D8M 125V Non resettable fuses www.schurter.com/PG999 125 VAC · 125 VDC · Quick-Acting F Description -Low Breaking Capacity -Type D8M 125V (0.16 - 6.3 A), A12M 125V (10 A) OU T Miniature Fuse, 6.3 x 32 mm, Quick-Acting F, 125 VAC, 125 VDC References We recommend for new applications the type 172582 Last order date: 31.12.2013 Weblinks pdf-datasheet, html-datasheet, General Product Information, Approvals, CE declaration of conformity, RoHS, CHINA-RoHS, REACH, e-Shop, SCHURTER-Stock-Check, Distributor-Stock-Check, Detailed request for product Technical Data Dimension E- Resistance to Vibration Shocks Bumps Salt Mist acc. to NF C 20-706 / IEC 60068-2-6, test Fc acc. to NF C 20-706 / IEC 60068-2-27 acc. to NF C 20-729 / IEC 60068-2-29 acc. to NF C 20-711 / IEC 60068-2-11 32 mm ø 6.35 ±0.06 125 VAC, 125 VDC 0.16 - 6.3 A 5 kA Quick-Acting F Fuseholder / Clip -40 °C to 70 °C 40/070/56 acc. to IEC 60068-1 Glass 2.2 g 0 °C to 60 °C, max. 70% r.h. Current, Rated voltage AS Rated Voltage Rated current Breaking Capacity Characteristic Mounting Admissible Ambient Air Temp. Climatic Category Material: Tube Unit Weight Storage Conditions Product Marking 0 PH 32 -1 Pre-Arcing Time Rated Current In 0.16 A - 6.3 A 1.2 x In min. 1.65 x In max. 3.0 x In max. 60 min 60 min 400 ms Fuses 1 D8M 125V Non resettable fuses www.schurter.com/PG999 Time-Current-Curves T 100000 10000 1000 OU Time in Seconds 100 10 1 0.1 0.01 0.001 10 1 All Variants Rated Current [A] Rated Voltage [VAC] Rated Voltage [VDC] Breaking Capacity 0.16 125 125 1) 0.25 125 125 1) 125 125 1) 1 125 125 1) 1.6 2.5 6.3 Order Number Voltage Drop 1.0 In typ. [mV] 1600 l 7015.6410 1400 l 7015.6310 500 l 7015.6320 600 l 7015.6340 AS 0.4 E- Multiple of Rated Current In 125 125 1) 550 l 7015.6420 125 125 1) 400 l 7015.6360 125 125 1) 250 l 7015.6380 Availability for all products can be searched real-time:http://www.schurter.com/en/Stock-Check/ Stock-Check-SCHURTER 1) 5 kA @ 125 VAC , p.f. = 0.3 - 0.4 / 5 kA @ 125 VDC Small Box Pack (10 pcs.) 2 Fuses 21.11.2014 PH Packaging Unit The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications.