GDE25-6

Switchmode/High Frequency
Gate Drive Transformers
GDE25-6
Description:
Triad gate drive transformers are used universally in all high frequency switching
topologies to isolate the control circuitry from the line-connected switches. The
Windings are interleaved for the lowest possible leakage inductance. Turn ratios
optimize coupling and enhance performance. Available with single or dual
secondaries, these transformers are constructed of UL rated 130° materials and are
easily standardized at operating frequencies of 200 kHz and beyond.
Electrical Specifications (@25C):
Max
Max
Min.
Max.
Min.
Turns
DCR 1-2
DCR Gate
ET Product
Leakage
Inductance
Ratio
.350 Ω
1.75 Ω
540 VµSec
3.5 µH
.680 mH
1:1.5:1.5
1.100
Weight: .045 oz.
1.20
Technical Notes:
1. Drive to gate winding hi-pot tested at 3,750 VRMS.
2. Derate ET product by 32% for 50 kHz, 50% for 100 kHz and for
unidirectional operation.
3. Operation at rated current per winding renders approximately 40°
temperature rise.
.025 SQ
.150 MIN
.280 MAX
.700
1.040
Schematic:
.600
.200
.650
3
.850
GATE
1
4
DRIVE
2
5
.700
GATE
2
6
1
.040 DIA TYP
6 5
.850
RoHS Compliance: As of manufacturing date February 2005, all standard products
meet the requirements of 2011/65/EU, known as the RoHS initiative.
460 Harley Knox Blvd.
Perris, California 92571
.200
2 PLCS
MOUNTING HOLE PATTERN TOP VIEW
* Upon printing, this document is considered “uncontrolled”. Please contact Triad
Magnetics’ website for the most current version.
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
.600
4 3
Publish Date: December 4, 2013