QPI-6 14 A Active EMI Filter for 48 Vdc Bus Data sheet

QPI-6
 
QUIETPOWER
14 A Active EMI Filter SIP for 48 Vdc Bus
Description:
Features:
The QPI-6 active EMI filter attenuates conducted commonmode (CM) and differential-mode (DM) noise over the
CISPR22 frequency range of 150 kHz to 30 MHz. The product
is designed for use on 48 Vdc bus (36 – 76 Vdc) systems, with
100 Vdc surge capability. The QPI-6’s 14 A rating supports
multiple DC-DC converter loads up to an ambient
temperature of 65°C without de-rating. Designed for the
telecom and ITE bus range, the QPI-6 supports the PICMG®
3.0 specification for filtering system boards to the EN55022
Class B limits.













In comparison to passive solutions, the use of active filtering
reduces the volume of the common-mode choke, providing a
low profile, surface mount device. Smaller size saves valuable
board real estate and the reduced height enhances airflow in
blade applications.
40 dB CM attenuation at 250 KHz (50Ω)
80 dB DM attenuation at 250 KHz (50Ω)
80 Vdc (max input)
100 Vdc surge 100 ms
1,500 Vdc hipot hold off to shield plane
14 A rating
25.3 x 25.3 x 5.0 mm Lidded SiP (System-in-Package)
24.9 x 24.9 x 4.4 mm Open-frame SiP
Low profile LGA package
-40° to +125°C Ambient temperature (see Figure 12)
Efficiency >99%
Connect in series for higher attenuation
TÜV Certified
Applications
The QPI-6 is available as a
lidded or an open-frame SiP
(System-in-Package)
with
LGA mounting. Evaluation
boards are available to allow
for quick in-circuit testing of
the QPI-6LZ within an
existing
system
design.






Figure 1 - QPI-6LZ
(~1 in2 area)
ATCA blades
Telecom base stations
IBA & distributed power
Network switches and routers
Optical line-cards
TD-SCMA wireless infrastructure
Typical Application:
Figure 2 – Typical QPI-6 application schematic with a Vicor brick converter. (1)
Note 1: CB1 capacitor, referenced in all schematics, is a 47uF electrolytic; United Chemi-Con EMVE101ARA470MKE0S or equivalent.
CY1 to CY4, referenced in all schematics, are 4.7nF hi-voltage safety capacitors; Vishay VY1472M63Y5UQ63V0 or equivalent.
CIN is the manufacturer’s recommended value for input capacitor.
Picor Corporation · picorpower.com
QPI-6
Rev 2.6, Page 1 of 13
QPI-6
 
QUIETPOWER
Absolute Maximum Ratings – Exceeding these parameters may result in permanent damage to the product.
Input Voltage, BUS+ to BUS-, continuous
Input Voltage, BUS+ to BUS-, 100ms transient
BUS+/ BUS- to Shield pads, hi-pot
Input to output current, continuous @ 25°C TA
Input to output current, 10 seconds @ 25°C TA
Power dissipation, @ 65°C TA, 14 A(2)
Operating temperature - TA
Thermal resistance(2) - RJ-A, using PCB layout in Figure 24
Thermal resistance(2) - RJ-PCB
Storage temperature, JEDEC Standard J-STD-033B
Reflow temperature, 20 s exposure
ESD, Human body model (HBM)
-80 to 80 Vdc
-100 to 100 Vdc
-1500 to 1500 Vdc
14 Adc
20 Adc
2.3 W
-40 to 125 °C
20 °C/W
8 °C/W
-55 to 125 °C
245 °C
-2000 to 2000 V
Electrical Characteristics – Parameter limits apply over the operating temp. range, unless otherwise noted.
Parameter
Notes
BUS+ to BUS- input range
Measured at 14 A, 65°C ambient temperature(2)
BUS+ to QPI+ voltage drop
Measured at 14 A, 65°C ambient temperature(2)
BUS- to QPI- voltage drop
Measured at 14 A, 65°C ambient temperature(2)
Common mode attenuation
VBUS = 48 V, Frequency = 250 KHz, line impedance = 50Ω
Differential mode attenuation VBUS = 48 V, Frequency = 250 KHz, line impedance = 50Ω
Input bias current at 80 V
Input current from BUS+ to BUSNote 2: See Figure 12 for the current de-rating curve.
Min
30
Typ
Max
80
135
29
Units
Vdc
mVdc
mVdc
dB
dB
mA
40
80
8
Pad Descriptions
Pad Number
12, 13, 14
1, 15, 16
7, 8, 9
2, 3, 4
5, 6
Name
BUS+
BUSQPI+
QPIShield
Description
Positive bus potential
Negative bus potential
Positive input to the converter
Negative input to the converter
Shield connects to the system chassis or to a safety ground.
10
THERM1
These pads are electrically isolated from the internal circuitry of
the QPI-6. Either connecting THERM1 to QPI+ and THERM2 to
BUS+, or to copper region(s) not connected to Shield, is
recommended to help with thermal management.
11
THERM2
LGA Pattern (Top View)
THERM2
12
11
THERM1
10
9
13
8
BUS+
QPI+
14
7
15
6
16
5
BUS-
Shield
1
2
3
4
QPI-
Ordering Information
Part Number
QPI-6LZ(3)
QPI-6LZ-01
Description
QPI-6 LGA Package, RoHS Compliant
QPI-6 LGA Package, RoHS Compliant, Open Frame Package
Note 3: QPI-6LZ is a non-hermetically sealed package. Please read the “Post Solder Cleaning” section on page 12.
QPI-6 Evaluation Boards
Part #
Description:
QPI-6-EVAL1
A QPI-6LZ mounted on a small evaluation board with screw terminal blocks to allow for easy connection into an
existing system.
QPI-6-CB1
A QPI-6LZ mounted on a carrier board designed for use with DOSA compliant footprint dc-dc converters. Screw
terminal blocks to allow for easy connection into an existing system.
Picor Corporation · picorpower.com
QPI-6
Rev 2.6, Page 2 of 13
QPI-6
 
