5130 - Power Entry Modules with Line Filter

5130
Power Entry Modules with Line Filter
www.schurter.com/PG06
IEC Appliance Inlet C20 with Filter, ECO design, front or rear side Mounting
Screw-on or rivet mounting from front or rear side
Screw-on Version
Screw-on mounting from rear side, integrated
thread
Screw-on Version
Standard- or Medical-Filter
Snap-in mounting from front side
Snap-In Version
C20
70° C
Description
Characteristics
Approvals
Other versions on request
-Panel Mount:
Screw-on version from front or rear side, snap-in version from front
side
-2 Functions:
Appliance Inlet Protection class I, Line filter in standard and medical
version
-Quick connect terminals
-VDE Certificate Number: 104884
-UL File Number: E72928
-Optimal shielding due to completely closed filter case, unpotted
Suitable for assembly in metal plated plastic housings
-Version with class X1 and X2 (standard version) capacitors
-Universal line filter for standard applications
Designed for standard and medical applications
-Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
-Solder terminals
-Medical version M80
-Capacity CX 330 nF
References
Fits to type: 4790; 4795 0104; 0104U; 1651; 1652; 1654; 4790; 4
795; VAC19KS Alternative: Standard version Alternative: version without line filter 4793; 4798 Weblinks
pdf-datasheet, html-datasheet, General Product Information, Approvals,
CE declaration of conformity, RoHS, CHINA-RoHS, REACH, Mating
Connectors, e-Shop, SCHURTER-Stock-Check, Distributor-StockCheck, CAD-Drawings, Accessories, Wire Harnessing, Detailed request
for product
Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset.
The cord latching system prevents against accidental removal of the cordset.
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
Impulse Withstand Voltage
Allowable Operation Temp.
Climatic Category
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
16 A @ Ta 40 °C / 250 VAC; 50 Hz
20 A @ Ta 40 °C / 250 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
> 2.5 kV between L-N (CX2)
> 4 kV between L-N (CX1)
> 5 kV between L/N-PE (Cy2)
voltage (1.2/50 μs)
-25 °C to 85 °C
25/085/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class I acc. to IEC 61140
Quick connect terminal 6.3 x 0.8 mm
Screw: max 8 mm
Mounting screw torque max 0.5 Nm
Snap-in: 0.8 mm to 3 mm
(all steps with one variant)
Themoplast / steel tin-plated, black /
metallic, UL 94V-0
Appliance-Inlet/-Outlet
Line Filter
MTBF
C20 acc. to IEC 60320,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 16 A,
Protection Class I
Standard and Medical Version, IEC
60939, UL 1283, CSA C22.2 no. 8
Technical Details
> 3'000'000 h acc. to MIL-HB-217 F
Connectors
1
5130
Power Entry Modules with Line Filter
www.schurter.com/PG06
Dimension
Front or rear side mounting for screws with nuts or blind rivets
79.5
12
64
3.5
35 ±0.10
12
3.6
max.R3
25.9
10.5
30.6
28
4.4
36
27 ±0.10
50.6
M3
33.9
42 ±0.15
42
Rear side mounting with pre-formed, threaded holes for M3 screws
79.5
12
64
3.5
36.5 ±0.1
12
M3
max.R3
25.9
10.5
30.6
28
4.4
36
28.5 ±0.1
50.6
3.6
33.9
42 ±0.15
42
Snap-in mounting from front side
79.5
12
64
3.5
35 ±0.10
12
25.9
10.5
30.6
28
4.4
36
33.9
2
Connectors
max.R3
27 ±0.10
39
5130
Power Entry Modules with Line Filter
www.schurter.com/PG06
Technical Data of Filter-Components
Rated Current
[A]
Filter-Type
Inductances L [mH]
Capacitance
CX [nF]
Capacitance
CY [nF]
R [MΩ]
16
Standard Version
2 x 0.6
100
2.2
1
20
Standard Version
2 x 0.3
100
2.2
1
16
Medical Version (M5)
2 x 0.6
100
-
1
20
Medical Version (M5)
2 x 0.3
100
-
1
Diagrams
Standard or medical version (M80)
Medical version (M5)
L
L’
L
L’
L1
1) PE
Cx
L1
Cy
R
L2
N
Cy
PE’ 2)
1) PE
N’
1) Line
2) Load
Cx
PE’ 2)
R
L2
N
N’
1) Line
2) Load
Attenuation Loss
- - - - differential mode _____ common mode
Standard version
16 A
20 A
Medical version (M5)
16 A
20 A
All Variants
Rated Current
IEC [A]
Rated Current Filter-Type
UL [A]
Panel mounting
Mounting side
Terminal
Capacitor
Order Number
█
16
16
Standard Version
Snap-in
