10.6
15.6
20.4
24.2
29.7
33.7
38.5
13.4
19.8
25.9
30.8
37.8
42.9
49.0
90
60
45
30
3.07
6.13
3.60
7.20
4.00
8.00
4.40
8.80
Final voltage: 1.14 V/cell
Cell
type
C5
Ah
10
8
Hours
5
3
2
SCL 10 P
SCL 20 P
10
20
SCL 30 P
SCL 40 P
Minutes
0.97
1.94
1.15
2.30
1.60
3.20
2.20
4.40
2.70
5.40
30
3.00
3.64
5.40
40
4.00
4.85
7.20
SCL 55 P
55
5.61
6.81
SCL 70 P
70
7.14
8.66
10.2
12.0
12.8
14.4
10.0
7.50
12.2
9.15
13.6
16.0
17.1
19.2
10.1
14.1
17.6
19.8
23.1
25.7
29.7
12.9
18.0
22.4
25.2
29.4
32.7
37.8
3
Cell performance M type at +20°C ± 5°C (+68°F ± 9°F)
Performance for fully charged cells by a constant current charge according to IEC 60623 standard
Available amperes
Final voltage: 1.00 V/cell
Cell
type
C5
Ah
10
8
Hours
5
3
2
SCM 11
11
1.12
1.39
2.20
3.56
5.12
SCM 18
18
1.83
2.27
3.60
5.82
SCM 25
25
2.54
3.15
5.00
8.08
SCM 32
32
3.25
4.03
6.40
SCM 38
38
3.86
4.79
SCM 45
45
4.57
5.67
SCM 53
53
5.38
6.68
10.6
SCM 59
59
5.99
7.43
11.8
8.37
Minutes
20
15
90
60
45
30
6.60
9.13
11.3
14.7
18.5
10
5
1
21.1
24.4
29.0
44.0
46.2
75.6
Seconds
5
1
59.4
72.6
10.8
14.9
18.5
24.1
30.2
34.6
40.0
47.5
11.6
15.0
20.8
25.7
33.5
42.0
48.0
55.5
66.0
100
105
135
10.3
14.9
19.2
26.6
32.9
42.9
53.8
61.4
71.0
84.5
128
134
173
211
7.60
12.3
17.7
22.8
31.5
39.0
50.9
63.8
73.0
84.4
100
152
160
205
251
9.00
14.6
21.0
27.0
37.3
46.2
60.3
75.6
99.9
118
180
189
243
297
17.1
24.6
31.8
44.0
54.4
71.0
89.0
102
118
140
212
223
286
350
19.1
27.4
35.4
49.0
60.6
79.1
99.1
113
131
156
236
248
319
389
90
60
45
30
10
5
1
30
6.38
8.80
10.7
13.4
16.2
18.0
20.5
25.1
36.3
40.7
86.4
72.0
30
97.2
119
165
Final voltage: 1.05 V/cell
Cell
type
C5
Ah
10
8
Hours
5
3
2
SCM 11
11
1.11
1.38
2.18
3.52
5.06
SCM 18
18
1.81
2.25
3.56
5.76
SCM 25
25
2.52
3.13
4.95
8.00
SCM 32
32
3.22
4.00
6.34
SCM 38
38
3.83
4.75
SCM 45
45
4.54
5.63
SCM 53
53
5.34
6.63
SCM 59
59
5.94
7.38
8.28
Minutes
20
15
10.4
14.4
17.5
22.0
26.5
29.5
33.5
41.0
59.4
66.6
11.5
14.5
20.0
24.3
30.5
36.8
41.0
46.5
57.0
82.5
92.5
10.2
14.7
18.6
25.6
31.1
39.0
47.0
52.5
59.5
73.0
106
7.52
12.2
17.5
22.0
30.4
37.0
46.4
55.9
62.3
70.7
86.6
8.91
14.4
20.7
26.1
36.0
43.8
54.9
66.2
73.8
83.7
10.5
17.0
24.4
30.7
42.4
51.6
64.7
77.9
86.9
11.7
18.9
27.1
34.2
47.2
57.4
72.0
86.7
96.8
90
60
45
30
6.01
7.81
98.6
103
Seconds
5
1
51.7
62.7
84.6
103
118
143
118
150
182
125
141
179
217
148
167
212
257
121
175
196
249
302
135
195
218
277
336
10
5
1
30
110
Final voltage: 1.10 V/cell
Cell
type
C5
Ah
10
8
Hours
5
3
2
SCM 11
11
1.09