QUIETPOWER
Applications Information
EMI Sources
Many of the components in today’s power conversion
modules are sources of high-frequency EMI noise generation.
Diodes, high-frequency switching devices, transformers and
inductors, and circuit layouts passing high dv/dt or di/dt
signals are all potential sources of EMI.
EMI is propagated either by radiated or conductive means.
Radiated EMI can be sourced from these components as well
as by circuit loops that act like antennas and broadcast the
noise signals to neighboring circuit paths. This also means
that these loops can act as receivers of a broadcasted signal.
This radiated EMI noise can be reduced by proper circuit
layout and by shielding potential sources of EMI transmission.
pass the EN55022 class B limits.
The other component of the passive filter is the differential
LC network. Again, the inductor is chosen such that it will
present a high-impedance in the differential EMI loop at the
EMI’s base frequency. The differential capacitor will then
shunt the EMI back to its source. The QPI-6 was specifically
designed to work with conventional switching frequency
converters like Vicor’s Brick products; Micro, Mini and Maxi
modules; as well as converters from various vendors.
Active EMI Filtering
There are two basic forms of conducted EMI that typically
need to be filtered; namely common-mode (CM) and
differential-mode (DM) EMI. Differential-mode resides in the
normal power loop of a power source and its load; where the
signal travels from the source to the load and then returns to
the source. Common-mode is a signal that travels through
both leads of the source and is returned to earth via parasitic
pathways, either capacitively or inductively coupled.
PICOR’s QPI-6 active EMI filter uses the same basic principles
for filtering as the passive approach, but its active commonmode filter can perform as well as a passive filter, when
filtering lower frequencies, in much less board area.
Figure 8 to Figure 11 are the resulting EMI plots, after filtering
by the QPI-6, of the total noise, both common and differential
mode, of a Vicor Brick and a DOSA (Distributed-power Open
Standards Alliance) compliant converter. These converters
are mounted on a QPI-6 evaluation board and tested under
various loads. The red and blue traces represent the positive
and negative branches of total noise, as measured using an
industry standard LISN setup, as is shown in Figures 6 and 7.
Differential-mode EMI is typically larger in magnitude than
common-mode, since common-mode is produced by the
physical imbalances in the differential loop path. Reducing
differential EMI will cause a reduction in common-mode EMI.
Passive EMI Filtering
The basic premise of filtering EMI is to insert a highimpedance, at the EMI’s base frequency, in both the
differential and common-mode paths as it returns to the
power source.
Passive filters use common-mode chokes and “Y” capacitors
to filter out common-mode EMI. These chokes are designed
to present a high-impedance at the EMI frequency in series
with the return path, and a low impedance path to the earth
signal via the “Y” caps. This network will force the EMI signals
to re-circulate within a confined area and not to propagate to
the outside world. Often two common-mode networks are
required to filter EMI within the frequency span required to
Picor Corporation · picorpower.com
QPI-6
Figure 3 – Simplified Active EMI filter circuit.
Typically, the lower the frequency the greater the needed
inductance would be to properly filter the EMI signal. This
means either a larger core or a greater number of turns on a
smaller core. A larger core requires more board space, where
a smaller core with more turns has a greater amount of
unwanted parasitics that can affect the filters ability to
attenuate EMI signals.
Figure 3 is a simplified schematic of the QPI-6’s active and
passive circuitry used for EMI filtering. The QPI-6’s active
filter uses a small high-frequency common-mode transformer
to filter the higher frequencies and adds a sensing element to
it so that the lower frequency common mode signal can be
sensed and a correction signal can be generated and inserted
into the shield connection. By this means, the QPI-6 is
capable of providing EMI filtering of converters in far less
space than standard passive filters and can provide filtering
over the entire EN55022 class B range.
Rev 2.6, Page 3 of 13
QPI-6
 
QUIETPOWER
EMI Management
The more effectively EMI is managed at the source, namely
the power converter, the less EMI attenuation the filter will
have to do. The addition of “Y” capacitors to the input and
output power nodes of the converter will help to limit the
amount of EMI that will propagate to the input source.
favor one topology versus another. The EMI generated by
the “base-plate” configuration is much greater than that
generated by the “open-frame”. Selecting the right topology
will greatly reduce the amount of EMI signal that needs to be
filtered.
Figure 2 shows the base-plate topology of re-circulating “Y”
caps. Here, CY1 to CY4 are connected to each power node of
the dc-dc converter, and then are commoned together on a
copper shield plane created under the converter. The
addition of the copper shield plane helps in the containment
of the radiated EMI, converting it back to conducted EMI and
shunting it back to its source.
The RY resistor, connected between the shield plane and the
QPI’s shield pin, provides an impedance that makes the QPI’s
common mode noise cancelation signal more effective at
removing the common mode noise that would normally
return to the shield/earth connection. It is important when
laying out the QPI that the RY resistor connects to the QPI’s
shield pin before making the connection to earth ground.
Figure 4 – An unfiltered converter’s response to “open-frame”
(light blue) and “base-plate” (purple) EMI configurations.
There are two basic topologies for the connection of the recirculating “Y” capacitors, referred to as “open-frame” and
“base-plate”. Figure 4 illustrates how a converter can
In Figure 5, the open-frame topology is shown where the “Y”
capacitors (CY1 and CY2) re-circulate the EMI signals between
the positive input and output, and the negative input and
output nodes of the power conversion stage.
Figure 5 - Typical 'open-frame" application.
Picor Corporation · picorpower.com
QPI-6
Rev 2.6, Page 4 of 13
 
QPI-6
QUIETPOWER
Attenuation Test Setups:
Figure 6 - Open-frame EMI test setup using the QPI-6-CB1 carrier board with 48V converter.
Figure 7 - Base-plate EMI test setup using the QPI-6-CB1 carrier board with 48V converter.
In Figures 6 and 7, C1 is the required 47uF capacitor (United
Chemi-Con EMVE101ARA470MKE0S or equivalent), C2 is a
converter input cap (value dependant on converter), and CY
caps are 4.7nF ceramic (Murata GRM31BR73A472KW01L or
equivalent).
Attenuation Plots: Converters in base-plate and open-frame configurations, tested as shown in Figure 7.
Figure 8 - V48B12C250BN using base-plate “Y” capacitors
with a 162W load.
Picor Corporation · picorpower.com
Figure 9 – V48B3V3C150BN using base-plate “Y” capacitors
with a 141W load.
QPI-6
Rev 2.6, Page 5 of 13
QPI-6
 
Figure 10 – Ericsson PKM 4402NG using open-frame “Y”
capacitors on QPI-6-CB1 evaluation board, 414W load.
QUIETPOWER
Figure 11 - Ericsson PKM 4402NG using base-plate “Y”
capacitors on QPI-6-CB1 evaluation board, 414W load
Current De-Rating: mounted to QPI-6-EVAL1 evaluation board.
20
2.5
18
2.0
Maximum Current (Amps)
14
12
1.5
10
8
1.0
6
4
0.5
Maximum Power Dissipation (Watts)
16
2
0
0.0
-40
-15
QPI-6 Current
10
35
QPI-6 Power Dissipation
60
85
110
Ambient Temperature (°C)
Figure 12 - Current de-rating and power dissipation over ambient temperature range.
The de-rating curve in Figure 12 is based on the maximum
allowable internal component temperature and the 14A
maximum rating of the QPI-6. The power dissipation curve is
based on the current squared multiplied by the internal
Picor Corporation · picorpower.com
QPI-6
resistance between the inputs and outputs of the filter. The
internal resistance value is temperature compensated for the
power dissipation curve. The left axis is in amps for the solid
trace, the right axis is in watts for the dashed trace.
Rev 2.6, Page 6 of 13
QPI-6
 