Front Side
Quick connect terminals 6.3 x 0.8
X2 100nF
5130.2000
16
20
Standard Version
Snap-in
Front Side
Quick connect terminals 6.3 x 0.8
X2 100nF
5130.2001
16
16
Standard Version
Snap-in
Front Side
Quick connect terminals 6.3 x 0.8
X1 100nF
5130.2100
16
20
Standard Version
Snap-in
Front Side
Quick connect terminals 6.3 x 0.8
X1 100nF
5130.2101
16
16
Standard Version
Screw-on/Rivet
Front Side
Quick connect terminals 6.3 x 0.8
X2 100nF
5130.0000
█
16
16
Standard Version
Screw-on/Rivet
Front Side
Quick connect terminals 6.3 x 0.8
X2 100nF
5130.0000.21
█
16
20
Standard Version
Screw-on/Rivet
Front Side
Quick connect terminals 6.3 x 0.8
X2 100nF
5130.0001
16
16
Standard Version
Screw-on/Rivet
Front Side
Quick connect terminals 6.3 x 0.8
X1 100nF
5130.0100
16
20
Standard Version
Screw-on/Rivet
Front Side
Quick connect terminals 6.3 x 0.8
X1 100nF
5130.0101
16
16
Standard Version
Screw
Rear Side
Quick connect terminals 6.3 x 0.8
X2 100nF
5130.1000
16
20
Standard Version
Screw
Rear Side
Quick connect terminals 6.3 x 0.8
X2 100nF
5130.1001
Connectors
█
3
5130
Rated Current
IEC [A]
Power Entry Modules with Line Filter
www.schurter.com/PG06
Rated Current Filter-Type
UL [A]
Panel mounting
Mounting side
Terminal
Capacitor
Order Number
Screw
Rear Side
Quick connect terminals 6.3 x 0.8
X1 100nF
5130.1100
16
16
Standard Version
16
20
Standard Version
Screw
Rear Side
Quick connect terminals 6.3 x 0.8
X1 100nF
5130.1101
16
20
Medical Version (M5)
Snap-in
Front Side
Quick connect terminals
X1 100nF
5130.2301
16
16
Medical Version (M5)
Snap-in
Front Side
Quick connect terminals 6.3 x 0.8
X2 100nF
5130.2200
16
20
Medical Version (M5)
Snap-in
Front Side
Quick connect terminals 6.3 x 0.8
X2 100nF
5130.2201
16
16
Medical Version (M5)
Snap-in
Front Side
Quick connect terminals 6.3 x 0.8
X1 100nF
5130.2300
16
16
Medical Version (M5)
Screw-on/Rivet
Front Side
Quick connect terminals 6.3 x 0.8
X2 100nF
5130.0200
16
20
Medical Version (M5)
Screw-on/Rivet
Front Side
Quick connect terminals 6.3 x 0.8
X2 100nF
5130.0201
16
16
Medical Version (M5)
Screw-on/Rivet
Front Side
Quick connect terminals 6.3 x 0.8
X1 100nF
5130.0300
16
16
Medical Version (M5)
Screw-on/Rivet
Front Side
Quick connect terminals 6.3 x 0.8
X1 100nF
5130.0300.21
16
20
Medical Version (M5)
Screw-on/Rivet
Front Side
Quick connect terminals 6.3 x 0.8
X1 100nF
5130.0301
16
16
Medical Version (M5)
Screw
Rear Side
Quick connect terminals 6.3 x 0.8
X2 100nF
5130.1200
16
20
Medical Version (M5)
Screw
Rear Side
Quick connect terminals 6.3 x 0.8
X2 100nF
5130.1201
16
16
Medical Version (M5)
Screw
Rear Side
Quick connect terminals 6.3 x 0.8
X1 100nF
5130.1300
16
20
Medical Version (M5)
Screw
Rear Side
Quick connect terminals 6.3 x 0.8
X1 100nF
5130.1301
█ Most Popular.
Availability for all products can be searched real-time:http://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER
Type for screw on mounting from rear side has pre-threaded holes for M3 screws
Suffix ".21" corresponds to the version with V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset.
Packaging unit 20 Pcs Accessories
Description
Wire Harness
Wire harness for SCHURTER products
Assorted Covers
Rear Cover
0859.0047
Cord retaining kits
Cord retaining strain relief
Flat head, L
4
Connectors
4700.0011
█
█
5130
Power Entry Modules with Line Filter
www.schurter.com/PG06
Mating Inlets/Plugs
Category / Description
Connector Overview complete
IEC Connector C19, Rewireable, Straight
4795
IEC Connector C19, Rewireable, Angled
4790
Connector further types to 5130
Mating Outlets/Connectors
Connector Overview complete
IEC Connector C19, Rewireable, Straight
4795
IEC Connector C19, Rewireable, Angled
4790
IEC Connector C19, Rewireable, Straight
0104U
Connector further types to 5130
Mating Outlets/Connectors shuttered
Power Cord Overview complete
Overview Power Cord with IEC Appliance Connector C19, V-Lock, straight
VAC19KS
Power Cord further types to 5130
24.08.2015
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.
Connectors