1.35
2.13
3.41
4.84
SCM 18
18
1.78
2.21
3.49
5.58
12.8
SCM 25
25
2.48
3.08
4.85
7.75
11.0
13.7
17.8
SCM 32
32
3.17
3.94
6.21
9.92
14.1
17.5
SCM 38
38
3.77
4.67
7.37
16.7
20.8
SCM 45
45
4.46
5.53
14.0
19.8
24.6
32.0
37.2
46.8
55.3
61.2
70.2
81.0
126
140
180
216
SCM 53
53
5.25
6.52
10.3
16.4
23.3
29.0
37.6
43.8
55.1
65.2
72.1
82.7
95.4
148
164
212
254
SCM 59
59
5.85
7.26
11.4
18.3
26.0
32.3
41.9
48.8
61.4
72.6
80.2
92.0
165
183
236
283
90
60
45
30
Minutes
20
15
10
5
1
30
5.35
6.71
8.73
11.8
7.92
9.84
9.09
Minutes
20
15
11.4
13.5
15.0
17.2
19.8
30.8
34.1
14.9
18.7
22.1
24.5
28.1
32.4
50.4
55.8
20.7
26.0
30.8
34.0
39.0
45.0
70.0
77.5
22.7
26.5
33.3
39.4
43.5
49.9
57.6
27.0
31.4
39.5
46.7
51.7
59.3
68.4
106
89.6
106
99.2
118
Seconds
5
1
44.0
52.8
72.0
100
86.4
120
128
154
152
182
Final voltage: 1.14 V/cell
Cell
type
C5
Ah
10
8
Hours
5
3
2
SCM 11
11
1.06
1.32
2.07
3.23
4.40
SCM 18
18
1.74
2.16
3.38
5.28
11.0
12.5
SCM 25
25
2.42
3.00
4.70
7.33
10.0
12.2
15.3
17.3
SCM 32
32
3.09
3.84
6.02
9.39
12.8
15.6
19.5
SCM 38
38
3.67
4.56
7.14
11.2
15.2
18.5
23.2
SCM 45
45
4.35
5.40
8.46
13.2
18.0
21.9
SCM 53
53
5.13
6.36
9.96
15.6
21.2
25.8
SCM 59
59
5.71
7.08
17.3
23.6
28.7
11.1
7.20
8.76
7.63
9.02
Seconds
5
1
46.2
10.6
11.9
13.9
17.2
26.4
29.7
37.4
14.8
17.3
19.4
22.7
28.1
43.2
48.6
61.2
20.5
24.0
27.0
31.5
39.0
60.0
67.5
85.0
22.2
26.2
30.7
34.6
40.3
49.9
76.8
26.4
31.2
36.5
41.0
47.9
59.3
91.2
27.5
31.2
36.9
43.2
48.6
56.7
70.2
32.3
36.8
43.5
50.9
57.2
66.8
82.7
36.0
40.9
48.4
56.6
63.7
74.3
92.0
86.4
75.6
105
109
134
103
129
160
108
122
153
189
127
143
180
223
142
159
201
248
4
Cell performance L type at +20°C ± 5°C (+68°F ± 9°F)
Performance after prolonged float charge of fully charged cells
Available amperes
Final voltage: 1.00 V/cell
Cell
type
C5
Ah
10
8
Hours
5
3
2
SCL 10 P
10
SCL 20 P
Minutes
1.13
1.36
2.00
3.03
20
2.26
2.73
4.00
6.07
SCL 30 P
30
3.27
3.94
6.00
SCL 40 P
40
4.36
5.25
8.00
SCL 55 P
55
5.83
7.22
SCL 70 P
70
7.42
9.19
9.50
90
60
45
3.85
4.38
5.31
5.95
7.70
8.76
10.6
11.9
30
6.81
13.6
12.5
14.4
17.2
19.0
21.4
12.7
16.7
19.2
23.0
25.4
28.6
11.0
17.8
24.0
27.7
33.5
37.4
42.0
14.0
22.6
30.6
35.3
42.6
47.6
53.5
90
60
45
30
Final voltage: 1.05 V/cell
Cell
type
C5
Ah
10
8
Hours
5
3
2
SCL 10 P
10
SCL 20 P
Minutes
1.09
1.33
1.92
2.55
3.10
3.58
4.21
4.77
20
2.18
2.65
3.84
5.10
6.19
7.17
8.42
9.54
SCL 30 P
30
3.18
3.90
5.82
SCL 40 P
40
4.24
5.20
7.76
SCL 55 P
55
5.83
7.15
SCL 70 P
70
7.42
9.10
8.10
5.46
10.9
10.3
12.1
14.6
15.9
17.8
10.8
13.8
16.1
19.4
21.2
23.7
10.8
15.7
20.8
24.3
28.5
31.5
34.3
13.7
20.0
26.5
31.0
36.3
40.1
43.7
90
60
Final voltage: 1.10 V/cell
Cell
type
C5
Ah
10
8
Hours
5
3
2
SCL 10 P
10
SCL 20 P
45
30
1.04
1.22
1.64
2.13
2.52
2.81
3.19
3.58
4.09
20
2.08
2.45
3.28
4.26
5.04
5.62
6.38
7.15
SCL 30 P
30
3.12
3.71
5.13
6.81
8.28
9.36
SCL 40 P
40
4.16
4.95
6.84
SCL 55 P
55
5.72
6.80
9.50
SCL 70 P
70
7.28
8.66
12.1
Minutes
9.07
11.2
12.2
8.18
14.0
11.0
12.5
14.9
16.3
18.7
12.9
16.3
18.9
22.6
25.1
28.1
16.5
20.7
24.0
28.7
32.0
35.8
90
60
Final voltage: 1.14 V/cell
Cell
type
C5
Ah
10
8
Hours
5
3
2
SCL 10 P
10
SCL 20 P
45
30
0.97
1.09
1.30
1.67
2.00
2.24
2.56
2.78
2.99
20
1.94
2.19
2.59
3.34
4.00
4.48
5.11
5.56
5.98
SCL 30 P
30
3.00
3.46
4.37
5.70
6.77
7.45
8.52
8.90
SCL 40 P
40
4.00
4.61
5.83
7.60
9.03
9.93
SCL 55 P
55
5.61
6.47
SCL 70 P
70
7.14
8.23
8.20
10.4
Minutes
11.4
11.9
9.79
13.1
10.7
13.0
14.5
16.4
17.8
20.2
13.7
16.6
18.4
20.9
22.7
25.7
5
Cell performance M type at +20°C ± 5°C (+68°F ± 9°F)
Performance after prolonged float charge of fully charged cells
Available amperes
Final voltage: 1.00 V/cell
Cell
type
C5
Ah
10
8
Hours
5
3
2
SCM 11
11
1.12
1.39
2.20
3.56
5.12
SCM 18
18
1.83
2.27
3.60
5.82
SCM 25
25
2.54
3.15
5.00
8.08
SCM 32
32
3.25
4.03
6.40
SCM 38
38
3.86
4.79
7.60
SCM 45
45
4.57
5.67
9.00
SCM 53
53
5.38
6.68
SCM 59
59
5.99
7.43
8.37
90
60
6.14
7.94
45
9.54
30
Minutes
20
15
10
5
1
30
12.1
15.2
17.1
19.5
23.2
35.2
37.0
10.0
13.0
15.6
19.8
24.8
28.0
32.0
38.0
57.6
60.5
11.6
14.0
18.1
21.7
27.5
34.4
38.9
44.4
52.8
80.0
84.0
10.3
14.9
17.9
23.1
27.8
35.2
44.1
49.8
56.8
67.6
102
12.3
17.7
21.2
27.4
33.0
41.8
52.3
59.1
67.5
80.3
122
14.5
21.0
25.2
32.5
39.1
49.5
62.0
70.0
79.9
95.1
10.6
17.1
24.6
29.6
38.3
46.0
58.2
73.0
82.4
94.1
11.8
19.1
27.4
32.9
42.6
51.2
64.8
81.3
91.8
90
60
45
30
5.42
7.22
Seconds
5
1
47.5
58.1
77.8
95.0
108
132
108
138
169
128
164
201
143
152
194
238
112
170
178
229
280
105.00 125
189
198
255
312
30
Final voltage: 1.05 V/cell
Cell
type
C5
Ah
10
8
Hours
5
3
2
SCM 11
11
1.11
1.38
2.18
3.52
4.55
SCM 18
18
1.81
2.25
3.56
5.76
SCM 25
25
2.52
3.13
4.95
8.00
SCM 32
32
3.22
4.00
6.34
SCM 38
38
3.83
4.75
7.52
SCM 45
45
4.54
5.63
8.91
SCM 53
53
5.34
6.63
SCM 59
59
5.94
7.38
7.45
8.87
8.57
Minutes
20
15
10
5
1
Seconds
5
1
47.0
10.5
12.3
13.7
15.5
18.8
27.2
30.5
38.8
11.8
14.0
17.1
20.1
22.4
25.4
30.8
44.6
50.0
63.5
10.4
12.3
16.4
19.5
23.8
27.9
31.2
35.3
42.8
61.9
69.4
88.1