QUIETPOWER
QPI Application Circuits:
Filtering Dual Converters
Figure 13 – The QPI-6 filtering dual supplies, using a single RY resistor. (4)
The shield plane under the two converters in Figure 13 should
be one contiguous plane under both. The circuit in Figure 13 is
capable of filtering more converters than shown, up to the
maximum current limit of the QPI-6. In Figure 14, a separate
shield plane is required for each converter along with a
separate RY resistor.
The QPI-6 is not designed to be used in parallel with another
QPI-6 to achieve a higher current rating, but it can be used
multiple times within a system design.
Filtering Parallel Converters
Figure 14 – Dual QPI-6’s filtering paralleled converters feeding a common load. (4)
Note 4: In Figures 12 and 13; CIN1 and CIN2, CY1 through CY8, should be the value and voltage rating recommended by the converter’s manufacturer.
Picor Corporation · picorpower.com
QPI-6
Rev 2.6, Page 7 of 13
 
QPI-6
QUIETPOWER
Output to Chassis Connection Using the QPI-6
Figure 15 – Connecting the converter’s output ground to chassis through an inductor. (4)
Figure 16 -Total Noise EMI Plots of PKM 4402NG, connected as shown in Figure 15
The direct connection of the converter’s output to the
earth/chassis will degrade the EMI attenuation performance of
the QPI-6. Picor recommends that the connection to the earth
be made through a series inductor, rated to the maximum
output current of the converter, as shown in Figure 15. The
EMI plot shown in Figure 16 is of the same converter as in
Picor Corporation · picorpower.com
QPI-6
Figure 11, but uses an inductor in place of RY and has the
converter’s output ground connected to the shield plane.
The connection of the shield plane directly to the chassis/earth
will also degrade EMI attenuation by the QPI-6 and is therefore
not recommended.
Rev 2.6, Page 8 of 13
QPI-6
 
QUIETPOWER
QPI Insertion Loss Measurements
90
80
70
QPI Insertion Loss Equation:
Attenuation [dB]
60
50
40
30
20
10
0
0.01
0.1
QPI-6 Common
1
QPI-6 Differential
10
Frequency [MHz]
Figure 17 - Attenuation curves into a 50Ω line impedance, bias from a 48V bus.
QPI Insertion Loss Test Circuits
Figure 18 – Test Set-up to measure Differential Mode EMI currents in Figure 17.
Figure 19 - Test Set-up to measure Common Mode EMI currents in Figure 17.
Picor Corporation · picorpower.com
QPI-6
Rev 2.6, Page 9 of 13
QPI-6
 
QUIETPOWER
Mechanicals
 0.006" [0.15mm] max.
 0.006" [0.15mm] max.

QPI-6LZ
0.996" [25.30 mm]


U.S. and Foreign Patents/Patents Pending
Lot #
Date Code
Pin 1 indicator
0.996" [25.30 mm]
0.196" [4.98 mm]
Figure 20 - Lidded Package Dimensions, tolerance of ±0.004”
Figure 21 - Open-frame Package dimensions, tolerance of ±0.004”. Pick and Place from label center.
Picor Corporation · picorpower.com
QPI-6
Rev 2.6, Page 10 of 13
QPI-6
 
QUIETPOWER
Pad and Stencil Definitions:
QPI-6 LGA
Pattern
(Bottom View)
QPI-6 PCB
Receptor Pattern
(Top View)
0.996" (LID)
0.979" (OF)
0.441"
0.441"
0.300"
0.300"
0.100"
0.100"
0.441"
0.300"
0.441"
0.441"
0.300"
0.441"
0.100"
0.441"
0.000"
0.300"
0.100"
0.300"
0.300"
0.100"
0.441"
0.100"
0.100"
0.000"
0.000"
0.996" (LID)
0.100"
0.979" (OF)
0.300"
0.000"
Figure 22 - Bottom view of open-frame (OF) and lidded (LID) products. (All dimensions are in inches.)
45.000°
0.145"
0.082"
0.041"
0.000"
0.149"
0.085"
0.043"
0.000"
0.129"
0.073"
0.037"
0.000"
0.082"
0.041"
0.000"
0.086"
0.043"
0.000"
0.073"
0.037"
0.000"
13 places
0.073"
0.037"
0.000"
2 places
R0.041
R0.043
0.1250"
R0.037
0.086"
0.043"
0.000"
0.082"
0.041"
0.000"
0.129"
LGA Pad Detail:
1 place
0.112"
Receiving Pad Detail:
Stencil Detail:
Figure 23 - Recommended receptor and stencil patterns. (All dimensions are in inches.)
Stencil definition is based on a 6mil stencil thickness, 80% of LGA pad area coverage. LGA Package dimensions are for both the OpenFrame and Lidded versions of the QPI-6.
Picor Corporation · picorpower.com
QPI-6
Rev 2.6, Page 11 of 13
QPI-6
 
