ROHM BD9251FV

1/4
STRUCTURE
Silicon Monolithic Integrated Circuit
TYPE
BD9251FV
PRODUCT
Preamp IC for Pyroelectricity Infrared Sensor
FEATURES
1)Amplifier for sensor output
2)Comparator for sensor output
3)Built-in voltage regulator
4)Built-in moving detector
●Absolute Maximum Ratings (Ta=25℃)
Parameter
Symbol
Supply Voltage
VDD
Power Dissipation
Pd
Operating Temperature
Topr
Limits
Units
-0.3~7.0
V
440
mW
※1
-30~75
℃
-55~125
℃
Storage Temperature
Tstg
※1. It reduces 3.5mW/℃ then Ta≧25℃. (On glass epoxy board of 70mm×70mm×1.6mm)
●Operating Conditions
Parameter
Symbol
Min.
Typ.
Supply Voltage
VDD
2.97
5.0
6.0
V
A1P_IN
Offset Voltage
VA1P_IN_OFFSET
-
1.5
-
V
Max. Units
This product don't design for protection radioactive rays.
REV. A
Remarks
VDRAIN=2.3V
2/4
●Electric Characteristics (VDD=5.0V, Ta=25℃)
Parameter
Symbol
Spec
Units
Conditions
Min.
Typ.
Max.
IDD
-
300
400
uA
Output no load
VDRAIN
2.0
2.3
-
V
VDD≧2.97V, IDRAIN≦100µA
AMP1/AMP2 Input Voltage
VIN
0.1
-
VDD-0.8
V
AMP1/AMP2 Gain
AG
-
-
46
dB
AMP1/AMP2 Unity Gain
AUG
-
1
-
MHz
VA1OFF
-
-
10
mV
VA2OUT
-
1.5
-
V
IA2OUT1
20
30
-
µA
IA2OUT2
20
200
-
µA
VOH
VDD-0.6
-
VDD
V
IOH=-1mA
VOL
0
-
0.6
V
IOL=+1mA
Supply Current
DRAIN Output Voltage
AMP1 Input Offset Voltage
AMP2 Output Offset Voltage
A2_OUT Output Current (source)
A2_OUT Output Current (sink)
D_OUT / T_OUT
Output "H" Voltage
D_OUT / T_OUT
Output "L" Voltage
●Package Outline
Fig.1 SSOP-B14 Package (Unit:mm)
D9251
Lot No.
REV. A
3/4
●PIN Description
PIN No.
PIN Name
1
GND
2
NC
3
DRAIN
Function
Remarks
Ground
NC
Power supply for pyroelectric infrared sensor
4
A1P_IN
Sensor input
5
A1N_IN
Amp1 n-input
6
A1_OUT
Amp1 output
7
A2P_DI
Amp2 diode output
8
A2N_IN
Amp2 n-input
9
A2_OUT
Amp2 output, Analog output
10
REF_OUT
Reference voltage (1/2VDD) output
11
COMP_IN
Comparator input
12
D_OUT
Comparator output
13
T_OUT
Moving detection output
14
VDD
Power supply
●Block Diagram/Application
C1
VDD
Preamp IC
DRAIN
Voltage
Regulator
C2
D
A1P_IN
+
-
C3
AMP2
-
47kΩ
7.5kΩ 33kΩ
10kΩ
G
+
650kΩ
AMP1
7.5kΩ
S
33kΩ
350kΩ
Pyroelectric
sensor
A1N_IN
A1_OUT
A2P_DI
A2N_IN
A2_OUT
REF_OUT
+
D_OUT
S
+
COMP_IN
T_OUT
R
GND
R5
R2
C4
R1
C5
R4
C6
R3
C7
C8
Please decide the constant after it confirms it enough examining the characteristic and the condition of the pyroelectric sensor.
REV. A
4/4
●Cautions on use.
(1) Absolute maximum ratings
Use of the IC in excess of absolute maximum ratings such as the applied voltage or operating temperature range
may result in IC damage. Assumptions should not be made regarding the state of the IC (short mode or open
mode) when such damage is suffered. A physical safety measure such as a fuse should be implemented when use
of the IC in aspecial mode where the absolute maximum ratings may be exceeded is anticipated.
(2) GND potential
Ensure a minimum GND pin potential in all operating conditions.
(3) Short circuit mode between terminals and wrong mounting
In order to mount the IC on a set PCB, pay thorough attention to the direction and offset of the ICs. Erroneous
mounting can destroy the IC. Furthermore, if a short circuit occurs due to foreign matters entering between
terminals or between the terminal and the power supply or the GND terminal, the IC can destroy.
(4) Actions in strong magnetic field
Use caution when using the IC in the presence of a strong magnetic field as doing so may cause the IC to
malfunction.
(5) Mutual impedance
Use short and wide wiring tracks for the power supply and ground to keep the mutual impedance as small as
possible .Use a capacitor to keep ripple to a minimum.
(6) About warm-up time
Operation depends on a power-supply voltage and an external constant for time until stabilizing. Please confirm
warm-up time enough when you use it.
REV. A
Notice
Notes
No copying or reproduction of this document, in part or in whole, is permitted without the
consent of ROHM Co.,Ltd.
The content specified herein is subject to change for improvement without notice.
The content specified herein is for the purpose of introducing ROHM's products (hereinafter
"Products"). If you wish to use any such Product, please be sure to refer to the specifications,
which can be obtained from ROHM upon request.
Examples of application circuits, circuit constants and any other information contained herein
illustrate the standard usage and operations of the Products. The peripheral conditions must
be taken into account when designing circuits for mass production.
Great care was taken in ensuring the accuracy of the information specified in this document.
However, should you incur any damage arising from any inaccuracy or misprint of such
information, ROHM shall bear no responsibility for such damage.
The technical information specified herein is intended only to show the typical functions of and
examples of application circuits for the Products. ROHM does not grant you, explicitly or
implicitly, any license to use or exercise intellectual property or other rights held by ROHM and
other parties. ROHM shall bear no responsibility whatsoever for any dispute arising from the
use of such technical information.
The Products specified in this document are intended to be used with general-use electronic
equipment or devices (such as audio visual equipment, office-automation equipment, communication devices, electronic appliances and amusement devices).
The Products specified in this document are not designed to be radiation tolerant.
While ROHM always makes efforts to enhance the quality and reliability of its Products, a
Product may fail or malfunction for a variety of reasons.
Please be sure to implement in your equipment using the Products safety measures to guard
against the possibility of physical injury, fire or any other damage caused in the event of the
failure of any Product, such as derating, redundancy, fire control and fail-safe designs. ROHM
shall bear no responsibility whatsoever for your use of any Product outside of the prescribed
scope or not in accordance with the instruction manual.
The Products are not designed or manufactured to be used with any equipment, device or
system which requires an extremely high level of reliability the failure or malfunction of which
may result in a direct threat to human life or create a risk of human injury (such as a medical
instrument, transportation equipment, aerospace machinery, nuclear-reactor controller,
fuel-controller or other safety device). ROHM shall bear no responsibility in any way for use of
any of the Products for the above special purposes. If a Product is intended to be used for any
such special purpose, please contact a ROHM sales representative before purchasing.
If you intend to export or ship overseas any Product or technology specified herein that may
be controlled under the Foreign Exchange and the Foreign Trade Law, you will be required to
obtain a license or permit under the Law.
Thank you for your accessing to ROHM product informations.
More detail product informations and catalogs are available, please contact us.
ROHM Customer Support System
http://www.rohm.com/contact/
www.rohm.com
© 2009 ROHM Co., Ltd. All rights reserved.
R0039A