5130 Power Entry Modules with Line Filter www.schurter.com/PG06 IEC Appliance Inlet C20 with Filter, ECO design, front or rear side Mounting Screw-on or rivet mounting from front or rear side Screw-on Version Screw-on mounting from rear side, integrated thread Screw-on Version Standard- or Medical-Filter Snap-in mounting from front side Snap-In Version C20 70° C Description Characteristics Approvals Other versions on request -Panel Mount: Screw-on version from front or rear side, snap-in version from front side -2 Functions: Appliance Inlet Protection class I, Line filter in standard and medical version -Quick connect terminals -VDE Certificate Number: 104884 -UL File Number: E72928 -Optimal shielding due to completely closed filter case, unpotted Suitable for assembly in metal plated plastic housings -Version with class X1 and X2 (standard version) capacitors -Universal line filter for standard applications Designed for standard and medical applications -Suitable for use in equipment according to IEC/UL 60950 Suitable for use in medical equipment according to IEC/UL 60601-1 -Solder terminals -Medical version M80 -Capacity CX 330 nF References Fits to type: 4790; 4795 0104; 0104U; 1651; 1652; 1654; 4790; 4 795; VAC19KS Alternative: Standard version Alternative: version without line filter 4793; 4798 Weblinks pdf-datasheet, html-datasheet, General Product Information, Approvals, CE declaration of conformity, RoHS, CHINA-RoHS, REACH, Mating Connectors, e-Shop, SCHURTER-Stock-Check, Distributor-StockCheck, CAD-Drawings, Accessories, Wire Harnessing, Detailed request for product Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset. Technical Data Ratings IEC Ratings UL/CSA Leakage Current Dielectric Strength Impulse Withstand Voltage Allowable Operation Temp. Climatic Category Degree of Protection Protection Class Terminal Panel Thickness s Material: Housing 16 A @ Ta 40 °C / 250 VAC; 50 Hz 20 A @ Ta 40 °C / 250 VAC; 60 Hz standard < 0.5 mA (250 V / 60 Hz) medical < 5 µA (250 V / 60 Hz) > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) > 2.5 kV between L-N (CX2) > 4 kV between L-N (CX1) > 5 kV between L/N-PE (Cy2) voltage (1.2/50 μs) -25 °C to 85 °C 25/085/21 acc. to IEC 60068-1 from front side IP 40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminal 6.3 x 0.8 mm Screw: max 8 mm Mounting screw torque max 0.5 Nm Snap-in: 0.8 mm to 3 mm (all steps with one variant) Themoplast / steel tin-plated, black / metallic, UL 94V-0 Appliance-Inlet/-Outlet Line Filter MTBF C20 acc. to IEC 60320, UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 16 A, Protection Class I Standard and Medical Version, IEC 60939, UL 1283, CSA C22.2 no. 8 Technical Details > 3'000'000 h acc. to MIL-HB-217 F Connectors 1 5130 Power Entry Modules with Line Filter www.schurter.com/PG06 Dimension Front or rear side mounting for screws with nuts or blind rivets 79.5 12 64 3.5 35 ±0.10 12 3.6 max.R3 25.9 10.5 30.6 28 4.4 36 27 ±0.10 50.6 M3 33.9 42 ±0.15 42 Rear side mounting with pre-formed, threaded holes for M3 screws 79.5 12 64 3.5 36.5 ±0.1 12 M3 max.R3 25.9 10.5 30.6 28 4.4 36 28.5 ±0.1 50.6 3.6 33.9 42 ±0.15 42 Snap-in mounting from front side 79.5 12 64 3.5 35 ±0.10 12 25.9 10.5 30.6 28 4.4 36 33.9 2 Connectors max.R3 27 ±0.10 39 5130 Power Entry Modules with Line Filter www.schurter.com/PG06 Technical Data of Filter-Components Rated Current [A] Filter-Type Inductances L [mH] Capacitance CX [nF] Capacitance CY [nF] R [MΩ] 16 Standard Version 2 x 0.6 100 2.2 1 20 Standard Version 2 x 0.3 100 2.2 1 16 Medical Version (M5) 2 x 0.6 100 - 1 20 Medical Version (M5) 2 x 0.3 100 - 1 Diagrams Standard or medical version (M80) Medical version (M5) L L’ L L’ L1 1) PE Cx L1 Cy R L2 N Cy PE’ 2) 1) PE N’ 1) Line 2) Load Cx PE’ 2) R L2 N N’ 1) Line 2) Load Attenuation Loss - - - - differential mode _____ common mode Standard version 16 A 20 A Medical version (M5) 16 A 20 A All Variants Rated Current IEC [A] Rated Current Filter-Type UL [A] Panel mounting Mounting side Terminal Capacitor Order Number █ 16 16 Standard Version Snap-in Front Side Quick connect terminals 6.3 x 0.8 X2 100nF 5130.2000 16 20 Standard Version Snap-in Front Side Quick connect terminals 6.3 x 0.8 X2 100nF 5130.2001 16 16 Standard Version Snap-in Front Side Quick connect terminals 6.3 x 0.8 X1 100nF 5130.2100 16 20 Standard Version Snap-in Front Side Quick connect terminals 6.3 x 0.8 X1 100nF 5130.2101 16 16 Standard Version Screw-on/Rivet Front Side Quick connect terminals 6.3 x 0.8 X2 100nF 5130.0000 █ 16 16 Standard Version Screw-on/Rivet Front Side Quick connect terminals 6.3 x 0.8 X2 100nF 5130.0000.21 █ 16 20 Standard Version Screw-on/Rivet Front Side Quick connect terminals 6.3 x 0.8 X2 100nF 5130.0001 16 16 Standard Version Screw-on/Rivet Front Side Quick connect terminals 6.3 x 0.8 X1 100nF 5130.0100 16 20 Standard Version Screw-on/Rivet Front Side Quick connect terminals 6.3 x 0.8 X1 100nF 5130.0101 16 16 Standard Version Screw Rear Side Quick connect terminals 6.3 x 0.8 X2 100nF 5130.1000 16 20 Standard Version Screw Rear Side Quick connect terminals 6.3 x 0.8 X2 100nF 5130.1001 Connectors █ 3 5130 Rated Current IEC [A] Power Entry Modules with Line Filter www.schurter.com/PG06 Rated Current Filter-Type UL [A] Panel mounting Mounting side Terminal Capacitor Order Number Screw Rear Side Quick connect terminals 6.3 x 0.8 X1 100nF 5130.1100 16 16 Standard Version 16 20 Standard Version Screw Rear Side Quick connect terminals 6.3 x 0.8 X1 100nF 5130.1101 16 20 Medical Version (M5) Snap-in Front Side Quick connect terminals X1 100nF 5130.2301 16 16 Medical Version (M5) Snap-in Front Side Quick connect terminals 6.3 x 0.8 X2 100nF 5130.2200 16 20 Medical Version (M5) Snap-in Front Side Quick connect terminals 6.3 x 0.8 X2 100nF 5130.2201 16 16 Medical Version (M5) Snap-in Front Side Quick connect terminals 6.3 x 0.8 X1 100nF 5130.2300 16 16 Medical Version (M5) Screw-on/Rivet Front Side Quick connect terminals 6.3 x 0.8 X2 100nF 5130.0200 16 20 Medical Version (M5) Screw-on/Rivet Front Side Quick connect terminals 6.3 x 0.8 X2 100nF 5130.0201 16 16 Medical Version (M5) Screw-on/Rivet Front Side Quick connect terminals 6.3 x 0.8 X1 100nF 5130.0300 16 16 Medical Version (M5) Screw-on/Rivet Front Side Quick connect terminals 6.3 x 0.8 X1 100nF 5130.0300.21 16 20 Medical Version (M5) Screw-on/Rivet Front Side Quick connect terminals 6.3 x 0.8 X1 100nF 5130.0301 16 16 Medical Version (M5) Screw Rear Side Quick connect terminals 6.3 x 0.8 X2 100nF 5130.1200 16 20 Medical Version (M5) Screw Rear Side Quick connect terminals 6.3 x 0.8 X2 100nF 5130.1201 16 16 Medical Version (M5) Screw Rear Side Quick connect terminals 6.3 x 0.8 X1 100nF 5130.1300 16 20 Medical Version (M5) Screw Rear Side Quick connect terminals 6.3 x 0.8 X1 100nF 5130.1301 █ Most Popular. Availability for all products can be searched real-time:http://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER Type for screw on mounting from rear side has pre-threaded holes for M3 screws Suffix ".21" corresponds to the version with V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset. Packaging unit 20 Pcs Accessories Description Wire Harness Wire harness for SCHURTER products Assorted Covers Rear Cover 0859.0047 Cord retaining kits Cord retaining strain relief Flat head, L 4 Connectors 4700.0011 █ █ 5130 Power Entry Modules with Line Filter www.schurter.com/PG06 Mating Inlets/Plugs Category / Description Connector Overview complete IEC Connector C19, Rewireable, Straight 4795 IEC Connector C19, Rewireable, Angled 4790 Connector further types to 5130 Mating Outlets/Connectors Connector Overview complete IEC Connector C19, Rewireable, Straight 4795 IEC Connector C19, Rewireable, Angled 4790 IEC Connector C19, Rewireable, Straight 0104U Connector further types to 5130 Mating Outlets/Connectors shuttered Power Cord Overview complete Overview Power Cord with IEC Appliance Connector C19, V-Lock, straight VAC19KS Power Cord further types to 5130 24.08.2015 The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications. Connectors 5