QUIETPOWER
QPI-6 PCB Layout Recommendations:
Figure 24 - 3D view of paralleling planes underneath the QPI-6.
PCB Layout
When laying out the QPI-6 EMI filter it is important for the
designer to be aware of the radiated EMI field that all
converters emit and to place the QPI-6 outside of this field
area. It is also recommended that the bus lines feeding into
the QPI filter are not routed such that they lie between the
QPI and the converter, or that their copper planes over-lap on
inner layers. This can cause EMI noise to be coupled from
input to output via the parasitic capacitance between the
planes.
Post Solder Cleaning
Picor’s LZ version QP SIPs are not hermetically sealed and
must not be exposed to liquid, including but not limited to
cleaning solvents, aqueous washing solutions or pressurized
sprays. When soldering, it is recommended that no-clean flux
solder be used, as this will ensure that potentially corrosive
mobile ions will not remain on, around, or under the module
following the soldering process. For applications where the
end product must be cleaned in a liquid solvent, Picor
recommends using the QPI-6LZ-01, open-frame version of the
EMI filter.
In Figure 24, the QPI-6 is located ~1.5 inches from the
converter’s input pins, and the BUS voltage pins are located
on the side farthest away from the converter, to keep the
radiated EMI from by-passing the filter and coupling directly
to the BUS feeds.
QPI-6 Mechanical Data
Datum
Units
QPI-6LZ
QPI-6LZ-01
Notes
FITS
Failure/Billion Hrs.
208
208
FITS based on the BellCore Standard TR-332
MTBF
Weight
MSL
Million Hrs.
grams
4.81
5.4
3
4.81
3.1
3
MTBFs based on the BellCore Standard TR-332
°C/20 seconds
245
245
IPC/JEDEC J-STD-020D
Peak reflow
Temperature
Picor Corporation · picorpower.com
QPI-6
Rev 2.6, Page 12 of 13
QPI-6
 
QUIETPOWER
Warranty
Vicor products are guaranteed for two years from date of shipment against defects in material or workmanship when in
normal use and service. This warranty does not extend to products subjected to misuse, accident, or improper
application or maintenance. Vicor shall not be liable for collateral or consequential damage. This warranty is extended to
the original purchaser only.
EXCEPT FOR THE FOREGOING EXPRESS WARRANTY, VICOR MAKES NO WARRANTY, EXPRESS OR LIMITED, INCLUDING,
BUT NOT LIMITED TO, THE WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
Vicor will repair or replace defective products in accordance with its own best judgment. For service under this
warranty, the buyer must contact Vicor to obtain a Return Material Authorization (RMA) number and shipping
instructions. Products returned without prior authorization will be returned to the buyer. The buyer will pay all charges
incurred in returning the product to the factory. Vicor will pay all reshipment charges if the product was defective within
the terms of this warranty.
Information published by Vicor has been carefully checked and is believed to be accurate; however, no responsibility is
assumed for inaccuracies. Vicor reserves the right to make changes to any products without further notice to improve
reliability, function, or design. Vicor does not assume any liability arising out of the application or use of any product or
circuit; neither does it convey any license under its patent rights nor the rights of others. Vicor general policy does not
recommend the use of its components in life support applications wherein a failure or malfunction may directly threaten
life or injury. Per Vicor Terms and Conditions of Sale, the user of Vicor components in life support applications assumes
all risks of such use and indemnifies Vicor against all damages.
Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and
accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom power
systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for
its use. Vicor components are not designed to be used in applications, such as life support systems, wherein a failure or
malfunction could result in injury or death. All sales are subject to Vicor’s Terms and Conditions of Sale, which are
available upon request.
Specifications are subject to change without notice.
Vicor Corporation
25 Frontage Road
Andover, MA 01810
USA
Picor Corporation
51 Industrial Drive
North Smithfield, RI 02896
USA
Customer Service: [email protected]
Technical Support: [email protected]
Tel: 800-735-6200
Fax: 978-475-6715
Picor Corporation · picorpower.com
QPI-6
Rev 2.6, Page 13 of 13