10.2
13.2
15.8
21.0
24.9
30.5
35.8
39.9
45.2
54.7
79.2
12.2
15.7
18.7
24.9
29.6
36.2
42.5
47.4
53.7
65.0
94.1
14.4
18.6
22.1
29.5
35.1
42.9
50.3
56.1
63.6
77.0
10.5
17.0
21.9
26.1
34.8
41.3
50.4
59.2
66.1
74.9
11.7
18.9
24.4
29.1
38.7
45.9
56.1
65.9
73.5
90
60
45
30
Minutes
20
15
4.81
6.01
88.8
77.0
107
113
137
105
134
162
111
124
159
192
90.6
131
147
187
227
83.4
101.00
146
164
208
252
10
5
1
30
10.8
12.2
14.1
21.9
Final voltage: 1.10 V/cell
Cell
type
C5
Ah
10
8
Hours
5
3
2
SCM 11
11
1.09
1.35
2.13
3.17
4.07
SCM 18
18
1.78
2.21
3.49
5.19
6.65
SCM 25
25
2.48
3.08
4.85
7.21
9.24
SCM 32
32
3.17
3.94
6.21
9.23
SCM 38
38
3.77
4.67
7.37
SCM 45
45
4.46
5.53
8.73
SCM 53
53
5.25
6.52
SCM 59
59
5.85
7.26
7.87
9.84
6.87
8.47
9.88
Seconds
5
1
24.2
31.2
37.5
61.3
11.2
13.9
16.2
17.6
19.9
23.0
35.8
39.6
51.1
10.9
13.7
15.6
19.2
22.4
24.5
27.7
32.0
49.7
55.0
71.0
11.8
14.0
17.5
20.0
24.6
28.7
31.3
35.4
40.9
63.6
70.4
90.9
11.0
14.0
16.6
20.8
23.7
29.2
34.1
37.2
42.1
48.6
75.5
83.6
108
130
13.0
16.6
19.7
24.6
28.1
34.6
40.4
44.1
49.9
57.6
89.4
99.0
128
154
10.3
15.3
19.6
23.2
29.0
33.1
40.8
47.6
51.9
58.7
67.7
105
117
151
181
11.4
17.0
21.8
25.8
32.3
36.8
45.4
53.0
57.8
65.3
75.4
117
130
168
201
90
60
45
30
Minutes
20
15
10
5
1
30
4.83
11.5
17.7
85.2
109
Final voltage: 1.14 V/cell
Cell
type
C5
Ah
10
8
Hours
5
3
2
SCM 11
11
1.06
1.32
2.07
2.74
3.39
4.02
SCM 18
18
1.74
2.16
3.38
4.49
5.54
6.57
SCM 25
25
2.42
3.00
4.70
6.23
7.70
9.13
SCM 32
32
3.09
3.84
6.02
7.98
SCM 38
38
3.67
4.56
7.14
9.47
SCM 45
45
4.35
5.40
8.46
SCM 53
53
5.13
6.36
9.96
SCM 59
59
5.71
7.08
11.1
9.86
7.91
5.38
8.80
6.22
7.18
7.96
9.29
19.9
Seconds
5
1
25.1
31.0
10.2
11.8
13.0
15.2
18.8
28.9
32.6
41.0
50.7
11.0
12.2
14.1
16.3
18.1
21.1
26.1
40.2
45.2
57.0
70.4
11.7
14.1
15.6
18.1
20.9
23.2
27.0
33.4
51.5
57.9
72.9
11.7
13.9
16.7
18.6
21.5
24.8
27.5
32.1
39.7
61.1
68.7
86.6
11.2
13.9
16.5
19.8
22.0
25.5
29.4
32.6
38.0
47.0
72.4
81.4
103
127
13.2
16.3
19.3
23.3
25.9
30.0
34.6
38.4
44.7
55.4
85.2
95.9
121
149
14.7
18.2
21.5
25.9
28.8
33.4
38.5
42.7
49.8
61.7
94.9
134
166
107
90.0
107
Saft
Industrial Battery Group
12, rue Sadi Carnot
93170 Bagnolet - France
Tel: +33 1 49 93 19 18
Fax: +33 1 49 93 19 64
www.saftbatteries.com
Doc N° 21137-2-0306
Data in this document is subject to change without
notice and becomes contractual only after written
confirmation.
Société anonyme au capital de 31 944 000 €
RCS Bobigny B 383 703 873
Pragma - Printed in France - 2k